Lu Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lu Chen has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Tianyi Wu
State Grid Shanghai Electric Power Research Institute, Shanghai 201199, China
2 shared publications - Adisu Makeyaw
School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China
1 shared publication - Bengang Wei
State Grid Shanghai Electric Power Research Institute, Shanghai 200437, China
1 shared publication - Chen Ren
State Grid Shanghai Electric Power Research Institute, Shanghai 200437, China
1 shared publication - Ke Liu
School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China
1 shared publication - Weiyun Mao
State Grid Shanghai Electric Power Research Institute, Shanghai 200437, China
1 shared publication
Latest Publications
- Open Access
Utility Transformer DC Bias Caused by Metro Stray Current—A Review
The rapid expansion of the urban rail network has increased concerns regarding stray current generated by the DC traction power supply system. This stray current, which arises from inadequate insulation between the rail and the ground, can cause electrochemical corrosion and operational challenges to nearby buried metallic infrastructures. A portion of stray current entering utility transformers may induce DC bias risk, thereby affecting the stability and reliability of distribution networks. This review studies the trends in utility transformer-related DC bias caused by metro stray current. Various modeling approaches and suppression measures are discussed, with an emphasis on comprehensively understanding stray current distribution behavior, the DC bias coupling loop, and its impacts. This review underscores the need for a thorough evaluation of existing DC bias suppression measures, and more effective and efficient measures must be developed to enhance the resilience of distribution networks. The gaps in current research are highlighted, and further studies are advocated, particularly those focusing on dynamic metro conditions, supported by advanced modeling, field applications, and interdisciplinary collaboration, to address the challenges of DC bias in urban rail environments.
Open AccessUtility Transformer DC Bias Caused by Metro Stray Current—A Review
The rapid expansion of the urban rail network has increased concerns regarding stray current generated by the DC traction power supply system. This stray current, which arises from inadequate insulation between the rail and the ground, can cause electrochemical corrosion and operational challenges to nearby buried metallic infrastructures. A portion of stray current entering utility transformers may induce DC bias risk, thereby affecting the stability and reliability of distribution networks. This review studies the trends in utility transformer-related DC bias caused by metro stray current. Various modeling approaches and suppression measures are discussed, with an emphasis on comprehensively understanding stray current distribution behavior, the DC bias coupling loop, and its impacts. This review underscores the need for a thorough evaluation of existing DC bias suppression measures, and more effective and efficient measures must be developed to enhance the resilience of distribution networks. The gaps in current research are highlighted, and further studies are advocated, particularly those focusing on dynamic metro conditions, supported by advanced modeling, field applications, and interdisciplinary collaboration, to address the challenges of DC bias in urban rail environments.
- Open Access
Fault Diagnosis for Power Transformers through Semi-Supervised Transfer Learning
The fault diagnosis of power transformers is a challenging problem. The massive multisource fault is heterogeneous, the type of fault is undetermined sometimes, and one device has only met a few kinds of faults in the past. We propose a fault diagnosis method based on deep neural networks and a semi-supervised transfer learning framework called adaptive reinforcement (AR) to solve the above limitations. The innovation of this framework consists of its enhancement of the consistency regularization algorithm. The experiments were conducted on real-world 110 kV power transformers’ three-phase fault grounding currents of the iron cores from various devices with four types of faults: Phases A, B, C and ABC to ground. We trained the model on the source domain and then transferred the model to the target domain, which included the unbalanced and undefined fault datasets. The results show that our proposed model reaches over accuracy in classifying the type of fault and outperforms other popular networks. Our AR framework fits target devices’ fault data with fewer dozen epochs than other novel semi-supervised techniques. Combining the deep neural network and the AR framework helps diagnose the power transformers, which lack diagnosis knowledge, with much less training time and reliable accuracy.Open AccessFault Diagnosis for Power Transformers through Semi-Supervised Transfer Learning
The fault diagnosis of power transformers is a challenging problem. The massive multisource fault is heterogeneous, the type of fault is undetermined sometimes, and one device has only met a few kinds of faults in the past. We propose a fault diagnosis method based on deep neural networks and a semi-supervised transfer learning framework called adaptive reinforcement (AR) to solve the above limitations. The innovation of this framework consists of its enhancement of the consistency regularization algorithm. The experiments were conducted on real-world 110 kV power transformers’ three-phase fault grounding currents of the iron cores from various devices with four types of faults: Phases A, B, C and ABC to ground. We trained the model on the source domain and then transferred the model to the target domain, which included the unbalanced and undefined fault datasets. The results show that our proposed model reaches over accuracy in classifying the type of fault and outperforms other popular networks. Our AR framework fits target devices’ fault data with fewer dozen epochs than other novel semi-supervised techniques. Combining the deep neural network and the AR framework helps diagnose the power transformers, which lack diagnosis knowledge, with much less training time and reliable accuracy.