Dawn Idoko
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dawn Idoko has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Amirmasoud Amirkabiri
Department of Electrical and Computer Engineering, University of Manitoba, Winnipeg, MB, Canada
2 shared publications - Behzad Kordi
Department of Electrical and Computer Engineering, University of Manitoba, Winnipeg, MB, Canada
2 shared publications - Greg E. Bridges
Department of Electrical and Computer Engineering, University of Manitoba, Winnipeg, Manitoba, Canada
2 shared publications
Latest Publications
- Open Access
Chipless RFID Sensor for Measuring Time-Varying Electric Fields Using a Contactless Air-Filled Substrate-Integrated Waveguide Resonator
This paper presents a wireless chipless resonator-based sensor for measuring the absolute value of an external time-varying electric field. The sensor is developed using contactless air-filled substrate-integrated waveguide (CLAF-SIW) technology. The sensor employs a low-impedance electromagnetic band gap structure to confine the electric field within the sensor’s air cavity. The air cavity is loaded with varactor diodes whose reverse bias voltage is modified by the to-be-measured external electric field. Variation in the external electric field results in a variation of the sensor’s resonant frequency. The CLAF-SIW sensor offers a high unloaded quality factor, which is required for a long-distance ringback-based interrogation system. A prototype of the proposed sensor is fabricated and tested. It can measure a time-varying external electric field up to kV/m, has a sensitivity of (kHz)/(V/m), and can be interrogated from a distance of 80 cm. The feasible maximum bandwidth of the external electric field is 25 kHz. The proposed sensor offers a compact planar multilayer structure that can easily be incorporated with a planar antenna and its size can be reduced by selecting a higher operating frequency without an increase in dielectric loss.Open AccessChipless RFID Sensor for Measuring Time-Varying Electric Fields Using a Contactless Air-Filled Substrate-Integrated Waveguide Resonator
This paper presents a wireless chipless resonator-based sensor for measuring the absolute value of an external time-varying electric field. The sensor is developed using contactless air-filled substrate-integrated waveguide (CLAF-SIW) technology. The sensor employs a low-impedance electromagnetic band gap structure to confine the electric field within the sensor’s air cavity. The air cavity is loaded with varactor diodes whose reverse bias voltage is modified by the to-be-measured external electric field. Variation in the external electric field results in a variation of the sensor’s resonant frequency. The CLAF-SIW sensor offers a high unloaded quality factor, which is required for a long-distance ringback-based interrogation system. A prototype of the proposed sensor is fabricated and tested. It can measure a time-varying external electric field up to kV/m, has a sensitivity of (kHz)/(V/m), and can be interrogated from a distance of 80 cm. The feasible maximum bandwidth of the external electric field is 25 kHz. The proposed sensor offers a compact planar multilayer structure that can easily be incorporated with a planar antenna and its size can be reduced by selecting a higher operating frequency without an increase in dielectric loss. - 7 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 70 (7) , 3724-3731
Contactless Air-Filled Substrate-Integrated Waveguide (CLAF-SIW) Resonator for Wireless Passive Temperature Sensing
In this article a wireless passive temperature sensor is designed, fabricated, and tested. The sensor uses a contactless air-filled substrate-integrated waveguide (CLAF-SIW) resonator that consists of an air cavity surrounded by a low-impedance electromagnetic band gap (EBG) structure. The contactless feature of the sensor mitigates the fabrication complexity issue of air-filled SIW (AF-SIW) while it benefits from the high-quality factor of an air-filled resonator. The resonant frequency of the CLAF-SIW resonator is dependent on the permittivity of the substrate and the dimensions of the structure which are both temperature-dependent. Change in temperature results in a variation in the resonant frequency of the sensor. As such, we measure temperature by measuring the resonant frequency of the sensor. The developed CLAF-SIW sensor has a measured unloaded quality factor of 1340 that allows for long-range wireless measurements. The resonant frequency of the sensor is measured using a ringback-based wireless interrogation system. The interrogation system energizes the sensor using radio frequency (RF) pulses and determines the frequency of the ringback signals radiated by the sensor using frequency domain analysis. The sensor has a sensitivity of 300 kHz/ $^\circ \text{C}$ and an interrogation-to-sensor distance of 80cm.
- 7 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 70 (7) , 3724-3731
Contactless Air-Filled Substrate-Integrated Waveguide (CLAF-SIW) Resonator for Wireless Passive Temperature Sensing
In this article a wireless passive temperature sensor is designed, fabricated, and tested. The sensor uses a contactless air-filled substrate-integrated waveguide (CLAF-SIW) resonator that consists of an air cavity surrounded by a low-impedance electromagnetic band gap (EBG) structure. The contactless feature of the sensor mitigates the fabrication complexity issue of air-filled SIW (AF-SIW) while it benefits from the high-quality factor of an air-filled resonator. The resonant frequency of the CLAF-SIW resonator is dependent on the permittivity of the substrate and the dimensions of the structure which are both temperature-dependent. Change in temperature results in a variation in the resonant frequency of the sensor. As such, we measure temperature by measuring the resonant frequency of the sensor. The developed CLAF-SIW sensor has a measured unloaded quality factor of 1340 that allows for long-range wireless measurements. The resonant frequency of the sensor is measured using a ringback-based wireless interrogation system. The interrogation system energizes the sensor using radio frequency (RF) pulses and determines the frequency of the ringback signals radiated by the sensor using frequency domain analysis. The sensor has a sensitivity of 300 kHz/ $^\circ \text{C}$ and an interrogation-to-sensor distance of 80cm.