Adedoyin Inaolaji
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Adedoyin Inaolaji has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Sumit Paudyal
Department of Electrical and Computer Engineering, Florida International University, Miami, FL, USA
6 shared publications - Alper Savasci
Department of Electrical and Computer Engineering, Florida International University, Miami, FL, USA
5 shared publications - Arif I. Sarwat
Department of Electrical and Computer Engineering, Florida International University, Miami, FL, USA
1 shared publication - Filippo Malandra
Department of Electrical Engineering, University at Buffalo, Buffalo, NY, USA
1 shared publication - Luis Herrera
Department of Electrical Engineering, The State University of New York at Buffalo, Buffalo, NY, USA
1 shared publication - M Al Mamun
Pacific Northwest National Laboratory (PNNL)
1 shared publication
Latest Publications
- 27 June 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 262
Adaptive and fair optimization of smart inverter droop curves in distribution grids
- 27 June 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 262
Adaptive and fair optimization of smart inverter droop curves in distribution grids
- 9 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electrification Magazine
- Vol. 14 (1) , 57-65
Synergies Between Federated Foundation Models and Smart Power Grids: A dual paradigm.
The recent emergence of large language models (LLMs) such as GPT-3 has marked a significant paradigm shift in machine learning. Trained on massive corpora of data, these models demonstrate remarkable capabilities in language understanding, generation, summarization, and reasoning, transforming how intelligent systems process and interact with human language. Although LLMs may still seem like a recent breakthrough, the field is already witnessing the rise of a new and more general category: multimodal, multitask foundation models (M3T FMs). These models go beyond language and can process heterogeneous data types/modalities, such as time-series measurements, audio, imagery, tabular records, and unstructured logs, while supporting a broad range of downstream tasks spanning forecasting, classification, control, and retrieval. When combined with federated learning (FL), they give rise to M3T Federated Foundation Models (FedFMs): a highly recent and largely unexplored class of models that enable scalable, privacy-preserving model training/fine-tuning across distributed data sources. In this paper, we take one of the first steps toward introducing these models to the power systems research community by offering a bidirectional perspective: (i) M3T FedFMs for smart grids and (ii) smart grids for FedFMs. In the former, we explore how M3T FedFMs can enhance key grid functions, such as load/demand forecasting and fault detection, by learning from distributed, heterogeneous data available at the grid edge in a privacy-preserving manner. In the latter, we investigate how the constraints and structure of smart grids, spanning energy, communication, and regulatory dimensions, shape the design, training, and deployment of M3T FedFMs.
- 9 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electrification Magazine
- Vol. 14 (1) , 57-65
Synergies Between Federated Foundation Models and Smart Power Grids: A dual paradigm.
The recent emergence of large language models (LLMs) such as GPT-3 has marked a significant paradigm shift in machine learning. Trained on massive corpora of data, these models demonstrate remarkable capabilities in language understanding, generation, summarization, and reasoning, transforming how intelligent systems process and interact with human language. Although LLMs may still seem like a recent breakthrough, the field is already witnessing the rise of a new and more general category: multimodal, multitask foundation models (M3T FMs). These models go beyond language and can process heterogeneous data types/modalities, such as time-series measurements, audio, imagery, tabular records, and unstructured logs, while supporting a broad range of downstream tasks spanning forecasting, classification, control, and retrieval. When combined with federated learning (FL), they give rise to M3T Federated Foundation Models (FedFMs): a highly recent and largely unexplored class of models that enable scalable, privacy-preserving model training/fine-tuning across distributed data sources. In this paper, we take one of the first steps toward introducing these models to the power systems research community by offering a bidirectional perspective: (i) M3T FedFMs for smart grids and (ii) smart grids for FedFMs. In the former, we explore how M3T FedFMs can enhance key grid functions, such as load/demand forecasting and fault detection, by learning from distributed, heterogeneous data available at the grid edge in a privacy-preserving manner. In the latter, we investigate how the constraints and structure of smart grids, spanning energy, communication, and regulatory dimensions, shape the design, training, and deployment of M3T FedFMs.
