Ahvand Jalali
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ahvand Jalali has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Mohammad Aldeen
Electrical and Electronic Engineering, The University of Melbourne, Melbourne, Victoria Australia 3010
3 shared publications - A. Rahim-Zadegan
Karlsruhe Institute of Technology Karlsruhe Germany
1 shared publication - Hossein Sangrody
Department of Electrical and Computer Engineering State University of New York at Binghamton Binghamton USA
1 shared publication - Mehdi Ghazavi Dozein
Department of Electrical and Computer Systems Engineering, Monash University, Clayton, VIC, Australia
1 shared publication Mohammad Aldeen
Electrical and Electronic Engineering Department University of Melbourne, Parkville Melbourne Australia
1 shared publication- Mohammad Moulod
Department of Mechanical Engineering, Boukan Branch; Islamic Azad University; Boukan Iran
1 shared publication
Latest Publications
- Top Cited Papers
- 3 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 12 (3) , 1707-1717
Fast Frequency Response From Utility-Scale Hydrogen Electrolyzers
This paper introduces the modelling foundations to study the fast frequency response (FFR) from utility-scale hydrogen electrolyzers (HEs). Specifically, we propose a dynamic model of the HE electrolysis stack, power-electronics interface, and downstream hydrogen process operational constraints, which is suitable for system-level frequency dynamics studies. We then model and study HE FFR dependency on pre-contingency operating point, size, converter's overloading capability, network location, and active power-frequency controller. Different case studies are run on the Australian multi-area test system via dynamic simulations of a 2030 scenario with 50% renewables and in the context of the August 2018 separation event. Our modelling and results illustrate how grid-scale HEs could support a more secure and resilient operation of low-carbon systems for both credible and extreme outages and the role of different design setups and operating conditions and constraints.
- 3 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 12 (3) , 1707-1717
Top Cited PapersFast Frequency Response From Utility-Scale Hydrogen Electrolyzers
This paper introduces the modelling foundations to study the fast frequency response (FFR) from utility-scale hydrogen electrolyzers (HEs). Specifically, we propose a dynamic model of the HE electrolysis stack, power-electronics interface, and downstream hydrogen process operational constraints, which is suitable for system-level frequency dynamics studies. We then model and study HE FFR dependency on pre-contingency operating point, size, converter's overloading capability, network location, and active power-frequency controller. Different case studies are run on the Australian multi-area test system via dynamic simulations of a 2030 scenario with 50% renewables and in the context of the August 2018 separation event. Our modelling and results illustrate how grid-scale HEs could support a more secure and resilient operation of low-carbon systems for both credible and extreme outages and the role of different design setups and operating conditions and constraints.
- Open Access
- 1 April 2019
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 13 (9) , 1509-1519
Undisruptive load curtailment scheme to ensure voltage stability margin
Curtailable loads (CLs) are regarded as one of the last lines of defence to maintain the security and stability of power systems. Nevertheless, if organised carefully, they can also be exploited as preventive security procurement measures for power systems. This is especially true for heavily loaded power systems in which the normal control schemes are already exhausted. In this study, a new power market approach is proposed to utilise CLs’ potential in ensuring voltage stability margin (VSM) for heavily‐loaded power systems. The proposed method aims to provide a mechanism to engage CLs as active players in the power market, and hence, minimise the disruptive effect of the load curtailment. Next, CLs participation in the power market is utilised to minimise the cost of achieving a desired level of VSM, at normal and N − 1 contingency conditions, in a preventive manner. The most efficient load curtailment and power generation pattern are determined, using a modified particle swarm optimisation algorithm, to minimise the system's total cost, while meeting grid's VSM requirements. The simulation results verify that the desired level of VSM can be effectively obtained using the proposed approach, with much less operational cost compared to the established methods.
