Mohamed A. Elseify
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mohamed A. Elseify has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Salah Kamel
Department of Electrical Engineering, Faculty of Engineering, Aswan University, Aswan, Egypt
5 shared publications Salah Kamel
3 shared publicationsAhmed Refaat
Electrical Engineering Department, Port Said University Port Said, Port Said, 42524, Egypt
2 shared publications- Loai S. Nasrat
Department of Electrical Engineering, Faculty of Engineering, Aswan University, Aswan 81542, Egypt
2 shared publications Mamdouh K. Ahmed
Electrical Engineering Department, Al-Azhar University, Cairo, 11751, Egypt
2 shared publicationsMohamed H. Osman
Electrical Engineering Department, Al-Azhar University, Qena,83513, Egypt
2 shared publications
Latest Publications
- Open Access
- 15 October 2024
- Published by Wiley in Optimal Control Applications and Methods
- Vol. 46 (1) , 320-342
Comprehensive Optimization of PID Controller Parameters for DC Motor Speed Management Using a Modified Jellyfish Search Algorithm
The proportional integral derivative (PID) controller plays a crucial role in various industrial applications. However, conventional methods often fail to provide optimal parameter values. Therefore, this study proposes a novel version of the jellyfish search (JS) algorithm, the modified jellyfish search (mJS) algorithm, for optimally tuning PID controllers to regulate the speed of a direct current (DC) motor. The original JS algorithm is known for its nature‐inspired approach; however, it has limitations in terms of exploitation power. To address these issues, the proposed mJS incorporates quasi‐dynamic opposed‐based learning and a Weibull probability distribution. The objective function minimizes the integral of the time‐weighted absolute error (ITAE). The effectiveness of mJS was validated by solving the 23rd classical benchmark function, followed by a comparative analysis with contemporary optimization algorithms using stringent statistical criteria. Then mJS is then applied to optimize the PID parameters of three different DC motor models. Results show that the mJS outperforms the standard JS, gray wolf optimization (GWO), JAYA, and golden jackal optimization (GJO) for various performance indicators. Specifically, the best ITAE values were 3.274e6 for DC motor 1 using the JS algorithm, 0.002737 for DC motor 2 using the GJO algorithm, and 0.02785 for DC motor 3 using the mJS algorithm. Additionally, the mJS and JS algorithms reduced the settling time to 0.005 s for DC motor 1, whereas the best settling time of 0.325 s for DC motor 2 was achieved by the mJS algorithm, and a settling time of 1.19 s was recorded for DC motor 3 using both the mJS and JS algorithms. These findings underscore the practical importance of the developed optimizer in engineering applications and its significant contribution to the literature.
- 15 October 2024
- Published by Wiley in Optimal Control Applications and Methods
- Vol. 46 (1) , 320-342
Open AccessComprehensive Optimization of PID Controller Parameters for DC Motor Speed Management Using a Modified Jellyfish Search Algorithm
The proportional integral derivative (PID) controller plays a crucial role in various industrial applications. However, conventional methods often fail to provide optimal parameter values. Therefore, this study proposes a novel version of the jellyfish search (JS) algorithm, the modified jellyfish search (mJS) algorithm, for optimally tuning PID controllers to regulate the speed of a direct current (DC) motor. The original JS algorithm is known for its nature‐inspired approach; however, it has limitations in terms of exploitation power. To address these issues, the proposed mJS incorporates quasi‐dynamic opposed‐based learning and a Weibull probability distribution. The objective function minimizes the integral of the time‐weighted absolute error (ITAE). The effectiveness of mJS was validated by solving the 23rd classical benchmark function, followed by a comparative analysis with contemporary optimization algorithms using stringent statistical criteria. Then mJS is then applied to optimize the PID parameters of three different DC motor models. Results show that the mJS outperforms the standard JS, gray wolf optimization (GWO), JAYA, and golden jackal optimization (GJO) for various performance indicators. Specifically, the best ITAE values were 3.274e6 for DC motor 1 using the JS algorithm, 0.002737 for DC motor 2 using the GJO algorithm, and 0.02785 for DC motor 3 using the mJS algorithm. Additionally, the mJS and JS algorithms reduced the settling time to 0.005 s for DC motor 1, whereas the best settling time of 0.325 s for DC motor 2 was achieved by the mJS algorithm, and a settling time of 1.19 s was recorded for DC motor 3 using both the mJS and JS algorithms. These findings underscore the practical importance of the developed optimizer in engineering applications and its significant contribution to the literature.
