Abraham Dib
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Abraham Dib has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Javier Flores-Fraile
Department of Surgery, Faculty of Medicine, University of Salamanca, Salamanca, Spain
8 shared publications - Javier Montero
Department of Surgery, Faculty of Medicine, University of Salamanca, Salamanca, Spain
8 shared publications - Yasmina Guadilla
Department of Surgery, Faculty of Medicine, University of Salamanca, 37008 Salamanca, Spain
5 shared publications - Juan Dib Zakkour
Department of Surgery, University of Salamanca, 37007 Salamanca, Spain
4 shared publications - Norberto Quispe-López
Department of Surgery, Faculty of Medicine, University of Salamanca, Salamanca, Spain
4 shared publications - Beatriz Pardal-Peláez
University of Salamanca, Spain
3 shared publications
Latest Publications
- Open Access
- 22 December 2025
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 17 (1) , 7
Biochemical Markers Involved in Bone Remodelling During Orthodontic Tooth Movement
Bone remodelling is a physiological process influenced by mechanical stimuli such as those generated during orthodontic treatment. Biochemical markers allow the phases of remodelling to be identified, its progression to be assessed, alterations to be detected and scaffold-based tissue regeneration to be evaluated. This study reviews the main markers involved in bone formation and resorption, highlighting their clinical relevance. A literature search was conducted in biomedical databases, selecting studies that analysed crevicular gingival fluid samples in areas of tension and compression. The markers were classified according to their function and location, and their baseline values, temporal variations and methods of analysis were compiled. Among the markers of bone formation, Osteoprotegerin (OPG), Transforming Growth factor β1 (TGF-β1) and Interleukin 27 (IL-27) stand out; while resorption markers include Receptor Activator of Nuclear Factor appa β Ligand (RANKL), Tumour Necrosis Factor (TNF-α) and Interleukin 1β (IL-1β). The results show different expression patterns depending on the type of force applied and the timing of the follow-up, allowing molecular profiles associated with each phase of remodelling to be established. This characterisation improves our understanding of tooth movement and provides a basis for the development of more precise scaffolds and functional biomaterials in orthodontics.
- 22 December 2025
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 17 (1) , 7
Open AccessBiochemical Markers Involved in Bone Remodelling During Orthodontic Tooth Movement
Bone remodelling is a physiological process influenced by mechanical stimuli such as those generated during orthodontic treatment. Biochemical markers allow the phases of remodelling to be identified, its progression to be assessed, alterations to be detected and scaffold-based tissue regeneration to be evaluated. This study reviews the main markers involved in bone formation and resorption, highlighting their clinical relevance. A literature search was conducted in biomedical databases, selecting studies that analysed crevicular gingival fluid samples in areas of tension and compression. The markers were classified according to their function and location, and their baseline values, temporal variations and methods of analysis were compiled. Among the markers of bone formation, Osteoprotegerin (OPG), Transforming Growth factor β1 (TGF-β1) and Interleukin 27 (IL-27) stand out; while resorption markers include Receptor Activator of Nuclear Factor appa β Ligand (RANKL), Tumour Necrosis Factor (TNF-α) and Interleukin 1β (IL-1β). The results show different expression patterns depending on the type of force applied and the timing of the follow-up, allowing molecular profiles associated with each phase of remodelling to be established. This characterisation improves our understanding of tooth movement and provides a basis for the development of more precise scaffolds and functional biomaterials in orthodontics.
- Open Access
- 26 January 2024
- Published by MDPI AG in Prosthesis
- Vol. 6 (1) , 119-134
Digital Analysis of Occlusion in Fixed Partial Implant Prostheses: How to Overcome Age-Related Changes in the Stomatognathic System
Due to their lack of periodontal ligaments (PLs) and the differences between dental implants and natural teeth, it is necessary to improve and generate a new occlusal scheme to prolong the life of implants and prostheses. The age and the sex of patients must be considered because of their effects on the stomatognathic system’s physiology. Operators must manage all the changes to obtain good sensations during mastication and a better occlusal scheme for implanting fixed partial prostheses. Dentists should try to protect this type of prosthesis using adjacent teeth and the PL. This is why new digital systems were created. The combination of T-Scan® (digital software for occlusal analysis) and electromyography (EMG) could allow doctors to find areas where it is necessary to act and to find suitable solutions for the problems generated by using conventional methods of occlusal analysis (such as articulating paper). In this study, a new method for establishing occlusion on fixed partial implant prostheses has been created, combining digital systems with conventional articulating paper. This method consists of asking the patient to bite down with different forces and situations in an attempt to achieve Implant-Protected Occlusion (IPO). The use of digital systems has been shown to be more effective than using only conventional systems. This new method allows a safer mode of occlusion which protects implants and prostheses, saving all the differences between them and natural teeth, and increasing the satisfaction of patients. This method also helps to overcome the changes in the stomatognathic system as age increases, adjusting the occlusion to changes in PLs with age.
