Beomjun Park
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Beomjun Park has a total of 117 co-authors. Here are the top co-authors by number of shared publications:
Jangwon Byun
8 shared publicationsJiwon Seo
8 shared publications- Jangwon Byun
Department of Chemistry Konkuk University Seoul Republic of Korea
7 shared publications - Jeongho Kim
Department of Research & Support, Samsung Changwon Hospital, Sungkyunkwan University School of Medicine, Changwon 51353, Republic of Korea
7 shared publications J. Seo
Interdisciplinary Program in Precision Public Health, Korea University, Seoul 02841, Republic of Korea
6 shared publications- Jiwon Seo
Korea Institute of Fusion Energy (KFE) Daejeon Republic of Korea
6 shared publications
Latest Publications
- Open Access
- 28 August 2026
- Published by Wiley in Small Methods
- Vol. 10 (18) , e71005
Halide‐Gradient Sidewall Heterojunctions for Lateral Charge Confinement in Perovskite Single Crystal x‐ray Detectors
Halide perovskite single crystals are promising active materials for direct x‐ray detectors because of their strong x‐ray absorption, efficient charge transport, and solution‐processable crystal growth. However, in thick single‐crystal detectors, lateral side surfaces can act as conductive leakage pathways, increasing dark current, inducing baseline drift, and generating transient overshoot and undershoot during x‐ray irradiation. Previous passivation and heterojunction strategies have mainly focused on metal–semiconductor interfaces, leaving side‐surface transport pathways insufficiently controlled. Here, a selective side‐surface ion‐exchange strategy is developed to construct halide‐gradient sidewall heterojunctions in MAPbBr 3 single crystals. Through methylammonium chloride‐induced ion exchange, compositionally graded MAPbBr 3 − x Cl x /MAPbBr 3 multi‐heterojunctions are formed along the crystal sidewalls, creating wide‐bandgap lateral barriers that confine charge carriers within the Br‐rich bulk region. Spatial conductivity mapping and current‐distribution simulations reveal that the graded sidewalls suppress edge‐dominated conductivity and homogenize vertical charge transport without requiring guard‐ring electrodes. Consequently, side‐surface leakage, baseline drift, and transient undershoot are strongly suppressed, yielding reproducible and distortion‐free x‐ray responses. The treated detectors exhibit a 4.7‐fold enhancement in sensitivity, a 2.85‐fold reduction in detection limit, and markedly improved low‐dose x‐ray imaging contrast. This work establishes sidewall‐selective halide‐gradient engineering as a scalable route for lateral charge confinement in perovskite single‐crystal radiation detectors.
- 28 August 2026
- Published by Wiley in Small Methods
- Vol. 10 (18) , e71005
Open AccessHalide‐Gradient Sidewall Heterojunctions for Lateral Charge Confinement in Perovskite Single Crystal x‐ray Detectors
Halide perovskite single crystals are promising active materials for direct x‐ray detectors because of their strong x‐ray absorption, efficient charge transport, and solution‐processable crystal growth. However, in thick single‐crystal detectors, lateral side surfaces can act as conductive leakage pathways, increasing dark current, inducing baseline drift, and generating transient overshoot and undershoot during x‐ray irradiation. Previous passivation and heterojunction strategies have mainly focused on metal–semiconductor interfaces, leaving side‐surface transport pathways insufficiently controlled. Here, a selective side‐surface ion‐exchange strategy is developed to construct halide‐gradient sidewall heterojunctions in MAPbBr 3 single crystals. Through methylammonium chloride‐induced ion exchange, compositionally graded MAPbBr 3 − x Cl x /MAPbBr 3 multi‐heterojunctions are formed along the crystal sidewalls, creating wide‐bandgap lateral barriers that confine charge carriers within the Br‐rich bulk region. Spatial conductivity mapping and current‐distribution simulations reveal that the graded sidewalls suppress edge‐dominated conductivity and homogenize vertical charge transport without requiring guard‐ring electrodes. Consequently, side‐surface leakage, baseline drift, and transient undershoot are strongly suppressed, yielding reproducible and distortion‐free x‐ray responses. The treated detectors exhibit a 4.7‐fold enhancement in sensitivity, a 2.85‐fold reduction in detection limit, and markedly improved low‐dose x‐ray imaging contrast. This work establishes sidewall‐selective halide‐gradient engineering as a scalable route for lateral charge confinement in perovskite single‐crystal radiation detectors.
