Katherine Bishara
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Katherine Bishara has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Jennie H. Kwon
Medical University of South Carolina
3 shared publications - Taufiek Konrad Rajab
Department of Cardiovascular Pediatric Surgery Arkansas Children's Hospital Little Rock Arkansas USA
3 shared publications - Morgan A. Hill
Department of Surgery, Medical University of South Carolina
2 shared publications B A Ibrahim
University of South Carolina School of Medicine, Columbia, SC 29016
1 shared publicationC Sabin
University of South Carolina School of Medicine, Columbia, SC 29016
1 shared publicationG Pathak
University of South Carolina School of Medicine, Columbia, SC 29016
1 shared publication
Latest Publications
- Open Access
- 10 June 2023
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 10 (6) , 254
Characterization of Green Fluorescent Protein in Heart Valves of a Transgenic Swine Model for Partial Heart Transplant Research
A transgenic strain of pigs was created to express green fluorescent protein (GFP) ubiquitously using a pCAGG promoter. Here, we characterize GFP expression in the semilunar valves and great arteries of GFP-transgenic (GFP-Tg) pigs. Immunofluorescence was performed to visualize and quantify GFP expression and colocalization with nuclear staining. GFP expression was confirmed in both the semilunar valves and great arteries of GFP-Tg pigs compared to wild-type tissues (aorta, p = 0.0002; pulmonary artery, p = 0.0005; aortic valve; and pulmonic valve, p < 0.0001). The quantification of GFP expression in cardiac tissue allows this strain of GFP-Tg pigs to be used for future research in partial heart transplantation.
- 10 June 2023
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 10 (6) , 254
Open AccessCharacterization of Green Fluorescent Protein in Heart Valves of a Transgenic Swine Model for Partial Heart Transplant Research
A transgenic strain of pigs was created to express green fluorescent protein (GFP) ubiquitously using a pCAGG promoter. Here, we characterize GFP expression in the semilunar valves and great arteries of GFP-transgenic (GFP-Tg) pigs. Immunofluorescence was performed to visualize and quantify GFP expression and colocalization with nuclear staining. GFP expression was confirmed in both the semilunar valves and great arteries of GFP-Tg pigs compared to wild-type tissues (aorta, p = 0.0002; pulmonary artery, p = 0.0005; aortic valve; and pulmonic valve, p < 0.0001). The quantification of GFP expression in cardiac tissue allows this strain of GFP-Tg pigs to be used for future research in partial heart transplantation.
- Open Access
- 26 May 2023
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 10 (6) , 234
Morbidity and Mortality of Heterotopic Partial Heart Transplantation in Rodent Models
Unrepairable congenital heart valve disease is an unsolved problem in pediatric cardiac surgery because there are no growing heart valve implants. Partial heart transplantation is a new type of transplant that aims to solve this problem. In order to study the unique transplant biology of partial heart transplantation, animal models are necessary. This study aimed to assess the morbidity and mortality of heterotopic partial heart transplantation in rodent models. This study assessed two models. The first model involved transplanting heart valves from donor animals into the abdominal aortic position in the recipient animals. The second model involved transplanting heart valve leaflets into the renal subcapsular position of the recipient animals. A total of 33 animals underwent heterotopic partial heart transplantation in the abdominal aortic position. The results of this model found a 60.61% (n = 20/33) intraoperative mortality rate and a 39.39% (n = 13/33) perioperative mortality rate. Intraoperative mortality was due to vascular complications from the procedure, and perioperative mortality was due to graft thrombosis. A total of 33 animals underwent heterotopic partial heart transplantation in the renal subcapsular position. The results of this model found a 3.03% (n = 1/33) intraoperative mortality rate, and the remaining 96.97% survived (n = 32/33). We conclude that the renal subcapsular model has a lower mortality rate and is technically more accessible than the abdominal aortic model. While the heterotopic transplantation of valves into the abdominal aortic position had significant morbidity and mortality in the rodent model, the renal subcapsular model provided evidence for successful heterotopic transplantation.