- Open Access
- 1 August 2024
- Published by Springer Nature in Cluster Computing
- Vol. 27 (10) , 14767-14810
An improved moth flame optimization for optimal DG and battery energy storage allocation in distribution systems
Deploying distributed generators (DGs) powered by renewable energy poses a significant challenge for effective power system operation. Optimally scheduling DGs, especially photovoltaic (PV) systems and wind turbines (WTs), is critical because of the unpredictable nature of wind speed and solar radiation. These intermittencies have posed considerable challenges to power grids, including power oscillation, increased losses, and voltage instability. To overcome these challenges, the battery energy storage (BES) system supports the PV unit, while the biomass aids the WT unit, mitigating power fluctuations and boosting supply continuity. Therefore, the main innovation of this study is presenting an improved moth flame optimization algorithm (IMFO) to capture the optimal scheduling of multiple dispatchable and non-dispatchable DGs for mitigating energy loss in power grids, considering different dynamic load characteristics. The IMFO algorithm comprises a new update position expression based on a roulette wheel selection strategy as well as Gaussian barebones (GB) and quasi-opposite-based learning (QOBL) mechanisms to enhance exploitation capability, global convergence rate, and solution precision. The IMFO algorithm's success rate and effectiveness are evaluated using 23rd benchmark functions and compared with the basic MFO algorithm and other seven competitors using rigorous statistical analysis. The developed optimizer is then adopted to study the performance of the 69-bus and 118-bus distribution grids, considering deterministic and stochastic DG's optimal planning. The findings reflect the superiority of the developed algorithm against its rivals, emphasizing the influence of load types and varying generations in DG planning. Numerically, the optimal deployment of BES + PV and biomass + WT significantly maximizes the energy loss reduction percent to 68.3471 and 98.0449 for the 69-bus's commercial load type and to 54.833 and 52.0623 for the 118-bus's commercial load type, respectively, confirming the efficacy of the developed algorithm for maximizing the performance of distribution systems in diverse situations.
- 1 August 2024
- Published by Springer Nature in Cluster Computing
- Vol. 27 (10) , 14767-14810
Open AccessAn improved moth flame optimization for optimal DG and battery energy storage allocation in distribution systems
Deploying distributed generators (DGs) powered by renewable energy poses a significant challenge for effective power system operation. Optimally scheduling DGs, especially photovoltaic (PV) systems and wind turbines (WTs), is critical because of the unpredictable nature of wind speed and solar radiation. These intermittencies have posed considerable challenges to power grids, including power oscillation, increased losses, and voltage instability. To overcome these challenges, the battery energy storage (BES) system supports the PV unit, while the biomass aids the WT unit, mitigating power fluctuations and boosting supply continuity. Therefore, the main innovation of this study is presenting an improved moth flame optimization algorithm (IMFO) to capture the optimal scheduling of multiple dispatchable and non-dispatchable DGs for mitigating energy loss in power grids, considering different dynamic load characteristics. The IMFO algorithm comprises a new update position expression based on a roulette wheel selection strategy as well as Gaussian barebones (GB) and quasi-opposite-based learning (QOBL) mechanisms to enhance exploitation capability, global convergence rate, and solution precision. The IMFO algorithm's success rate and effectiveness are evaluated using 23rd benchmark functions and compared with the basic MFO algorithm and other seven competitors using rigorous statistical analysis. The developed optimizer is then adopted to study the performance of the 69-bus and 118-bus distribution grids, considering deterministic and stochastic DG's optimal planning. The findings reflect the superiority of the developed algorithm against its rivals, emphasizing the influence of load types and varying generations in DG planning. Numerically, the optimal deployment of BES + PV and biomass + WT significantly maximizes the energy loss reduction percent to 68.3471 and 98.0449 for the 69-bus's commercial load type and to 54.833 and 52.0623 for the 118-bus's commercial load type, respectively, confirming the efficacy of the developed algorithm for maximizing the performance of distribution systems in diverse situations.
- Open Access
- 8 February 2023
- Published by Springer Nature in Neural Computing and Applications
- Vol. 35 (16) , 11867-11899
Multi-objective optimal allocation of multiple capacitors and distributed generators considering different load models using Lichtenberg and thermal exchange optimization techniques
Integrating distributed generations (DGs) into the radial distribution system (RDS) are becoming more crucial to capture the benefits of these DGs. However, the non-optimal integration of renewable DGs and shunt capacitors may lead to several operational challenges in distribution systems, including high energy losses, poor voltage quality, reverse power flow, and lower voltage stability. Therefore, in this paper, the multi-objective optimization problem is expressed with precisely selected three conflicting goals, incorporating the reduction in both power loss and voltage deviation and improvement of voltage stability. A new index for voltage deviation called root mean square voltage is suggested. The proposed multi-objective problems are addressed using two freshly metaheuristic techniques for optimal sitting and sizing multiple SCs and renewable DGs with unity and optimally power factors into RDS, presuming several voltage-dependent load models. These optimization techniques are the multi-objective thermal exchange optimization (MOTEO) and the multi-objective Lichtenberg algorithm (MOLA), which are regarded as being physics-inspired techniques. The MOLA is inspired by the physical phenomena of lightning storms and Lichtenberg figures (LF), while the MOTEO is developed based on the concept of Newtonian cooling law. The MOLA as a hybrid algorithm differs from many in the literature since it combines the population and trajectory-based search approaches. Further, the developed methodology is implemented on the IEEE 69-bus distribution network during several optimization scenarios, such as bi- and tri-objective problems. The fetched simulation outcomes confirmed the superiority of the MOTEO algorithm in achieving accurate non-dominated solutions with fewer outliers and standard deviation among all studied metrics.