- Open Access
- 24 August 2026
- Published by Wiley in Laser & Photonics Reviews
Zero‐Dimensional Perovskite‐Inspired Scintillator‐Based High‐Radiation‐Resistant Radionuclide Analyzer Free From Irreversible Degradation
Radiation detectors operating in extreme environments such as nuclear accident sites, radioactive waste facilities, space missions, and post‐detonation scenarios must maintain reliable radionuclide identification under prolonged high‐dose irradiation. However, radiation‐induced defect accumulation progressively degrades spectroscopic performance, and the mechanisms governing reversible detector operation under extreme irradiation remain not fully understood. Here, we report a zero‐dimensional perovskite‐inspired Cs 3 Cu 2 I 5 single‐crystal scintillator that exhibits fully reversible spectroscopic degradation under ultra‐high‐dose γ‐ray irradiation of ∼200 kGy. The radiation response was systematically investigated by correlating structural, optical, and spectroscopic analyses before and after mild thermal recovery. Structural and spectroscopic analyses reveal that irradiation induces predominantly interstitial‐type lattice disorder while preserving long‐range crystallinity and the intrinsic self‐trapped exciton emission framework. Despite reduced light output, the degraded spectroscopic performance is completely restored through mild thermal activation at 100°C without device refabrication. Under simultaneous six‐radionuclide γ‐ray fields, the scintillator maintains distinguishable spectral features and high post‐irradiation energy linearity (R 2 = 0.9973), outperforming conventional NaI(Tl) under comparable conditions. These findings highlight defect‐mediated reversibility as a promising design strategy for radiation‐resilient scintillators operating in extreme environments.
- 24 August 2026
- Published by Wiley in Laser & Photonics Reviews
Open AccessZero‐Dimensional Perovskite‐Inspired Scintillator‐Based High‐Radiation‐Resistant Radionuclide Analyzer Free From Irreversible Degradation
Radiation detectors operating in extreme environments such as nuclear accident sites, radioactive waste facilities, space missions, and post‐detonation scenarios must maintain reliable radionuclide identification under prolonged high‐dose irradiation. However, radiation‐induced defect accumulation progressively degrades spectroscopic performance, and the mechanisms governing reversible detector operation under extreme irradiation remain not fully understood. Here, we report a zero‐dimensional perovskite‐inspired Cs 3 Cu 2 I 5 single‐crystal scintillator that exhibits fully reversible spectroscopic degradation under ultra‐high‐dose γ‐ray irradiation of ∼200 kGy. The radiation response was systematically investigated by correlating structural, optical, and spectroscopic analyses before and after mild thermal recovery. Structural and spectroscopic analyses reveal that irradiation induces predominantly interstitial‐type lattice disorder while preserving long‐range crystallinity and the intrinsic self‐trapped exciton emission framework. Despite reduced light output, the degraded spectroscopic performance is completely restored through mild thermal activation at 100°C without device refabrication. Under simultaneous six‐radionuclide γ‐ray fields, the scintillator maintains distinguishable spectral features and high post‐irradiation energy linearity (R 2 = 0.9973), outperforming conventional NaI(Tl) under comparable conditions. These findings highlight defect‐mediated reversibility as a promising design strategy for radiation‐resilient scintillators operating in extreme environments.
