Angela Gu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Angela Gu has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- David M. Maahs
Department of Pediatrics, Stanford University, Stanford, CA, USA
3 shared publications - David Scheinker
Systems Utilization Research for Stanford Medicine Stanford University Stanford California USA
3 shared publications - Priya Prahalad
Division of Endocrinology, Department of Pediatrics, School of Medicine, Stanford University, Stanford, CA, USA
3 shared publications - Andrew Ward
Department of Electrical Engineering, Stanford University, Stanford, California
2 shared publications - Daniel Miller
Department of Management Science and Engineering Stanford University School of Engineering Stanford, CA United States
2 shared publications - Jeannine Leverenz
Lucile Packard Children’s Hospital, Division of Pediatric Endocrinology, Palo Alto, CA
2 shared publications
Latest Publications
- Open Access
- 6 June 2022
- Published by JMIR Publications Inc. in JMIR Diabetes
- Vol. 7 (2) , e27284
Algorithm-Enabled, Personalized Glucose Management for Type 1 Diabetes at the Population Scale: Prospective Evaluation in Clinical Practice
Background: The use of continuous glucose monitors (CGMs) is recommended as the standard of care by the American Diabetes Association for individuals with type 1 diabetes (T1D). Few hardware-agnostic, open-source, whole-population tools are available to facilitate the use of CGM data by clinicians such as physicians and certified diabetes educators. Objective: This study aimed to develop a tool that identifies patients appropriate for contact using an asynchronous message through electronic medical records while minimizing the number of patients reviewed by a certified diabetes educator or physician using the tool. Methods: We used consensus guidelines to develop timely interventions for diabetes excellence (TIDE), an open-source hardware-agnostic tool to analyze CGM data to identify patients with deteriorating glucose control by generating generic flags (eg, mean glucose [MG] >170 mg/dL) and personalized flags (eg, MG increased by >10 mg/dL). In a prospective 7-week study in a pediatric T1D clinic, we measured the sensitivity of TIDE in identifying patients appropriate for contact and the number of patients reviewed. We simulated measures of the workload generated by TIDE, including the average number of time in range (TIR) flags per patient per review period, on a convenience sample of eight external data sets, 6 from clinical trials and 2 donated by research foundations. Results: Over the 7 weeks of evaluation, the clinical population increased from 56 to 64 patients. The mean sensitivity was 99% (242/245; SD 2.5%), and the mean reduction in the number of patients reviewed was 42.6% (182/427; SD 10.9%). The 8 external data sets contained 1365 patients with 30,017 weeks of data collected by 7 types of CGMs. The rates of generic and personalized TIR flags per patient per review period were, respectively, 0.15 and 0.12 in the data set with the lowest average MG (141 mg/dL) and 0.95 and 0.22 in the data set with the highest average MG (207 mg/dL). Conclusions: TIDE is an open-source hardware-agnostic tool for personalized analysis of CGM data at the clinical population scale. In a pediatric T1D clinic, TIDE identified 99% of patients appropriate for contact using an asynchronous message through electronic medical records while reducing the number of patients reviewed by certified diabetes care and education specialists by 43%. For each of the 8 external data sets, simulation of the use of TIDE produced fewer than 0.25 personalized TIR flags per patient per review period. The use of TIDE to support telemedicine-based T1D care may facilitate sensitive and efficient guideline-based population health management.
