WHWen-Chieh Hsu

Wen-Chieh Hsu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Wen-Chieh Hsu has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Promoting Surface Energy and Osteoblast Viability on Zirconia Implant Abutments Through Glass–Ceramic Spray Deposition Technology

    by Wen-Chieh Hsu, Tao-Yu Cha, Yu-Chin Yao, Chien-Ming Kang, Sheng-Han Wu, Yuichi Mine, Chien-Fu Tseng, I-Ta Lee, Dan-Jae Lin, Tzu-Yu Peng

    Zirconia is used widely for high-precision custom abutments; however, stress concentration can compromise osseointegration. Although glass–ceramic spray deposition (GCSD) can enhance the surface properties of zirconia, its biological effects remain unclear. In this study, the biological responses of human osteoblast-like (MG-63) cells to GCSD-modified zirconia surfaces were evaluated to assess the potential application in zirconia abutments. Disk-shaped zirconia and titanium alloy samples were prepared; titanium served as the control (Ti). Zirconia was subjected to polishing (NT), airborne-particle abrasion (AB), or GCSD with (GE) or without (GC) hydrofluoric acid (HF) etching. Surface characteristics, including wettability, surface energy (SE), and surface potential (SP), were analyzed. Cytotoxicity and MG-63 cell adhesion were assessed using the PrestoBlue assay, scanning electron microscopy (SEM), viability staining, and confocal laser scanning microscopy (CLSM). Statistical analysis was performed with a significance level of 0.05. GCSD produced a dense glass–ceramic coating on the zirconia surface, which significantly enhanced hydrophilicity as indicated by reduced water contact angles and increased SE in the GC and GE groups (p < 0.05). HF etching increased SP (p < 0.05). No cytotoxicity was observed in any group. SEM, viability staining, and CLSM revealed enhanced MG-63 cell attachment on Ti and GE surfaces and the highest viability ratio in the GE group. The NT group exhibited the lowest cell attachment and viability at all time points. GCSD effectively improved zirconia abutment surface properties by enhancing hydrophilicity and promoting MG-63 cell adhesion, with biocompatibility comparable to or better than that of titanium.


  • Open Access

    Evaluating the Effect of Different Polymer and Composite Abutments on the Color Accuracy of Multilayer Pre-Colored Zirconia Polycrystal Dental Prosthesis

    by Wen-Chieh Hsu, Tzu-Yu Peng, Chien-Ming Kang, Fan-Yi Chao, Jian-Hong Yu, Su-Feng Chen

    With increasing aesthetic awareness and emphasis on time costs in today’s society, monolithic multilayer precolored zirconia ceramics (M-Zr) facilitate aesthetic restorations in a convenient and straightforward manner without the need for veneering porcelain to modify the color. However, the effect of abutment materials on the final color of M-Zr remains unclear. Herein, we placed Vita A1 Shade M-Zr on six different abutment materials, zirconia (Y-TZP), 3D printed composite resin (CR), dental model resin (MR), polyetheretherketone (PEEK), polyetherketoneketone (PEKK), and cobalt–chromium alloy (Co–Cr), to evaluate their effect on the color accuracy of M-Zr. The color attributes (L*, a*, and b*) were measured using a dental spectrophotometer. The translucency parameter (TP), contrast ratio, color difference (ΔE) between each background substrate and the Vita A1 Shade Guide, and chroma values (C) were calculated to evaluate the color accuracy of M-Zr. A statistical analysis was performed using one-way analysis of variance and post hoc Tukey’s HSD tests (α = 0.05). The experimental results indicate that the TP values and contrast ratio of the M-Zr samples were 14.85 and 0.83, respectively. Co–Cr had the highest ΔE (6.08) and lowest C value (7.52); PEKK had the lowest ΔE (2.60), and PEEK had the highest C value (12.23) (p < 0.05). Notably, the ΔE values of CR (3.13), PEEK (2.86), and PEKK were within clinical indicators (ΔE < 3.7). Based on these results, it can be concluded that the abutment material has a significant effect on the final color of the M-Zr, and PEEK or PEKK resulted in good color accuracy. When choosing the dental MR, traditional zirconia, or metals as abutment materials, colored or opaque cement might be required to eliminate color distortion and achieve desirable optical properties.