AEAhmed ElDegwy

Ahmed ElDegwy

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ahmed ElDegwy has a total of 16 co-authors. Here are the top co-authors by number of shared publications:

  • Ahmed Aboulmagd

    Mechanical Power Engineering Department, Faculty of Engineering, Cairo University, Giza, Egypt

    2 shared publications
  • Abdulmajeed Aldabesh

    Mechanical Engineering Departement, Faculty of Engineering, Al-Baha University, Saudi Arabia

    1 shared publication
  • Ahmed Aboulmagd

    Mechanical Power Department, Faculty of Engineering, Cairo University

    1 shared publication
  • Ahmed Hassan

    Mechanical Power Engineering Department, Faculty of Engineering, Cairo University, Giza, Egypt

    1 shared publication
  • Amr Kaood

    Mechanical Engineering Department, Faculty of Engineering, Fayoum University, El-Fayoum, Egypt

    1 shared publication
  • Ashraf Elsayed

    Department of Mechanical Power Engineering, Faculty of Engineering, Cairo University, Giza, Egypt

    1 shared publication

Latest Publications

  • Open Access

    Computational investigation of smoke management performance in a large enclosed sports using fire dynamics simulator: a comparative assessment of natural and mechanical ventilation strategies

    by Ahmed ElDegwy, Ahmed Hassan, Essam E. Khalil, Mohamed M. A. Hassan

    Smoke management is essential for maintaining tenable conditions during fire emergencies in large enclosed arenas. Although Computational Fluid Dynamics has been widely applied to investigate smoke movement, the combined effects of complex roof geometry, mechanical ventilation capacity, and occupant tenability in sports arenas remain insufficiently explored. This study numerically evaluates smoke management in the Galatsi Olympic Hall using the Fire Dynamics Simulator, with the numerical model validated against published large-scale fire experiments. Four design fire scenarios (5, 10, 15, and 20 MW) were simulated over a 600-s period to compare natural ventilation with mechanical smoke extraction operating between 4 and 10 air changes per hour (ACH). Smoke-layer height, gas temperature, visibility, and carbon monoxide concentration were evaluated against established tenability criteria (NFPA 92B, SFPE Handbook, and NFPA 130). The results show that natural ventilation was unable to maintain tenable conditions under the most severe fire scenario, whereas mechanical smoke extraction significantly improved smoke-control performance. Under the investigated conditions, extraction rates of 8–10 ACH provided the most favorable overall performance among the investigated cases. These findings provide engineering guidance for the performance-based design of smoke management systems in large enclosed sports arenas with similar geometric characteristics. These configuration-specific findings provide engineering guidance for the performance-based design of smoke management systems in large enclosed sports arenas with similar geometric characteristics.

  • Open Access

    CFD Analysis of Geometry and Aerodynamics of Jet Tab Thrust Vector Control (JT-TVC) Utilizing Convergent-Divergent Nozzles

    by Eslam Said Abdelghany, Abdulmajeed Aldabesh, Salman Al-Zahrani, Fares Saeed Saeed Alzaghir Alareqi, Eltayib Tigani Hamed Mohamed, Ahmed ElDegwy

    This study aims to enhance thrust vectoring efficiency by optimizing the geometry of a convergent-divergent (C-D) nozzle integrated with a Jet Tab Thrust Vector Control (JT-TVC) system. JT-TVC improves maneuverability by redirecting exhaust flow through strategically placed obstacles, while reducing system weight and complexity. Using ANSYS-Fluent simulations, the research analyzes parameters such as Mach number, velocity, pressure distribution, and thrust force components (Fy and Fx). Initial validation of numerical models shows the SST k–ω turbulence model provides high accuracy. Comparative analysis of 2D and 3D nozzle models supports the use of 2D configurations for further optimization due to computational efficiency and working time. The second phase explores the effects of obstacle angle (70°, 90°, 110°), shadow area ratio (10%, 20%, 30%), and obstacle-nozzle gap ratio (0%, 1%, 3%, 5%) on thrust vectoring performance. Results show that larger obstacle angles and gap ratios reduce the Fy/Fx ratio, while increasing the shadow area ratio significantly enhances it. The best performance is achieved at a 70° obstacle angle, 30% shadow area ratio, and zero gap ratio, offering improved thrust vectoring for aerospace applications.

  • Open Access

    The Effect of Hidden Radiant Ceiling Cooling Panel (RCCP) on Thermal Comfort and Energy Consumption in Ventilated Office Room with Transparent Ceiling: A CFD Analysis

    by Ahmed ElDegwy

    The present study goal is to observe how the radiant ceiling performs in energy savings and thermal comfort in a ventilated office using CFD simulation. The boundary conditions for each CFD were all described. The profiles of air temperatures, Predicted Mean Vote (PMV), Predicted Percentage of Dissatisfied (PPD), and Draft Risk (DR) were examined to satisfy the comfort criteria of the ASHRAE standard. The effects of varying the temperature of the cooling panel, the air supply temperature, and the presence of air changes per hour (ACH) in the office space on thermal comfort and energy saving were investigated. A mesh is merged using more than 6 million optimized tetrahedral nodes. This investigation was reviewed to ensure that the program was consistent with the experimental results. The current study used the k- ε turbulence model after comparing it to previously published experimental results. Heat transmission by radiation was simulated using the Discrete Ordinates DO radiation model. This study found that the case selection (case 23252) actually has the advantage of energy-saving air conditioning, and its temperature is fixed at 25 °C, which is beneficial because the cooling water used in the cooling plate needs less energy than air in order to cool it (which has a large specific heat capacity and density). In this case, lower quality thermal systems such as geothermal energy or solar energy sources can be used to condition both the water and air supply.