- 1 April 2019
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 13 (9) , 1509-1519
Open AccessUndisruptive load curtailment scheme to ensure voltage stability margin
Curtailable loads (CLs) are regarded as one of the last lines of defence to maintain the security and stability of power systems. Nevertheless, if organised carefully, they can also be exploited as preventive security procurement measures for power systems. This is especially true for heavily loaded power systems in which the normal control schemes are already exhausted. In this study, a new power market approach is proposed to utilise CLs’ potential in ensuring voltage stability margin (VSM) for heavily‐loaded power systems. The proposed method aims to provide a mechanism to engage CLs as active players in the power market, and hence, minimise the disruptive effect of the load curtailment. Next, CLs participation in the power market is utilised to minimise the cost of achieving a desired level of VSM, at normal and N − 1 contingency conditions, in a preventive manner. The most efficient load curtailment and power generation pattern are determined, using a modified particle swarm optimisation algorithm, to minimise the system's total cost, while meeting grid's VSM requirements. The simulation results verify that the desired level of VSM can be effectively obtained using the proposed approach, with much less operational cost compared to the established methods.
- 3 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Systems Journal
- Vol. 13 (4) , 4169-4180
Short-Term Voltage Stability Improvement via Dynamic Voltage Support Capability of ESS Devices
Modern power systems are undergoing a steady increase in the loading level and higher penetration of renewables. Induction motor (IM) loads and fixed-speed induction generator (FSIG) based wind turbines (WTs) are broadly used in many power systems. Both IMs and FSIGs draw high amounts of reactive power during large disturbances, which pose major problems for short-term voltage stability (ST-VS). In this paper, the effects of IMs, FSIG-based WTs, and over-excitation limiter (OEL) of synchronous generators on ST-VS are analyzed and illustrated. Then, the use of energy storage systems (ESSs) to provide dynamic voltage support (DVS) to power system during and after large disturbances is investigated, as a countermeasure against short-term voltage instability. To implement ESS's DVS capability, the required power injection by the ESS is dynamically determined and then tracked after the occurrence of a disturbance. The effects of implementing fault ride through and time-overload capabilities of ESS's inverter, on ST-VS of the system, are also analyzed. Optimal power factor adjustment for power injection by ESS, from an ST-VS viewpoint, is discussed as well. It is shown that the DVS capability of an ESS can be effectively used against detrimental effects of IMs, FSIGs, and OELs on ST-VS.
- 3 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Systems Journal
- Vol. 13 (4) , 4169-4180
Short-Term Voltage Stability Improvement via Dynamic Voltage Support Capability of ESS Devices
Modern power systems are undergoing a steady increase in the loading level and higher penetration of renewables. Induction motor (IM) loads and fixed-speed induction generator (FSIG) based wind turbines (WTs) are broadly used in many power systems. Both IMs and FSIGs draw high amounts of reactive power during large disturbances, which pose major problems for short-term voltage stability (ST-VS). In this paper, the effects of IMs, FSIG-based WTs, and over-excitation limiter (OEL) of synchronous generators on ST-VS are analyzed and illustrated. Then, the use of energy storage systems (ESSs) to provide dynamic voltage support (DVS) to power system during and after large disturbances is investigated, as a countermeasure against short-term voltage instability. To implement ESS's DVS capability, the required power injection by the ESS is dynamically determined and then tracked after the occurrence of a disturbance. The effects of implementing fault ride through and time-overload capabilities of ESS's inverter, on ST-VS of the system, are also analyzed. Optimal power factor adjustment for power injection by ESS, from an ST-VS viewpoint, is discussed as well. It is shown that the DVS capability of an ESS can be effectively used against detrimental effects of IMs, FSIGs, and OELs on ST-VS.
