Brennan Flannery
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Brennan Flannery has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Amir Reza Sadri
Case Western Reserve University, Department of Biomedical Engineering, 10900 Euclid Ave, Cleveland, OH 44106, USA
1 shared publication Amit Shah
WellSpan Health York PA USA
1 shared publication- Anant Madabhushi
Department of Biomedical Engineering, Emory University, Atlanta, USA
1 shared publication Brian T. Golz
Purdue University, Weldon School of Biomedical Engineering
1 shared publication- Christopher J. Weight
Glickman Urological and Kidney Institute, Section of Urologic Oncology
1 shared publication Felix Feng
University of California San Francisco San Francisco CA USA
1 shared publication
Latest Publications
- Open Access
- 9 March 2026
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 206, 111603
Empirical evaluation of variability and multi-institutional generalizability of deep learning survival models: application to renal cancer CT scans
- 9 March 2026
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 206, 111603
Open AccessEmpirical evaluation of variability and multi-institutional generalizability of deep learning survival models: application to renal cancer CT scans
- 1 March 2026
- Published by Radiological Society of North America (RSNA) in Radiology: Imaging Cancer
- Vol. 8 (2) , e260002
AI Do’s and Don’ts in Cancer Imaging: Remembering the Patient Behind the Pixel
- 1 March 2026
- Published by Radiological Society of North America (RSNA) in Radiology: Imaging Cancer
- Vol. 8 (2) , e260002
AI Do’s and Don’ts in Cancer Imaging: Remembering the Patient Behind the Pixel
- Open Access
- 11 December 2024
- Published by Wiley in The Journal of Pathology
- Vol. 265 (2) , 146-157
Stress testing deep learning models for prostate cancer detection on biopsies and surgical specimens
The presence, location, and extent of prostate cancer is assessed by pathologists using H&E‐stained tissue slides. Machine learning approaches can accomplish these tasks for both biopsies and radical prostatectomies. Deep learning approaches using convolutional neural networks (CNNs) have been shown to identify cancer in pathologic slides, some securing regulatory approval for clinical use. However, differences in sample processing can subtly alter the morphology between sample types, making it unclear whether deep learning algorithms will consistently work on both types of slide images. Our goal was to investigate whether morphological differences between sample types affected the performance of biopsy‐trained cancer detection CNN models when applied to radical prostatectomies and vice versa using multiple cohorts ( N = 1,000). Radical prostatectomies ( N = 100) and biopsies ( N = 50) were acquired from The University of Pennsylvania to train (80%) and validate (20%) a DenseNet CNN for biopsies (M B ), radical prostatectomies (M R ), and a combined dataset (M B+R ). On a tile level, M B and M R achieved F1 scores greater than 0.88 when applied to their own sample type but less than 0.65 when applied across sample types. On a whole‐slide level, models achieved significantly better performance on their own sample type compared to the alternative model ( p < 0.05) for all metrics. This was confirmed by external validation using digitized biopsy slide images from a clinical trial [NRG Radiation Therapy Oncology Group (RTOG)] (NRG/RTOG 0521, N = 750) via both qualitative and quantitative analyses ( p < 0.05). A comprehensive review of model outputs revealed morphologically driven decision making that adversely affected model performance. M B appeared to be challenged with the analysis of open gland structures, whereas M R appeared to be challenged with closed gland structures, indicating potential morphological variation between the training sets. These findings suggest that differences in morphology and heterogeneity necessitate the need for more tailored, sample‐specific (i.e. biopsy and surgical) machine learning models. © 2024 The Author(s). The Journal of Pathology published by John Wiley & Sons Ltd on behalf of The Pathological Society of Great Britain and Ireland.
