Yuto Ihara
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yuto Ihara has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Yasuhiro Hayashi
Department of Electrical Engineering and Bioscience, Waseda University, Tokyo 169-8555, Japan
5 shared publications - Masataka Mitsuoka
Waseda University
4 shared publications - Yu Fujimoto
Advanced Collaborative Research Organization for Smart Society, Waseda University, Tokyo 169-8555, Japan
4 shared publications - Yutaka Iino
Advanced Collaborative Research Organization for Smart Society, Waseda University, Tokyo, Japan
4 shared publications - Fumiaki Osaki
Waseda University
3 shared publications - Satoru Shimokawa
Waseda University
3 shared publications
Latest Publications
- Open Access
- 29 September 2026
- Published by Elsevier in SSRN Electronic Journal
Residential heat pump water heaters as urban demand-response resources: CO₂ mitigation across spatially heterogeneous PV-surplus conditions and alternative participation scenarios
City-scale CO₂ reductions from demand response (DR) operation of residential heat pump water heaters (HPWHs) depend on low-carbon electricity availability and participation. This study developed a city-scale framework that integrates 30-min data from approximately 402,000 low-voltage smart meters at 1-km resolution in Utsunomiya City, Japan, with estimated photovoltaic (PV) generation to characterize spatio-temporal electricity supply-demand conditions and mesh-level PV surplus. The framework incorporated 30-min grid carbon intensity (CI), monthly hot-water demand, and three DR participation scenarios. At the current HPWH penetration (16.8%) and existing PV deployment, DR reduced HPWH CO₂ emissions by 3.5%, 6.1%, and 19.3% under the opt-in, opt-in + information, and opt-out scenarios, respectively. The mechanism-isolation analysis showed that alignment with lower daytime grid CI produced the largest isolated effect, followed by surplus-PV absorption and improved daytime system coefficient of performance. Because surplus-PV potential was limited in central urban meshes and greater in suburban areas, the opt-in + information scenario targeted participation toward surplus-rich meshes and achieved the highest PV-related CO₂ reduction per participant, whereas broad opt-out participation maximized the city-scale reduction. Thus, smart meter data can identify priority areas for DR and quantify the benefits of spatial targeting, although local enrollment responses to incentives remain to be validated. Parametric analysis showed synergistic reductions from PV and HPWH expansion under DR, with broad participation required to reach the policy-derived 2030 reference level within the examined scenarios. The proposed smart meter-based framework could support coordinated HPWH and PV deployment and spatially targeted DR recruitment and incentive design.
- 29 September 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessResidential heat pump water heaters as urban demand-response resources: CO₂ mitigation across spatially heterogeneous PV-surplus conditions and alternative participation scenarios
City-scale CO₂ reductions from demand response (DR) operation of residential heat pump water heaters (HPWHs) depend on low-carbon electricity availability and participation. This study developed a city-scale framework that integrates 30-min data from approximately 402,000 low-voltage smart meters at 1-km resolution in Utsunomiya City, Japan, with estimated photovoltaic (PV) generation to characterize spatio-temporal electricity supply-demand conditions and mesh-level PV surplus. The framework incorporated 30-min grid carbon intensity (CI), monthly hot-water demand, and three DR participation scenarios. At the current HPWH penetration (16.8%) and existing PV deployment, DR reduced HPWH CO₂ emissions by 3.5%, 6.1%, and 19.3% under the opt-in, opt-in + information, and opt-out scenarios, respectively. The mechanism-isolation analysis showed that alignment with lower daytime grid CI produced the largest isolated effect, followed by surplus-PV absorption and improved daytime system coefficient of performance. Because surplus-PV potential was limited in central urban meshes and greater in suburban areas, the opt-in + information scenario targeted participation toward surplus-rich meshes and achieved the highest PV-related CO₂ reduction per participant, whereas broad opt-out participation maximized the city-scale reduction. Thus, smart meter data can identify priority areas for DR and quantify the benefits of spatial targeting, although local enrollment responses to incentives remain to be validated. Parametric analysis showed synergistic reductions from PV and HPWH expansion under DR, with broad participation required to reach the policy-derived 2030 reference level within the examined scenarios. The proposed smart meter-based framework could support coordinated HPWH and PV deployment and spatially targeted DR recruitment and incentive design.