- 26 January 2024
- Published by MDPI AG in Prosthesis
- Vol. 6 (1) , 119-134
Open AccessDigital Analysis of Occlusion in Fixed Partial Implant Prostheses: How to Overcome Age-Related Changes in the Stomatognathic System
Due to their lack of periodontal ligaments (PLs) and the differences between dental implants and natural teeth, it is necessary to improve and generate a new occlusal scheme to prolong the life of implants and prostheses. The age and the sex of patients must be considered because of their effects on the stomatognathic system’s physiology. Operators must manage all the changes to obtain good sensations during mastication and a better occlusal scheme for implanting fixed partial prostheses. Dentists should try to protect this type of prosthesis using adjacent teeth and the PL. This is why new digital systems were created. The combination of T-Scan® (digital software for occlusal analysis) and electromyography (EMG) could allow doctors to find areas where it is necessary to act and to find suitable solutions for the problems generated by using conventional methods of occlusal analysis (such as articulating paper). In this study, a new method for establishing occlusion on fixed partial implant prostheses has been created, combining digital systems with conventional articulating paper. This method consists of asking the patient to bite down with different forces and situations in an attempt to achieve Implant-Protected Occlusion (IPO). The use of digital systems has been shown to be more effective than using only conventional systems. This new method allows a safer mode of occlusion which protects implants and prostheses, saving all the differences between them and natural teeth, and increasing the satisfaction of patients. This method also helps to overcome the changes in the stomatognathic system as age increases, adjusting the occlusion to changes in PLs with age.
- Open Access
Comparative Evaluation of the Digital Workflow and Conventional Method in Manufacturing Complete Removal Prostheses
The aging population in developed countries has increased the number of edentulous patients and, therefore, the need for prosthetic rehabilitation to improve their quality of life. Complete dentures are the main treatment option in these cases. The use of CAD/CAM (Computer Aided Design/Computer Aided Manufacturing) in dentistry has improved clinical protocols and outcomes, achieving a reduction in work time and economic costs for the patients. The main objective of this review was to compare the characteristics of conventional and digital dentures, attempting to determine whether the use of new technologies represents an improvement in the properties of removable complete dentures. A bibliographic review was carried out in the PubMed/MEDLINE, Cochrane Library, Scielo, and Embase databases. With the initial search, 157 articles were obtained. After applying the inclusion and exclusion criteria, 64 publications were selected for this bibliographic review. The different conclusions of the studies consulted were compared regarding fit and retention, fracture resistance, surface roughness, biocompatibility, and aesthetics, taking into account the different methods of prostheses fabrication. In general, digital prostheses have shown better mechanical properties and, consequently, better biocompatibility and aesthetics than conventional prostheses. However, the obtained results were very heterogeneous, preventing a supported conclusion.
Open AccessComparative Evaluation of the Digital Workflow and Conventional Method in Manufacturing Complete Removal Prostheses
The aging population in developed countries has increased the number of edentulous patients and, therefore, the need for prosthetic rehabilitation to improve their quality of life. Complete dentures are the main treatment option in these cases. The use of CAD/CAM (Computer Aided Design/Computer Aided Manufacturing) in dentistry has improved clinical protocols and outcomes, achieving a reduction in work time and economic costs for the patients. The main objective of this review was to compare the characteristics of conventional and digital dentures, attempting to determine whether the use of new technologies represents an improvement in the properties of removable complete dentures. A bibliographic review was carried out in the PubMed/MEDLINE, Cochrane Library, Scielo, and Embase databases. With the initial search, 157 articles were obtained. After applying the inclusion and exclusion criteria, 64 publications were selected for this bibliographic review. The different conclusions of the studies consulted were compared regarding fit and retention, fracture resistance, surface roughness, biocompatibility, and aesthetics, taking into account the different methods of prostheses fabrication. In general, digital prostheses have shown better mechanical properties and, consequently, better biocompatibility and aesthetics than conventional prostheses. However, the obtained results were very heterogeneous, preventing a supported conclusion.