- 6 June 2022
- Published by JMIR Publications Inc. in JMIR Diabetes
- Vol. 7 (2) , e27284
Open AccessAlgorithm-Enabled, Personalized Glucose Management for Type 1 Diabetes at the Population Scale: Prospective Evaluation in Clinical Practice
Background: The use of continuous glucose monitors (CGMs) is recommended as the standard of care by the American Diabetes Association for individuals with type 1 diabetes (T1D). Few hardware-agnostic, open-source, whole-population tools are available to facilitate the use of CGM data by clinicians such as physicians and certified diabetes educators. Objective: This study aimed to develop a tool that identifies patients appropriate for contact using an asynchronous message through electronic medical records while minimizing the number of patients reviewed by a certified diabetes educator or physician using the tool. Methods: We used consensus guidelines to develop timely interventions for diabetes excellence (TIDE), an open-source hardware-agnostic tool to analyze CGM data to identify patients with deteriorating glucose control by generating generic flags (eg, mean glucose [MG] >170 mg/dL) and personalized flags (eg, MG increased by >10 mg/dL). In a prospective 7-week study in a pediatric T1D clinic, we measured the sensitivity of TIDE in identifying patients appropriate for contact and the number of patients reviewed. We simulated measures of the workload generated by TIDE, including the average number of time in range (TIR) flags per patient per review period, on a convenience sample of eight external data sets, 6 from clinical trials and 2 donated by research foundations. Results: Over the 7 weeks of evaluation, the clinical population increased from 56 to 64 patients. The mean sensitivity was 99% (242/245; SD 2.5%), and the mean reduction in the number of patients reviewed was 42.6% (182/427; SD 10.9%). The 8 external data sets contained 1365 patients with 30,017 weeks of data collected by 7 types of CGMs. The rates of generic and personalized TIR flags per patient per review period were, respectively, 0.15 and 0.12 in the data set with the lowest average MG (141 mg/dL) and 0.95 and 0.22 in the data set with the highest average MG (207 mg/dL). Conclusions: TIDE is an open-source hardware-agnostic tool for personalized analysis of CGM data at the clinical population scale. In a pediatric T1D clinic, TIDE identified 99% of patients appropriate for contact using an asynchronous message through electronic medical records while reducing the number of patients reviewed by certified diabetes care and education specialists by 43%. For each of the 8 external data sets, simulation of the use of TIDE produced fewer than 0.25 personalized TIR flags per patient per review period. The use of TIDE to support telemedicine-based T1D care may facilitate sensitive and efficient guideline-based population health management.
- Open Access
- 20 January 2021
- Published by JMIR Publications Inc. in JMIR Preprints
Algorithm-Enabled, Personalized Glucose Management for Type 1 Diabetes at the Population Scale: Prospective Evaluation in Clinical Practice (Preprint)
BACKGROUND The use of continuous glucose monitors (CGMs) is recommended as the standard of care by the American Diabetes Association for individuals with type 1 diabetes (T1D). Few hardware-agnostic, open-source, whole-population tools are available to facilitate the use of CGM data by clinicians such as physicians and certified diabetes educators. OBJECTIVE This study aimed to develop a tool that identifies patients appropriate for contact using an asynchronous message through electronic medical records while minimizing the number of patients reviewed by a certified diabetes educator or physician using the tool. METHODS We used consensus guidelines to develop timely interventions for diabetes excellence (TIDE), an open-source hardware-agnostic tool to analyze CGM data to identify patients with deteriorating glucose control by generating generic flags (eg, mean glucose [MG] >170 mg/dL) and personalized flags (eg, MG increased by >10 mg/dL). In a prospective 7-week study in a pediatric T1D clinic, we measured the sensitivity of TIDE in identifying patients appropriate for contact and the number of patients reviewed. We simulated measures of the workload generated by TIDE, including the average number of time in range (TIR) flags per patient per review period, on a convenience sample of eight external data sets, 6 from clinical trials and 2 donated by research foundations. RESULTS Over the 7 weeks of evaluation, the clinical population increased from 56 to 64 patients. The mean sensitivity was 99% (242/245; SD 2.5%), and the mean reduction in the number of patients reviewed was 42.6% (182/427; SD 10.9%). The 8 external data sets contained 1365 patients with 30,017 weeks of data collected by 7 types of CGMs. The rates of generic and personalized TIR flags per patient per review period were, respectively, 0.15 and 0.12 in the data set with the lowest average MG (141 mg/dL) and 0.95 and 0.22 in the data set with the highest average MG (207 mg/dL). CONCLUSIONS TIDE is an open-source hardware-agnostic tool for personalized analysis of CGM data at the clinical population scale. In a pediatric T1D clinic, TIDE identified 99% of patients appropriate for contact using an asynchronous message through electronic medical records while reducing the number of patients reviewed by certified diabetes care and education specialists by 43%. For each of the 8 external data sets, simulation of the use of TIDE produced fewer than 0.25 personalized TIR flags per patient per review period. The use of TIDE to support telemedicine-based T1D care may facilitate sensitive and efficient guideline-based population health management.
