Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lin Han has a total of 8 co-authors. Here are the top co-authors by number of shared publications:

  • Fuchun Yang

    Key Laboratory of High Efficiency and Clean Mechanical Manufacture of MOE, School of Mechanical Engineering, Shandong University, Jinan, China

    2 shared publications
  • Lijun Dong

    Molecular Biophysics, Zernike Institute, University of Groningen 1 , Nijenborgh 3, 9747 AG Groningen

    2 shared publications
  • Richard Li

    School of Computer Science and Engineering, Southeast University, Nanjing, China

    2 shared publications
  • Dianrui Wang

    Key Laboratory of High Efficiency and Clean Mechanical Manufacture of MOE, School of Mechanical Engineering, Shandong University, Jinan 250061, China

    1 shared publication
  • Dianrui Wang

    Key Laboratory of High Efficiency and Clean Mechanical Manufacture of MOE, School of Mechanical Engineering, Shandong University, Jinan 250061, China

    1 shared publication
  • Muhammad Anwar Jan

    Key Laboratory of High Efficiency and Clean Mechanical Manufacture of MOE, School of Mechanical Engineering, Shandong University, Jinan 250061, China

    1 shared publication

Latest Publications

  • Open Access

    Stiffness Modeling of Tooth Interior Fatigue and Tooth Flank Fracture and Their Fault Characteristics in Electromechanical Coupling Systems

    by Lin Han, Dianrui Wang, Muhammad Anwar Jan, Fuchun Yang

    Tooth flank fracture (TFF) and tooth interior fatigue fracture (TIFF) usually occur on case‐harden gears in electromechanical coupling systems, both starting from the core caused by metal fatigue. The cracks propagate rapidly compared with the total life of a gear, so that it is necessary to detect and identify the faults in time when they take place in order to avoid danger. In this paper, the time‐varying mesh stiffness model of two types of faults is established by the potential energy method and validating by the finite element method. Based on the stiffness model, the influence of faults on the electromechanical system and their fault characteristics are analyzed, which provides a theoretical basis for the health detection of electromechanical coupling systems. The results indicate that in the early stage of the three faults, i.e., tooth root fracture, tooth interior fatigue fracture, and tooth flank fracture, it is hard to discriminate the faults. But after the second stage, the faults can be distinguished by the vibration amplitude, frequency band components, and phase diagrams. The TFF can be discerned into different stages by frequency domains and phase diagrams. When the fracture occurs completely, three faults can be easily distinguished by the time domain and phase diagram. In the frequency domain, the TRF can also be distinguished from the other two faults by referring to the sideband component near the meshing frequency.


  • Open Access

    Vibration Characteristics of the Dual Electric Propulsion System of Vessels under Electromechanical Coupling Excitation

    by Lin Han, Dianrui Wang, Fuchun Yang, Weikai He

    An electromechanical coupling driving system is a commonly used system for large overloading ships. In this paper, a dual input electromechanical coupling model, including an inverter power supply, three-phase induction motor, fixed-axis gear, and load, is established. The influences of the gear error, inverter, and coupling stiffness on the vibration characteristics of the system are studied, and the influences of each parameter on the vibration characteristics are analyzed. The inverter power supply part considers the constant voltage–frequency ratio control and sinusoidal pulse width modulation, as well as the inverter. The motor part uses the dynamic motor model based on the equivalent circuit. The fixed-axis gear section uses a translation–torsion model with time-varying mesh stiffness and damping. The mechanical part and the motor part are coupled with the load torque of the motor. The results show that the greater the error of the gear, the greater the vibration of the system, and the rotation frequency error is the main factor. Secondly, by comparing the influence of error value and accuracy difference on vibration, we found that when an accuracy difference exists, the dominant factor of system vibration is the accuracy difference. Thirdly, the use of an inverter also increases the vibration of the electromechanical coupling system. Finally, we found that the lower stiffness of the elastic coupling reduced the vibration of the system.


  • A Framework for Bandwidth and Latency Guaranteed Service in New IP Network

    by Lin Han, Yingzhen Qu, Lijun Dong, Richard Li

    More and more applications require end-to-end guaranteed services for bandwidth and latency. Current best-effort based IP Internet cannot provide such services, and new IP-based solution is needed to meet the new service requirements. This paper proposes a framework to support such guaranteed services. It is based on new control plane and data plan. The new control plane could provide flow-based service and program hardware accordingly, and the new data plane can guarantee different services for different flows with agreed bandwidth and latency. The paper focuses on the latency guaranteed service, provides both theoretical per-hop latency estimation and experimental verification.