- 10 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (3) , 5105-5116
Optimal and Coordinated Control of DERs for Power System Resilience Enhancement under Generation and Load Uncertainties
This paper proposes a multiobjective distribution optimal power flow formulation to improve the resiliency of distribution feeders. The formulated base resiliency strategy prioritizes critical infrastructures (CIs) by ranking them and ensuring their continuous power supply during extreme events through the optimal sizing and placement of hybrid distributed energy resources (DERs). A DER hosting formulation with uncertainty quantification to maximize the capacity integration of the DER is proposed. To ensure effective voltage regulation during extreme events, the DER's smart inverter (SI)'s grid following and grid forming control capabilities are modeled. To capture the probability of subsystem failure during an extreme weather event, this paper proposes a fragility formulation that considers both the windspeed and the age of the components within the grid. Since the load profiles of the CIs will vary during extreme weather events, this paper proposes a weather-adjusted load profile formulation that uses a sigmoid function to model the CI's occupancy behavioral pattern. An extreme event caused by two hurricane categories is simulated on an IEEE 34 distribution feeder using the proposed probabilities of failures. A mixed integer nonlinear programming formulation that aims to maximize the penetration of the DERs, improve the network resiliency, and minimize the overall network losses while satisfying all network and power flow constraints is formulated. The effectiveness of the proposed resiliency enhancement approach is validated via numerical simulations.
- 10 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (3) , 5105-5116
Optimal and Coordinated Control of DERs for Power System Resilience Enhancement under Generation and Load Uncertainties
This paper proposes a multiobjective distribution optimal power flow formulation to improve the resiliency of distribution feeders. The formulated base resiliency strategy prioritizes critical infrastructures (CIs) by ranking them and ensuring their continuous power supply during extreme events through the optimal sizing and placement of hybrid distributed energy resources (DERs). A DER hosting formulation with uncertainty quantification to maximize the capacity integration of the DER is proposed. To ensure effective voltage regulation during extreme events, the DER's smart inverter (SI)'s grid following and grid forming control capabilities are modeled. To capture the probability of subsystem failure during an extreme weather event, this paper proposes a fragility formulation that considers both the windspeed and the age of the components within the grid. Since the load profiles of the CIs will vary during extreme weather events, this paper proposes a weather-adjusted load profile formulation that uses a sigmoid function to model the CI's occupancy behavioral pattern. An extreme event caused by two hurricane categories is simulated on an IEEE 34 distribution feeder using the proposed probabilities of failures. A mixed integer nonlinear programming formulation that aims to maximize the penetration of the DERs, improve the network resiliency, and minimize the overall network losses while satisfying all network and power flow constraints is formulated. The effectiveness of the proposed resiliency enhancement approach is validated via numerical simulations.
- 12 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (2) , 2288-2299
Computationally Efficient Dynamic Simulation of Unbalanced Distribution Systems with PV Inverters
Distribution systems (DSs) are experiencing growing integration of Photovoltaic (PV) inverters to meet the increased load demands. PV inverters can create significant dynamics on DS and it is crucial to determine the system dynamics on all three phases as the DSs are unbalanced in nature. Current approaches for solving the dynamics of PV-integrated DSs are reliant on off-the-shelf solvers which are computationally inefficient, making them unsuitable for real-time applications. In this context, this paper presents a numerical approach for efficiently solving the dynamics of unbalanced DSs with PV inverters operating in Volt-VAr or Volt-Watt modes. The solve time of such simulations largely depends on the underlying network power flow model and the algorithm. As nonlinear solvers are iterative and computationally expensive, this work adopts a linear distribution three-phase power flow (LinDist3Flow) model to speed up the computation of dynamic analyses. Case studies are conducted on a European low-voltage feeder with five PV inverters and a 2520-node feeder with 558 PV inverters. The proposed method accurately captures the dynamics of network voltage as well as the active and reactive power of PV inverters, with minimal root mean square errors. Notably, the results show that the proposed linear approach is over twice as fast as nonlinear power flow-based dynamic models, offering a computationally efficient solution for analyzing the dynamics of unbalanced DSs.
- 12 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (2) , 2288-2299
Computationally Efficient Dynamic Simulation of Unbalanced Distribution Systems with PV Inverters
Distribution systems (DSs) are experiencing growing integration of Photovoltaic (PV) inverters to meet the increased load demands. PV inverters can create significant dynamics on DS and it is crucial to determine the system dynamics on all three phases as the DSs are unbalanced in nature. Current approaches for solving the dynamics of PV-integrated DSs are reliant on off-the-shelf solvers which are computationally inefficient, making them unsuitable for real-time applications. In this context, this paper presents a numerical approach for efficiently solving the dynamics of unbalanced DSs with PV inverters operating in Volt-VAr or Volt-Watt modes. The solve time of such simulations largely depends on the underlying network power flow model and the algorithm. As nonlinear solvers are iterative and computationally expensive, this work adopts a linear distribution three-phase power flow (LinDist3Flow) model to speed up the computation of dynamic analyses. Case studies are conducted on a European low-voltage feeder with five PV inverters and a 2520-node feeder with 558 PV inverters. The proposed method accurately captures the dynamics of network voltage as well as the active and reactive power of PV inverters, with minimal root mean square errors. Notably, the results show that the proposed linear approach is over twice as fast as nonlinear power flow-based dynamic models, offering a computationally efficient solution for analyzing the dynamics of unbalanced DSs.
