YYYongfeng Yang

Yongfeng Yang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yongfeng Yang has a total of 171 co-authors. Here are the top co-authors by number of shared publications:

  • Dong Liang

    Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences

    23 shared publications
  • Hairong Zheng

    Shenzhen Institute of Advanced Technology

    22 shared publications
  • Zhanli Hu

    Research Center for Medical AI, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China

    22 shared publications
  • Ning Ren

    Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences

    18 shared publications
  • Zhonghua Kuang

    Microelectronics and Optoelectronics Technology Key Laboratory of Hunan Higher Education, School of Physics and Electronic Electrical Engineering, Xiangnan University, Chenzhou 423000, China

    16 shared publications
  • Xiaohui Wang

    Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China

    14 shared publications

Latest Publications

  • Beam-width-corrected DOI resolution measurement of dual-ended readout PET detectors

    by Hui Huang, Gangxin Hou, Haonan Li, Sen Yang, Zhonghua Kuang, Ning Ren, Yongfeng Yang, Zheng Liu

    Objective. Dual-ended readout PET detectors provide depth-of-interaction (DOI) information for reducing parallax errors in high-resolution PET imaging. This study compared LYSO detectors with different inter-crystal reflectors and investigated the effect of irradiation beam width on DOI resolution measurements under electronic collimation. Approach. Two 28 × 28 LYSO arrays with 0.75 × 0.75 × 10 mm 3 crystals and BaSO 4 or E60 reflectors were characterized in terms of flood-map quality, energy resolution, and DOI resolution. Part of E60 detector (8 × 8 crystals) was further measured using three irradiation geometries with beam widths of 0.80 mm, 0.62 mm, and 0.46 mm. A beam-width correction was applied to the measured DOI resolution, and the effects of energy selection and empirical flood-map-based inter-crystal scattering (ICS) filtering were evaluated. Main results. The BaSO 4 detector showed better flood-map quality and energy resolution, whereas the E60 detector showed better DOI resolution. In the 400–650 keV energy window, the measured average DOI resolutions of entire 28 × 28 LYSO pixels with irradiation beam width of 1.00 mm were 1.92 and 1.75 mm for the BaSO 4 and E60 detectors, respectively. For the selected 8 × 8 crystal region of the E60 detector, the corrected DOI resolution by subtracting the irradiation beam width improved from 1.19 mm for all events to 1.01 mm after energy selection, and further to 0.86 mm after additional empirical flood-map-based ICS filtering. Significance. Irradiation beam width introduces a geometry-dependent contribution to DOI resolution measurements. Beam-width correction enables more consistent DOI characterization under different irradiation geometries.

  • Open Access

    Initial Performance of a Prototype Small Animal PET Scanner Consisting of Long Semi-Monolithic Scintillator Detectors

    by Zhonghua Kuang, Samuel Mungai Kinyanjui, Ling Zhang, Ning Ren, Haonan Li, Zhanli Hu, Yongfeng Yang, Zheng Liu

    Semi-monolithic scintillator detectors possess not only the inherent depth of interaction (DOI) encoding capability of monolithic scintillator detectors but also reduced edge effects compared to monolithic scintillator detectors. The performance of a small animal PET scanner consisting of long semi-monolithic scintillator detectors was investigated in this work. Two semi-monolithic scintillator detectors composed of 12 LYSO slabs of 0.96 × 56 × 10 mm3 with ESR or BaSO4 as the reflectors were manufactured. First, a prototype small animal PET scanner consisting of the two semi-monolithic detectors and a rotation platform was built. The spatial resolution of the prototype PET scanner was measured using a 22Na point source. Second, the sensitivity and imaging performance of a full-ring small animal PET scanner consisting of 20 semi-monolithic detectors was simulated using GATE software. The proposed position calibration method for semi-monolithic scintillator detectors effectively addressed non-uniform position responses in both the monolithic and DOI directions and was suitable for system-level PET scanner calibration. Using experimental data from the two-detector prototype PET scanner, spatial resolution better than 0.65 mm was obtained with point spread function (PSF) modelling. In Monte Carlo simulations of a full-ring PET scanner consisting of 20 such detectors, a peak sensitivity of 5.45% was achieved, and rods with a diameter of 0.75 mm were clearly resolved in phantom images reconstructed with PSF modelling. Long semi-monolithic scintillator detector represents a promising candidate for developing small animal PET systems to achieve sub-millimeter uniform spatial resolution, good sensitivity, and reduced cost.

