Zhentao Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhentao Wu has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Xiaobing Pang
College of Environment, Zhejiang University of Technology, Hangzhou 310014, China
4 shared publications - Bo Xing
Shaoxing Ecological and Environmental Monitoring Center of Zhejiang Province, Shaoxing 312000, China
3 shared publications - Hai Wu
National Institute of Metrology, Beijing 102200, China
3 shared publications - Jianmeng Chen
College of Environment, Zhejiang University of Technology, Hangzhou, China
3 shared publications - Jingjing Li
Shaoxing Ecological and Environmental Monitoring Center of Zhejiang Province, Shaoxing 312000, China
3 shared publications - Kaibin Yuan
College of Environment, Zhejiang University of Technology, Hangzhou 310014, China
2 shared publications
Latest Publications
- Open Access
- 29 June 2023
- Published by MDPI AG in Atmosphere
- Vol. 14 (7) , 1093
Temporal Variations and Spatial Distribution of Air Pollutants in Shaoxing, a City in Yangtze Delta, China Based on Mobile Monitoring Using a Sensor Package
Currently, traffic-related sources are considered to be one of the major contributors to air pollutants in urban areas. As the number of motor vehicles increases, the impact of traffic-related air pollutants (TRAPs) on human health has also increased in recent years. People are easily exposed to TRAPs in their daily lives. However, long-term exposure to TRAPs can have adverse health effects. Mobile monitoring is more flexible compared to traditional urban monitoring stations and can effectively obtain the spatial variation characteristics of air pollutants. We mounted a sensor package on an electric bicycle and conducted mobile measurements of CO, NO2 and SO2 on a circular road in the center of Shaoxing, a city in the center of the Yangtze Delta, China. The CO, NO2 and SO2 concentrations were observed to be higher in the morning and evening rush hours, and the three pollutants show different seasonal and spatial variation characteristics. CO concentration was higher in urban arterial and crossroads. NO2 concentration was variable, alternating between high and low concentrations. SO2 concentration was relatively stable and aggregated. This study provides important information on the spatial and temporal variations of TRAPs, which helps commuters understand how to effectively reduce pollutant exposure during personal travel.
- 29 June 2023
- Published by MDPI AG in Atmosphere
- Vol. 14 (7) , 1093
Open AccessTemporal Variations and Spatial Distribution of Air Pollutants in Shaoxing, a City in Yangtze Delta, China Based on Mobile Monitoring Using a Sensor Package
Currently, traffic-related sources are considered to be one of the major contributors to air pollutants in urban areas. As the number of motor vehicles increases, the impact of traffic-related air pollutants (TRAPs) on human health has also increased in recent years. People are easily exposed to TRAPs in their daily lives. However, long-term exposure to TRAPs can have adverse health effects. Mobile monitoring is more flexible compared to traditional urban monitoring stations and can effectively obtain the spatial variation characteristics of air pollutants. We mounted a sensor package on an electric bicycle and conducted mobile measurements of CO, NO2 and SO2 on a circular road in the center of Shaoxing, a city in the center of the Yangtze Delta, China. The CO, NO2 and SO2 concentrations were observed to be higher in the morning and evening rush hours, and the three pollutants show different seasonal and spatial variation characteristics. CO concentration was higher in urban arterial and crossroads. NO2 concentration was variable, alternating between high and low concentrations. SO2 concentration was relatively stable and aggregated. This study provides important information on the spatial and temporal variations of TRAPs, which helps commuters understand how to effectively reduce pollutant exposure during personal travel.