- 11 December 2024
- Published by Wiley in The Journal of Pathology
- Vol. 265 (2) , 146-157
Open AccessStress testing deep learning models for prostate cancer detection on biopsies and surgical specimens
The presence, location, and extent of prostate cancer is assessed by pathologists using H&E‐stained tissue slides. Machine learning approaches can accomplish these tasks for both biopsies and radical prostatectomies. Deep learning approaches using convolutional neural networks (CNNs) have been shown to identify cancer in pathologic slides, some securing regulatory approval for clinical use. However, differences in sample processing can subtly alter the morphology between sample types, making it unclear whether deep learning algorithms will consistently work on both types of slide images. Our goal was to investigate whether morphological differences between sample types affected the performance of biopsy‐trained cancer detection CNN models when applied to radical prostatectomies and vice versa using multiple cohorts ( N = 1,000). Radical prostatectomies ( N = 100) and biopsies ( N = 50) were acquired from The University of Pennsylvania to train (80%) and validate (20%) a DenseNet CNN for biopsies (M B ), radical prostatectomies (M R ), and a combined dataset (M B+R ). On a tile level, M B and M R achieved F1 scores greater than 0.88 when applied to their own sample type but less than 0.65 when applied across sample types. On a whole‐slide level, models achieved significantly better performance on their own sample type compared to the alternative model ( p < 0.05) for all metrics. This was confirmed by external validation using digitized biopsy slide images from a clinical trial [NRG Radiation Therapy Oncology Group (RTOG)] (NRG/RTOG 0521, N = 750) via both qualitative and quantitative analyses ( p < 0.05). A comprehensive review of model outputs revealed morphologically driven decision making that adversely affected model performance. M B appeared to be challenged with the analysis of open gland structures, whereas M R appeared to be challenged with closed gland structures, indicating potential morphological variation between the training sets. These findings suggest that differences in morphology and heterogeneity necessitate the need for more tailored, sample‐specific (i.e. biopsy and surgical) machine learning models. © 2024 The Author(s). The Journal of Pathology published by John Wiley & Sons Ltd on behalf of The Pathological Society of Great Britain and Ireland.
- 7 June 2022
- Published by Optica Publishing Group in Optics Continuum
- Vol. 1 (6) , 1364-1374
Automated bone cell classification for confocal laser scanning microscopy volumes
Manual cell classification in microscopy images is a time-consuming process that heavily relies on the subjective perception of the investigator. Identifying bone cells introduces additional difficulties with irregular geometries, and in some culture conditions, the presence of bone mineral. As fluorescence-based lineage tracing becomes more common, classifying cell types based upon cell color can further increase subjectivity. Our goal is to develop and validate a fully automated cell classification algorithm that can (i) objectively identify cells in flattened volumetric image stacks from three-dimensional (3D) bone cell cultures and (ii) classify the cells (osteoblast-lineage) based on the color of their cell bodies. The algorithm used here was developed in MATLAB 2019a and validated by comparing code outputs to manual labeling for eleven images. The precision, recall, and F1 scores were higher than 0.75 for all cell classifications, with the majority being greater than 0.80. No significant differences were found between the manually labelled and automated cell counts or cell classifications. Analysis time for a single image averaged seventeen seconds compared to more than ten minutes for manual labeling. This demonstrates that the program offers a fast, repeatable, and accurate way to classify bone cells by fluorescence in confocal microscopy image data sets. This process can be expanded to improve investigation of other pre-clinical models and histological sections of pathological tissues where color or fluorescence-based differences are used for cell identification.
- 7 June 2022
- Published by Optica Publishing Group in Optics Continuum
- Vol. 1 (6) , 1364-1374
Automated bone cell classification for confocal laser scanning microscopy volumes
Manual cell classification in microscopy images is a time-consuming process that heavily relies on the subjective perception of the investigator. Identifying bone cells introduces additional difficulties with irregular geometries, and in some culture conditions, the presence of bone mineral. As fluorescence-based lineage tracing becomes more common, classifying cell types based upon cell color can further increase subjectivity. Our goal is to develop and validate a fully automated cell classification algorithm that can (i) objectively identify cells in flattened volumetric image stacks from three-dimensional (3D) bone cell cultures and (ii) classify the cells (osteoblast-lineage) based on the color of their cell bodies. The algorithm used here was developed in MATLAB 2019a and validated by comparing code outputs to manual labeling for eleven images. The precision, recall, and F1 scores were higher than 0.75 for all cell classifications, with the majority being greater than 0.80. No significant differences were found between the manually labelled and automated cell counts or cell classifications. Analysis time for a single image averaged seventeen seconds compared to more than ten minutes for manual labeling. This demonstrates that the program offers a fast, repeatable, and accurate way to classify bone cells by fluorescence in confocal microscopy image data sets. This process can be expanded to improve investigation of other pre-clinical models and histological sections of pathological tissues where color or fluorescence-based differences are used for cell identification.