- Open Access
- 13 March 2023
- Published by MDPI AG in Prosthesis
- Vol. 5 (1) , 295-309
Marginal Bone Loss and Treatment Complications with Mandibular Overdentures Retained by Two Immediate or Conventionally Loaded Implants—A Randomized Clinical Trial
This study aimed to assess marginal bone loss and complication rates of mandibular overdentures retained on two implants with conventional and immediate loading protocols. Twenty edentulous patients were treated with mandibular two-implant-retained overdentures and new complete maxillary dentures. In one half of the sample, the implants were loaded immediately by VulkanLoc® abutments. In the counterpart group, these abutments were connected to the implants two months after implant placement (conventional protocol). Treatment outcomes were evaluated at 2, 6, and 12 months after implant placement. According to the pre- and post-insertion radiographs, there was a mean marginal bone loss of 0.25–0.59 mm (CI 95%) after 13.4 ± 2.1 months of follow-up. There were no significant differences between groups. The failure rate (percentage of implants failing per year) was slightly higher in the conventional loading group (14.0 ± 32.7%) than in the immediate loading group (8.3 ± 18.0%). The findings of the present study suggested that there were no differences in marginal bone loss observed at one year for immediately loaded implants (0.40–0.39 mm) versus conventionally loaded implants (0.44- 0.36 mm) placed for the retention of mandibular overdentures. There were no differences in primary and secondary stability of immediately loaded versus conventional implants; however, in the conventional loading group, stability increased significantly between implant placement compared at both 6 and 12 months post-placement.
- 13 March 2023
- Published by MDPI AG in Prosthesis
- Vol. 5 (1) , 295-309
Open AccessMarginal Bone Loss and Treatment Complications with Mandibular Overdentures Retained by Two Immediate or Conventionally Loaded Implants—A Randomized Clinical Trial
This study aimed to assess marginal bone loss and complication rates of mandibular overdentures retained on two implants with conventional and immediate loading protocols. Twenty edentulous patients were treated with mandibular two-implant-retained overdentures and new complete maxillary dentures. In one half of the sample, the implants were loaded immediately by VulkanLoc® abutments. In the counterpart group, these abutments were connected to the implants two months after implant placement (conventional protocol). Treatment outcomes were evaluated at 2, 6, and 12 months after implant placement. According to the pre- and post-insertion radiographs, there was a mean marginal bone loss of 0.25–0.59 mm (CI 95%) after 13.4 ± 2.1 months of follow-up. There were no significant differences between groups. The failure rate (percentage of implants failing per year) was slightly higher in the conventional loading group (14.0 ± 32.7%) than in the immediate loading group (8.3 ± 18.0%). The findings of the present study suggested that there were no differences in marginal bone loss observed at one year for immediately loaded implants (0.40–0.39 mm) versus conventionally loaded implants (0.44- 0.36 mm) placed for the retention of mandibular overdentures. There were no differences in primary and secondary stability of immediately loaded versus conventional implants; however, in the conventional loading group, stability increased significantly between implant placement compared at both 6 and 12 months post-placement.
