CZChangrui Zhang

Changrui Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Changrui Zhang has a total of 94 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Systematic opto-mechanical design approach for meter-long Nano-AKB mirror system at HEPS

    by Haihan Yu, Shanzhi Tang, Ming Li, Fang Liu, Changrui Zhang, Ruiying Liao, Lingfei Wang, Zongyang Yue, Ling Fan, Xuejie Jiang, et al.

    A systematic opto-mechanical design approach is developed for a long Nano-AKB mirror system aimed at stable sub-50 nm hard X-ray nanofocusing. The approach integrates deformation–stiffness-balanced mirror clamping, hierarchical precision alignment, and thermomechanical stability management and has been applied to nanofocusing instruments at HEPS. During beamline commissioning at HEPS ID19, the system achieved a focal spot of 34.6 ± 1.31 nm × 41.6 ± 0.67 nm (H × V) at 20 keV while maintaining Z-displacement stability below 5 nm RMS. The results meet the design expectations, strongly attesting to the efficacy and practical viability of the proposed approach.

  • Open Access

    Structure design and implementation of a water cooling sub-20 nm multilayer Kirkpatrick–Baez mirror system in the Structural Dynamics beamline ID23 at HEPS

    by Ruiying Liao, Haihan Yu, Jianye Wang, Xue Wang, Changrui Zhang, Wenkai Kang, Ling Fan, Chunxia Yao, Penghao Hou, Darui Sun, et al.

    The first water-cooling nano multilayer Kirkpatrick–Baez mirror system in the Structural Dynamics beamline (ID23) at High Energy Photon Source (HEPS) has been implemented. An Invar gantry is engineered to achieve a balance between light weight and stability. The cooling system, including eutectic gallium–indium (eGaIn), copper braids and a cooling water circuit with a multi-bend copper pipe in a compact space, decouples movement and mitigates vibration. The mirror cooling holders introduce less than 0.5 nm RMS height error and 0.1 µrad RMS slope error in the mirror surface shapes. A series of stability tests is applied to verify the mechanism structure. In a 1 h test assessment using a water-cooling flow of 4.5 L min −1 , the system demonstrated a positional stability of 5.96 nm and an angular stability of 86.76 nrad from 1 Hz to 500 Hz. The focal spot size of 13.39 nm × 15.15 nm (H × V) at a photon energy of 21.8 keV demonstrates the system's performance.

  • Subaperture moving strategy and related systematic errors in stitching interferometry of X-ray mirrors

    by Qiaoyu Wu, Qiushi Huang, Wenwen Zhang, Zhao Shi, Ming Li, Changrui Zhang, Yumei He, Hongxin Luo, Jun Yu, Weicheng Gu, et al.

    For high-precision metrology of X-ray mirrors, the subaperture moving strategy significantly impacts the accuracy of stitching interferometry. In this work, we investigated the systematic errors associated with various subaperture moving strategies of rotational stitching (RS), rotational displacement stitching (RDS), and displacement stitching (DS) in measuring X-ray mirrors. The effects of stitching strategies on a flat mirror and a spherical mirror with a radius of curvature (RoC) of 180 m and 60 m were compared. For the mirror with RoC of 60 m, the DS strategy showed the smallest height error of 3.3 nm (RMS) between algorithm-based stitching and the Nanometer Optical component Measuring machine (NOM), while RS showed a large error of 37.4 nm (RMS). The different regions of the interferometer aperture have different amplitudes of retrace errors, defocusing errors, and lateral distortion, which can lead to accumulations of systematic errors using the RS strategy. By reducing the pixel size from 0.268 mm/pixel to 0.089 mm/pixel, the measurement accuracy using the same RDS strategy improved from 7.4 nm (RMS) to 4.4 nm (RMS). Based on the optimal stitching strategy, the measurement accuracy of residual figure error of the X-ray mirror with a radius of curvature of 30 m reaches 0.2 nm (RMS).


  • Open Access

    Double-edge scan wavefront metrology and its application in crystal diffraction wavefront measurements

    by Fang Liu, Ming Li, Qianshun Diao, Zhe Li, Zhibang Shen, Fan Li, Zhen Hong, Hongkai Lian, Shuaipeng Yue, Qingyan Hou, et al.

