ACAndrea Nallely Garza Cisneros

Andrea Nallely Garza Cisneros

*This is an algorithmically generated author record based on publicly available information.

Andrea Nallely Garza Cisneros has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Large incarcerated inguinoscrotal type I Amyand's hernia managed with appendix preserving Lichtenstein mesh repair: a case report

    by Sergio Miguel Suárez Fuentes, Mauro Axel Cárdenas Rosales, Luis Fernando Hernández González, Valeria Gómez Márquez, Jazmin Saenz Lopez, Andrea Nallely Garza Cisneros, Ricardo Yamil Topete De Robles, José Julián Cervantes de Anda, Luis Manuel García Bravo

    Amyand's hernia is the presence of the vermiform appendix within an inguinal hernia sac and represents an uncommon intraoperative finding whose management depends on appendiceal viability and operative-field contamination. We report a 70-year-old man with a six-week history of a right inguinal hernia who developed one week of progressive inguinoscrotal enlargement, pain rated 8/10, and absence of bowel movements despite preserved flatus. Examination showed a large, firm, nonreducible right inguinoscrotal hernia without skin inflammatory changes or clinical peritonitis. Plain pelvic radiographs demonstrated marked right hemiscrotal enlargement with bowel-containing herniation. Because urgent surgery was indicated, no ultrasonography or computed tomography was obtained. Open exploration revealed a large indirect inguinoscrotal sac measuring approximately 15 × 10 cm. Controlled opening demonstrated the cecum and a macroscopically normal appendix without inflammation, ischemia, perforation, or contamination, establishing a Losanoff-Basson Type I Amyand's hernia. The appendix was preserved and reduced, the redundant sac was resected, and a tension-free Lichtenstein repair with polypropylene mesh was completed. Recovery was uncomplicated. At two-week follow-up, there was no edema, clinical recurrence, testicular abnormality, or other identified complication. This case illustrates that urgent symptoms and large scrotal extension do not necessarily imply appendiceal inflammation and supports a contamination-directed strategy in which a normal appendix may be preserved while definitive prosthetic hernia repair is performed.

  • Open Access

    Artificial intelligence in plastic and reconstructive surgery: clinical applications, translational readiness and barriers to real-world implementation

    by Sergio Miguel Suárez Fuentes, Mauro Axel Cárdenas Rosales, Andrea Nallely Garza Cisneros, Martin Sergio Rodríguez Garza, Luis Fernando Hernández González, Valeria Gómez Márquez, Nora Lis Flores Olmos

    Artificial intelligence (AI) is expanding rapidly in plastic and reconstructive surgery, but the central question has shifted from whether an algorithm can perform a task to whether it can generalize, improve clinical decisions, and remain safe after deployment. This critical review examines contemporary AI applications in burn assessment, facial and craniofacial surgery, microsurgical free-flap monitoring, breast reconstruction, and patient communication, with emphasis on translational readiness rather than cataloguing technologies. A structured PubMed/MEDLINE search through September 6, 2026 was supplemented by reference chaining from recent systematic reviews and reporting guidance. Image-based systems have reached high performance for selected bounded tasks, including automated free-flap monitoring (area under the curve 0.960), burn-depth assessment (95% accuracy in a prospective clinical cohort), and some externally validated breast-reconstruction outcome models (area under the curve up to 0.97). In contrast, prediction of multifactorial complications remains less discriminative, and general-purpose large language models have shown clinically important limitations in factual accuracy and postoperative triage. The principal barrier is therefore not algorithm development but clinical translation: external validation, prospective impact studies, subgroup performance, human-AI workflow design, data governance, and post-deployment monitoring remain inconsistently addressed. Plastic surgery is well positioned to benefit from AI because it is image-rich and outcome-sensitive, but implementation should prioritize narrowly defined tasks with measurable clinical value and preserve surgeon oversight, patient-reported outcomes, and transparent lifecycle governance.

  • Subclinical systolic dysfunction by speckle tracking echocardiography in patients with systemic lupus erythematosus

    by Jose R Azpiri-Lopez, Dionicio A Galarza-Delgado, Andrea N Garza-Cisneros, Natalia Guajardo-Jauregui, Mario A Balderas-Palacios, Alexis Garcia-Heredia, Jesus A Cardenas-De la Garza, Alejandra B Rodriguez-Romero, Roberto A Reyna-De la Garza, Hernan Azpiri-Diaz, et al.