- Open Access
- 18 November 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (22) , 6819
Active Tactile Sensibility in Implant Prosthesis vs. Complete Dentures: A Psychophysical Study
Background and Objectives: Proprioceptive information from natural dentition and adjacent oral tissues enables correct masticatory function, avoiding damage to the teeth. Periodontium is the main source of this relevant information, and when a tooth is lost, all this proprioceptive sensibility relies on receptors from muscles, the mucous membrane or the temporomandibular joint, and this sensibility gets worse. Active tactile sensibility measures this proprioceptive capability in microns by psychophysical studies consisting of introducing thin metal foils between patients’ dental arches during chewing to see if they are able to notice them or not. Osseoperception is a complex phenomenon that seems to improve this sensibility in patients wearing dental implants. The objective of this investigation is to measure this sensibility in different prosthetic situations by performing a psychophysical investigation. Material and Methods: We divided 67 patients in three groups depending on their prosthetic situation and performed a psychophysical study by introducing aluminium foils of different thicknesses in order to establish an active tactile sensibility threshold in every group. We also measured variables such as prosthetic wearing time, age or gender to see how they may influence threshold values. We used Student’s t-test and Mann–Whitney U tests to analyse these results. Results: Active tactile sensibility threshold values in implants are lower than those from complete dentures but higher than values in natural dentition. However, values in implants are closer to natural dentition than complete denture values. Age, gender or prosthetic wearing time have no influence in active tactile sensibility thresholds. Conclusion: Active tactile sensibility threshold values depend on prosthetic rehabilitations and the mechanoreceptors involved in every situation. Implant prosthesis presents an increased active tactile sensibility thanks to osseoperception phenomenon.
- 18 November 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (22) , 6819
Open AccessActive Tactile Sensibility in Implant Prosthesis vs. Complete Dentures: A Psychophysical Study
Background and Objectives: Proprioceptive information from natural dentition and adjacent oral tissues enables correct masticatory function, avoiding damage to the teeth. Periodontium is the main source of this relevant information, and when a tooth is lost, all this proprioceptive sensibility relies on receptors from muscles, the mucous membrane or the temporomandibular joint, and this sensibility gets worse. Active tactile sensibility measures this proprioceptive capability in microns by psychophysical studies consisting of introducing thin metal foils between patients’ dental arches during chewing to see if they are able to notice them or not. Osseoperception is a complex phenomenon that seems to improve this sensibility in patients wearing dental implants. The objective of this investigation is to measure this sensibility in different prosthetic situations by performing a psychophysical investigation. Material and Methods: We divided 67 patients in three groups depending on their prosthetic situation and performed a psychophysical study by introducing aluminium foils of different thicknesses in order to establish an active tactile sensibility threshold in every group. We also measured variables such as prosthetic wearing time, age or gender to see how they may influence threshold values. We used Student’s t-test and Mann–Whitney U tests to analyse these results. Results: Active tactile sensibility threshold values in implants are lower than those from complete dentures but higher than values in natural dentition. However, values in implants are closer to natural dentition than complete denture values. Age, gender or prosthetic wearing time have no influence in active tactile sensibility thresholds. Conclusion: Active tactile sensibility threshold values depend on prosthetic rehabilitations and the mechanoreceptors involved in every situation. Implant prosthesis presents an increased active tactile sensibility thanks to osseoperception phenomenon.
- Open Access
Effect Morphology and Surface Treatment of the Abutments of Dental Implants on the Dimension and Health of Peri-Implant Biological Space
Statement of the problem: The gingival configuration around implant abutments is of paramount importance for preserving the underlying marginal bone, and hence for the long-term success of dental implants. Objective: The objective was to study, clinically and histologically, the effects of the change in the morphology of abutments connected to the endosseous implant, and of their surface treatment. In particular, the objective was to ascertain the effect of changing the shape of the transepithelial pillar and the treatment of its surface on the dimensions, quality and health of the components of the peri-implant biological space, such as the dimensions of the epithelial and connective tissues of the biological space, the concentration of inflammatory cells and the density of collagen fibers. Methods: A clinical trial of 10 patients with a totally edentulous maxilla, who had four implants (IPX4010_GALIMPLANT®, Sarria, Spain) inserted in the area of the first and second molars on both sides with computer-guided implant surgery, was conducted with the final purpose of assessing the quality of the peri-implant soft tissue attachment around the transepithelial abutments which were employed (aesthetic machined (RM), aesthetic anodized (RA), slim machined (SM) and slim anodized (SA)). At 8 weeks and following the collection of the samples (removal of the implant-abutment assembly with its surrounding hard and soft tissue) and their processing for subsequent histological and histomorphometric analysis in order to study the dimensions, quality and health of the peri-implant soft tissue area, the variables previously mentioned were determined according to the aims of the study. By using appropriate diameter trephine in order to obtain a useful fringe of soft tissue around the transepithelial pillars, ANOVA and chi-square tests were performed. Results: The SPSS statistical analysis ANOVA results revealed that the machined slim abutments have a better performance considering the variables analyzed with epithelial and connective attachment heights of 1.52 mm and 2.3 mm, respectively, and that connective density (density of collagen fibers) was high at 85.7% of the sample size affected by the design for the slim abutments and 92.9% of the high-density sample size affected by the surface treatment for the machined surface. Conclusions: All variables studied, despite the small sample size, showed the superiority of the slim machined abutment among the four groups.