- 8 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (1) , 1322-1331
Optimal Tuning of Local Voltage Control Rule of Load Tap Changers for Dynamic Operation of Unbalanced Distribution Networks
A bang-bang type control rule is typically adopted to automate the tap-changing process of on-load tap changers (OLTCs) and step voltage regulators (SVRs). The control rule is mainly characterized by a dead band parameter affecting voltage regulation performance. Due to the intermittent large-scale photovoltaic (PV) penetration, dynamic voltage fluctuations are induced along the distribution feeder, leading to frequent tap switching and equipment wear and tear. This paper proposes an optimization-based dead band tuning method to reduce the number of tap switching and lengthen the economic use-life of the regulation equipment. Unlike existing works that often ignore the local controller mechanism of tap changers, this work extends the modeling efforts by formulating the dead band tuning as a distribution system optimal power flow (DOPF) problem by considering the unbalanced characteristics of multi-phase feeders. The overall DOPF is formulated as a mixed- integer linear program (MILP) to minimize the daily total number of tap switching and the amount of curtailed energy from the PV-based inverters while maintaining voltage regulation performance. Extensive numerical tests conducted on the IEEE 13- bus and IEEE 123- bus test networks suggest that the number of tap switching can further be minimized with the use of a dynamic dead band tuning strategy.
- 8 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (1) , 1322-1331
Optimal Tuning of Local Voltage Control Rule of Load Tap Changers for Dynamic Operation of Unbalanced Distribution Networks
A bang-bang type control rule is typically adopted to automate the tap-changing process of on-load tap changers (OLTCs) and step voltage regulators (SVRs). The control rule is mainly characterized by a dead band parameter affecting voltage regulation performance. Due to the intermittent large-scale photovoltaic (PV) penetration, dynamic voltage fluctuations are induced along the distribution feeder, leading to frequent tap switching and equipment wear and tear. This paper proposes an optimization-based dead band tuning method to reduce the number of tap switching and lengthen the economic use-life of the regulation equipment. Unlike existing works that often ignore the local controller mechanism of tap changers, this work extends the modeling efforts by formulating the dead band tuning as a distribution system optimal power flow (DOPF) problem by considering the unbalanced characteristics of multi-phase feeders. The overall DOPF is formulated as a mixed- integer linear program (MILP) to minimize the daily total number of tap switching and the amount of curtailed energy from the PV-based inverters while maintaining voltage regulation performance. Extensive numerical tests conducted on the IEEE 13- bus and IEEE 123- bus test networks suggest that the number of tap switching can further be minimized with the use of a dynamic dead band tuning strategy.
- 5 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (5) , 5385-5397
Distributed Optimal Power Flow in Unbalanced Distribution Grids With Non-Ideal Communication
The use of distributed optimization for solving optimal power flow (OPF) problems in distribution networks is increasing as the number of controllable devices and the span of service areas increase. However, the performance of the distributed optimization algorithm largely depends on the availability and quality of communication links between the computing entities. In this paper, we evaluate the performance of the alternating direction method of multipliers (ADMM) for solving the OPF problem for volt-VAr optimization (VVO) under non-ideal communication. The overall problem is formulated by considering the unbalanced operation of multi-phase distribution networks. The algorithm's performance is first analyzed, assuming there is an ideal communication between computing entities, which serves as a benchmark for further analysis. Then, two non-ideal communication models, namely (1) sporadic communication failure and (2) communication under a noisy transmission, are applied to the information exchange architecture of the ADMM. Extensive numerical experiments are conducted with two test systems, the IEEE 123-bus feeder and a 2522-bus network scaled down from the IEEE 8500-bus system; these are used to evaluate the performance of the algorithm. The results indicate that the ADMM-based distributed VVO algorithm has deteriorated performance under high levels of communication failure and high levels of noise injection. Additionally, although the centralized-VVO counterpart has some computational superiority when the overall problem is convex and no communication impairments exist, the distributed-VVO has superior immunized solution performance under realistic communication constraints.
