David Cleres
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
David Cleres has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Filipe Barata
Centre for Digital Health Interventions, ETH Zurich, Zurich, Switzerland
6 shared publications - Martin Horvath Brutsche
Lung Center, Cantonal Hospital St. Gallen, St. Gallen, Switzerland
4 shared publications Elgar Fleisch
Affiliations Center for Digital Health Interventions, Department of Management, Technology and Economics, ETH Zurich, Zurich, Switzerland, Center for Digital Health Interventions, Institute of Technology Management, University of St. Gallen, St. Gallen, Switzerland
3 shared publications- Elgar Fleisch
Affiliations Department of Management, Technology, and Economics, ETH Zurich, Zurich, Switzerland, Institute of Technology Management, University of St. Gallen, St. Gallen, Switzerland
3 shared publications - Frank Rassouli
Lung Center, Cantonal Hospital St. Gallen, St. Gallen, Switzerland
3 shared publications - Maximilian Boesch
Lung Center, HOCH Health Ostschweiz, Kantonsspital St.Gallen, Universitäres Lehr- und Forschungsspital, St.Gallen, Switzerland
3 shared publications
Latest Publications
- Open Access
- 5 April 2023
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 18 (4) , e0283052
Trends in voice characteristics in patients with heart failure (VENTURE) in Switzerland: Protocol for a longitudinal observational pilot study
Introduction: Heart Failure (HF) is a major health and economic issue worldwide. HF-related expenses are largely driven by hospital admissions and re-admissions, many of which are potentially preventable. Current self-management programs, however, have failed to reduce hospital admissions. This may be explained by their low predictive power for decompensation and high adherence requirements. Slight alterations in the voice profile may allow to detect decompensation in HF patients at an earlier stage and reduce hospitalizations. This pilot study investigates the potential of voice as a digital biomarker to predict health status deterioration in HF patients. Methods and analysis: In a two-month longitudinal observational study, we collect voice samples and HF-related quality-of-life questionnaires from 35 stable HF patients. Patients use our developed study application installed on a tablet at home during the study period. From the collected data, we use signal processing to extract voice characteristics from the audio samples and associate them with the answers to the questionnaire data. The primary outcome will be the correlation between voice characteristics and HF-related quality-of-life health status. Ethics and dissemination: The study was reviewed and approved by the Cantonal Ethics Committee Zurich (BASEC ID:2022-00912). Results will be published in medical and technical peer-reviewed journals.
- 5 April 2023
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 18 (4) , e0283052
Open AccessTrends in voice characteristics in patients with heart failure (VENTURE) in Switzerland: Protocol for a longitudinal observational pilot study
Introduction: Heart Failure (HF) is a major health and economic issue worldwide. HF-related expenses are largely driven by hospital admissions and re-admissions, many of which are potentially preventable. Current self-management programs, however, have failed to reduce hospital admissions. This may be explained by their low predictive power for decompensation and high adherence requirements. Slight alterations in the voice profile may allow to detect decompensation in HF patients at an earlier stage and reduce hospitalizations. This pilot study investigates the potential of voice as a digital biomarker to predict health status deterioration in HF patients. Methods and analysis: In a two-month longitudinal observational study, we collect voice samples and HF-related quality-of-life questionnaires from 35 stable HF patients. Patients use our developed study application installed on a tablet at home during the study period. From the collected data, we use signal processing to extract voice characteristics from the audio samples and associate them with the answers to the questionnaire data. The primary outcome will be the correlation between voice characteristics and HF-related quality-of-life health status. Ethics and dissemination: The study was reviewed and approved by the Cantonal Ethics Committee Zurich (BASEC ID:2022-00912). Results will be published in medical and technical peer-reviewed journals.
