Yinli Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yinli Chen has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Daiki Sato
Institute of Integrated Research (IIR), Institute of Science Tokyo
13 shared publications - Jinhua She
Tokyo University of Technology
11 shared publications - Kou Miyamoto
Institute of Technology, Shimizu Corporation, Koto, Tokyo 135-0044, Japan
11 shared publications Daiki Sato
3 shared publications- Razelle Dennise A. Soriano
Institute of Science Tokyo
2 shared publications - Ryuki Kamano
Institute of Science Tokyo,Kanagawa,Japan,226-8501
2 shared publications
Latest Publications
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/CAA Journal of Automatica Sinica
- Vol. 13 (10) , 2426-2428
A Feedback-Linearization-Based Active Structural Control Strategy for Buildings with Nonlinear Dampers
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/CAA Journal of Automatica Sinica
- Vol. 13 (10) , 2426-2428
A Feedback-Linearization-Based Active Structural Control Strategy for Buildings with Nonlinear Dampers
- 1 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/CAA Journal of Automatica Sinica
- Vol. 13 (5) , 1236-1238
Peak Factor Method for Predicting Maximum Response and Control Force in Across-Wind Direction for Active Base-Isolation
Dear Editor, This letter proposes a simple method for estimating the maximum responses and control forces of base-isolated structures with active structural control (active base-isolation) without numerical simulations. An equivalent passive system of an active base-isolation is constructed to obtain the first mode's input and modal transfer function. Based on these parameters, a simple method for estimating the standard deviations of the responses and control forces in active base-isolation is developed.
- 1 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/CAA Journal of Automatica Sinica
- Vol. 13 (5) , 1236-1238
Peak Factor Method for Predicting Maximum Response and Control Force in Across-Wind Direction for Active Base-Isolation
Dear Editor, This letter proposes a simple method for estimating the maximum responses and control forces of base-isolated structures with active structural control (active base-isolation) without numerical simulations. An equivalent passive system of an active base-isolation is constructed to obtain the first mode's input and modal transfer function. Based on these parameters, a simple method for estimating the standard deviations of the responses and control forces in active base-isolation is developed.
- Open Access
- 27 May 2026
- Published by Elsevier in Engineering Structures
- Vol. 363
Evaluation of time-varying dynamic properties of base-isolated high-rise building during lateral extension using monitored data
- 27 May 2026
- Published by Elsevier in Engineering Structures
- Vol. 363
Open AccessEvaluation of time-varying dynamic properties of base-isolated high-rise building during lateral extension using monitored data
- Open Access
- 20 December 2025
- Published by Elsevier in Journal of Sound and Vibration
- Vol. 626
A response-spectra-based design method for LQR control of active base-isolated buildings with bilinear oil dampers
- 20 December 2025
- Published by Elsevier in Journal of Sound and Vibration
- Vol. 626
Open AccessA response-spectra-based design method for LQR control of active base-isolated buildings with bilinear oil dampers
- 28 March 2025
- Published by SAGE Publications in Journal of Vibration and Control
- Vol. 32 (9-10) , 2242-2251
Wind force estimation on a nonlinear seismic-isolated building by equivalent-input-disturbance method
Seismic isolation is highly effective in safeguarding tall buildings against earthquake-induced forces. However, these structures remain vulnerable to strong winds that can induce nonlinear responses in the isolation layers. Accurate estimation of wind force time-histories is crucial for the analysis and design of such seismically isolated buildings, yet existing methods either inadequately capture environmental conditions or fail to consider structural nonlinearities. This study introduces the Equivalent-Input-Disturbance Method for Nonlinear Systems (EID-NS) to estimate wind force time-histories for a nonlinear mid-story isolated building based on wind-induced velocity responses. Comparative analysis with the standard EID approach demonstrates that EID-NS offers better accuracy in addressing nonlinear behaviors. The results confirm that EID-NS effectively captures wind forces acting on nonlinear isolated structures, providing a robust and reliable method for wind force estimation in complex structural systems.
- 28 March 2025
- Published by SAGE Publications in Journal of Vibration and Control
- Vol. 32 (9-10) , 2242-2251
Wind force estimation on a nonlinear seismic-isolated building by equivalent-input-disturbance method
Seismic isolation is highly effective in safeguarding tall buildings against earthquake-induced forces. However, these structures remain vulnerable to strong winds that can induce nonlinear responses in the isolation layers. Accurate estimation of wind force time-histories is crucial for the analysis and design of such seismically isolated buildings, yet existing methods either inadequately capture environmental conditions or fail to consider structural nonlinearities. This study introduces the Equivalent-Input-Disturbance Method for Nonlinear Systems (EID-NS) to estimate wind force time-histories for a nonlinear mid-story isolated building based on wind-induced velocity responses. Comparative analysis with the standard EID approach demonstrates that EID-NS offers better accuracy in addressing nonlinear behaviors. The results confirm that EID-NS effectively captures wind forces acting on nonlinear isolated structures, providing a robust and reliable method for wind force estimation in complex structural systems.