- 9 July 2026
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 37 (9)
First performance results of a CdZnTeSe crystal for beta-ray spectroscopy of beta-emitting radioisotopes
- 9 July 2026
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 37 (9)
First performance results of a CdZnTeSe crystal for beta-ray spectroscopy of beta-emitting radioisotopes
- Open Access
- 25 June 2026
- Published by Wiley in Laser & Photonics Reviews
- Vol. 20 (17)
Discovering Shared Design Heritage for Semiconductor‐Based Gamma‐Ray Spectrometers: From CdTe to Metal Halide Perovskites
CdTe‐based compound semiconductors, particularly CdZnTe(CZT), have shaped the technological foundation of room‐temperature gamma‐ray spectrometers through continuous advances in crystal growth, defect control, and device engineering. While metal halide perovskites have recently emerged as promising direct‐conversion materials for gamma‐ray spectroscopy, their performance is consistently evaluated in reference to CZT detectors, reflecting a deeper continuity in device physics and architecture rather than a simple comparison of material properties. This Review examines the parallel evolution of CdTe‐derived and metal halide perovskite gamma‐spectrometers and identifies the shared physical and device‐level principles that underpin high‐resolution spectroscopy. We revisit the historical development of CdTe‐based detectors, highlighting how bandgap engineering, defect suppression, surface passivation, and contact design enabled spectroscopic‐grade operation at room temperature, and analyze how analogous challenges are addressed in perovskite gamma‐spectrometers to achieve intrinsic electrical states, suppress dark current, mitigate defect‐related instabilities, and improve their spectral performance. Across both material platforms, particular emphasis is placed on geometrical device engineering for weighting‐potential control, which emerges as a decisive factor in realizing high energy resolution beyond intrinsic material metrics alone. By consolidating these developments, this Review elucidates a shared design heritage in gamma‐ray spectroscopy technology and provides a rational framework for the development of next‐generation semiconductor‐based gamma‐spectrometers.
- 25 June 2026
- Published by Wiley in Laser & Photonics Reviews
- Vol. 20 (17)
Open AccessDiscovering Shared Design Heritage for Semiconductor‐Based Gamma‐Ray Spectrometers: From CdTe to Metal Halide Perovskites
CdTe‐based compound semiconductors, particularly CdZnTe(CZT), have shaped the technological foundation of room‐temperature gamma‐ray spectrometers through continuous advances in crystal growth, defect control, and device engineering. While metal halide perovskites have recently emerged as promising direct‐conversion materials for gamma‐ray spectroscopy, their performance is consistently evaluated in reference to CZT detectors, reflecting a deeper continuity in device physics and architecture rather than a simple comparison of material properties. This Review examines the parallel evolution of CdTe‐derived and metal halide perovskite gamma‐spectrometers and identifies the shared physical and device‐level principles that underpin high‐resolution spectroscopy. We revisit the historical development of CdTe‐based detectors, highlighting how bandgap engineering, defect suppression, surface passivation, and contact design enabled spectroscopic‐grade operation at room temperature, and analyze how analogous challenges are addressed in perovskite gamma‐spectrometers to achieve intrinsic electrical states, suppress dark current, mitigate defect‐related instabilities, and improve their spectral performance. Across both material platforms, particular emphasis is placed on geometrical device engineering for weighting‐potential control, which emerges as a decisive factor in realizing high energy resolution beyond intrinsic material metrics alone. By consolidating these developments, this Review elucidates a shared design heritage in gamma‐ray spectroscopy technology and provides a rational framework for the development of next‐generation semiconductor‐based gamma‐spectrometers.