    Achieving diffraction-limited performance in fourth-generation synchrotron radiation sources demands monochromator crystals that can preserve the wavefront across an unprecedented extensive range. There is an urgent need for techniques of absolute crystal diffraction wavefront measurement. At the Beijing Synchrotron Radiation Facility (BSRF), a novel edge scan wavefront metrology technique has been developed. This technique employs a double-edge tracking method, making diffraction-limited level absolute crystal diffraction wavefront measurement a reality. The results demonstrate an equivalent diffraction surface slope error below 70 nrad (corresponding to a wavefront phase error of 4.57% λ) r.m.s. within a nearly 6 mm range for a flat crystal in the crystal surface coordinate. The double-edge structure contributes to exceptional measurement precision for slope error reproducibility, achieving levels below 15 nrad (phase error reproducibility < λ/100) even at a first-generation synchrotron radiation source. Currently, the measurement termed double-edge scan (DES) has already been regarded as a critical feedback mechanism in the fabrication of next-generation crystals.


  • Open Access

    A magnetically controlled chemical–mechanical polishing (MC-CMP) approach for fabricating channel-cut silicon crystal optics for the High Energy Photon Source

    by Zhen Hong, Qianshun Diao, Wei Xu, Qingxi Yuan, Junliang Yang, Zhongliang Li, Yongcheng Jiang, Changrui Zhang, Dongni Zhang, Fang Liu, et al.

    Crystal monochromators are indispensable optical components for the majority of beamlines at synchrotron radiation facilities. Channel-cut monochromators are sometimes chosen to filter monochromatic X-ray beams by virtue of their ultrahigh angular stability. Nevertheless, high-accuracy polishing on the inner diffracting surfaces remains challenging, thus hampering their performance in preserving the coherence or wavefront of the photon beam. Herein, a magnetically controlled chemical–mechanical polishing (MC-CMP) approach has been successfully developed for fine polishing of the inner surfaces of channel-cut crystals. This MC-CMP process relieves the constraints of narrow working space dictated by small offset requirements and achieves near-perfect polishing on the surface of the crystals. Using this method, a high-quality surface with roughness of 0.614 nm (root mean square, r.m.s.) is obtained in a channel-cut crystal with 7 mm gap designed for beamlines at the High Energy Photon Source, a fourth-generation synchrotron radiation source under construction. On-line X-ray topography and rocking-curve measurements indicate that the stress residual layer on the crystal surface was removed. Firstly, the measured rocking-curve width is in good agreement with the theoretical value. Secondly, the peak reflectivity is very close to theoretical values. Thirdly, topographic images of the optics after polishing were uniform without any speckle or scratches. Only a nearly 2.5 nm-thick SiO2 layer was observed on the perfect crystalline matrix from high-resolution transmission electron microscopy photographs, indicating that the structure of the bulk material is defect- and dislocation-free. Future development of MC-CMP is promising for fabricating wavefront-preserving and ultra-stable channel-cut monochromators, which are crucial to exploit the merits of fourth-generation synchrotron radiation sources or hard X-ray free-electron lasers.


  • Design and analysis of surface plasmon resonance sensor based on multi-core photonic crystal fiber

    by Jiyu Dong, Changrui Zhang, Shule Xia, Kunyao Zhu, Shuhuan Zhang, Ying Yang, Hongwei Zhu, Huaifan Li


  • Stitching method based on dual quaternion for cylindrical mirrors

    by Shuai Zhang, Xi Hou, Wei Yan, Changrui Zhang, Die Qin, Xiaochuan Hu, Mengfan Li, Haiyang Quan

    In this study, a stitching method based on dual quaternion is proposed. The application of a dual quaternion in sub-aperture stitching interferometry is analyzed in detail, and a calculation method for sub-aperture stitching based on a dual quaternion is deduced. The experimental results demonstrate the accuracy of the stitching method proposed in this study (residuals of overlapping area approximately 0.22 nm RMS). Finally, the residual differences of 0.79 nm RMS between the figure errors are acquired with a stitching by parts algorithm based on the dual quaternion and long trace profiler (FSP at HEPS). The high-accuracy and high-efficiency stitching method proposed in this study will expand its application in the metrology and manufacture of long cylindrical mirrors.