  • Open Access

    Performance of high-resolution PET detectors consisting of long GAGG slabs with different reflectors

    by Zhonghua Kuang, Samuel Mungai Kinyanjui, Ling Zhang, Ning Ren, Zheng Liu, Qiaolai Tan, Jianquan Huang, Zhanli Hu, Yongfeng Yang

    Depth of interaction (DOI) encoding detectors are essential for pre-clinical or organ-dedicated PET scanners to simultaneously achieve high spatial resolut

  • Open Access

    Effects of inter-crystal scattering events on the performance of SIAT aPET

    by Zhonghua Kuang, Ling Zhang, Ning Ren, Zheng Liu, Haiming Deng, Yalan Li, Ming Niu, Tao Sun, Zhanli Hu, Yongfeng Yang

    Objective. The probability of 511 keV γ-rays undergoing inter-crystal scattering (ICS) in current positron emission tomography (PET) detectors is high. The objective of this research is to study the impact of the ICS events on the performance of the small animal SIAT aPET scanner. Approach. The SIAT aPET scanner is composed of 48 detectors organized in 4 rings with each ring containing 12 detectors. Each detector is composed of a 23 × 23 crystal array dual-ended read out by two 8 × 8 silicon photomultiplier arrays with resistor network circuits. In this work, a specific method was proposed to identify the single interaction (non-ICS) and ICS events (both interactions are undergoing ICS). A point source, two hot rod phantoms and a NEMA image quality (IQ) phantom were scanned and images were reconstructed using different types of events. Main results. The average full width at half maximum spatial resolutions of the point source obtained with all, non-ICS and ICS events are 0.62 mm, 0.52 mm, and 0.97 mm, respectively. The 1.0 mm diameter rods can be clearly resolved from the images of the ultra-micro hot rod phantom obtained with both all events and only the non-ICS events, but the image obtained with the non-ICS events show a 40% better peak-to-valley ratio for the 1.0 mm rods. The 1.35 mm rods can be clearly resolved from the image obtained with the ICS events. The images of the NEMA IQ phantom showed that the contrast recovery coefficients for hot rods with 1–5 mm diameters were improved by 24% in average, but the signal-to-noise ratio of the uniform region was decreased by 46% with the rejection of the ICS events (at least one γ-ray undergoing ICS). Significance. The results of this work provide useful guidance on whether it is necessary to use detectors that are capable of identifying the ICS events for PET scanners of different spatial resolution.


  • Open Access

    Reconstruction of total-body multi parametric images with shortened-duration dynamic [68Ga]Ga-PSMA-11 and [68Ga]Ga-FAPI-04 PET scans

    by Yunlong Gao, Zixiang Chen, Wenjie Zhao, Yongfeng Yang, Hairong Zheng, Dong Liang, Jianjun Liu, Ruohua Chen, Zhanli Hu

    Objective. The lengthy 1 h dynamic positron emission tomography (PET) scans discomfort patients, add motion artifacts, and inflate costs, highlighting the need for tech advancements to reduce scan times. Therefore, we attempted to reconstruct multi-parametric imaging with only 20 min dynamic PET frames through deep learning techniques. Approach. Total-body PET data from 49 subjects (18 [68Ga]Ga-FAPI-04 and 31 [68Ga]Ga-prostate-specific membrane antigen (PSMA)-11) at Renji Hospital were used. We employed the dynamic PET frames prediction, parametric linear fitting and generative adversarial network to form the whole deep learning framework accomplishing reconstruction of multi-parametric images ([68Ga]Ga-FAPI-04: K 1 , DV and v B ; [68Ga]Ga-PSMA-11: K 1 , K i and v B ) from 20 min dynamic PET frames. The peak signal-to-noise ratio (PSNR) and structural similarity index measure (SSIM) were used to evaluate the quality of the synthesized results. Statistical analyses, including Pearson correlation coefficient (PCC) and violin plot, were also used for the reconstruction assessments. Main results. The reconstructed multi-parametric images using the proposed technique closely resembled their full-time parametric counterparts, demonstrating high image quality across various tissue types. The reconstructed images resulting from the [68Ga]Ga-FAPI-04 and [68Ga]Ga-PSMA-11 tracers outperform 5 comparison methods, yielding average PSNR values of 35.5535 dB and 36.4040 dB, along with SSIM scores of 0.9798 and 0.9630, respectively. Additionally, the PCCs within the region of interests exhibited strong correlations (above 0.92) with the ground truth. Moreover, the imaging results in the pancreatic and prostate areas matched well with full-time parametric images. Significance. Our approach shortens the scan duration of dynamic PET from above one hour to 20 min, which greatly improves the experience for patients and reduces motion artifacts and costs.