- Open Access
- 12 January 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (2) , 1533
Development of a Portable and Sensitive CO2 Measurement Device with NDIR Sensor Clusters and Minimizing Water Vapor Impact
Increasing carbon dioxide (CO2) concentrations threaten human production and life. Currently the equipment used for CO2 monitoring is heavy and expensive, without a portable CO2 detector that is inexpensive and resistant to interference. Here we designed a portable CO2 detector based on no-dispersive infrared sensors to measure CO2 concentration. The detector, which has a mass of 1 kg, is powered by a lithium battery with dimensions of 200 mm (length) × 150 mm (width) × 100 mm (height). Considering the fact that field observations are susceptible to humidity, a series of experiments were carried out to reduce the humidity interference on sensor responses at a laboratory. The values of humidity and CO2 variation were used in a regression model analysis to determine a quadratic function with an R2 above 0.94. The detector was compared with a reference analyzer in ambient CO2 measurement during a 7-day field campaign in Hangzhou, China. After humidity correction, the data show better correlation with the reference data, with the R2 0.62–0.97 increasing from 0.62–0.97 compared to before the correction and the value deviation decreasing to less than 3%. Cluster analysis of sensors revealed a reduction in average relative deviation of up to 1.4% as the number of sensors increased.
- 12 January 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (2) , 1533
Open AccessDevelopment of a Portable and Sensitive CO2 Measurement Device with NDIR Sensor Clusters and Minimizing Water Vapor Impact
Increasing carbon dioxide (CO2) concentrations threaten human production and life. Currently the equipment used for CO2 monitoring is heavy and expensive, without a portable CO2 detector that is inexpensive and resistant to interference. Here we designed a portable CO2 detector based on no-dispersive infrared sensors to measure CO2 concentration. The detector, which has a mass of 1 kg, is powered by a lithium battery with dimensions of 200 mm (length) × 150 mm (width) × 100 mm (height). Considering the fact that field observations are susceptible to humidity, a series of experiments were carried out to reduce the humidity interference on sensor responses at a laboratory. The values of humidity and CO2 variation were used in a regression model analysis to determine a quadratic function with an R2 above 0.94. The detector was compared with a reference analyzer in ambient CO2 measurement during a 7-day field campaign in Hangzhou, China. After humidity correction, the data show better correlation with the reference data, with the R2 0.62–0.97 increasing from 0.62–0.97 compared to before the correction and the value deviation decreasing to less than 3%. Cluster analysis of sensors revealed a reduction in average relative deviation of up to 1.4% as the number of sensors increased.
- Open Access
- 22 December 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 20 (1) , 168
Temporal Characteristics of Ozone (O3) in the Representative City of the Yangtze River Delta: Explanatory Factors and Sensitivity Analysis
Ozone (O3) has attracted considerable attention due to its harmful effects on the ecosystem and human health. The Yangtze River Delta (YRD), China in particular has experienced severe O3 pollution in recent years. Here, we conducted a long-term observation of O3 in YRD to reveal its characteristics. The O3 concentration in autumn was the highest at 72.76 ppb due to photochemical contribution and local convection patterns, with its lowest value of 2.40 ppb in winter. O3 exhibited strong diurnal variations, showing the highest values in the early afternoon (15:00–16:00) and the minimum in 07:00–08:00, specifically, peroxyacetyl nitrate (PAN) showed similar variations to O3 but PAN peak usually occurred 1 h earlier than that of O3 due to PAN photolysis. A generalized additive model indicated that the key factors to O3 formation were NO2, PAN, and temperature. It was found that a certain temperature rise promoted O3 formation, whereas temperatures above 27 °C inhibited O3 formation. An observation-based model showed O3 formation was VOCs-limited in spring and winter, was NOx-limited in summer, and even controlled by both VOCs and NOx in autumn. Thus, prevention and control strategies for O3 in the YRD are strongly recommended to be variable for each season based on various formation mechanisms.