    Background: We aimed to compare the prevalence of subclinical left ventricular systolic dysfunction in Hispanic systemic lupus erythematosus (SLE) patients versus healthy controls. Material and methods: This cross-sectional study included 46 SLE patients who fulfilled the 2019 European League Against Rheumatism and American College of Rheumatology (EULAR/ACR) classification criteria for SLE and with age ≥ 18 years. For comparison, we included a control group with 46 non-SLE subjects matched by age (±5 years) and gender. A transthoracic echocardiogram was performed on every participant. The echocardiographic measurements evaluated were left ventricular ejection fraction (LVEF), relative wall thickness (RWT), and tricuspid annular plane systolic excursion (TAPSE). Left ventricular-Global Longitudinal Strain (GLS) was evaluated, and a value higher than −18% was classified as subclinical left ventricular systolic dysfunction. Comparisons between groups were made using the Chi-square test or Fisher’s exact test for qualitative variables, and Student’s t-test or the Mann–Whitney’s U test for quantitative variables. A p-value <.05 was considered significant. Results: We found a significant difference in the presence of subclinical left ventricular systolic dysfunction between SLE-patients and controls (37.0% vs 8.7%, p = .001). We also found that SLE patients had a lower left ventricular GLS (−18.90% vs −20.51%, p = .011), TAPSE (21.63 mm vs 23.60 mm, p = .009), and LVEF (57.17% vs 62.47%, p = <.001) than controls. Systemic lupus erythematosus diagnosis was independently associated with the presence of subclinical left ventricular systolic dysfunction with an OR of 6.068 (CI 95% 1.675−21.987) ( p = .006). Subclinical systolic dysfunction was more common in men (29.4% vs 3.4%, p = .020), patients with obesity (17.6% vs 0%, p = .045), or hypertension (47.1% vs 6.9%, p = .001). Conclusion: Systemic lupus erythematosus Hispanic patients had a higher prevalence of subclinical left ventricular systolic dysfunction, and worse left ventricular GLS, LVEF, and TAPSE values than matched healthy controls. Additionally, we found that male gender, obesity, and hypertension are associated with the presence of subclinical left ventricular systolic dysfunction in SLE patients. The inclusion of speckle tracking echocardiography as part of the cardiovascular evaluation of SLE patients may help identify high cardiovascular risk patients.


  • Cost-effective Solution for Maxillofacial Reconstruction Surgery with Virtual Surgical Planning and 3D Printed Cutting Guides Reduces Operative Time

    by Andrea Nallely Garza-Cisneros, Mauricio Manuel García-Pérez, William Josef Rodriguez-Guajardo, Guillermo Elizondo-Riojas, Adrian A. Negreros-Osuna

    Background: This study aimed to explore a low-cost solution for virtual surgical planning/3D printed surgical guides in a training hospital, assessing the impact on intraoperative time and bleeding. Material and Methods: We included a total of 13 patients. 8 who underwent maxillofacial reconstruction surgery with fibula-free flap utilizing virtual surgical planning/3D printed guides (VP/SG), and 5 using conventional surgery (CS) from 2017 to 2020. The surgical time, bleeding, length of hospital stay, and comorbidities were collected and compared in two groups. We recorded the average cost for the complete surgical planning and 3D printed guides. We applied a qualitative survey to the surgeons involved in the surgical procedures. Results The mean surgical time in the VP/SG group was 8.16 ± 2.7, compared to the CS group 12.5 ± 3.8, showing a 4.34 hours difference with statistical significance (p = 0.033). Patients from the CS group had a higher bleeding volume of 921 ± 467.6 mL VS 760 ± 633.8 mL in the VP/SG group. The average cost for the complete surgical planning and 3D printed guides was 914.44 ± 46.39 USD. All the surgeons who answered the survey preferred to perform the procedure utilizing the virtual planning/3D printed guides. Conclusions Virtual planning and 3D printed surgical guides have the potential to reduce operation time in maxillofacial reconstruction.