Suyu Liao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Suyu Liao has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Yining Zhu
School of Mathematical Sciences, Capital Normal University, Beijing, China
2 shared publications - Grace Jianan Gang
Department of Radiology, University of Pennsylvania, Philadelphia, PA, U.S.A.
1 shared publication - Huitao Zhang
School of Mathematical Sciences, Capital Normal University, Beijing, China
1 shared publication - Joseph Webster Stayman
Johns Hopkins University
1 shared publication - Junjie Peng
School of Mathematical Sciences, Capital Normal University, Beijing, China
1 shared publication Kai Zhang
Institute of High Energy Physics, Chinese Academy of Sciences, China
1 shared publication
Latest Publications
- 16 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (12) , 3501-3514
Joint Temporal and Spectral Processing for Improved Digital Subtraction Angiography Using Photon-Counting Detectors
Objective: Digital subtraction angiography (DSA) is the gold standard modality for diagnostics and guidance for interventional procedures. Spectral imaging has previously been explored for DSA, but severe noise amplification from material decomposition has impeded clinical adoption. We present a novel joint processing strategy that leverages both temporal and spectral information for material decomposition to address this issue. Methods: We develop a model-based material decomposition approach that utilizes the pre- and post-contrast images simultaneously for material estimation. Performance was evaluated on a small-vessel phantom on a test bench with a photon-counting detector. Joint processing was compared with temporal subtraction and previously proposed spectral DSA techniques including hybrid subtraction and conventional three-material decomposition. Additional simulation was performed to investigate performance with perfectly calibrated spectral response and sensitivity to patient motion. Results: The improved conditioning of the proposed method effectively reduces bias and noise in the spectral results and allows three-material decomposition with dual-energy spectral measurements. The method achieved more than an order of magnitude variance reduction compared to previously proposed spectral DSA techniques. Compared to temporal subtraction, a mean variance reduction of 23.9% was achieved in simulation and 10.8% in experimental data. The degree of reduction is object-dependent. Noise reduction achieved in physical experiments is slightly lower than that in simulation, likely due to bias from imperfect spectral calibration. The method is equally sensitive to motion compared to temporal subtraction. Conclusion: The proposed method addresses a major image quality challenge limiting previous approaches and outperforms temporal subtraction. Significance: Such improvements facilitate the clinical translation of spectral angiography.
- 16 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (12) , 3501-3514
Joint Temporal and Spectral Processing for Improved Digital Subtraction Angiography Using Photon-Counting Detectors
Objective: Digital subtraction angiography (DSA) is the gold standard modality for diagnostics and guidance for interventional procedures. Spectral imaging has previously been explored for DSA, but severe noise amplification from material decomposition has impeded clinical adoption. We present a novel joint processing strategy that leverages both temporal and spectral information for material decomposition to address this issue. Methods: We develop a model-based material decomposition approach that utilizes the pre- and post-contrast images simultaneously for material estimation. Performance was evaluated on a small-vessel phantom on a test bench with a photon-counting detector. Joint processing was compared with temporal subtraction and previously proposed spectral DSA techniques including hybrid subtraction and conventional three-material decomposition. Additional simulation was performed to investigate performance with perfectly calibrated spectral response and sensitivity to patient motion. Results: The improved conditioning of the proposed method effectively reduces bias and noise in the spectral results and allows three-material decomposition with dual-energy spectral measurements. The method achieved more than an order of magnitude variance reduction compared to previously proposed spectral DSA techniques. Compared to temporal subtraction, a mean variance reduction of 23.9% was achieved in simulation and 10.8% in experimental data. The degree of reduction is object-dependent. Noise reduction achieved in physical experiments is slightly lower than that in simulation, likely due to bias from imperfect spectral calibration. The method is equally sensitive to motion compared to temporal subtraction. Conclusion: The proposed method addresses a major image quality challenge limiting previous approaches and outperforms temporal subtraction. Significance: Such improvements facilitate the clinical translation of spectral angiography.