- 4 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 34 (2) , 1264-1277
Risk-Based Stochastic Allocation of ESS to Ensure Voltage Stability Margin for Distribution Systems
High intermittency in today's renewable-rich distribution systems, and the prohibitive cost of upgrading the system infrastructure, has rendered voltage instability a real concern for heavily loaded systems. Voltage instability of distribution systems can spread to the corresponding transmission grid, as proven by real-life incidents. Recent advances in energy storage systems (ESSs), however, have offered a viable means of enhancing reliability and robustness of power systems. In this paper, optimal placement, sizing, and operation of ESS devices in wind-intensive distribution power systems are studied. The objectives of the paper are to minimize the ESS size (power and energy), required to ensure a desired Voltage Stability Margin (VSM), and minimize reactive power loss and reactive power import from the upstream network. Wind uncertainty has been accounted for through a risk-based stochastic optimization framework. Besides, Active Network Management (ANM) tools, such as tap position of On-Load Tap Changers (OLTCs), modelled by using a new method, and reactive power capabilities of both ESS devices and wind farms, are used as additional means to reduce the required ESS size. The results show that the required ESS significantly increases with an increase in the desired VSM. Nevertheless, the increase can be considerably curtailed by using risk-based VS constraints and ANM tools.
- 4 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 34 (2) , 1264-1277
Risk-Based Stochastic Allocation of ESS to Ensure Voltage Stability Margin for Distribution Systems
High intermittency in today's renewable-rich distribution systems, and the prohibitive cost of upgrading the system infrastructure, has rendered voltage instability a real concern for heavily loaded systems. Voltage instability of distribution systems can spread to the corresponding transmission grid, as proven by real-life incidents. Recent advances in energy storage systems (ESSs), however, have offered a viable means of enhancing reliability and robustness of power systems. In this paper, optimal placement, sizing, and operation of ESS devices in wind-intensive distribution power systems are studied. The objectives of the paper are to minimize the ESS size (power and energy), required to ensure a desired Voltage Stability Margin (VSM), and minimize reactive power loss and reactive power import from the upstream network. Wind uncertainty has been accounted for through a risk-based stochastic optimization framework. Besides, Active Network Management (ANM) tools, such as tap position of On-Load Tap Changers (OLTCs), modelled by using a new method, and reactive power capabilities of both ESS devices and wind farms, are used as additional means to reduce the required ESS size. The results show that the required ESS significantly increases with an increase in the desired VSM. Nevertheless, the increase can be considerably curtailed by using risk-based VS constraints and ANM tools.
- Open Access
- 23 August 2018
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 12 (17) , 4034-4044
Efficient method to identify saddle‐node and limit‐induced bifurcation points of power system
High intermittency in today's renewable‐rich power systems, and the prohibitive cost of upgrading the network infrastructure along with the load growth, has rendered voltage instability an imminent threat for many power systems. This necessitates faster and more efficient ways of identifying the voltage stability (VS) limits, associated with specific bifurcation points of power system model, which are suitable for real‐time applications. To date, continuation power flow (CPF) has conventionally been used to identify bifurcation points of power systems, through plotting power–voltage ( P – V ) curves. However, existing CPF methods are complex and computationally demanding. To tackle this issue, in this study, accurate identification of both saddle‐node and limit‐induced bifurcation points of power systems is carried out by using a new and efficient continuous power flow algorithm, in which all the complexities associated with the existing CPF methods are relaxed. Low execution time (as compared to the existing CPF methods), ease of implementation, and automated applicability, make the proposed algorithm highly suitable for fast and accurate VS assessment of renewable‐rich, uncertain, power systems. Experiments, carried out on several different size power systems, verify that the proposed method can be effectively used to identify the VS limits of practical real‐life power systems, despite its ease of implementation and lower computational burden.
- 23 August 2018
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 12 (17) , 4034-4044
Open AccessEfficient method to identify saddle‐node and limit‐induced bifurcation points of power system
High intermittency in today's renewable‐rich power systems, and the prohibitive cost of upgrading the network infrastructure along with the load growth, has rendered voltage instability an imminent threat for many power systems. This necessitates faster and more efficient ways of identifying the voltage stability (VS) limits, associated with specific bifurcation points of power system model, which are suitable for real‐time applications. To date, continuation power flow (CPF) has conventionally been used to identify bifurcation points of power systems, through plotting power–voltage ( P – V ) curves. However, existing CPF methods are complex and computationally demanding. To tackle this issue, in this study, accurate identification of both saddle‐node and limit‐induced bifurcation points of power systems is carried out by using a new and efficient continuous power flow algorithm, in which all the complexities associated with the existing CPF methods are relaxed. Low execution time (as compared to the existing CPF methods), ease of implementation, and automated applicability, make the proposed algorithm highly suitable for fast and accurate VS assessment of renewable‐rich, uncertain, power systems. Experiments, carried out on several different size power systems, verify that the proposed method can be effectively used to identify the VS limits of practical real‐life power systems, despite its ease of implementation and lower computational burden.