- Open Access
- 5 June 2026
- Published by Elsevier in SSRN Electronic Journal
Schedule-Constrained Charging Infrastructure Planning for Electric Bus Fleets Leveraging Spatiotemporal Low-Carbon Charging Opportunities
Urban electric bus (EB) fleets can reduce transport emissions, but the realized carbon benefit depends on where and when low-carbon charging opportunities are accessible within predetermined transportation schedules. Fixed bus schedules, limited charger accessibility, and peak demand limits create a spatial and temporal mismatch between low-carbon charging opportunities and schedule-constrained feasible charging opportunities, whereas carbon-credit conditions determine the economic value of accessing them. However, existing charging infrastructure planning approaches have rarely considered this coupling among carbon-intensity heterogeneity, schedule-constrained operational accessibility, and the economic values under carbon-credit conditions, instead treating carbon intensity as a static depot-level attribute. This study proposes an integrated planning framework that jointly determines charger counts, spatial charger allocation, and charging schedules for a multi-depot EB system. The framework minimizes annual total cost, comprising net carbon-credit, peak-demand-based contract capacity, and charger installation costs. Representative carbon-intensity patterns were extracted from one year of 30-min, 1-km-resolution data and embedded in a daily mixed-integer linear programming model. Annual performance was evaluated using the entire historical dataset of Utsunomiya, Japan. The framework was applied to a 162-bus, four-depot system under different carbon-credit scenarios, corresponding to Japan's current policy, announced pledges scenario, and net-zero emissions by 2050 scenario. Compared with schedule-constrained peak-shaving and static carbon-intensity-based planning, the proposed method reduced annual CO2 emissions by 17.6% and 9.71%, respectively, and annual operating-side cost by 7.45% and 3.60%, respectively. The findings demonstrate that cost-efficient low-carbon EB charging systems require the joint design of charger deployment and schedule-constrained operation under carbon-credit policy and heterogeneous carbon intensity.
- 5 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessSchedule-Constrained Charging Infrastructure Planning for Electric Bus Fleets Leveraging Spatiotemporal Low-Carbon Charging Opportunities
Urban electric bus (EB) fleets can reduce transport emissions, but the realized carbon benefit depends on where and when low-carbon charging opportunities are accessible within predetermined transportation schedules. Fixed bus schedules, limited charger accessibility, and peak demand limits create a spatial and temporal mismatch between low-carbon charging opportunities and schedule-constrained feasible charging opportunities, whereas carbon-credit conditions determine the economic value of accessing them. However, existing charging infrastructure planning approaches have rarely considered this coupling among carbon-intensity heterogeneity, schedule-constrained operational accessibility, and the economic values under carbon-credit conditions, instead treating carbon intensity as a static depot-level attribute. This study proposes an integrated planning framework that jointly determines charger counts, spatial charger allocation, and charging schedules for a multi-depot EB system. The framework minimizes annual total cost, comprising net carbon-credit, peak-demand-based contract capacity, and charger installation costs. Representative carbon-intensity patterns were extracted from one year of 30-min, 1-km-resolution data and embedded in a daily mixed-integer linear programming model. Annual performance was evaluated using the entire historical dataset of Utsunomiya, Japan. The framework was applied to a 162-bus, four-depot system under different carbon-credit scenarios, corresponding to Japan's current policy, announced pledges scenario, and net-zero emissions by 2050 scenario. Compared with schedule-constrained peak-shaving and static carbon-intensity-based planning, the proposed method reduced annual CO2 emissions by 17.6% and 9.71%, respectively, and annual operating-side cost by 7.45% and 3.60%, respectively. The findings demonstrate that cost-efficient low-carbon EB charging systems require the joint design of charger deployment and schedule-constrained operation under carbon-credit policy and heterogeneous carbon intensity.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 166375-166401
Schedule-Constrained Charging Infrastructure Planning for Electric Bus Fleets Leveraging Spatiotemporal Low-Carbon Charging Opportunities
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 166375-166401
Open AccessSchedule-Constrained Charging Infrastructure Planning for Electric Bus Fleets Leveraging Spatiotemporal Low-Carbon Charging Opportunities
- Open Access
- 3 July 2025
- Published by Elsevier in eTransportation
- Vol. 25
Dynamic bus charge scheduling by model predictive control to maximize local PV surplus power utilization
- 3 July 2025
- Published by Elsevier in eTransportation
- Vol. 25
Open AccessDynamic bus charge scheduling by model predictive control to maximize local PV surplus power utilization
- Open Access
- 23 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 56067-56080
Multipurpose Charging Schedule Optimization Method for Electric Buses: Evaluation Using Real City Data
The use of electric vehicles (EVs) and photovoltaics (PV) is increasing worldwide. Transportation networks require the effective use of renewable energy (RE) for EVs, whereas power networks require local consumption of PV energy, mainly at the initiative of local governments. Although many previous studies have addressed these requirements using private EVs as mobile storages, their uncertainty and uncontrollability remain highly problematic. Therefore, our previous studies focused on electric buses because of their high controllability and certainty. These studies involved the development and evaluation of two independent minimization problems—kilowatts (KW) and kilowatt-hours (KWH) of surplus RE—as a charging schedule optimization method using mixed integer linear programming. However, the feasibility of simultaneously minimizing KW and KWH still presented technical problems. This study aims to extend and generalize the method to the simultaneous minimization of KW and KWH of the PV-derived reverse power flow (RPF). With this multiobjective optimization, the KW peak-cut of the RPF improves the hosting capacity and increases the availability of connectable RE resources, whereas the minimization of KWH promotes the local consumption of RE and decarbonization of public transportation. Two simulations using detailed data of actual bus operations and actual power flow data for a real city confirmed the feasibility of simultaneously optimizing KW and KWH and the relationship between these indicators and number of EV chargers. The optimized charging of the 17 electric buses achieved a maximum of 211.4 kW peak-cut and 1318.4 kWh RE-RPF absorption, reducing CO 2 emissions by 495.7 kg/day.