- Open Access
- 9 March 2023
- Published by European Respiratory Society (ERS) in ERJ Open Research
- Vol. 9 (3)
Smartphone-based cough monitoring as a near real-time digital pneumonia biomarker
Background: Cough represents a cardinal symptom of acute respiratory tract infections. Generally associated with disease activity, cough holds biomarker potential and might be harnessed for prognosis and personalised treatment decisions. Here, we tested the suitability of cough as a digital biomarker for disease activity in coronavirus disease 2019 (COVID-19) and other lower respiratory tract infections. Methods: We conducted a single-centre, exploratory, observational cohort study on automated cough detection in patients hospitalised for COVID-19 (n=32) and non-COVID-19 pneumonia (n=14) between April and November 2020 at the Cantonal Hospital St Gallen, Switzerland. Cough detection was achieved using smartphone-based audio recordings coupled to an ensemble of convolutional neural networks. Cough levels were correlated to established markers of inflammation and oxygenation. Measurements and main results: Cough frequency was highest upon hospital admission and declined steadily with recovery. There was a characteristic pattern of daily cough fluctuations, with little activity during the night and two coughing peaks during the day. Hourly cough counts were strongly correlated with clinical markers of disease activity and laboratory markers of inflammation, suggesting cough as a surrogate of disease in acute respiratory tract infections. No apparent differences in cough evolution were observed between COVID-19 and non-COVID-19 pneumonia. Conclusions: Automated, quantitative, smartphone-based detection of cough is feasible in hospitalised patients and correlates with disease activity in lower respiratory tract infections. Our approach allows for near real-time telemonitoring of individuals in aerosol isolation. Larger trials are warranted to decipher the use of cough as a digital biomarker for prognosis and tailored treatment in lower respiratory tract infections.
- 9 March 2023
- Published by European Respiratory Society (ERS) in ERJ Open Research
- Vol. 9 (3)
Open AccessSmartphone-based cough monitoring as a near real-time digital pneumonia biomarker
Background: Cough represents a cardinal symptom of acute respiratory tract infections. Generally associated with disease activity, cough holds biomarker potential and might be harnessed for prognosis and personalised treatment decisions. Here, we tested the suitability of cough as a digital biomarker for disease activity in coronavirus disease 2019 (COVID-19) and other lower respiratory tract infections. Methods: We conducted a single-centre, exploratory, observational cohort study on automated cough detection in patients hospitalised for COVID-19 (n=32) and non-COVID-19 pneumonia (n=14) between April and November 2020 at the Cantonal Hospital St Gallen, Switzerland. Cough detection was achieved using smartphone-based audio recordings coupled to an ensemble of convolutional neural networks. Cough levels were correlated to established markers of inflammation and oxygenation. Measurements and main results: Cough frequency was highest upon hospital admission and declined steadily with recovery. There was a characteristic pattern of daily cough fluctuations, with little activity during the night and two coughing peaks during the day. Hourly cough counts were strongly correlated with clinical markers of disease activity and laboratory markers of inflammation, suggesting cough as a surrogate of disease in acute respiratory tract infections. No apparent differences in cough evolution were observed between COVID-19 and non-COVID-19 pneumonia. Conclusions: Automated, quantitative, smartphone-based detection of cough is feasible in hospitalised patients and correlates with disease activity in lower respiratory tract infections. Our approach allows for near real-time telemonitoring of individuals in aerosol isolation. Larger trials are warranted to decipher the use of cough as a digital biomarker for prognosis and tailored treatment in lower respiratory tract infections.
- Open Access
Trends in voice characteristics in patients with heart failure (VENTURE) in Switzerland: Protocol for a longitudinal observational pilot study
Introduction Heart Failure (HF) is a major health and economic issue worldwide. HF-related expenses are largely driven by hospital admissions and re-admissions, many of which are potentially preventable. Current self-management programs, however, have failed to reduce hospital admissions. This may be explained by their low predictive power for decompensation and high adherence requirements. Slight alterations in the voice profile may allow to detect decompensation in HF patients at an earlier stage and reduce hospitalizations. This pilot study investigates the potential of voice as a digital biomarker to predict health status deterioration in HF patients. Methods and analysis In a two-month longitudinal observational study, we collect voice samples and HF-related quality-of-life questionnaires from 35 stable HF patients. Patients use our developed study application installed on a tablet at home during the study period. From the collected data, we use signal processing to extract voice characteristics from the audio samples and associate them with the answers to the questionnaire data. The primary outcome will be the correlation between voice characteristics and HF-related quality-of-life health status. Ethics and dissemination The study was reviewed and approved by the Cantonal Ethics Committee Zurich (BASEC ID:2022-00912). Results will be published in medical and technical peer-reviewed journals.
