SDSidhant Dalal

Sidhant Dalal

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sidhant Dalal has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Severe Obesity Is an Independent Risk Factor of Early Readmission and Nonhome Discharge After Cervical Disc Replacement

    by Tejas Subramanian, Daniel Shinn, Pratyush Shahi, Izzet Akosman, Troy Amen, Omri Maayan, Eric Zhao, Kasra Araghi, Junho Song, Sidhant Dalal, et al.

    Objective: Despite growing interest in cervical disc replacement (CDR) for conditions such as cervical radiculopathy, limited data exists describing the impact of obesity on early postoperative outcomes and complications. These data are especially important as nearly half of the adult population in the United States is expected to become obese (body mass index [BMI] ≥ 30 kg/m2) by 2030. The goal of this study was to compare the demographics, perioperative variables, and complication rates following CDR.Methods: The 2005–2020 American College of Surgeons National Surgical Quality Improvement Program datasets were queried for patients who underwent primary 1- or 2-level CDR. Patients were divided into 3 cohorts: Nonobese (BMI: 18.5–29.9 kg/m2), Obese class-I (BMI: 30–34.9 kg/m2), Obese class-II/III (BMI ≥ 35 kg/m2). Morbidity was defined as the presence of any complication within 30 days postoperatively. Rates of 30-day readmission, reoperation, morbidity, individual complications, length of stay, frequency of nonhome discharge disposition were collected.Results: A total of 5,397 patients were included for analysis: 3,130 were nonobese, 1,348 were obese class I, and 919 were obese class II/III. There were more 2-level CDRs performed in the class II/III cohort compared to the nonobese group (25.7% vs. 21.5%, respectively; p < 0.05). Class-II/III had more nonhome discharges than class I and nonobese (2.1% vs. 0.5% vs. 0.7%, respectively; p < 0.001). Readmission rates differed as well (nonobese: 0.5%, class I: 1.1%, class II/III: 2.1%; p < 0.001) with pairwise significance between class II/II and nonobese. Class II/III obesity was an independent risk factor for both readmission (odds ratio [OR], 3.32; p = 0.002) and nonhome discharge (OR, 2.51; p = 0.02). Neither 30-day reoperation nor morbidity rates demonstrated significance. No mortalities were reported.Conclusion: Although obese class-II/III were risk factors for 30-day readmission and nonhome discharge, there was no significant difference in reoperation rates or morbidity. CDR procedures can continue to be safely preformed independent of obesity status.


  • Open Access

    Floor-Mounted Robotic Pedicle Screw Placement in Lumbar Spine Surgery: An Analysis of 1,050 Screws

    by Pratyush Shahi, Omri Maayan, Daniel Shinn, Sidhant Dalal, Junho Song, Kasra Araghi, Dimitra Melissaridou, Avani Vaishnav, Karim Shafi, Yuri Pompeu, et al.

    Objective: To analyze the usage of floor-mounted robot in minimally invasive lumbar fusion.Methods: Patients who underwent minimally invasive lumbar fusion for degenerative pathology using floor-mounted robot (ExcelsiusGPS) were included. Pedicle screw accuracy, proximal level violation rate, pedicle screw size, screw-related complications, and robot abandonment rate were analyzed.Results: Two hundred twenty-nine patients were included. Most surgeries were primary single-level fusion. Sixty-five percent of surgeries had intraoperative computed tomography (CT) workflow, 35% had preoperative CT workflow. Sixty-six percent were transforaminal lumbar interbody fusion, 16% were lateral, 8% were anterior, and 10% were a combined approach. A total of 1,050 screws were placed with robotic assistance (85% in prone position, 15% in lateral position). Postoperative CT scan was available for 80 patients (419 screws). Overall pedicle screw accuracy rate was 96.4% (prone, 96.7%; lateral, 94.2%; primary, 96.7%; revision, 95.3%). Overall poor screw placement rate was 2.8% (prone, 2.7%; lateral, 3.8%; primary, 2.7%; revision, 3.5%). Overall proximal facet and endplate violation rates were 0.4% and 0.9%. Average diameter and length of pedicle screws were 7.1 mm and 47.7 mm. Screw revision had to be done for 1 screw (0.1%). Use of the robot had to be aborted in 2 cases (0.8%).Conclusion: Usage of floor-mounted robotics for the placement of lumbar pedicle screws leads to excellent accuracy, large screw size, and negligible screw-related complications. It does so for screw placement in prone/lateral position and primary/revision surgery alike with negligible robot abandonment rates.


  • P136. Predictors of non-improvement after minimally invasive lumbar spine surgery

    by Junho Song, Pratyush Shahi, Kasra Araghi, Dimitra Melissaridou, Daniel Shinn, Sidhant Dalal, Harvinder S. Sandhu, Todd J. Albert, Sheeraz A. Qureshi, Sravisht Iyer

  • Practical answers to frequently asked questions in minimally invasive lumbar spine surgery

    by Pratyush Shahi, Avani S. Vaishnav, Eric Mai, Jeong Hoon Kim, Sidhant Dalal, Junho Song, Daniel J. Shinn, Dimitra Melissaridou, Kasra Araghi, Hikari Urakawa, et al.


  • Reoperations after primary and revision lumbar discectomy: study of a national-level cohort with eight years follow-up

    by Sidhant S. Dalal, Devin A. Dupree, Andre M. Samuel, Avani S. Vaishnav, Catherine Himo Gang, Sheeraz A. Qureshi, David B. Bumpass, Samuel C. Overley


  • Association between muscle health and patient-reported outcomes after lumbar microdiscectomy: early results

    by Junho Song, Kasra Araghi, Marcel M. Dupont, Pratyush Shahi, Patawut Bovonratwet, Daniel Shinn, Sidhant S. Dalal, Dimitra Melissaridou, Sohrab S. Virk, Sravisht Iyer, et al.