- 23 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 56067-56080
Open AccessMultipurpose Charging Schedule Optimization Method for Electric Buses: Evaluation Using Real City Data
The use of electric vehicles (EVs) and photovoltaics (PV) is increasing worldwide. Transportation networks require the effective use of renewable energy (RE) for EVs, whereas power networks require local consumption of PV energy, mainly at the initiative of local governments. Although many previous studies have addressed these requirements using private EVs as mobile storages, their uncertainty and uncontrollability remain highly problematic. Therefore, our previous studies focused on electric buses because of their high controllability and certainty. These studies involved the development and evaluation of two independent minimization problems—kilowatts (KW) and kilowatt-hours (KWH) of surplus RE—as a charging schedule optimization method using mixed integer linear programming. However, the feasibility of simultaneously minimizing KW and KWH still presented technical problems. This study aims to extend and generalize the method to the simultaneous minimization of KW and KWH of the PV-derived reverse power flow (RPF). With this multiobjective optimization, the KW peak-cut of the RPF improves the hosting capacity and increases the availability of connectable RE resources, whereas the minimization of KWH promotes the local consumption of RE and decarbonization of public transportation. Two simulations using detailed data of actual bus operations and actual power flow data for a real city confirmed the feasibility of simultaneously optimizing KW and KWH and the relationship between these indicators and number of EV chargers. The optimized charging of the 17 electric buses achieved a maximum of 211.4 kW peak-cut and 1318.4 kWh RE-RPF absorption, reducing CO 2 emissions by 495.7 kg/day.
- 1 January 2022
- Published by Japan Society of Civil Engineers in Journal of Japan Society of Civil Engineers, Ser. D3 (Infrastructure Planning and Management)
- Vol. 77 (5) , I_711-I_719
将来の交通環境の変化が交通環境負荷に与える影響に関する研究
パリ協定を契機に設定された部門別の温室効果ガスの削減目標に対し,運輸部門ではより一層の交通環境負荷の低減を進めることが不可欠である.そこで,電気自動車(EV),次世代型路面電車システム(LRT),自動運転車(AV)など低炭素な次世代交通を導入することで,交通環境負荷を削減する試みが注目されている.本研究では,低炭素な交通機関に着目して,交通量,EV 普及率,電源構成比の観点から,実際の交通流の想定下で次世代交通機関が及ぼす環境改善効果を定量的に評価した.さらに,宇都宮市を対象に,テレワーク等による交通行動の変化を位置情報ビッグデータを用いて織り込んだ上で,交通環境負荷を算出し,テレワークが普及した 2050 年時には現状の半分程度まで削減可能であることを明らかにした.
- 1 January 2022
- Published by Japan Society of Civil Engineers in Journal of Japan Society of Civil Engineers, Ser. D3 (Infrastructure Planning and Management)
- Vol. 77 (5) , I_711-I_719
将来の交通環境の変化が交通環境負荷に与える影響に関する研究
パリ協定を契機に設定された部門別の温室効果ガスの削減目標に対し,運輸部門ではより一層の交通環境負荷の低減を進めることが不可欠である.そこで,電気自動車(EV),次世代型路面電車システム(LRT),自動運転車(AV)など低炭素な次世代交通を導入することで,交通環境負荷を削減する試みが注目されている.本研究では,低炭素な交通機関に着目して,交通量,EV 普及率,電源構成比の観点から,実際の交通流の想定下で次世代交通機関が及ぼす環境改善効果を定量的に評価した.さらに,宇都宮市を対象に,テレワーク等による交通行動の変化を位置情報ビッグデータを用いて織り込んだ上で,交通環境負荷を算出し,テレワークが普及した 2050 年時には現状の半分程度まで削減可能であることを明らかにした.