- 21 April 2026
- Published by American Chemical Society (ACS) in ACS Applied Electronic Materials
- Vol. 8 (9) , 4075-4088
Interface-Engineered Ultrawide-Bandgap TiN/β-Ga 2 O 3 Schottky Diodes for Radiation-Hard X-ray Detection and Imaging
- 21 April 2026
- Published by American Chemical Society (ACS) in ACS Applied Electronic Materials
- Vol. 8 (9) , 4075-4088
Interface-Engineered Ultrawide-Bandgap TiN/β-Ga 2 O 3 Schottky Diodes for Radiation-Hard X-ray Detection and Imaging
- 11 March 2026
- Published by Wiley in Advanced Optical Materials
- Vol. 14 (12)
Metastable Zone Engineering With Excess Halide for Low‐Defect MAPbBr 3 Single Crystals with Ultra‐Low X‐Ray Detection Limit
MAPbBr 3 single crystals (MPB SCs) are promising materials for X‐ray detection; however, their use in low‐dose imaging is limited by high dark current, low detectability, and noise that degrades image clarity. Under X‐ray irradiation, where electron–hole pair generation is inherently low, suppressing defects is critical to minimize losses and maximize charge collection. In this study, metastable zone engineering is employed by tuning the MABr:PbBr 2 ratio during inverse temperature crystallization (ITC) to produce defect‐suppressed MPB SCs. Excess MABr broadens and stabilizes the metastable zone, reducing nucleation events and enabling the growth of large, high‐crystallinity MPB SCs exceeding 10 mm within 11 h. These crystals exhibit electronic properties closer to intrinsic behavior, with prolonged carrier lifetimes of 371 ns and an enhanced mobility‐lifetime ( µτ ) product of 3.43 × 10 −3 cm 2 V −1 . Photoluminescence spectra reveal a distinct secondary peak from photon recycling, with intensity 1.25 times greater than the band‐edge peak, indicating efficient photon reabsorption due to reduced non‐radiative losses. Devices fabricated from excess MPB SCs achieve a record‐low detection limit of 0.47 nGy s −1 , high sensitivity (6.117 × 10 3 µC Gy air −1 cm −2 ), and high‐resolution X‐ray imaging, demonstrating strong potential for advanced medical and industrial applications.
- 11 March 2026
- Published by Wiley in Advanced Optical Materials
- Vol. 14 (12)
Metastable Zone Engineering With Excess Halide for Low‐Defect MAPbBr 3 Single Crystals with Ultra‐Low X‐Ray Detection Limit
MAPbBr 3 single crystals (MPB SCs) are promising materials for X‐ray detection; however, their use in low‐dose imaging is limited by high dark current, low detectability, and noise that degrades image clarity. Under X‐ray irradiation, where electron–hole pair generation is inherently low, suppressing defects is critical to minimize losses and maximize charge collection. In this study, metastable zone engineering is employed by tuning the MABr:PbBr 2 ratio during inverse temperature crystallization (ITC) to produce defect‐suppressed MPB SCs. Excess MABr broadens and stabilizes the metastable zone, reducing nucleation events and enabling the growth of large, high‐crystallinity MPB SCs exceeding 10 mm within 11 h. These crystals exhibit electronic properties closer to intrinsic behavior, with prolonged carrier lifetimes of 371 ns and an enhanced mobility‐lifetime ( µτ ) product of 3.43 × 10 −3 cm 2 V −1 . Photoluminescence spectra reveal a distinct secondary peak from photon recycling, with intensity 1.25 times greater than the band‐edge peak, indicating efficient photon reabsorption due to reduced non‐radiative losses. Devices fabricated from excess MPB SCs achieve a record‐low detection limit of 0.47 nGy s −1 , high sensitivity (6.117 × 10 3 µC Gy air −1 cm −2 ), and high‐resolution X‐ray imaging, demonstrating strong potential for advanced medical and industrial applications.
- 20 January 2026
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 243
Quantification of ionic migration in TlBr gamma-ray detector via temperature-dependent conductivity measurements
- 20 January 2026
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 243
Quantification of ionic migration in TlBr gamma-ray detector via temperature-dependent conductivity measurements
- 1 January 2026
- Published by American Chemical Society (ACS) in ACS Applied Electronic Materials
- Vol. 8 (1) , 293-312
Dual-Functional Ni/4H-SiC Schottky Interfaces: Robust UV and X-ray Detection, Imaging in Extreme Environments
- 1 January 2026
- Published by American Chemical Society (ACS) in ACS Applied Electronic Materials
- Vol. 8 (1) , 293-312
Dual-Functional Ni/4H-SiC Schottky Interfaces: Robust UV and X-ray Detection, Imaging in Extreme Environments
- Open Access
- 31 July 2025
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 57 (12)
Wide dynamic range X-ray detector utilizing spectroscopic grade thallium bromide single crystal
- 31 July 2025
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 57 (12)
Open AccessWide dynamic range X-ray detector utilizing spectroscopic grade thallium bromide single crystal