- 20 January 2021
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessAlgorithm-Enabled, Personalized Glucose Management for Type 1 Diabetes at the Population Scale: Prospective Evaluation in Clinical Practice (Preprint)
BACKGROUND The use of continuous glucose monitors (CGMs) is recommended as the standard of care by the American Diabetes Association for individuals with type 1 diabetes (T1D). Few hardware-agnostic, open-source, whole-population tools are available to facilitate the use of CGM data by clinicians such as physicians and certified diabetes educators. OBJECTIVE This study aimed to develop a tool that identifies patients appropriate for contact using an asynchronous message through electronic medical records while minimizing the number of patients reviewed by a certified diabetes educator or physician using the tool. METHODS We used consensus guidelines to develop timely interventions for diabetes excellence (TIDE), an open-source hardware-agnostic tool to analyze CGM data to identify patients with deteriorating glucose control by generating generic flags (eg, mean glucose [MG] >170 mg/dL) and personalized flags (eg, MG increased by >10 mg/dL). In a prospective 7-week study in a pediatric T1D clinic, we measured the sensitivity of TIDE in identifying patients appropriate for contact and the number of patients reviewed. We simulated measures of the workload generated by TIDE, including the average number of time in range (TIR) flags per patient per review period, on a convenience sample of eight external data sets, 6 from clinical trials and 2 donated by research foundations. RESULTS Over the 7 weeks of evaluation, the clinical population increased from 56 to 64 patients. The mean sensitivity was 99% (242/245; SD 2.5%), and the mean reduction in the number of patients reviewed was 42.6% (182/427; SD 10.9%). The 8 external data sets contained 1365 patients with 30,017 weeks of data collected by 7 types of CGMs. The rates of generic and personalized TIR flags per patient per review period were, respectively, 0.15 and 0.12 in the data set with the lowest average MG (141 mg/dL) and 0.95 and 0.22 in the data set with the highest average MG (207 mg/dL). CONCLUSIONS TIDE is an open-source hardware-agnostic tool for personalized analysis of CGM data at the clinical population scale. In a pediatric T1D clinic, TIDE identified 99% of patients appropriate for contact using an asynchronous message through electronic medical records while reducing the number of patients reviewed by certified diabetes care and education specialists by 43%. For each of the 8 external data sets, simulation of the use of TIDE produced fewer than 0.25 personalized TIR flags per patient per review period. The use of TIDE to support telemedicine-based T1D care may facilitate sensitive and efficient guideline-based population health management.