- 22 December 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 20 (1) , 168
Open AccessTemporal Characteristics of Ozone (O3) in the Representative City of the Yangtze River Delta: Explanatory Factors and Sensitivity Analysis
Ozone (O3) has attracted considerable attention due to its harmful effects on the ecosystem and human health. The Yangtze River Delta (YRD), China in particular has experienced severe O3 pollution in recent years. Here, we conducted a long-term observation of O3 in YRD to reveal its characteristics. The O3 concentration in autumn was the highest at 72.76 ppb due to photochemical contribution and local convection patterns, with its lowest value of 2.40 ppb in winter. O3 exhibited strong diurnal variations, showing the highest values in the early afternoon (15:00–16:00) and the minimum in 07:00–08:00, specifically, peroxyacetyl nitrate (PAN) showed similar variations to O3 but PAN peak usually occurred 1 h earlier than that of O3 due to PAN photolysis. A generalized additive model indicated that the key factors to O3 formation were NO2, PAN, and temperature. It was found that a certain temperature rise promoted O3 formation, whereas temperatures above 27 °C inhibited O3 formation. An observation-based model showed O3 formation was VOCs-limited in spring and winter, was NOx-limited in summer, and even controlled by both VOCs and NOx in autumn. Thus, prevention and control strategies for O3 in the YRD are strongly recommended to be variable for each season based on various formation mechanisms.
- Open Access
Direct Measuring Particulate Matters in Smoke Plumes from Chimneys in a Textile Dyeing Industrial Park by a Self-Developed PM Detector on an UAV in Yangtze River Delta of China
Directly measuring particulate matters (PM) from chimneys in an industrial park is difficult due to it being hard to reach the peak heights. A self-developed PM detector on an unmanned aerial vehicle (UAV) had been deployed to directly measure the PM emissions in smoke plumes from chimneys in a textile dyeing industrial park. Compared with a commercial PM device (LD-5R, SIBATA, Kyoto, Japan), the self-developed detector showed similar performance with a good correlation (R2 varying from 0.911 to 0.951) in simultaneously vertical PM measurements on UAV. The PM emissions from chimneys after different textile treating processes, including pigment printing, dyeing process, and digital printing, were investigated. PM mass concentrations and particle number concentrations (PNC) in different sizes were found to be significantly higher in pigment printing than those in dyeing process and digital printing by 2 or 3 times after electrostatic precipitation. The activated carbon adsorption and electrostatic precipitation were the major PM controlling techniques in the park. The PM mass concentrations and PNC were the highest in the process of dyeing after activated carbon adsorption with the concentrations of PM1 (1000 μg·m−3), PM2.5 (1600 μg·m−3), and PM10 (2000 μg·m−3), respectively. According to the results of PM and PNC, PM2.5 was found to be the dominant particles accounting for 99% of the PM emissions. It may be due to the high temperature in thermo-fixing machine, which is beneficial to the PM2.5 generation. This study revealed PM2.5 was the dominant particles to be reduced in textile dyeing enterprises to mitigate PM pollution.
Open AccessDirect Measuring Particulate Matters in Smoke Plumes from Chimneys in a Textile Dyeing Industrial Park by a Self-Developed PM Detector on an UAV in Yangtze River Delta of China
Directly measuring particulate matters (PM) from chimneys in an industrial park is difficult due to it being hard to reach the peak heights. A self-developed PM detector on an unmanned aerial vehicle (UAV) had been deployed to directly measure the PM emissions in smoke plumes from chimneys in a textile dyeing industrial park. Compared with a commercial PM device (LD-5R, SIBATA, Kyoto, Japan), the self-developed detector showed similar performance with a good correlation (R2 varying from 0.911 to 0.951) in simultaneously vertical PM measurements on UAV. The PM emissions from chimneys after different textile treating processes, including pigment printing, dyeing process, and digital printing, were investigated. PM mass concentrations and particle number concentrations (PNC) in different sizes were found to be significantly higher in pigment printing than those in dyeing process and digital printing by 2 or 3 times after electrostatic precipitation. The activated carbon adsorption and electrostatic precipitation were the major PM controlling techniques in the park. The PM mass concentrations and PNC were the highest in the process of dyeing after activated carbon adsorption with the concentrations of PM1 (1000 μg·m−3), PM2.5 (1600 μg·m−3), and PM10 (2000 μg·m−3), respectively. According to the results of PM and PNC, PM2.5 was found to be the dominant particles accounting for 99% of the PM emissions. It may be due to the high temperature in thermo-fixing machine, which is beneficial to the PM2.5 generation. This study revealed PM2.5 was the dominant particles to be reduced in textile dyeing enterprises to mitigate PM pollution.