- 5 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (5) , 5385-5397
Distributed Optimal Power Flow in Unbalanced Distribution Grids With Non-Ideal Communication
The use of distributed optimization for solving optimal power flow (OPF) problems in distribution networks is increasing as the number of controllable devices and the span of service areas increase. However, the performance of the distributed optimization algorithm largely depends on the availability and quality of communication links between the computing entities. In this paper, we evaluate the performance of the alternating direction method of multipliers (ADMM) for solving the OPF problem for volt-VAr optimization (VVO) under non-ideal communication. The overall problem is formulated by considering the unbalanced operation of multi-phase distribution networks. The algorithm's performance is first analyzed, assuming there is an ideal communication between computing entities, which serves as a benchmark for further analysis. Then, two non-ideal communication models, namely (1) sporadic communication failure and (2) communication under a noisy transmission, are applied to the information exchange architecture of the ADMM. Extensive numerical experiments are conducted with two test systems, the IEEE 123-bus feeder and a 2522-bus network scaled down from the IEEE 8500-bus system; these are used to evaluate the performance of the algorithm. The results indicate that the ADMM-based distributed VVO algorithm has deteriorated performance under high levels of communication failure and high levels of noise injection. Additionally, although the centralized-VVO counterpart has some computational superiority when the overall problem is convex and no communication impairments exist, the distributed-VVO has superior immunized solution performance under realistic communication constraints.
- 15 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 58 (5) , 5711-5723
Two-Stage Volt-VAr Optimization of Distribution Grids With Smart Inverters and Legacy Devices
This article develops a two-stage volt-VAr control strategy coordinating the discrete controls of legacy grid devices and the operation of smart inverters (SIs) in power distribution grids with high penetration of photovoltaic generation. The first stage dispatch problem optimally coordinates the tap settings of on-load tap changers, on / off status of shunt capacitor banks, and SIs’ active power output. The second stage incorporates the SI volt-VAr mode, i.e., $\mathbf{Q(V)}$ as per IEEE-1547, and an adaptive volt-VAr droop function, $\mathbf{Q(\Delta V)}$ , to dispatch the SI reactive power generation. Both dispatch problems are formulated as mixed-integer linear programming problems to maintain tractable formulations and reduce the complexity and computational burden that usually arise when solving large-scale optimal power flow problems. The proposed two-stage strategy is tested on a modified IEEE 123-bus system considering different droop settings. The dispatch strategy augmented with $\mathbf{Q(\Delta V)}$ droop outperforms the model with only $\mathbf{Q(V)}$ droop in stabilizing the PCC voltage while maintaining less active power curtailment.
- 15 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 58 (5) , 5711-5723
Two-Stage Volt-VAr Optimization of Distribution Grids With Smart Inverters and Legacy Devices
This article develops a two-stage volt-VAr control strategy coordinating the discrete controls of legacy grid devices and the operation of smart inverters (SIs) in power distribution grids with high penetration of photovoltaic generation. The first stage dispatch problem optimally coordinates the tap settings of on-load tap changers, on / off status of shunt capacitor banks, and SIs’ active power output. The second stage incorporates the SI volt-VAr mode, i.e., $\mathbf{Q(V)}$ as per IEEE-1547, and an adaptive volt-VAr droop function, $\mathbf{Q(\Delta V)}$ , to dispatch the SI reactive power generation. Both dispatch problems are formulated as mixed-integer linear programming problems to maintain tractable formulations and reduce the complexity and computational burden that usually arise when solving large-scale optimal power flow problems. The proposed two-stage strategy is tested on a modified IEEE 123-bus system considering different droop settings. The dispatch strategy augmented with $\mathbf{Q(\Delta V)}$ droop outperforms the model with only $\mathbf{Q(V)}$ droop in stabilizing the PCC voltage while maintaining less active power curtailment.
