Lixin Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Lixin Wang has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Gang Zhang
School of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin 150001, China
13 shared publications - Xin He
School of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin 150001, China
9 shared publications - Alistair Duffy
School of Engineering and Sustainable Development, De Montfort University, Leicester, U.K.
8 shared publications - Dazhi Yang
School of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin 150001, China
7 shared publications - Kaixing Chang
Harbin Institute of Technology, Shenzhen, China
6 shared publications Yankong Song
School of Mechanical Engineering and Automation, Harbin Institute of Technology (Shenzhen), Shenzhen, China
4 shared publications
Latest Publications
- 28 March 2026
- Published by Elsevier in Measurement
- Vol. 274
In situ monitoring of electrical connector degradation via cable port reflection response analysis
- 28 March 2026
- Published by Elsevier in Measurement
- Vol. 274
In situ monitoring of electrical connector degradation via cable port reflection response analysis
- 27 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-11
Fault Location and Evaluation in Coaxial Cables Based on Stepped Frequency Waveform Reflectometry and Electromagnetic Time Reversal
Soft faults in coaxial cables, such as insulation aging and micro-cracks, can evolve into severe failures if not detected timely. Existing reflectometry-based techniques are capable of promising fault localization but lack the ability and accuracy in evaluating fault severity. In this study, we propose a method that combines Electromagnetic Time Reversal (EMTR) and Stepped-Frequency Waveform Reflectometry (SFWR) to enhance both fault location and evaluation. The proposed technique utilizes stepped-frequency signals for time reversal, enabling precise reconstruction of reflected waveforms in both time and frequency domains. A signal fitting and amplitude compensation algorithm is further applied to estimate reflection coefficients, allowing quantification of fault degree. Experimental validation on coaxial cables demonstrates that the method performs well both in fault location and reflection coefficient estimation. Moreover, the approach can simultaneously detect and assess multiple faults with an accuracy exceeding conventional methods. Compared to traditional SFWR and BIS, the proposed method significantly improves diagnostic accuracy and provides a more precise fault evaluation. The study also investigates the performance of the proposed method under noisy conditions, where the results demonstrate its favorable applicability, making it suitable for predictive maintenance in industrial cable networks.
- 27 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-11
Fault Location and Evaluation in Coaxial Cables Based on Stepped Frequency Waveform Reflectometry and Electromagnetic Time Reversal
Soft faults in coaxial cables, such as insulation aging and micro-cracks, can evolve into severe failures if not detected timely. Existing reflectometry-based techniques are capable of promising fault localization but lack the ability and accuracy in evaluating fault severity. In this study, we propose a method that combines Electromagnetic Time Reversal (EMTR) and Stepped-Frequency Waveform Reflectometry (SFWR) to enhance both fault location and evaluation. The proposed technique utilizes stepped-frequency signals for time reversal, enabling precise reconstruction of reflected waveforms in both time and frequency domains. A signal fitting and amplitude compensation algorithm is further applied to estimate reflection coefficients, allowing quantification of fault degree. Experimental validation on coaxial cables demonstrates that the method performs well both in fault location and reflection coefficient estimation. Moreover, the approach can simultaneously detect and assess multiple faults with an accuracy exceeding conventional methods. Compared to traditional SFWR and BIS, the proposed method significantly improves diagnostic accuracy and provides a more precise fault evaluation. The study also investigates the performance of the proposed method under noisy conditions, where the results demonstrate its favorable applicability, making it suitable for predictive maintenance in industrial cable networks.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75, 3524811
Wideband Impedance Measurement for Long-Cable-Terminated Equipment via Integrated Probe-Cable Compensation and MVMD-Based Reflection-Coefficient Purification
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75, 3524811
Wideband Impedance Measurement for Long-Cable-Terminated Equipment via Integrated Probe-Cable Compensation and MVMD-Based Reflection-Coefficient Purification
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- p. 1
Effects of Tulip Contact Faults on the Broadband Impedance of 10 kV Switchgear Revealed by Non-Intrusive Dual Inductive Coupling Probe Measurement
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- p. 1
Effects of Tulip Contact Faults on the Broadband Impedance of 10 kV Switchgear Revealed by Non-Intrusive Dual Inductive Coupling Probe Measurement
- 31 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-15
Investigation of Broadband Electrical Contact Performance of Electrical Connectors Under Repeated Plugging and Unplugging Operations
The wear of the contact surface caused by relative sliding can degrade the electrical contact performance of the aviation electrical connector. This work mimics contact surface wear through repeated plugging and unplugging experiments. A non-contact in-circuit impedance measurement method using a dual inductive probe technique is employed to continuously measure the impedance of the circuit under test, which comprises the connector and connecting wire, across the 1 MHz to 150 MHz frequency range during the experiment. Subsequently, the electrical parameters of the degraded connector are determined by combining a lumped transmission line model of the connecting wire with a broadband impedance model of the connector, based on the measured impedance of the circuit under test. The experimental results indicate that as the number of plugging and unplugging cycles increases, the resonant frequency observed in the broadband impedance measurements decreases. This phenomenon is primarily attributed to an increase in the contact capacitance of the connector due to wear on the contact surfaces. After 2000 test cycles, the resonant frequency of the circuit under test decreased by 1.25 MHz. Parameter identification revealed that the contact capacitance of the connector increased from 11.6 pF to 48.9 pF, a 4.22-fold rise. Meanwhile, the DC contact resistance increased by only 1.15 times over the same period. These findings suggest that contact capacitance is a more sensitive indicator of early degradation than DC contact resistance.
