Guoqing An
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Guoqing An has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Jiale Guo
School of Electrical Engineering, Hebei University of Science and Technology, Shijiazhuang 050018, China
2 shared publications - Long Zhang
Shijiazhuang Tonhe Electronics Technologies Co., Ltd., Shijiazhuang 050035, China
2 shared publications - Rui Li
Shijiazhuang Tonhe Electronics Technologies Co., Ltd., Shijiazhuang 050035, China
2 shared publications - Zibo Yang
School of Electrical Engineering, Hebei University of Science and Technology, Shijiazhuang 050018, China
2 shared publications - Hexu Sun
School of Electrical Engineering, Hebei University of Science and Technology, Shijiazhuang 050018, China
1 shared publication - Jiawei Liu
School of Electrical Engineering, Hebei University of Science and Technology, Shijiazhuang 050018, China
1 shared publication
Latest Publications
- Open Access
- 12 January 2026
- Published by MDPI AG in Mathematical and Computational Applications
- Vol. 31 (1) , 12
Performance Defect Identification in Switching Power Supplies Based on Multi-Strategy-Enhanced Dung Beetle Optimizer
To address the limited defect-detection capability of existing performance testing methods for switching power supplies under varying operating conditions, this paper proposes a defect identification approach based on an enhanced Dung Beetle Optimizer. The algorithm integrates multi-strategy improvements—including piecewise chaotic mapping, Lévy flight perturbation, hybrid sine–cosine updating, and an alert sparrow mechanism—to refine the initial population generation, position update rules, and late-stage exploration. These enhancements strengthen its spatial search ability and computational performance. The experimental results show that the method accurately identifies the predefined defect intervals with a precision of 94.79%, covering 91.3% of the operating conditions. Comparisons with existing mainstream methods confirm the superior performance, effectiveness, and feasibility of the proposed method.
- 12 January 2026
- Published by MDPI AG in Mathematical and Computational Applications
- Vol. 31 (1) , 12
Open AccessPerformance Defect Identification in Switching Power Supplies Based on Multi-Strategy-Enhanced Dung Beetle Optimizer
To address the limited defect-detection capability of existing performance testing methods for switching power supplies under varying operating conditions, this paper proposes a defect identification approach based on an enhanced Dung Beetle Optimizer. The algorithm integrates multi-strategy improvements—including piecewise chaotic mapping, Lévy flight perturbation, hybrid sine–cosine updating, and an alert sparrow mechanism—to refine the initial population generation, position update rules, and late-stage exploration. These enhancements strengthen its spatial search ability and computational performance. The experimental results show that the method accurately identifies the predefined defect intervals with a precision of 94.79%, covering 91.3% of the operating conditions. Comparisons with existing mainstream methods confirm the superior performance, effectiveness, and feasibility of the proposed method.
- Open Access
- 28 September 2025
- Published by MDPI AG in Journal of Low Power Electronics and Applications
- Vol. 15 (4) , 57
Research on Frequency Characteristic Fitting of LLC Switching-Mode Power Supply Under All Operating Conditions Based on FT-WOA-MLP
The frequency characteristics of the switching-mode power supply (SMPS) control loop under all operating conditions are crucial for performance evaluation and defect detection. Traditional methods, relyingon experiments under preset conditions, struggle to achieve comprehensive evaluation. This study proposes a frequency characteristic fitting method for all operating conditions based on FT-WOA-MLP. A discrete-point dataset covering all conditions of an LLC SMPS was obtained using the small-signal perturbation method, including input voltage, output current, injection frequency, and corresponding amplitude- and phase-frequency characteristics. The multilayer perceptron (MLP) model was trained on the training set covering all operating conditions, with the whale optimization algorithm (WOA) used to optimize the learning rate, and fine tuning (FT) applied to further enhance accuracy. Independent test set validation showed that, for amplitude-frequency characteristics, the mean absolute error (MAE) was 2.0995, the mean absolute percentage error (MAPE) was 0.0974, the root mean square error (RMSE) was 4.0474, and the coefficient of determination (R2) reached 0.92; for phase-frequency characteristics, the MAE was 3.502, the MAPE was 0.0956, the RMSE was 10.5192, and the R2 reached 0.94. The method accurately fits frequency characteristics under all conditions, supporting defect identification and performance optimization.
- 28 September 2025
- Published by MDPI AG in Journal of Low Power Electronics and Applications
- Vol. 15 (4) , 57
Open AccessResearch on Frequency Characteristic Fitting of LLC Switching-Mode Power Supply Under All Operating Conditions Based on FT-WOA-MLP
The frequency characteristics of the switching-mode power supply (SMPS) control loop under all operating conditions are crucial for performance evaluation and defect detection. Traditional methods, relyingon experiments under preset conditions, struggle to achieve comprehensive evaluation. This study proposes a frequency characteristic fitting method for all operating conditions based on FT-WOA-MLP. A discrete-point dataset covering all conditions of an LLC SMPS was obtained using the small-signal perturbation method, including input voltage, output current, injection frequency, and corresponding amplitude- and phase-frequency characteristics. The multilayer perceptron (MLP) model was trained on the training set covering all operating conditions, with the whale optimization algorithm (WOA) used to optimize the learning rate, and fine tuning (FT) applied to further enhance accuracy. Independent test set validation showed that, for amplitude-frequency characteristics, the mean absolute error (MAE) was 2.0995, the mean absolute percentage error (MAPE) was 0.0974, the root mean square error (RMSE) was 4.0474, and the coefficient of determination (R2) reached 0.92; for phase-frequency characteristics, the MAE was 3.502, the MAPE was 0.0956, the RMSE was 10.5192, and the R2 reached 0.94. The method accurately fits frequency characteristics under all conditions, supporting defect identification and performance optimization.
- Open Access
Modulation and Control Strategy of 3CH4 Combined Current Source Grid-Connected Inverter
In this article, a topology based on the single-phase full-bridge is proposed to decouple control of phase current in current source grid-connected inverters. The DC side of this current source inverter topology can operate with a common DC bus or independently, and the AC side can be independently integrated into the three-phase grid or operate in parallel. This topology needs only a simple control logic and phase information to achieve 3-phase current decoupling control, which can accommodate a wide range of voltage fluctuations. Then, dual-carrier driving and hybrid damping correction strategies are designed to achieve flexible combinatorial operation and eliminate the common-mode voltage. Meanwhile, the method is simple and easy to implement in practice. The effectiveness of the proposed algorithm is validated with experiments.
Open AccessModulation and Control Strategy of 3CH4 Combined Current Source Grid-Connected Inverter
In this article, a topology based on the single-phase full-bridge is proposed to decouple control of phase current in current source grid-connected inverters. The DC side of this current source inverter topology can operate with a common DC bus or independently, and the AC side can be independently integrated into the three-phase grid or operate in parallel. This topology needs only a simple control logic and phase information to achieve 3-phase current decoupling control, which can accommodate a wide range of voltage fluctuations. Then, dual-carrier driving and hybrid damping correction strategies are designed to achieve flexible combinatorial operation and eliminate the common-mode voltage. Meanwhile, the method is simple and easy to implement in practice. The effectiveness of the proposed algorithm is validated with experiments.