Open AccessTrends in voice characteristics in patients with heart failure (VENTURE) in Switzerland: Protocol for a longitudinal observational pilot study
Introduction Heart Failure (HF) is a major health and economic issue worldwide. HF-related expenses are largely driven by hospital admissions and re-admissions, many of which are potentially preventable. Current self-management programs, however, have failed to reduce hospital admissions. This may be explained by their low predictive power for decompensation and high adherence requirements. Slight alterations in the voice profile may allow to detect decompensation in HF patients at an earlier stage and reduce hospitalizations. This pilot study investigates the potential of voice as a digital biomarker to predict health status deterioration in HF patients. Methods and analysis In a two-month longitudinal observational study, we collect voice samples and HF-related quality-of-life questionnaires from 35 stable HF patients. Patients use our developed study application installed on a tablet at home during the study period. From the collected data, we use signal processing to extract voice characteristics from the audio samples and associate them with the answers to the questionnaire data. The primary outcome will be the correlation between voice characteristics and HF-related quality-of-life health status. Ethics and dissemination The study was reviewed and approved by the Cantonal Ethics Committee Zurich (BASEC ID:2022-00912). Results will be published in medical and technical peer-reviewed journals.
- Open Access
- 20 February 2023
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 7, e38439
Nighttime Continuous Contactless Smartphone-Based Cough Monitoring for the Ward: Validation Study
Background: Clinical deterioration can go unnoticed in hospital wards for hours. Mobile technologies such as wearables and smartphones enable automated, continuous, noninvasive ward monitoring and allow the detection of subtle changes in vital signs. Cough can be effectively monitored through mobile technologies in the ward, as it is not only a symptom of prevalent respiratory diseases such as asthma, lung cancer, and COVID-19 but also a predictor of acute health deterioration. In past decades, many efforts have been made to develop an automatic cough counting tool. To date, however, there is neither a standardized, sufficiently validated method nor a scalable cough monitor that can be deployed on a consumer-centric device that reports cough counts continuously. These shortcomings limit the tracking of coughing and, consequently, hinder the monitoring of disease progression in prevalent respiratory diseases such as asthma, chronic obstructive pulmonary disease, and COVID-19 in the ward. Objective: This exploratory study involved the validation of an automated smartphone-based monitoring system for continuous cough counting in 2 different modes in the ward. Unlike previous studies that focused on evaluating cough detection models on unseen data, the focus of this work is to validate a holistic smartphone-based cough detection system operating in near real time. Methods: Automated cough counts were measured consistently on devices and on computers and compared with cough and noncough sounds counted manually over 8-hour long nocturnal recordings in 9 patients with pneumonia in the ward. The proposed cough detection system consists primarily of an Android app running on a smartphone that detects coughs and records sounds and secondarily of a backend that continuously receives the cough detection information and displays the hourly cough counts. Cough detection is based on an ensemble convolutional neural network developed and trained on asthmatic cough data. Results: In this validation study, a total of 72 hours of recordings from 9 participants with pneumonia, 4 of whom were infected with SARS-CoV-2, were analyzed. All the recordings were subjected to manual analysis by 2 blinded raters. The proposed system yielded a sensitivity and specificity of 72% and 99% on the device and 82% and 99% on the computer, respectively, for detecting coughs. The mean differences between the automated and human rater cough counts were −1.0 (95% CI −12.3 to 10.2) and −0.9 (95% CI −6.5 to 4.8) coughs per hour within subject for the on-device and on-computer modes, respectively. Conclusions: The proposed system thus represents a smartphone cough counter that can be used for continuous hourly assessment of cough frequency in the ward.
- 20 February 2023
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 7, e38439
Open AccessNighttime Continuous Contactless Smartphone-Based Cough Monitoring for the Ward: Validation Study
Background: Clinical deterioration can go unnoticed in hospital wards for hours. Mobile technologies such as wearables and smartphones enable automated, continuous, noninvasive ward monitoring and allow the detection of subtle changes in vital signs. Cough can be effectively monitored through mobile technologies in the ward, as it is not only a symptom of prevalent respiratory diseases such as asthma, lung cancer, and COVID-19 but also a predictor of acute health deterioration. In past decades, many efforts have been made to develop an automatic cough counting tool. To date, however, there is neither a standardized, sufficiently validated method nor a scalable cough monitor that can be deployed on a consumer-centric device that reports cough counts continuously. These shortcomings limit the tracking of coughing and, consequently, hinder the monitoring of disease progression in prevalent respiratory diseases such as asthma, chronic obstructive pulmonary disease, and COVID-19 in the ward. Objective: This exploratory study involved the validation of an automated smartphone-based monitoring system for continuous cough counting in 2 different modes in the ward. Unlike previous studies that focused on evaluating cough detection models on unseen data, the focus of this work is to validate a holistic smartphone-based cough detection system operating in near real time. Methods: Automated cough counts were measured consistently on devices and on computers and compared with cough and noncough sounds counted manually over 8-hour long nocturnal recordings in 9 patients with pneumonia in the ward. The proposed cough detection system consists primarily of an Android app running on a smartphone that detects coughs and records sounds and secondarily of a backend that continuously receives the cough detection information and displays the hourly cough counts. Cough detection is based on an ensemble convolutional neural network developed and trained on asthmatic cough data. Results: In this validation study, a total of 72 hours of recordings from 9 participants with pneumonia, 4 of whom were infected with SARS-CoV-2, were analyzed. All the recordings were subjected to manual analysis by 2 blinded raters. The proposed system yielded a sensitivity and specificity of 72% and 99% on the device and 82% and 99% on the computer, respectively, for detecting coughs. The mean differences between the automated and human rater cough counts were −1.0 (95% CI −12.3 to 10.2) and −0.9 (95% CI −6.5 to 4.8) coughs per hour within subject for the on-device and on-computer modes, respectively. Conclusions: The proposed system thus represents a smartphone cough counter that can be used for continuous hourly assessment of cough frequency in the ward.