- 31 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-15
Investigation of Broadband Electrical Contact Performance of Electrical Connectors Under Repeated Plugging and Unplugging Operations
The wear of the contact surface caused by relative sliding can degrade the electrical contact performance of the aviation electrical connector. This work mimics contact surface wear through repeated plugging and unplugging experiments. A non-contact in-circuit impedance measurement method using a dual inductive probe technique is employed to continuously measure the impedance of the circuit under test, which comprises the connector and connecting wire, across the 1 MHz to 150 MHz frequency range during the experiment. Subsequently, the electrical parameters of the degraded connector are determined by combining a lumped transmission line model of the connecting wire with a broadband impedance model of the connector, based on the measured impedance of the circuit under test. The experimental results indicate that as the number of plugging and unplugging cycles increases, the resonant frequency observed in the broadband impedance measurements decreases. This phenomenon is primarily attributed to an increase in the contact capacitance of the connector due to wear on the contact surfaces. After 2000 test cycles, the resonant frequency of the circuit under test decreased by 1.25 MHz. Parameter identification revealed that the contact capacitance of the connector increased from 11.6 pF to 48.9 pF, a 4.22-fold rise. Meanwhile, the DC contact resistance increased by only 1.15 times over the same period. These findings suggest that contact capacitance is a more sensitive indicator of early degradation than DC contact resistance.
- 27 September 2025
- Published by Elsevier in Measurement
- Vol. 258
Non-invasive measurement of cable scattering parameters using dual inductive probes
- 27 September 2025
- Published by Elsevier in Measurement
- Vol. 258
Non-invasive measurement of cable scattering parameters using dual inductive probes
- 18 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (19) , 37169-37180
Cable Soft-Fault Detection Method Based on Single-Inductive Probe Coupling Measurement
This work presents an inductive coupling method for detecting soft faults in cables. The scattering parameter S11 of the cables is measured using a clamp-on inductive probe in conjunction with a vector network analyzer, eliminating the need for direct physical contact between the cable and the test equipment. The measurement results obtained through this method are comparable to those of traditional techniques, thanks to the de-embedding of the probe’s response. An electromagnetic time reversal technique, based on the scattering parameters, is employed to detect soft faults, enabling not only fault location but also the estimation of the reflection coefficient associated with the fault. Experiments conducted on coaxial cables, RVV cables, and twisted pairs show that the proposed method can accurately locate soft faults. The location error is limited to no more than 0.96%, even in cases where the impedance mismatch at the fault is only 4%. Moreover, in the presence of noise, the proposed method maintains high accuracy in fault location, even when the signal-to-noise ratio (SNR) of the scattering parameters is as low as -20 dB.
- 18 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (19) , 37169-37180
Cable Soft-Fault Detection Method Based on Single-Inductive Probe Coupling Measurement
This work presents an inductive coupling method for detecting soft faults in cables. The scattering parameter S11 of the cables is measured using a clamp-on inductive probe in conjunction with a vector network analyzer, eliminating the need for direct physical contact between the cable and the test equipment. The measurement results obtained through this method are comparable to those of traditional techniques, thanks to the de-embedding of the probe’s response. An electromagnetic time reversal technique, based on the scattering parameters, is employed to detect soft faults, enabling not only fault location but also the estimation of the reflection coefficient associated with the fault. Experiments conducted on coaxial cables, RVV cables, and twisted pairs show that the proposed method can accurately locate soft faults. The location error is limited to no more than 0.96%, even in cases where the impedance mismatch at the fault is only 4%. Moreover, in the presence of noise, the proposed method maintains high accuracy in fault location, even when the signal-to-noise ratio (SNR) of the scattering parameters is as low as -20 dB.
