Cindel Bonneux
Research Subjects
Cindel Bonneux has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Dominique Hansen
Rehabilitation Research Center (REVAL), Faculty of Rehabilitation Sciences, Hasselt University , Wetenschapspark 7, Diepenbeek 3590
2 shared publications - Karin Coninx
Hasselt University
2 shared publications - Martijn Scherrenberg
Faculty of Medicine, University of Antwerp , Antwerp
2 shared publications - Paul Dendale
Department of Cardiology, Heart Centre Hasselt, Jessa Hospital , Stadsomvaart 11, Hasselt 3500
2 shared publications - Deeman Yousif Mahmood
HCI and eHealth, Faculty of Sciences, Hasselt University, 3590 Diepenbeek, Belgium
1 shared publication - Dieuwke van Dartel
Biomedical Signals and Systems Group, University of Twente, 7500 AE Enschede, The Netherlands
1 shared publication
Latest Publications
- Open Access
- 24 December 2025
- Published by Elsevier in Experimental Gerontology
- Vol. 214, 113014
Association of grip indicators with post-discharge recovery in geriatric and hip fracture inpatients
- 24 December 2025
- Published by Elsevier in Experimental Gerontology
- Vol. 214, 113014
Open AccessAssociation of grip indicators with post-discharge recovery in geriatric and hip fracture inpatients
- Open Access
A Mobile Application to Perform the Six-Minute Walk Test (6MWT) at Home: A Random Walk in the Park Is as Accurate as a Standardized 6MWT
The six-minute walk test (6MWT) provides an objective measurement of a person’s functional exercise capacity. In this study, we developed a smartphone application that allows cardiac patients to do a self-administered 6MWT at home on a random trajectory. In a prospective study with 102 cardiovascular disease patients, we aimed to identify the optimal circumstances to perform a smartphone-measured 6MWT, i.e., the best algorithm and the best position to wear the smartphone during the test. Furthermore, we investigated if a random walk is as accurate as a standardized 6MWT. When considering both the reliability and accuracy of the distance walked, the best circumstances to perform a standardized smartphone-measured 6MWT are wearing the smartphone in a strap around the patient’s arm and using an algorithm that relies on the processed step count data acquired from Google Fit. Furthermore, we demonstrated that a smartphone-measured walk along a random trajectory is as accurate to determine a cardiac patient’s functional exercise capacity as a standardized (smartphone-measured) 6MWT. We conclude this paper by presenting how our 6MWT application can be used in a home setting to remotely follow up on cardiac patients’ functional exercise capacity.
Open AccessA Mobile Application to Perform the Six-Minute Walk Test (6MWT) at Home: A Random Walk in the Park Is as Accurate as a Standardized 6MWT
The six-minute walk test (6MWT) provides an objective measurement of a person’s functional exercise capacity. In this study, we developed a smartphone application that allows cardiac patients to do a self-administered 6MWT at home on a random trajectory. In a prospective study with 102 cardiovascular disease patients, we aimed to identify the optimal circumstances to perform a smartphone-measured 6MWT, i.e., the best algorithm and the best position to wear the smartphone during the test. Furthermore, we investigated if a random walk is as accurate as a standardized 6MWT. When considering both the reliability and accuracy of the distance walked, the best circumstances to perform a standardized smartphone-measured 6MWT are wearing the smartphone in a strap around the patient’s arm and using an algorithm that relies on the processed step count data acquired from Google Fit. Furthermore, we demonstrated that a smartphone-measured walk along a random trajectory is as accurate to determine a cardiac patient’s functional exercise capacity as a standardized (smartphone-measured) 6MWT. We conclude this paper by presenting how our 6MWT application can be used in a home setting to remotely follow up on cardiac patients’ functional exercise capacity.