- 1 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 7, 1-6
Modified modal analysis approach for distribution power systems
With the recent global trend for integration of distributed generations (DGs) and energy storage systems (ESSs) into the distribution systems, the placement of these devices is becoming more important. Improving the voltage stability margin (VSM) of the network has been considered as a criterion for the mentioned problem. Accordingly, Modal Analysis (MA) has been used as a tool to identify the best buses to apply compensation, from a voltage stability viewpoint. However, the original MA suffers from an important disadvantage of neglecting the effect of active power variation. In this paper, new MA approaches, applicable to distribution power systems, are proposed which eliminate the original MA's drawback. The results of the proposed methods are validated through VSM analysis and comparison with the results of original MA and L-index. The proposed methods are tested on a commonly used 33-bus radial distribution system.
- 1 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 7, 1-6
Modified modal analysis approach for distribution power systems
With the recent global trend for integration of distributed generations (DGs) and energy storage systems (ESSs) into the distribution systems, the placement of these devices is becoming more important. Improving the voltage stability margin (VSM) of the network has been considered as a criterion for the mentioned problem. Accordingly, Modal Analysis (MA) has been used as a tool to identify the best buses to apply compensation, from a voltage stability viewpoint. However, the original MA suffers from an important disadvantage of neglecting the effect of active power variation. In this paper, new MA approaches, applicable to distribution power systems, are proposed which eliminate the original MA's drawback. The results of the proposed methods are validated through VSM analysis and comparison with the results of original MA and L-index. The proposed methods are tested on a commonly used 33-bus radial distribution system.
- Open Access
DG-Embedded Radial Distribution System Planning Using Binary-Selective PSO
With the increasing rate of power consumption, many new distribution systems need to be constructed to accommodate connecting the new consumers to the power grid. On the other hand, the increasing penetration of renewable distributed generation (DG) resources into the distribution systems and the necessity of optimally place them in the network can dramatically change the problem of distribution system planning and design. In this paper, the problem of optimal distribution system planning including conductor sizing, DG placement, alongside with placement and sizing of shunt capacitors is studied. A new Binary-Selective Particle Swarm Optimization (PSO) approach which is capable of handling all types of continuous, binary and selective variables, simultaneously, is proposed to solve the optimization problem of distribution system planning. The objective of the problem is to minimize the system costs. Load growth rate, cost of energy, cost of power, and inflation rate are all taken into account. The efficacy of the proposed method is tested on a 26-bus distribution system.
Open AccessDG-Embedded Radial Distribution System Planning Using Binary-Selective PSO
With the increasing rate of power consumption, many new distribution systems need to be constructed to accommodate connecting the new consumers to the power grid. On the other hand, the increasing penetration of renewable distributed generation (DG) resources into the distribution systems and the necessity of optimally place them in the network can dramatically change the problem of distribution system planning and design. In this paper, the problem of optimal distribution system planning including conductor sizing, DG placement, alongside with placement and sizing of shunt capacitors is studied. A new Binary-Selective Particle Swarm Optimization (PSO) approach which is capable of handling all types of continuous, binary and selective variables, simultaneously, is proposed to solve the optimization problem of distribution system planning. The objective of the problem is to minimize the system costs. Load growth rate, cost of energy, cost of power, and inflation rate are all taken into account. The efficacy of the proposed method is tested on a 26-bus distribution system.