Open AccessEffect Morphology and Surface Treatment of the Abutments of Dental Implants on the Dimension and Health of Peri-Implant Biological Space
Statement of the problem: The gingival configuration around implant abutments is of paramount importance for preserving the underlying marginal bone, and hence for the long-term success of dental implants. Objective: The objective was to study, clinically and histologically, the effects of the change in the morphology of abutments connected to the endosseous implant, and of their surface treatment. In particular, the objective was to ascertain the effect of changing the shape of the transepithelial pillar and the treatment of its surface on the dimensions, quality and health of the components of the peri-implant biological space, such as the dimensions of the epithelial and connective tissues of the biological space, the concentration of inflammatory cells and the density of collagen fibers. Methods: A clinical trial of 10 patients with a totally edentulous maxilla, who had four implants (IPX4010_GALIMPLANT®, Sarria, Spain) inserted in the area of the first and second molars on both sides with computer-guided implant surgery, was conducted with the final purpose of assessing the quality of the peri-implant soft tissue attachment around the transepithelial abutments which were employed (aesthetic machined (RM), aesthetic anodized (RA), slim machined (SM) and slim anodized (SA)). At 8 weeks and following the collection of the samples (removal of the implant-abutment assembly with its surrounding hard and soft tissue) and their processing for subsequent histological and histomorphometric analysis in order to study the dimensions, quality and health of the peri-implant soft tissue area, the variables previously mentioned were determined according to the aims of the study. By using appropriate diameter trephine in order to obtain a useful fringe of soft tissue around the transepithelial pillars, ANOVA and chi-square tests were performed. Results: The SPSS statistical analysis ANOVA results revealed that the machined slim abutments have a better performance considering the variables analyzed with epithelial and connective attachment heights of 1.52 mm and 2.3 mm, respectively, and that connective density (density of collagen fibers) was high at 85.7% of the sample size affected by the design for the slim abutments and 92.9% of the high-density sample size affected by the surface treatment for the machined surface. Conclusions: All variables studied, despite the small sample size, showed the superiority of the slim machined abutment among the four groups.
- 10 June 2022
- Published by Elsevier in Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology
- Vol. 135 (2) , 192-203
Preliminary results of customized bone graft made by robocasting hydroxyapatite and tricalcium phosphates for oral surgery
- 10 June 2022
- Published by Elsevier in Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology
- Vol. 135 (2) , 192-203
Preliminary results of customized bone graft made by robocasting hydroxyapatite and tricalcium phosphates for oral surgery
- Open Access
Evaluation of the Effectiveness of Dry Needling in the Treatment of Myogenous Temporomandibular Joint Disorders
Background and Objectives: The objective of our clinical trial was to determine the effectiveness of the deep dry needling technique (DDN) (neuromuscular deprogramming) as a first step in the treatment of temporomandibular disorders. Methods and Materials: The double-blind randomized clinical trial comprised 36 patients meeting the inclusion criteria who had signed the corresponding informed consent form. The participants were randomly distributed into two groups, the Experimental group (Group E) and the Control group (Group C). Group E received bilateral DDN on the masseter muscle, while Group C received a simulation of the technique (PN). All the participants were evaluated three times: pre-needling, 10 min post-needling, and through a follow-up evaluation after 15 days. These evaluations included, among other tests: pain evaluation using the Visual Analog Scale (VAS) and bilateral muscle palpation with a pressure algometer; evaluation of the opening pattern and range of the mouth, articular sounds and dental occlusion using T-scans; and electromyography, which was used to evaluate the muscle tone of the masseter muscles, in order to control changes in mandibular position. Results: Digital control of occlusion using Tec-Scan (digital occlusion analysis) showed a significant reduction both in the time of posterior disclusion and in the time needed to reach maximum force in an MI position after needling the muscle, which demonstrated that there were variations in the static position and the trajectory of the jaw. The symmetry of the arch while opening and closing the mouth was recovered in a centric relation, with an increase in the opening range of the mouth after the procedure. Conclusions: facial pain is significantly reduced and is accompanied by a notable reduction in muscle activity after needling its trigger points.