  • Open Access

    Texture features-guided image reconstruction kernel method for 18F-FDG delayed PET imaging

    by Zhichao Song, Jianping Zhang, Zixiang Chen, Zhenxing Huang, Wenbo Li, Xi Fang, Catherine C Liu, Yunlong Gao, Yihan Wang, Yongfeng Yang, et al.

    Objective. Positron emission tomography (PET) is a crucial imaging technology that is widely used for cancer staging and treatment response assessment. Delayed PET imaging (or dual-time-point imaging) involves a second PET acquisition step approximately 33 min after the initial scan in this study, providing more dynamic biological information, improving lesion detectability, and allowing patients to rest during the scan. However, with increasing time, the number of photons in the second scan decreases, which raises the difficulty of the second PET image reconstruction process. Due to the extended time between the tracer injection step and the second PET scan, the photon count during the second scan decreases, leading to difficulties when reconstructing the second PET image. To effectively reconstruct the second image, we propose a new reconstruction algorithm that utilizes texture features from the first PET image to assist in reconstructing the second PET image. Approach. In this study, to effectively reconstruct delayed-scan PET images, we propose a novel reconstruction method. This method introduces texture features from the first PET image to assist in the process of reconstructing the second PET image, thereby enabling the PET images to more effectively retain their clinical significance. We extract texture features using the gray level co-occurrence matrix, then combine these features with additional gray-level characteristics to form a new feature vector, which is subsequently incorporated into the kernel-based reconstruction method, enhancing the reconstruction process and improving the quality of the delayed PET image reconstruction. We used the peak signal-to-noise ratio, the mean absolute error and structural similarity index measure (SSIM) as image quality assessment metrics and compared our method with other existing reconstruction methods. In addition, we conducted a more detailed comparison across regions of interest (ROIs). Main results. Our experiments were conducted with data acquired from 32 real patients. Compared with other competing methods, our approach achieved a certain level of improvement, with a PSNR value of 32.53 dB and an SSIM of 0.904. Relative to those of the maximum likelihood expectation maximization method, these metrics improved by 13% and 7%, respectively. Within the ROIs, our method also showed closer agreement with the ground truth, preserving the highly metabolic regions in the images. Significance. Our method represents a novel application of reconstruction techniques to delayed imaging, incorporating heterogeneous texture features from prior images for the first time. This approach significantly advances the field of medical image processing by improving the reconstruction quality of delayed PET images, providing clinicians with more reliable and detailed information for patient care. Clinically, the texture features in delayed imaging provide structural information that eliminates the need for CT attenuation correction during delayed PET scans, thereby reducing patient radiation exposure and minimizing the risks associated with repeated scanning.

  • Open Access

    Machine learning positioning algorithms for long semi-monolithic scintillator PET detectors

    by Samuel Mungai Kinyanjui, Zhonghua Kuang, Zheng Liu, Ning Ren, Yongfeng Yang

    Objective. In this work, machine learning positioning algorithms are developed to improve the spatial resolutions of the semi-monolithic scintillator detectors in both monolithic (y) and depth of interaction (z) directions. Approach. Two long semi-monolithic scintillator detectors consisting of 12 lutetium yttrium oxyorthosilicate (LYSO) slabs of 0.96 × 56 × 10 mm3 and 14 LYSO slabs of 0.81 × 56 × 10 mm3 were manufactured. The scintillator arrays were read out by a 4 × 16 silicon photomultiplier array. 27 × 5 (y, z) positions of each detector were irradiated via a collimated 22Na pencil beam. Extreme gradient boosting (XGBoost) machine learning model was used to predict the interaction positions for y and z. The genetic algorithm (GA) or particle swarm optimization (PSO) algorithm was used to optimize hyperparameters for the XGBoost model. The results of the machine learning positioning algorithms were compared to analytical positioning methods. Main results. The GA and PSO algorithms provided similar results. Compared to the analytical methods, the machine learning positioning methods improved both y and z spatial resolutions especially at both ends of the detectors. The average y spatial resolutions using the machine learning positioning methods were 0.92 ± 0.41 mm and 0.94 ± 0.44 mm as compared to those obtained with the squared center of gravity method of 1.38 ± 0.23 mm and 1.39 ± 0.25 mm for the two detectors, respectively. The average z spatial resolutions obtained with the machine learning positioning methods were 1.67 ± 0.41 mm and 1.68 ± 0.45 mm as compared to those obtained with inverse standard deviation method of 2.09 ± 0.82 mm and 2.14 ± 0.81 mm for the two detectors, respectively. Significance. With the machine learning positioning algorithms, the semi-monolithic scintillator detectors with submillimeter slab thickness evaluated in this work provide less than 1 mm y spatial resolution and less than 2 mm z spatial resolution.