- 8 July 2016
- Published by Hindawi Limited in International Journal of Energy Research
- Vol. 40 (15) , 2091-2104
Biogas derived from municipal solid waste to generate electrical power through solid oxide fuel cells
Depleting fossil fuels and the pollution resulting from their consumption indicate an urgent need for clean and dependable alternatives such as renewable energies. Biomass is a free and abundant source of renewable energy. Municipal solid waste (MSW) as one of the main categories of biomass has always been an issue for metropolitan cities. It has, however, a high potential for biogas production. In this study, the technical and economic aspects of generating electrical power through solid oxide fuel cells (SOFCs) powered by injecting biogas derived from Tehran's MSW, as a case study, are investigated. The main objectives of the current study are to identify the power generation capability of the process and find out if it can result in a competitive energy resource. The total amount of obtainable methane through anaerobic digestion of MSW and then the achievable power generation capacity by using the obtained biogas are computed using the electrochemical relations inside the SOFC. The economic calculations are carried out to estimate the final price of the generated electricity, taking into account the major capital and ongoing costs of the required equipment. The effect of variations of MSW composition on the power generation capability and final electricity price is also studied. Moreover, the application of a gas turbine (GT) with the SOFC as a hybrid SOFC–GT system to recover the produced heat by SOFC and its effect on the power generation capability and the final electricity price are investigated. Results indicate that around 997.3 tons day−1 biomethane can be generated using Tehran's MSW. By using the SOFC, the produced biogas can generate 300 MWAC electrical power with a final cost of $0.178 kWh−1. By using the hybrid SOFC–GT, the electrical power capacity is increased to 525 MWAC, and the final electricity cost drops to $0.11 kWh−1, which indicates its competitiveness with other common energy resources in the near future, especially by considering different governmental subsidy policies that support renewable energy resources. The considerable environmental benefits of the proposed procedure, from both MSW management and CO2 emission reduction points of view, make it a promising sustainable energy resource for the future. Copyright © 2016 John Wiley & Sons, Ltd.
- 8 July 2016
- Published by Hindawi Limited in International Journal of Energy Research
- Vol. 40 (15) , 2091-2104
Biogas derived from municipal solid waste to generate electrical power through solid oxide fuel cells
Depleting fossil fuels and the pollution resulting from their consumption indicate an urgent need for clean and dependable alternatives such as renewable energies. Biomass is a free and abundant source of renewable energy. Municipal solid waste (MSW) as one of the main categories of biomass has always been an issue for metropolitan cities. It has, however, a high potential for biogas production. In this study, the technical and economic aspects of generating electrical power through solid oxide fuel cells (SOFCs) powered by injecting biogas derived from Tehran's MSW, as a case study, are investigated. The main objectives of the current study are to identify the power generation capability of the process and find out if it can result in a competitive energy resource. The total amount of obtainable methane through anaerobic digestion of MSW and then the achievable power generation capacity by using the obtained biogas are computed using the electrochemical relations inside the SOFC. The economic calculations are carried out to estimate the final price of the generated electricity, taking into account the major capital and ongoing costs of the required equipment. The effect of variations of MSW composition on the power generation capability and final electricity price is also studied. Moreover, the application of a gas turbine (GT) with the SOFC as a hybrid SOFC–GT system to recover the produced heat by SOFC and its effect on the power generation capability and the final electricity price are investigated. Results indicate that around 997.3 tons day−1 biomethane can be generated using Tehran's MSW. By using the SOFC, the produced biogas can generate 300 MWAC electrical power with a final cost of $0.178 kWh−1. By using the hybrid SOFC–GT, the electrical power capacity is increased to 525 MWAC, and the final electricity cost drops to $0.11 kWh−1, which indicates its competitiveness with other common energy resources in the near future, especially by considering different governmental subsidy policies that support renewable energy resources. The considerable environmental benefits of the proposed procedure, from both MSW management and CO2 emission reduction points of view, make it a promising sustainable energy resource for the future. Copyright © 2016 John Wiley & Sons, Ltd.