- Open Access
- 30 November 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 98
Response-spectrum-based design method for gain-scheduling control of active base-isolated structures with nonlinear viscous dampers
- 30 November 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 98
Open AccessResponse-spectrum-based design method for gain-scheduling control of active base-isolated structures with nonlinear viscous dampers
- 25 January 2024
- Published by Elsevier in Control Engineering Practice
- Vol. 145
Wind-load estimation for seismically isolated building by equivalent-input-disturbance approach with robust-control strategy
- 25 January 2024
- Published by Elsevier in Control Engineering Practice
- Vol. 145
Wind-load estimation for seismically isolated building by equivalent-input-disturbance approach with robust-control strategy
- Open Access
- 1 January 2024
- Published by Wiley in Structural Control and Health Monitoring
- Vol. 2024 (1)
Gust Factor Approach for Estimating Maximum Response and Control Force in High‐Rise Base‐Isolated Buildings with Active Structural Control
This paper devises a new method for estimating the maximum response and maximum control force for high‐rise base‐isolated buildings with active structural control (active base isolation) to simplify the conventional complex design procedure. While active base isolation has emerged as a prominent solution for achieving high control performance, its design process is inherently complex, particularly when applied to high‐rise buildings where wind loads become prominent. To address this problem, we propose a streamlined method inspired by the gust factor methodology widely used in conventional passive wind‐resistant designs. This method estimates the maximum response and maximum control force without the need for numerical simulations. We first construct an equivalent passive model of a multi‐degree‐of‐freedom control system to theoretically compute the dynamics of the system. Based on the constructed equivalent passive model and then propose a method to calculate the mean displacement and mean control force using only the static equilibrium of this model. Furthermore, we extend the conventional gust factor approach to active base isolation to estimate the maximum displacement and maximum control force for active base isolation without the need for numerical simulations. We validate our methods through a series of numerical examples, incorporating key parameters such as feedback gain, aspect ratio of building, return period of wind force, and stiffness of isolation. Numerical verifications show that the mean response and mean control force are estimated by the static equilibrium of the proposed equivalent passive model. Moreover, the maximum response and maximum control force can be estimated by the proposed gust factors. Our methods can be applied for feedback control systems using a given feedback gain.
- 1 January 2024
- Published by Wiley in Structural Control and Health Monitoring
- Vol. 2024 (1)
Open AccessGust Factor Approach for Estimating Maximum Response and Control Force in High‐Rise Base‐Isolated Buildings with Active Structural Control
This paper devises a new method for estimating the maximum response and maximum control force for high‐rise base‐isolated buildings with active structural control (active base isolation) to simplify the conventional complex design procedure. While active base isolation has emerged as a prominent solution for achieving high control performance, its design process is inherently complex, particularly when applied to high‐rise buildings where wind loads become prominent. To address this problem, we propose a streamlined method inspired by the gust factor methodology widely used in conventional passive wind‐resistant designs. This method estimates the maximum response and maximum control force without the need for numerical simulations. We first construct an equivalent passive model of a multi‐degree‐of‐freedom control system to theoretically compute the dynamics of the system. Based on the constructed equivalent passive model and then propose a method to calculate the mean displacement and mean control force using only the static equilibrium of this model. Furthermore, we extend the conventional gust factor approach to active base isolation to estimate the maximum displacement and maximum control force for active base isolation without the need for numerical simulations. We validate our methods through a series of numerical examples, incorporating key parameters such as feedback gain, aspect ratio of building, return period of wind force, and stiffness of isolation. Numerical verifications show that the mean response and mean control force are estimated by the static equilibrium of the proposed equivalent passive model. Moreover, the maximum response and maximum control force can be estimated by the proposed gust factors. Our methods can be applied for feedback control systems using a given feedback gain.
- Open Access
Effects of Different Frequency Sensitivity Models of a Viscoelastic Damper on Wind-Induced Response of High-Rise Buildings
The fractional derivative (FD) model is one kind of numerical model of viscoelastic (VE) damper, which can describe the behavior of the frequency sensitivity of VE damper well with some empirical parameters. However, the FD model is difficult to apply to practice design because of its complex calculation. Compared with the FD model, the integer derivative (ID) models are widely used as the VE damper equipped in the high-rise building. However, ID models lack consideration of frequency sensitivity, which significantly affects their accuracy. To consider frequency sensitivity in the ID model, this study attempted to use the 4-element and 6-element models of ID models to approximate the FD model, easily describing the VE characteristic of the damper. The wind forces of 500-year-return periods were employed to analyze the influence of the frequency sensitivity of the VE damper on wind-induced responses and energy dissipation. The results of this study showed that the 4-element and 6-element models not only matched frequency sensitivities well to the FD model in the low-frequency region of wind excitation but also had good agreements with the FD model in wind-induced responses and energy dissipation. Based on the findings in this study, the 4-element and 6-element models were recommended as numerical models for the wind-resistant design of high-rise buildings with VE dampers. It helps improve the wind-induced behavior simulation of VE dampers considering their frequency sensitivity in high accuracy without massive experimental cost.
Open AccessEffects of Different Frequency Sensitivity Models of a Viscoelastic Damper on Wind-Induced Response of High-Rise Buildings
The fractional derivative (FD) model is one kind of numerical model of viscoelastic (VE) damper, which can describe the behavior of the frequency sensitivity of VE damper well with some empirical parameters. However, the FD model is difficult to apply to practice design because of its complex calculation. Compared with the FD model, the integer derivative (ID) models are widely used as the VE damper equipped in the high-rise building. However, ID models lack consideration of frequency sensitivity, which significantly affects their accuracy. To consider frequency sensitivity in the ID model, this study attempted to use the 4-element and 6-element models of ID models to approximate the FD model, easily describing the VE characteristic of the damper. The wind forces of 500-year-return periods were employed to analyze the influence of the frequency sensitivity of the VE damper on wind-induced responses and energy dissipation. The results of this study showed that the 4-element and 6-element models not only matched frequency sensitivities well to the FD model in the low-frequency region of wind excitation but also had good agreements with the FD model in wind-induced responses and energy dissipation. Based on the findings in this study, the 4-element and 6-element models were recommended as numerical models for the wind-resistant design of high-rise buildings with VE dampers. It helps improve the wind-induced behavior simulation of VE dampers considering their frequency sensitivity in high accuracy without massive experimental cost.