- 1 June 2020
- Published by American Diabetes Association in Diabetes
- Vol. 69 (Supplement)
1294-P: Clinically Significant Hypoglycemia Is Rare in Youth with T1D during Partial Clinical Remission
Lower CGM glucose is typical after the diagnosis of T1D and the initiation of insulin treatment. Although ADA guidelines now state that glycemic targets can be lower during partial clinical remission (PCR), little guidance is offered on the optimal targets. We describe CGM glucose <70 mg/dL for youth wearing CGM by PCR status. We reviewed 201 visits from 67 records; 55 visits in PCR as defined by insulin dose adjusted A1C value <9 [(HbA1c at visit)*(4*units/kg/day)]. CGM data were collected 7 days before and after each visit. In multivariate regression, controlling for age, sex, and T1D duration, proportion of time spent <70 mg/dL was calculated in a 24-hour period and at nighttime (midnight to 6am). Our cohort is 40% female, aged 9.4±4.7 years, with 92±11% wear time, and T1D duration of 126±105 days. Time spent between 54-70 mg/dL was statistically higher at nighttime for those in PCR and the time spent <54 mg/dL was minimal for both (3.4±9.3 mins/24h, Table). There were no episodes of severe hypoglycemia. Clinically significant hypoglycemia (<54 mg/dl) is rare. Furthermore, youth in PCR have time <70 mg/dL similar to youth without T1D. A threshold alarm of 65 mg/dl may reduce hypoglycemia related alarms by 50% without increasing risk of severe hypoglycemia and warrants further study. These data support a trial of lower alarm thresholds for youth in PCR who wear CGM to avoid overtreatment of clinically insignificant lows. Disclosure: A. Addala: None. A. Gu: None. D. Zaharieva: Speaker’s Bureau; Self; Ascensia Diabetes Care, Insulet Corporation, Medtronic. P. Prahalad: None. B.A. Buckingham: Advisory Panel; Self; ConvaTec Inc., Medtronic. Research Support; Self; Beta Bionics, Inc., Dexcom, Inc., Insulet Corporation, Medtronic, Tandem Diabetes Care. D. Scheinker: None. D.M. Maahs: Advisory Panel; Self; Eli Lilly and Company, Insulet Corporation, Medtronic, Novo Nordisk A/S. Consultant; Self; Abbott, Sanofi. Research Support; Self; Bigfoot Biomedical, Dexcom, Inc., Roche Diabetes Care, Tandem Diabetes Care.
- 1 June 2020
- Published by American Diabetes Association in Diabetes
- Vol. 69 (Supplement)
1294-P: Clinically Significant Hypoglycemia Is Rare in Youth with T1D during Partial Clinical Remission
Lower CGM glucose is typical after the diagnosis of T1D and the initiation of insulin treatment. Although ADA guidelines now state that glycemic targets can be lower during partial clinical remission (PCR), little guidance is offered on the optimal targets. We describe CGM glucose <70 mg/dL for youth wearing CGM by PCR status. We reviewed 201 visits from 67 records; 55 visits in PCR as defined by insulin dose adjusted A1C value <9 [(HbA1c at visit)*(4*units/kg/day)]. CGM data were collected 7 days before and after each visit. In multivariate regression, controlling for age, sex, and T1D duration, proportion of time spent <70 mg/dL was calculated in a 24-hour period and at nighttime (midnight to 6am). Our cohort is 40% female, aged 9.4±4.7 years, with 92±11% wear time, and T1D duration of 126±105 days. Time spent between 54-70 mg/dL was statistically higher at nighttime for those in PCR and the time spent <54 mg/dL was minimal for both (3.4±9.3 mins/24h, Table). There were no episodes of severe hypoglycemia. Clinically significant hypoglycemia (<54 mg/dl) is rare. Furthermore, youth in PCR have time <70 mg/dL similar to youth without T1D. A threshold alarm of 65 mg/dl may reduce hypoglycemia related alarms by 50% without increasing risk of severe hypoglycemia and warrants further study. These data support a trial of lower alarm thresholds for youth in PCR who wear CGM to avoid overtreatment of clinically insignificant lows. Disclosure: A. Addala: None. A. Gu: None. D. Zaharieva: Speaker’s Bureau; Self; Ascensia Diabetes Care, Insulet Corporation, Medtronic. P. Prahalad: None. B.A. Buckingham: Advisory Panel; Self; ConvaTec Inc., Medtronic. Research Support; Self; Beta Bionics, Inc., Dexcom, Inc., Insulet Corporation, Medtronic, Tandem Diabetes Care. D. Scheinker: None. D.M. Maahs: Advisory Panel; Self; Eli Lilly and Company, Insulet Corporation, Medtronic, Novo Nordisk A/S. Consultant; Self; Abbott, Sanofi. Research Support; Self; Bigfoot Biomedical, Dexcom, Inc., Roche Diabetes Care, Tandem Diabetes Care.