- Open Access
- 14 April 2022
- Published by JMIR Publications Inc. in JMIR Preprints
Nighttime Continuous Contactless Smartphone-Based Cough Monitoring for the Ward: Validation Study (Preprint)
BACKGROUND Clinical deterioration can go unnoticed in hospital wards for hours. Mobile technologies such as wearables and smartphones enable automated, continuous, noninvasive ward monitoring and allow the detection of subtle changes in vital signs. Cough can be effectively monitored through mobile technologies in the ward, as it is not only a symptom of prevalent respiratory diseases such as asthma, lung cancer, and COVID-19 but also a predictor of acute health deterioration. In past decades, many efforts have been made to develop an automatic cough counting tool. To date, however, there is neither a standardized, sufficiently validated method nor a scalable cough monitor that can be deployed on a consumer-centric device that reports cough counts continuously. These shortcomings limit the tracking of coughing and, consequently, hinder the monitoring of disease progression in prevalent respiratory diseases such as asthma, chronic obstructive pulmonary disease, and COVID-19 in the ward. OBJECTIVE This exploratory study involved the validation of an automated smartphone-based monitoring system for continuous cough counting in 2 different modes in the ward. Unlike previous studies that focused on evaluating cough detection models on unseen data, the focus of this work is to validate a holistic smartphone-based cough detection system operating in near real time. METHODS Automated cough counts were measured consistently on devices and on computers and compared with cough and noncough sounds counted manually over 8-hour long nocturnal recordings in 9 patients with pneumonia in the ward. The proposed cough detection system consists primarily of an Android app running on a smartphone that detects coughs and records sounds and secondarily of a backend that continuously receives the cough detection information and displays the hourly cough counts. Cough detection is based on an ensemble convolutional neural network developed and trained on asthmatic cough data. RESULTS In this validation study, a total of 72 hours of recordings from 9 participants with pneumonia, 4 of whom were infected with SARS-CoV-2, were analyzed. All the recordings were subjected to manual analysis by 2 blinded raters. The proposed system yielded a sensitivity and specificity of 72% and 99% on the device and 82% and 99% on the computer, respectively, for detecting coughs. The mean differences between the automated and human rater cough counts were −1.0 (95% CI −12.3 to 10.2) and −0.9 (95% CI −6.5 to 4.8) coughs per hour within subject for the on-device and on-computer modes, respectively. CONCLUSIONS The proposed system thus represents a smartphone cough counter that can be used for continuous hourly assessment of cough frequency in the ward.