- 26 May 2023
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 10 (6) , 234
Open AccessMorbidity and Mortality of Heterotopic Partial Heart Transplantation in Rodent Models
Unrepairable congenital heart valve disease is an unsolved problem in pediatric cardiac surgery because there are no growing heart valve implants. Partial heart transplantation is a new type of transplant that aims to solve this problem. In order to study the unique transplant biology of partial heart transplantation, animal models are necessary. This study aimed to assess the morbidity and mortality of heterotopic partial heart transplantation in rodent models. This study assessed two models. The first model involved transplanting heart valves from donor animals into the abdominal aortic position in the recipient animals. The second model involved transplanting heart valve leaflets into the renal subcapsular position of the recipient animals. A total of 33 animals underwent heterotopic partial heart transplantation in the abdominal aortic position. The results of this model found a 60.61% (n = 20/33) intraoperative mortality rate and a 39.39% (n = 13/33) perioperative mortality rate. Intraoperative mortality was due to vascular complications from the procedure, and perioperative mortality was due to graft thrombosis. A total of 33 animals underwent heterotopic partial heart transplantation in the renal subcapsular position. The results of this model found a 3.03% (n = 1/33) intraoperative mortality rate, and the remaining 96.97% survived (n = 32/33). We conclude that the renal subcapsular model has a lower mortality rate and is technically more accessible than the abdominal aortic model. While the heterotopic transplantation of valves into the abdominal aortic position had significant morbidity and mortality in the rodent model, the renal subcapsular model provided evidence for successful heterotopic transplantation.
- Open Access
- 20 June 2022
- Published by MDPI AG in Bioengineering
- Vol. 9 (6) , 264
Physiological Ventricular Simulator for Valve Surgery Training
Surgical simulation is becoming increasingly important in training cardiac surgeons. However, there are currently no training simulators capable of testing the quality of simulated heart valve procedures under dynamic physiologic conditions. Here we describe a dynamic ventricular simulator, consisting of a 3D printed valve suspension chamber and a model 1423 Harvard apparatus pulsatile pump, which can provide close to physiologic hemodynamic perfusion of porcine aortic roots attached to the valve chamber for education and training in cardiac surgery. The simulator was validated by using it to test aortic valve leaflet repairs (n = 6) and aortic valve replacements (n = 3) that were performed by two trainees. Procedural success could be evaluated by direct visualization of the opening and closing valve, hemodynamic measurements and echocardiography. We conclude that, unlike other methods of simulation, this novel ventricular simulator is able to test the functional efficacy of aortic procedures under dynamic physiologic conditions using clinically relevant echocardiographic and hemodynamic outcomes. While validated for valve surgery, other potential applications include ascending aortic interventions, coronary re-implantation or catheter-based valve replacements.
- 20 June 2022
- Published by MDPI AG in Bioengineering
- Vol. 9 (6) , 264
Open AccessPhysiological Ventricular Simulator for Valve Surgery Training
Surgical simulation is becoming increasingly important in training cardiac surgeons. However, there are currently no training simulators capable of testing the quality of simulated heart valve procedures under dynamic physiologic conditions. Here we describe a dynamic ventricular simulator, consisting of a 3D printed valve suspension chamber and a model 1423 Harvard apparatus pulsatile pump, which can provide close to physiologic hemodynamic perfusion of porcine aortic roots attached to the valve chamber for education and training in cardiac surgery. The simulator was validated by using it to test aortic valve leaflet repairs (n = 6) and aortic valve replacements (n = 3) that were performed by two trainees. Procedural success could be evaluated by direct visualization of the opening and closing valve, hemodynamic measurements and echocardiography. We conclude that, unlike other methods of simulation, this novel ventricular simulator is able to test the functional efficacy of aortic procedures under dynamic physiologic conditions using clinically relevant echocardiographic and hemodynamic outcomes. While validated for valve surgery, other potential applications include ascending aortic interventions, coronary re-implantation or catheter-based valve replacements.