  • INVESTIGATIONS OF THERMAL COMFORT AND AIR FLOW DISTRIBUTION IN NATURALLY VENTILATED LIVING ROOM WITH A CEILING FAN

    by Ahmed El Degwy, Ahmed Aboulmagd

    In this paper, numerical analysis is used to investigate thermal comfort and airflow patterns in ventilated living rooms, including window openings and utilizing a ceiling fan. The air distribution in the living room was accurately predicted in this study using the CFD program. A five-bladed commercial ceiling fan is used to ventilate the room. The major goal of this study is to change the fan speed, fan height, and fan direction of rotation for the purpose of providing the thermal comfort conditions for individuals in the living room. Temperatures, velocities, the PPD index (Predicted Percentage Dissatisfied), and the PMV index (Predicted Mean Vote) distribution have all been taken into consideration while analyzing each case. The results showed that the best thermal comfort values are associated with fan placement in the center of the room at a height of 2.75 m from the floor at a rotational speed of 110 rpm. The overall level of thermal comfort is not significantly different whether downward-drive or upward-drive fans are used, but there is a substantial variation in the local level of thermal comfort in an occupied zone. في هذا البحث ، يتم استخدام التحليل العددي للتحقق من الراحة الحرارية وأنماط تدفق الهواء في غرف المعيشة ذات التهوية بما في ذلك فتحات النوافذ مع استخدام مروحة السقف. تم التنبؤ بدقة بتوزيع الهواء في غرفة المعيشة في هذه الدراسة باستخدام برنامج تحليل عدادى (بإستخدام ديناميكا الموائع الحسابيه). تستخدم مروحة سقف تجارية بخمس شفرات لتهوية الغرفة. الهدف الرئيسي من هذه الدراسة هو تغيير سرعة المروحة وارتفاعها واتجاه دوران المروحة لغرض توفير ظروف الراحة الحرارية للأفراد في غرفة المعيشة. تم أخذ توزيع درجات الحرارة والسرعات ومؤشر (النسبة المئوية المتوقعة غير الراضية) ومؤشر (متوسط التصويت المتوقع) في الاعتبار أثناء تحليل كل حالة. أظهرت النتائج أن أفضل قيم الراحة الحرارية مرتبطة بوضع المروحة في وسط الغرفة على ارتفاع 2.75 متر من الأرضية، بسرعة دوران 110 دورة في الدقيقة. لا يختلف المستوى العام للراحة الحرارية اختلافًا كبيرًا سواء تم...


  • Numerical Investigation of Cooling Tower Performance under Constant Heat Load

    by Ahmed ElDegwy, Ashraf Sayed, Ahmed Aboulmagd

    Cooling towers play a vital role in many large-scale process applications, and any decline in their performance has a considerable effect on the underlying process. It is known that the efficiency of a power plant is greatly affected by the temperature difference of the condenser. The objective of this paper was to produce cooling tower design recommendations and considerations that would prevent negative impacts and ensure stable and efficient operation. Computational fluid dynamics (CFD) was used to examine the components that contribute to cooling tower performance, using steady-state simulations and average weather data from the Egyptian Meteorological Authority. Air flow patterns in and around cooling towers were predicted using computational fluid dynamics. The current study includes a numerical analysis of the performance of the cooling tower at different wind speeds and heights of the cooling tower above the ground. This study found that some wind speeds have a negative effect and others have a positive effect, and the height of the cooling tower above the ground has a positive effect on the performance of the tower.


  • Open Access

    Aerodynamics of ancient egyptian Obelisks and their structural response to Boundary Layer wind

    by Ahmed ElDegwy, Ashraf Elsayed, Mohamed Darwish

    Ancient Egyptian obelisks have been carved thousands of years ago and survived many earthquakes and wind storms. This study examines the aerodynamic characteristics and the response of two of the tallest and slenderest ancient Egyptian obelisks to boundary layer winds using a two-phase methodology. The firstphase involved preparing computational fluid dynamics (CFD) models for the twoobelisks with different angles of projection to wind. The variations in the windpressure coefficient and the forces on the obelisks have been studied for differentprojection angles, different reference velocities and along the height of eachobelisk. Within the second phase structural analysis was performed subjecting eachobelisk to a wind load under different angles of loading. The results show that whensubject to boundary layer winds, the pressure coefficient on the surface and thestresses within the obelisks vary significantly with the angle of attack and dimensions of the obelisk.