  • Multistage Diffusion Model With Phase Error Correction for Fast PET Imaging

    by Yunlong Gao, Zhenxing Huang, Xingyu Xie, Wenjie Zhao, Qianyi Yang, Xinlan Yang, Yongfeng Yang, Hairong Zheng, Dong Liang, Jianjun Liu, et al.

    Fast PET imaging is clinically important for reducing motion artifacts and improving patient comfort. While recent diffusion-based deep learning methods have shown promise, they often fail to capture the true PET degradation process, suffer from accumulated inference errors, introduce artifacts, and require extensive reconstruction iterations. To address these challenges, we propose a novel multistage diffusion framework tailored for fast PET imaging. At the coarse level, we design a multistage structure to approximate the temporal non-linear PET degradation process in a data-driven manner, using paired PET images collected under different acquisition duration. A Phase Error Correction Network (PECNet) ensures consistency across stages by correcting accumulated deviations. At the fine level, we introduce a deterministic cold diffusion mechanism, which simulates intra-stage degradation through interpolation between known acquisition durations—significantly reducing reconstruction iterations to as few as 10. Evaluations on [68Ga]FAPI and [18F]FDG PET datasets demonstrate the superiority of our approach, achieving peak PSNRs of 36.2 dB and 39.0 dB, respectively, with average SSIMs over 0.97. Our framework offers high-fidelity PET imaging with fewer iterations, making it practical for accelerated clinical imaging.


  • Diffusion-Based Model for Parametric K i Generation From Total-Body Dynamic PET of Short-Duration Scan

    by Meiyuan Wen, Yaping Wu, Zhenxing Huang, Xiangjian He, Fiseha B. Tesema, Zixiang Chen, Yunlong Gao, Wenbo Li, Xinlan Yang, Yongfeng Yang, et al.

    Dynamic positron emission tomography (PET) parametric imaging typically requires a 60-minute acquisition period, causing patient discomfort and reducing clinical efficiency. This study explores the feasibility of generating parametric Ki images from 10-minute dynamic PET images acquired in the early or late scanning phases employing a multi-channel feature fusion cold sampling (MCFFCoS) framework. PET data from 103 patients are acquired using the uEXPLORER total-body PET/CT scanner during 60-minute scans. This study conducts deep learning experiments, taking early-phase or late-phase PET images as input, respectively. The generated Ki images are evaluated by visual quality and quantitative metrics, including root mean squared error (RMSE), structural similarity index (SSIM), and peak signal-to-noise ratio (PSNR). Volumes of interest (VOIs) analysis is performed using linear regression and Bland-Altman plots. In the quantitative evaluation of total-body data, the parametric Ki images generated from late-phase PET data generally outperform those derived from early-phase data. The analysis of VOIs indicates that the appropriate scanning protocol for PET parametric imaging may vary for different body regions. The deep learning approach is able to generate high-quality parametric Ki images from 10-minute dynamic PET scans, bypassing the requirements of long acquisition time for the estimation of blood input function in kinetic modeling.


  • Dual-Prompt-Enhanced Multiorgan Segmentation Model for Total-Body PET Images

    by Yunlong Gao, Zhenxing Huang, Yaping Wu, Wenbo Li, Meiyuan Wen, Wenjie Zhao, Qianyi Yang, Chuanli Cheng, Xinlan Yang, Yongfeng Yang, et al.

    Multi-organ segmentation in total-body PET images is crucial for accurately locating abnormalities and assisting in the observation of corresponding metabolic regions in the human body. Despite the emergence of numerous advanced methods in the field of multi-organ segmentation in recent years, available PET image segmentation techniques remain relatively limited. The complexity and variability of textures in PET images, the varying visibility and contrast of organs due to different metabolic activities, and the challenges posed by blurred organ boundaries in PET images all contribute to the increased difficulty of multi-organ segmentation. In this paper, we propose the Dual-Prompt Enhanced Multi-Organ Segmentation Model (DPESeg) for total-body PET image segmentation. Our approach focuses on enhancing the model’s ability to perceive organ thresholds and shapes by introducing textual and disentangled organ features, thereby improving segmentation accuracy. We validate our model on a dataset of total-body PET images obtained from 110 patients. Both visual and quantitative results demonstrate that DPESeg performs well in the multi-organ segmentation task, with a 2.02% improvement in the Dice coefficient and a 1.90% improvement in the Jaccard index compared to the best-performing comparison algorithm.