Open AccessEvaluation of the Effectiveness of Dry Needling in the Treatment of Myogenous Temporomandibular Joint Disorders
Background and Objectives: The objective of our clinical trial was to determine the effectiveness of the deep dry needling technique (DDN) (neuromuscular deprogramming) as a first step in the treatment of temporomandibular disorders. Methods and Materials: The double-blind randomized clinical trial comprised 36 patients meeting the inclusion criteria who had signed the corresponding informed consent form. The participants were randomly distributed into two groups, the Experimental group (Group E) and the Control group (Group C). Group E received bilateral DDN on the masseter muscle, while Group C received a simulation of the technique (PN). All the participants were evaluated three times: pre-needling, 10 min post-needling, and through a follow-up evaluation after 15 days. These evaluations included, among other tests: pain evaluation using the Visual Analog Scale (VAS) and bilateral muscle palpation with a pressure algometer; evaluation of the opening pattern and range of the mouth, articular sounds and dental occlusion using T-scans; and electromyography, which was used to evaluate the muscle tone of the masseter muscles, in order to control changes in mandibular position. Results: Digital control of occlusion using Tec-Scan (digital occlusion analysis) showed a significant reduction both in the time of posterior disclusion and in the time needed to reach maximum force in an MI position after needling the muscle, which demonstrated that there were variations in the static position and the trajectory of the jaw. The symmetry of the arch while opening and closing the mouth was recovered in a centric relation, with an increase in the opening range of the mouth after the procedure. Conclusions: facial pain is significantly reduced and is accompanied by a notable reduction in muscle activity after needling its trigger points.
- Open Access
Importance of Osseoperception and Tactile Sensibility during Masticatory Function in Different Prosthetic Rehabilitations: A Review
Background and Objectives: Tactile sensibility is an important characteristic for evaluating the masticatory efficiency in different occlusal situations. When a tooth is extracted, relevant proprioceptors from the periodontal ligament get lost; and after the rehabilitation of this abscess by means of oral prosthesis, this sensibility decreases influencing masticatory function. Osseoperception is a sensitive phenomenon associated with dental implants that allows an increased tactile sensibility to those wearing implant prostheses. The purpose of this study was to determine the difference in tactile sensibility values between implant prosthesis, complete dentures, and natural teeth through a review of the available literature. Materials and Methods. In order to dissect the information, 24 articles from 2004 to 2021 were analyzed from MEDLINE, PubMed Central, and Web of Science databases. These articles were directly related to measuring tactile sensibility in different situations and demonstrating the influence of osseoperception in an improved masticatory function. Results: Tactile sensibility in implant prosthesis is slightly reduced compared with natural dentition but presents improved values with regard to complete dentures. Conclusions: Implant prosthesis are more effective during masticatory function than complete dentures, as they present an increased tactile sensibility, very similar to that present in natural dentition. This enhanced sensibility in implants is due to the osseoperception phenomenon.
Open AccessImportance of Osseoperception and Tactile Sensibility during Masticatory Function in Different Prosthetic Rehabilitations: A Review
Background and Objectives: Tactile sensibility is an important characteristic for evaluating the masticatory efficiency in different occlusal situations. When a tooth is extracted, relevant proprioceptors from the periodontal ligament get lost; and after the rehabilitation of this abscess by means of oral prosthesis, this sensibility decreases influencing masticatory function. Osseoperception is a sensitive phenomenon associated with dental implants that allows an increased tactile sensibility to those wearing implant prostheses. The purpose of this study was to determine the difference in tactile sensibility values between implant prosthesis, complete dentures, and natural teeth through a review of the available literature. Materials and Methods. In order to dissect the information, 24 articles from 2004 to 2021 were analyzed from MEDLINE, PubMed Central, and Web of Science databases. These articles were directly related to measuring tactile sensibility in different situations and demonstrating the influence of osseoperception in an improved masticatory function. Results: Tactile sensibility in implant prosthesis is slightly reduced compared with natural dentition but presents improved values with regard to complete dentures. Conclusions: Implant prosthesis are more effective during masticatory function than complete dentures, as they present an increased tactile sensibility, very similar to that present in natural dentition. This enhanced sensibility in implants is due to the osseoperception phenomenon.