- 18 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 67 (3) , 884-893
Equivalent Simulation Approach for the Shielding Effectiveness of Enclosures With Gasketed Seams
The gasketed seam is a critical factor affecting the shielding effectiveness of the enclosure. To accurately simulate the shielding effectiveness of the enclosure, it is necessary to model the gasketed seam. However, due to the complex microstructures on the contact surface of the gasketed seams, directly measuring and modeling the gasketed seams is challenging. To address the issue, this work puts forward an equivalent modeling approach. Based on the constraint that the transfer impedance is constant, the gasketed seams are modeled as isotropic regular structures instead of modeling the geometrical details. The transfer impedance can be made identical under different modeling conditions by establishing a connection between the key parameters (including the geometric and material-related ones) and the measured transfer impedance of the gasketed seam. This ensures that the electromagnetic field leakage through the gasketed seam remains consistent, ultimately achieving equivalent shielding effectiveness. In this way, modeling and simulating gasketed seams become straightforward and practical while keeping calculations accurate. Experimental results confirm the effectiveness of the equivalent modeling approach.
- 18 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 67 (3) , 884-893
Equivalent Simulation Approach for the Shielding Effectiveness of Enclosures With Gasketed Seams
The gasketed seam is a critical factor affecting the shielding effectiveness of the enclosure. To accurately simulate the shielding effectiveness of the enclosure, it is necessary to model the gasketed seam. However, due to the complex microstructures on the contact surface of the gasketed seams, directly measuring and modeling the gasketed seams is challenging. To address the issue, this work puts forward an equivalent modeling approach. Based on the constraint that the transfer impedance is constant, the gasketed seams are modeled as isotropic regular structures instead of modeling the geometrical details. The transfer impedance can be made identical under different modeling conditions by establishing a connection between the key parameters (including the geometric and material-related ones) and the measured transfer impedance of the gasketed seam. This ensures that the electromagnetic field leakage through the gasketed seam remains consistent, ultimately achieving equivalent shielding effectiveness. In this way, modeling and simulating gasketed seams become straightforward and practical while keeping calculations accurate. Experimental results confirm the effectiveness of the equivalent modeling approach.
- 25 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-13
Measurement of High-Frequency Transmission Characteristic Parameters of Shielded Cables Based on Reflection Coefficient Spectrum and Optimized Multivariate Variational Mode Decomposition
Fault diagnosis serves as a consistent approach to ensuring cable system stability, with high-frequency transmission characteristic parameters (HFTCPs) enhancing sensitivity, accuracy, and fault assessment capabilities. This article introduces a method for measuring HFTCPs using reflection coefficient spectrum (RCS) and optimized multivariate variational mode decomposition (MVMD), applicable to various shielded cables. Firstly, we model the RCS under impedance mismatch and elaborate on the error sources of traditional methods. Secondly, we calculate the signal's energy spectral density to determine the initial center time and mode number, and dynamically adjust the bandwidth balance parameter based on the SNR of RCS components. Subsequently, we utilize the optimized MVMD to decompose the RCS into mode banks, shift the modes' spectrum to the baseband using single-sideband modulation, and perform multiscale decomposition to eliminate noise mixed into the modes. Lastly, we design a homemade transmission line to interconnect the large cable and measuring instrument, correct the measuring plane using OSL calibration, and remove frequency dependence using the least squares method. The results show that the proposed method has high decomposition accuracy and execution efficiency, good noise robustness and large improvement in the accuracy and bandwidth of the acquired HFTCPs.
- 25 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-13
Measurement of High-Frequency Transmission Characteristic Parameters of Shielded Cables Based on Reflection Coefficient Spectrum and Optimized Multivariate Variational Mode Decomposition
Fault diagnosis serves as a consistent approach to ensuring cable system stability, with high-frequency transmission characteristic parameters (HFTCPs) enhancing sensitivity, accuracy, and fault assessment capabilities. This article introduces a method for measuring HFTCPs using reflection coefficient spectrum (RCS) and optimized multivariate variational mode decomposition (MVMD), applicable to various shielded cables. Firstly, we model the RCS under impedance mismatch and elaborate on the error sources of traditional methods. Secondly, we calculate the signal's energy spectral density to determine the initial center time and mode number, and dynamically adjust the bandwidth balance parameter based on the SNR of RCS components. Subsequently, we utilize the optimized MVMD to decompose the RCS into mode banks, shift the modes' spectrum to the baseband using single-sideband modulation, and perform multiscale decomposition to eliminate noise mixed into the modes. Lastly, we design a homemade transmission line to interconnect the large cable and measuring instrument, correct the measuring plane using OSL calibration, and remove frequency dependence using the least squares method. The results show that the proposed method has high decomposition accuracy and execution efficiency, good noise robustness and large improvement in the accuracy and bandwidth of the acquired HFTCPs.