- Open Access
- 23 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 138192-138200
Microcrack Segmentation of 3D CT Images Based on Multi-Task Learning
As a non-destructive testing technique, industrial CT (Computed Tomography) plays an important role in research and applications of the automatic defect detection for 3D CT images. In recent years, convolutional neural networks (CNNs) have shown great potential in image recognition and segmentation tasks. For industrial 3D CT image detection, how to segment microstructural cracks is the main task at present. The challenge of this task is to identify cracks with low grayscale contrast and small size under unbalanced sample conditions. To address these problems, we propose a crack segmentation method based on the multi-task deep convolutional neural networks. The network architecture consists of a segmentation task module for extracting cracks and a classification task module for improving accuracy, which share part feature maps. We introduce the ECA block based on attention mechanism from Chen et al. to improve the segmentation accuracy. Numerical experimental results show that the proposed method has the better performance compared with other methods. At the same time, the network proposed in this paper has good generalization ability. In the case of only using simulated images training, it still yields good prediction results for real CT images.
- 23 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 138192-138200
Open AccessMicrocrack Segmentation of 3D CT Images Based on Multi-Task Learning
As a non-destructive testing technique, industrial CT (Computed Tomography) plays an important role in research and applications of the automatic defect detection for 3D CT images. In recent years, convolutional neural networks (CNNs) have shown great potential in image recognition and segmentation tasks. For industrial 3D CT image detection, how to segment microstructural cracks is the main task at present. The challenge of this task is to identify cracks with low grayscale contrast and small size under unbalanced sample conditions. To address these problems, we propose a crack segmentation method based on the multi-task deep convolutional neural networks. The network architecture consists of a segmentation task module for extracting cracks and a classification task module for improving accuracy, which share part feature maps. We introduce the ECA block based on attention mechanism from Chen et al. to improve the segmentation accuracy. Numerical experimental results show that the proposed method has the better performance compared with other methods. At the same time, the network proposed in this paper has good generalization ability. In the case of only using simulated images training, it still yields good prediction results for real CT images.
- 9 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (1) , 15-26
One-Step Method for Material Quantitation Using In-Line Tomography With Single Scanning
Objective: Quantitative technique based on In-line phase-contrast computed tomography with single scanning attracts more attention in application due to the flexibility of the implementation. However, the quantitative results usually suffer from artifacts and noise since the phase retrieval and reconstruction are independent (“two-step”) without feedback from the original data. The work aims to investigate a method for material quantitation to improve the image quality of In-line tomography within single scanning. Method: An iterative method based Fresnel diffraction imaging model is developed in this work, which directly reconstructs the refractive index decrement $\delta$ and imaginary $\beta$ of the object from observed data (“one-step”). Moreover, high-quality material decomposition results are obtained by using a linear approximation in the iterative process. Results: Compared with the existing methods, Our method shows a higher peak signal-to-noise ratio and structural similarity in numerical experimental results. Additionally, the quantitation accuracy of the proposed method is greater than 97.2 $\%$ by calculating the equivalent atomic number of the decomposed basic material in the real experiment. Conclusion: We demonstrate that this one-step method greatly reduces noise and improves quantitative reconstruction and decomposition results. Significance: This algorithm has the potential for quantitative imaging research using In-line tomography in future biomedical applications.
- 9 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (1) , 15-26
One-Step Method for Material Quantitation Using In-Line Tomography With Single Scanning
Objective: Quantitative technique based on In-line phase-contrast computed tomography with single scanning attracts more attention in application due to the flexibility of the implementation. However, the quantitative results usually suffer from artifacts and noise since the phase retrieval and reconstruction are independent (“two-step”) without feedback from the original data. The work aims to investigate a method for material quantitation to improve the image quality of In-line tomography within single scanning. Method: An iterative method based Fresnel diffraction imaging model is developed in this work, which directly reconstructs the refractive index decrement $\delta$ and imaginary $\beta$ of the object from observed data (“one-step”). Moreover, high-quality material decomposition results are obtained by using a linear approximation in the iterative process. Results: Compared with the existing methods, Our method shows a higher peak signal-to-noise ratio and structural similarity in numerical experimental results. Additionally, the quantitation accuracy of the proposed method is greater than 97.2 $\%$ by calculating the equivalent atomic number of the decomposed basic material in the real experiment. Conclusion: We demonstrate that this one-step method greatly reduces noise and improves quantitative reconstruction and decomposition results. Significance: This algorithm has the potential for quantitative imaging research using In-line tomography in future biomedical applications.