- Open Access
- 20 September 2016
- Published by Springer Nature in Molecular Psychiatry
- Vol. 22 (12) , 1714-1724
PDE11A negatively regulates lithium responsivity
Lithium responsivity in patients with bipolar disorder has been genetically associated with Phosphodiesterase 11A (PDE11A), and lithium decreases PDE11A mRNA in induced pluripotent stem cell-derived hippocampal neurons originating from lithium-responsive patients. PDE11 is an enzyme uniquely enriched in the hippocampus that breaks down cyclic AMP and cyclic GMP. Here we determined whether decreasing PDE11A expression is sufficient to increase lithium responsivity in mice. In dorsal hippocampus and ventral hippocampus (VHIPP), lithium-responsive C57BL/6J and 129S6/SvEvTac mice show decreased PDE11A4 protein expression relative to lithium-unresponsive BALB/cJ mice. In VHIPP, C57BL/6J mice also show differences in PDE11A4 compartmentalization relative to BALB/cJ mice. In contrast, neither PDE2A nor PDE10A expression differ among the strains. The compartment-specific differences in PDE11A4 protein expression are explained by a coding single-nucleotide polymorphism (SNP) at amino acid 499, which falls within the GAF-B homodimerization domain. Relative to the BALB/cJ 499T, the C57BL/6J 499A decreases PDE11A4 homodimerization, which removes PDE11A4 from the membrane. Consistent with the observation that lower PDE11A4 expression correlates with better lithium responsiveness, we found that Pde11a knockout mice (KO) given 0.4% lithium chow for 3+ weeks exhibit greater lithium responsivity relative to wild-type (WT) littermates in tail suspension, an antidepressant-predictive assay, and amphetamine hyperlocomotion, an anti-manic predictive assay. Reduced PDE11A4 expression may represent a lithium-sensitive pathophysiology, because both C57BL/6J and Pde11a KO mice show increased expression of the pro-inflammatory cytokine interleukin-6 (IL-6) relative to BALB/cJ and PDE11A WT mice, respectively. Our finding that PDE11A4 negatively regulates lithium responsivity in mice suggests that the PDE11A SNPs identified in patients may be functionally relevant.
- 20 September 2016
- Published by Springer Nature in Molecular Psychiatry
- Vol. 22 (12) , 1714-1724
Open AccessPDE11A negatively regulates lithium responsivity
Lithium responsivity in patients with bipolar disorder has been genetically associated with Phosphodiesterase 11A (PDE11A), and lithium decreases PDE11A mRNA in induced pluripotent stem cell-derived hippocampal neurons originating from lithium-responsive patients. PDE11 is an enzyme uniquely enriched in the hippocampus that breaks down cyclic AMP and cyclic GMP. Here we determined whether decreasing PDE11A expression is sufficient to increase lithium responsivity in mice. In dorsal hippocampus and ventral hippocampus (VHIPP), lithium-responsive C57BL/6J and 129S6/SvEvTac mice show decreased PDE11A4 protein expression relative to lithium-unresponsive BALB/cJ mice. In VHIPP, C57BL/6J mice also show differences in PDE11A4 compartmentalization relative to BALB/cJ mice. In contrast, neither PDE2A nor PDE10A expression differ among the strains. The compartment-specific differences in PDE11A4 protein expression are explained by a coding single-nucleotide polymorphism (SNP) at amino acid 499, which falls within the GAF-B homodimerization domain. Relative to the BALB/cJ 499T, the C57BL/6J 499A decreases PDE11A4 homodimerization, which removes PDE11A4 from the membrane. Consistent with the observation that lower PDE11A4 expression correlates with better lithium responsiveness, we found that Pde11a knockout mice (KO) given 0.4% lithium chow for 3+ weeks exhibit greater lithium responsivity relative to wild-type (WT) littermates in tail suspension, an antidepressant-predictive assay, and amphetamine hyperlocomotion, an anti-manic predictive assay. Reduced PDE11A4 expression may represent a lithium-sensitive pathophysiology, because both C57BL/6J and Pde11a KO mice show increased expression of the pro-inflammatory cytokine interleukin-6 (IL-6) relative to BALB/cJ and PDE11A WT mice, respectively. Our finding that PDE11A4 negatively regulates lithium responsivity in mice suggests that the PDE11A SNPs identified in patients may be functionally relevant.