RLRonghui Li

Ronghui Li

*This is an algorithmically generated author record based on publicly available information.

Ronghui Li has a total of 8 co-authors. Here are the top co-authors by number of shared publications:

  • Dong Pang

    Medical Device Division, Dongguan Eontec Co., Ltd., Dongguan 523662, China

    1 shared publication
  • Guojiang Wan

    Institute of Biomedical Engineering, College of Medicine, Key Laboratory of Advanced Technologies of Materials, Ministry of Education, Southwest Jiaotong University, Chengdu, China

    1 shared publication
  • Jiahao Chen

    Center of Oral Implantology, Stomatological Hospital, Southern Medical University, Guangzhou 510280, China

    1 shared publication
  • Jingtao Dai

    Department of Oral and Maxillofacial Surgery, University Hospital Tübingen, Osianderstr 2-8, 72076 Tübingen, Germany

    1 shared publication
  • Junyu Qian

    Key Laboratory of Advanced Technologies of Materials, Ministry of Education, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031, China

    1 shared publication
  • Ping Li

    School and Hospital of Stomatology, Guangdong Engineering Research Center of Oral Restoration and Reconstruction, Guangzhou Medical University, Guangzhou, China

    1 shared publication

Latest Publications

  • Open Access

    Influence of Surface Roughness on Biodegradability and Cytocompatibility of High-Purity Magnesium

    by Jiahao Chen, Jingtao Dai, Junyu Qian, Weirong Li, Ronghui Li, Dong Pang, Guojiang Wan, Ping Li, Shulan Xu

    High-purity magnesium (Mg) is a promising biodegradable metal for oral and maxillofacial implants. Appropriate surface roughness plays a critical role in the degradation behavior and the related cellular processes of biodegradable Mg-based metals. Nevertheless, the most optimized surface roughness has been questionable, especially for Mg-based oral and maxillofacial implants. Three representative scales of surface roughness were investigated in this study, including smooth (Sa < 0.5 µm), moderately rough (Sa between 1.0–2.0 µm), and rough (Sa > 2.0 µm). The results indicated that the degradation rate of the Mg specimen in the cell culture medium was significantly accelerated with increased surface roughness. Furthermore, an extract test revealed that Mg with different roughness did not induce an evident cytotoxic effect. Nonetheless, the smooth Mg surface had an adversely affected cell attachment. Therefore, the high-purity Mg with a moderately rough surface exhibited the most optimized balance between biodegradability and overall cytocompatibility.