Qing Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Qing Li has a total of 90 co-authors. Here are the top co-authors by number of shared publications:
Rui-Qi Liu
National Gravitation Laboratory, MOE Key Laboratory of Fundamental Physical Quantities Measurement, and School of Physics, Huazhong University of Science and Technology, Wuhan 430074, People’s Republic of China
5 shared publications- Ruiqi Liu
Huazhong University of Science and Technology
5 shared publications Tong Huang
Huazhong University of Science and Technology
5 shared publicationsLingling Yang
Huazhong University of Science and Technology
4 shared publications- Lingling Yang
Huazhong University of Science and Technology
4 shared publications Qiangbing Mao
4 shared publications
Latest Publications
- 28 September 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (39) , 395002
Measurement of dissipation-coupling mechanisms in a two-stage pendulum system for gravitational experiment
A two-stage pendulum system, comprising a lower torsion pendulum and an upper torsion pendulum, is widely employed in gravitational experiments. While prior research has focused primarily on the vibration isolation capability of the magnetic damper, this study investigates the dissipation coupling mechanism between the upper and lower torsion pendulums through theoretical analysis and experimental validation. The dynamic model of the two-stage pendulum system is analyzed, and expressions for the quality factor (hereafter denoted as Q value) of each stage are derived. An experimental apparatus is designed and constructed to enable modulation of the Q value of the upper torsion pendulum and then measure the response of the lower torsion pendulum. Results indicate that when the horizontal magnetic field at the center of the upper torsion pendulum is increased from 1.37 to 20.63 mT, the Q value of the upper torsion pendulum decreases from 701 to 7, which leads to a reduction in the Q value of the lower torsion pendulum—from 1.6 × 10 5 to 9.0 × 10 4 . In gravitational experiments with a silica fiber, after using the magnetic damper, the Q value of the lower torsion pendulum can be reduced by approximately half, which results in an increase in thermal noise. This work offers valuable insights into the dissipation coupling mechanism of a two-stage pendulum system and aids in assessing noise sources in precision measurements.
- 28 September 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (39) , 395002
Measurement of dissipation-coupling mechanisms in a two-stage pendulum system for gravitational experiment
A two-stage pendulum system, comprising a lower torsion pendulum and an upper torsion pendulum, is widely employed in gravitational experiments. While prior research has focused primarily on the vibration isolation capability of the magnetic damper, this study investigates the dissipation coupling mechanism between the upper and lower torsion pendulums through theoretical analysis and experimental validation. The dynamic model of the two-stage pendulum system is analyzed, and expressions for the quality factor (hereafter denoted as Q value) of each stage are derived. An experimental apparatus is designed and constructed to enable modulation of the Q value of the upper torsion pendulum and then measure the response of the lower torsion pendulum. Results indicate that when the horizontal magnetic field at the center of the upper torsion pendulum is increased from 1.37 to 20.63 mT, the Q value of the upper torsion pendulum decreases from 701 to 7, which leads to a reduction in the Q value of the lower torsion pendulum—from 1.6 × 10 5 to 9.0 × 10 4 . In gravitational experiments with a silica fiber, after using the magnetic damper, the Q value of the lower torsion pendulum can be reduced by approximately half, which results in an increase in thermal noise. This work offers valuable insights into the dissipation coupling mechanism of a two-stage pendulum system and aids in assessing noise sources in precision measurements.
- Open Access
- 11 August 2026
- Published by Taylor & Francis in International Journal of Smart and Nano Materials
- Vol. 17 (1)
A triboelectric nanogenerator sensor-based capture, positioning and release mechanism (CPRM) for test mass in TianQin Gravitational Wave detection Project
1. GW detection provides an important observational approach for investigating the origin of the Universe and extreme astrophysical processes, such as black hole mergers and neutron star collisions...
- 11 August 2026
- Published by Taylor & Francis in International Journal of Smart and Nano Materials
- Vol. 17 (1)
Open AccessA triboelectric nanogenerator sensor-based capture, positioning and release mechanism (CPRM) for test mass in TianQin Gravitational Wave detection Project
1. GW detection provides an important observational approach for investigating the origin of the Universe and extreme astrophysical processes, such as black hole mergers and neutron star collisions...
- 9 March 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 25 (3)
Micrometer-diameter high- Q silica fiber from a laser-based pulling machine for a milligram-scale torsion pendulum
- 9 March 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 25 (3)
Micrometer-diameter high- Q silica fiber from a laser-based pulling machine for a milligram-scale torsion pendulum
- 5 February 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 25 (2)
Torsion-balance-based method for calibrating angle encoders in gravitational experiments
- 5 February 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 25 (2)
Torsion-balance-based method for calibrating angle encoders in gravitational experiments
- 16 October 2025
- Published by Springer Nature
- p. 141-145
Measurement Scheme of Release Impulse Based on a Compound Pendulum for the TianQin Project
- 16 October 2025
- Published by Springer Nature
- p. 141-145
Measurement Scheme of Release Impulse Based on a Compound Pendulum for the TianQin Project
- 16 October 2025
- Published by Springer Nature
- p. 147-151
The Measurement of Release Impulse and Impulse Moment with Different Types of Pendulums on the Ground
- 16 October 2025
- Published by Springer Nature
- p. 147-151
The Measurement of Release Impulse and Impulse Moment with Different Types of Pendulums on the Ground
- 19 August 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (9)
Progress on measurement of gravitational constant G
The gravitational constant G was the second fundamental constant to be measured. However, it exhibits the lowest measurement precision among all fundamental physical constants. The latest CODATA-2022 recommended value of G is 6.67430(15)×10−11m3kg−1s−2, with a relative standard uncertainty of 22 ppm. Over the past two centuries, the precision of G measurements has increased by only approximately three orders of magnitude. In this article, we first introduce the historical development of G measurements. Next, we compare the determinations of G obtained using different methods and instruments across various experimental setups, analyzing their respective advantages and disadvantages. Finally, we briefly discuss the temporal variation of G and the error sources in measurement of G.
- 19 August 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (9)
Progress on measurement of gravitational constant G
The gravitational constant G was the second fundamental constant to be measured. However, it exhibits the lowest measurement precision among all fundamental physical constants. The latest CODATA-2022 recommended value of G is 6.67430(15)×10−11m3kg−1s−2, with a relative standard uncertainty of 22 ppm. Over the past two centuries, the precision of G measurements has increased by only approximately three orders of magnitude. In this article, we first introduce the historical development of G measurements. Next, we compare the determinations of G obtained using different methods and instruments across various experimental setups, analyzing their respective advantages and disadvantages. Finally, we briefly discuss the temporal variation of G and the error sources in measurement of G.
- 18 August 2025
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 24 (2)
Amplitude dependence of value in a gravitational experiment with fused silica fiber- 18 August 2025
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 24 (2)
Amplitude dependence of value in a gravitational experiment with fused silica fiber- 30 April 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 111 (7)
Detecting interactions mediated by axions with a milligram-scale torsion pendulum
- 30 April 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 111 (7)
Detecting interactions mediated by axions with a milligram-scale torsion pendulum
- 4 April 2025
- Published by Elsevier in Measurement
- Vol. 253
Diameter measurement of silicon sphere at nanometer level with laser interferometry in measurement of gravitational constant
- 4 April 2025
- Published by Elsevier in Measurement
- Vol. 253
Diameter measurement of silicon sphere at nanometer level with laser interferometry in measurement of gravitational constant