- 9 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 58 (5) , 5832-5843
Distribution Grid Optimal Power Flow in Unbalanced Multiphase Networks With Volt-VAr and Volt-Watt Droop Settings of Smart Inverters
High penetration of photovoltaic (PV) generators in active distribution networks (ADNs) cause overvoltage due to reverse power flow. Smart inverter (SI) functionalities can be configured to provide efficient voltage regulation and reactive power support in ADNs. Moreover, the mismatch between peak PV generation and peak demand make battery energy storage systems (BESSs) increasingly important assets in power grids, capable of enabling higher penetration of renewable energy resources by mitigating the system-wide effects of PV intermittency. In this work, we propose the inclusion of local piecewise Volt-VAr and Volt-Watt droop functions of PV (as per the IEEE-1547) as constraints in a multiperiod distribution grid optimal power flow (DOPF) formulation. This approach is an efficient voltage control method for unbalanced multiphase networks, making the inverter dispatch solutions abide by the IEEE-1547 standard and therefore suitable at the local inverter controller level. We adopt a well-known LinDist3Flow version of DOPF, and the resulting multiperiod DOPF becomes a mixed-integer linear programming problem. Simulations on the IEEE 123-node feeder with 15 utility-scale PV and BESS inverters validate the efficacy of the proposed formulation in performing effective voltage regulation and control that abide by the IEEE-1547 standard. The case studies show that SI droop-integrated DOPF can ensure reduced variation in bus voltages, reducing the risk of voltage violations, and net load smoothing can be achieved with BESS, reducing the disparity between inexpensive midday and expensive evening energy price.
- 9 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 58 (5) , 5832-5843
Distribution Grid Optimal Power Flow in Unbalanced Multiphase Networks With Volt-VAr and Volt-Watt Droop Settings of Smart Inverters
High penetration of photovoltaic (PV) generators in active distribution networks (ADNs) cause overvoltage due to reverse power flow. Smart inverter (SI) functionalities can be configured to provide efficient voltage regulation and reactive power support in ADNs. Moreover, the mismatch between peak PV generation and peak demand make battery energy storage systems (BESSs) increasingly important assets in power grids, capable of enabling higher penetration of renewable energy resources by mitigating the system-wide effects of PV intermittency. In this work, we propose the inclusion of local piecewise Volt-VAr and Volt-Watt droop functions of PV (as per the IEEE-1547) as constraints in a multiperiod distribution grid optimal power flow (DOPF) formulation. This approach is an efficient voltage control method for unbalanced multiphase networks, making the inverter dispatch solutions abide by the IEEE-1547 standard and therefore suitable at the local inverter controller level. We adopt a well-known LinDist3Flow version of DOPF, and the resulting multiperiod DOPF becomes a mixed-integer linear programming problem. Simulations on the IEEE 123-node feeder with 15 utility-scale PV and BESS inverters validate the efficacy of the proposed formulation in performing effective voltage regulation and control that abide by the IEEE-1547 standard. The case studies show that SI droop-integrated DOPF can ensure reduced variation in bus voltages, reducing the risk of voltage violations, and net load smoothing can be achieved with BESS, reducing the disparity between inexpensive midday and expensive evening energy price.
- 2 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Performance Analysis of Mixed-Integer Conic and Mixed-Integer Linear Unit Commitment Models
Computational tractability and scalability are general concerns of Unit Commitment (UC) formulations given the inherent non-convex nature of the problem. Mixed-integer linear programming (MILP) version of UC is very common in modern Energy Management Systems. Lately, mixed-integer second order cone programming (MISOCP) versions of UC are also gaining research attention. To this end, this paper presents a comparative analysis of MILP and MISOCP based UC formulations with and without network constraints. Extensive numerical simulations are performed to investigate accuracy and scalability of MISOCP and MILP UC formulations with several test cases up to 1,000 generating units. Results show that the MISOCP UC model is generally superior to its MILP counterpart in terms of costs. On the computational time, MISOCP performed superior compared to MILP for large power systems. However, for small systems, MILP UC model performed very similar to MISOCP version in terms of the computational time.
- 2 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Performance Analysis of Mixed-Integer Conic and Mixed-Integer Linear Unit Commitment Models
Computational tractability and scalability are general concerns of Unit Commitment (UC) formulations given the inherent non-convex nature of the problem. Mixed-integer linear programming (MILP) version of UC is very common in modern Energy Management Systems. Lately, mixed-integer second order cone programming (MISOCP) versions of UC are also gaining research attention. To this end, this paper presents a comparative analysis of MILP and MISOCP based UC formulations with and without network constraints. Extensive numerical simulations are performed to investigate accuracy and scalability of MISOCP and MILP UC formulations with several test cases up to 1,000 generating units. Results show that the MISOCP UC model is generally superior to its MILP counterpart in terms of costs. On the computational time, MISOCP performed superior compared to MILP for large power systems. However, for small systems, MILP UC model performed very similar to MISOCP version in terms of the computational time.