- 14 April 2022
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessNighttime Continuous Contactless Smartphone-Based Cough Monitoring for the Ward: Validation Study (Preprint)
BACKGROUND Clinical deterioration can go unnoticed in hospital wards for hours. Mobile technologies such as wearables and smartphones enable automated, continuous, noninvasive ward monitoring and allow the detection of subtle changes in vital signs. Cough can be effectively monitored through mobile technologies in the ward, as it is not only a symptom of prevalent respiratory diseases such as asthma, lung cancer, and COVID-19 but also a predictor of acute health deterioration. In past decades, many efforts have been made to develop an automatic cough counting tool. To date, however, there is neither a standardized, sufficiently validated method nor a scalable cough monitor that can be deployed on a consumer-centric device that reports cough counts continuously. These shortcomings limit the tracking of coughing and, consequently, hinder the monitoring of disease progression in prevalent respiratory diseases such as asthma, chronic obstructive pulmonary disease, and COVID-19 in the ward. OBJECTIVE This exploratory study involved the validation of an automated smartphone-based monitoring system for continuous cough counting in 2 different modes in the ward. Unlike previous studies that focused on evaluating cough detection models on unseen data, the focus of this work is to validate a holistic smartphone-based cough detection system operating in near real time. METHODS Automated cough counts were measured consistently on devices and on computers and compared with cough and noncough sounds counted manually over 8-hour long nocturnal recordings in 9 patients with pneumonia in the ward. The proposed cough detection system consists primarily of an Android app running on a smartphone that detects coughs and records sounds and secondarily of a backend that continuously receives the cough detection information and displays the hourly cough counts. Cough detection is based on an ensemble convolutional neural network developed and trained on asthmatic cough data. RESULTS In this validation study, a total of 72 hours of recordings from 9 participants with pneumonia, 4 of whom were infected with SARS-CoV-2, were analyzed. All the recordings were subjected to manual analysis by 2 blinded raters. The proposed system yielded a sensitivity and specificity of 72% and 99% on the device and 82% and 99% on the computer, respectively, for detecting coughs. The mean differences between the automated and human rater cough counts were −1.0 (95% CI −12.3 to 10.2) and −0.9 (95% CI −6.5 to 4.8) coughs per hour within subject for the on-device and on-computer modes, respectively. CONCLUSIONS The proposed system thus represents a smartphone cough counter that can be used for continuous hourly assessment of cough frequency in the ward.
- Open Access
- 23 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 26 (6) , 2746-2757
TripletCough: Cougher Identification and Verification From Contact-Free Smartphone-Based Audio Recordings Using Metric Learning
Cough, a symptom associated with many prevalent respiratory diseases, can serve as a potential biomarker for diagnosis and disease progression. Consequently, the development of cough monitoring systems and, in particular, automatic cough detection algorithms have been studied since the early 2000s. Recently, there has been an increased focus on the efficiency of such algorithms, as implementation on consumer-centric devices such as smartphones would provide a scalable and affordable solution for monitoring cough with contact-free sensors. Current algorithms, however, are incapable of discerning between coughs of different individuals and, thus, cannot function reliably in situations where potentially multiple individuals have to be monitored in shared environments. Therefore, we propose a weakly supervised metric learning approach for cougher recognition based on smartphone audio recordings of coughs. Our approach involves a triplet network architecture, which employs convolutional neural networks (CNNs). The CNNs of the triplet network learn an embedding function, which maps Mel spectrograms of cough recordings to an embedding space where they are more easily distinguishable. Using audio recordings of nocturnal coughs from asthmatic patients captured with a smartphone, our approach achieved a mean accuracy of 88% (10% SD) on two-way identification tests with 12 enrollment samples and accuracy of 80% and an equal error rate (EER) of 20% on verification tests. Furthermore, our approach outperformed human raters with regard to verification tests on average by 8% in accuracy, 4% in false acceptance rate (FAR), and 12% in false rejection rate (FRR). Our code and models are publicly available.
- 23 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 26 (6) , 2746-2757
Open AccessTripletCough: Cougher Identification and Verification From Contact-Free Smartphone-Based Audio Recordings Using Metric Learning
Cough, a symptom associated with many prevalent respiratory diseases, can serve as a potential biomarker for diagnosis and disease progression. Consequently, the development of cough monitoring systems and, in particular, automatic cough detection algorithms have been studied since the early 2000s. Recently, there has been an increased focus on the efficiency of such algorithms, as implementation on consumer-centric devices such as smartphones would provide a scalable and affordable solution for monitoring cough with contact-free sensors. Current algorithms, however, are incapable of discerning between coughs of different individuals and, thus, cannot function reliably in situations where potentially multiple individuals have to be monitored in shared environments. Therefore, we propose a weakly supervised metric learning approach for cougher recognition based on smartphone audio recordings of coughs. Our approach involves a triplet network architecture, which employs convolutional neural networks (CNNs). The CNNs of the triplet network learn an embedding function, which maps Mel spectrograms of cough recordings to an embedding space where they are more easily distinguishable. Using audio recordings of nocturnal coughs from asthmatic patients captured with a smartphone, our approach achieved a mean accuracy of 88% (10% SD) on two-way identification tests with 12 enrollment samples and accuracy of 80% and an equal error rate (EER) of 20% on verification tests. Furthermore, our approach outperformed human raters with regard to verification tests on average by 8% in accuracy, 4% in false acceptance rate (FAR), and 12% in false rejection rate (FRR). Our code and models are publicly available.