- Open Access
- 5 October 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (19) , 4589
Patient-Centered Treatment Outcomes with Full-Arch PEEK Rehabilitation Supported on Four Immediate or Conventionally Loaded Implants. A Randomized Clinical Trial
This study aims to assess the treatment outcomes (functional and subjective) of full-arch fixed hybrid rehabilitations made of PEEK (poly-ether-ether-ketone) with milled crowns of nano-filled composite (NFC) supported on four to six implants. In this randomized clinical trial, 34 edentate patients in the upper and/or the lower jaws were treated with the fixed hybrid dentures. In 16 patients (47.1% of the sample), the implants were loaded immediately (IL) by means of a provisional fixed rehabilitation made of PMMA (polymethylmethacrylate) screwed on Multi-Unit (MU) abutments connected after emplacement of the implant; however, in the counterparts (n = 18) these MU abutments were covered by healing caps and were left unloaded during two months (conventional loading protocol—CL), when all patients received a fixed hybrid PEEK-NFC rehabilitation on the upper and/or the lower jaw. Treatment outcomes were assessed 12 months after prostheses delivery. Functional outcomes were calculated according to masticatory performance, estimated by mixing ability tests of two colored chewing gums after ten chewing strokes, by the occlusal force/area recorded by pressure-sensitive sheets, and by electromyography of masseters and temporal muscles at maximum biteforce. The subjective outcomes of the treatment were assessed using both the oral satisfaction scale (visual analog scale) and the Spanish version of the Oral Health Impact Profile (OHIP-20). The findings of the present study showed that treatment with fixed PEEK-NFC hybrid prostheses significantly improved the masticatory performance, bite force, occlusal pattern, quality of life, and satisfaction, with the IL group being those with significantly higher occlusal bite forces and greater satisfaction in comparison with CL group. It should be concluded that PEEK-NFC hybrid prostheses can improve several patient-centered outcomes and that loading protocol significantly affects the patient’s self-rated satisfaction.
- 5 October 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (19) , 4589
Open AccessPatient-Centered Treatment Outcomes with Full-Arch PEEK Rehabilitation Supported on Four Immediate or Conventionally Loaded Implants. A Randomized Clinical Trial
This study aims to assess the treatment outcomes (functional and subjective) of full-arch fixed hybrid rehabilitations made of PEEK (poly-ether-ether-ketone) with milled crowns of nano-filled composite (NFC) supported on four to six implants. In this randomized clinical trial, 34 edentate patients in the upper and/or the lower jaws were treated with the fixed hybrid dentures. In 16 patients (47.1% of the sample), the implants were loaded immediately (IL) by means of a provisional fixed rehabilitation made of PMMA (polymethylmethacrylate) screwed on Multi-Unit (MU) abutments connected after emplacement of the implant; however, in the counterparts (n = 18) these MU abutments were covered by healing caps and were left unloaded during two months (conventional loading protocol—CL), when all patients received a fixed hybrid PEEK-NFC rehabilitation on the upper and/or the lower jaw. Treatment outcomes were assessed 12 months after prostheses delivery. Functional outcomes were calculated according to masticatory performance, estimated by mixing ability tests of two colored chewing gums after ten chewing strokes, by the occlusal force/area recorded by pressure-sensitive sheets, and by electromyography of masseters and temporal muscles at maximum biteforce. The subjective outcomes of the treatment were assessed using both the oral satisfaction scale (visual analog scale) and the Spanish version of the Oral Health Impact Profile (OHIP-20). The findings of the present study showed that treatment with fixed PEEK-NFC hybrid prostheses significantly improved the masticatory performance, bite force, occlusal pattern, quality of life, and satisfaction, with the IL group being those with significantly higher occlusal bite forces and greater satisfaction in comparison with CL group. It should be concluded that PEEK-NFC hybrid prostheses can improve several patient-centered outcomes and that loading protocol significantly affects the patient’s self-rated satisfaction.