- 8 February 2023
- Published by Springer Nature in Neural Computing and Applications
- Vol. 35 (16) , 11867-11899
Open AccessMulti-objective optimal allocation of multiple capacitors and distributed generators considering different load models using Lichtenberg and thermal exchange optimization techniques
Integrating distributed generations (DGs) into the radial distribution system (RDS) are becoming more crucial to capture the benefits of these DGs. However, the non-optimal integration of renewable DGs and shunt capacitors may lead to several operational challenges in distribution systems, including high energy losses, poor voltage quality, reverse power flow, and lower voltage stability. Therefore, in this paper, the multi-objective optimization problem is expressed with precisely selected three conflicting goals, incorporating the reduction in both power loss and voltage deviation and improvement of voltage stability. A new index for voltage deviation called root mean square voltage is suggested. The proposed multi-objective problems are addressed using two freshly metaheuristic techniques for optimal sitting and sizing multiple SCs and renewable DGs with unity and optimally power factors into RDS, presuming several voltage-dependent load models. These optimization techniques are the multi-objective thermal exchange optimization (MOTEO) and the multi-objective Lichtenberg algorithm (MOLA), which are regarded as being physics-inspired techniques. The MOLA is inspired by the physical phenomena of lightning storms and Lichtenberg figures (LF), while the MOTEO is developed based on the concept of Newtonian cooling law. The MOLA as a hybrid algorithm differs from many in the literature since it combines the population and trajectory-based search approaches. Further, the developed methodology is implemented on the IEEE 69-bus distribution network during several optimization scenarios, such as bi- and tri-objective problems. The fetched simulation outcomes confirmed the superiority of the MOTEO algorithm in achieving accurate non-dominated solutions with fewer outliers and standard deviation among all studied metrics.
- Open Access
- 15 June 2022
- Published by MDPI AG in Mathematics
- Vol. 10 (12) , 2081
A Novel Approach Based on Honey Badger Algorithm for Optimal Allocation of Multiple DG and Capacitor in Radial Distribution Networks Considering Power Loss Sensitivity
Recently, the integration of distributed generators (DGs) in radial distribution systems (RDS) has been widely evolving due to its sustainability and lack of pollution. This study presents an efficient optimization technique named the honey badger algorithm (HBA) for specifying the optimum size and location of capacitors and different types of DGs to minimize the total active power loss of the network. The Combined Power Loss Sensitivity (CPLS) factor is deployed with the HBA to accelerate the estimation process by specifying the candidate buses for optimal placement of DGs and capacitors in RDS. The performance of the optimization algorithm is demonstrated through the application to the IEEE 69-bus standard RDS with different scenarios: DG Type-I, DG Type-III, and capacitor banks (CBs). Furthermore, the effects of simultaneously integrating single and multiple DG Type-I with DG Type-III are illustrated. The results obtained revealed the effectiveness of the HBA for optimizing the size and location of single and multiple DGs and CBs with a considerable decline in the system’s real power losses. Additionally, the results have been compared with those obtained by other known algorithms.
- 15 June 2022
- Published by MDPI AG in Mathematics
- Vol. 10 (12) , 2081
Open AccessA Novel Approach Based on Honey Badger Algorithm for Optimal Allocation of Multiple DG and Capacitor in Radial Distribution Networks Considering Power Loss Sensitivity
Recently, the integration of distributed generators (DGs) in radial distribution systems (RDS) has been widely evolving due to its sustainability and lack of pollution. This study presents an efficient optimization technique named the honey badger algorithm (HBA) for specifying the optimum size and location of capacitors and different types of DGs to minimize the total active power loss of the network. The Combined Power Loss Sensitivity (CPLS) factor is deployed with the HBA to accelerate the estimation process by specifying the candidate buses for optimal placement of DGs and capacitors in RDS. The performance of the optimization algorithm is demonstrated through the application to the IEEE 69-bus standard RDS with different scenarios: DG Type-I, DG Type-III, and capacitor banks (CBs). Furthermore, the effects of simultaneously integrating single and multiple DG Type-I with DG Type-III are illustrated. The results obtained revealed the effectiveness of the HBA for optimizing the size and location of single and multiple DGs and CBs with a considerable decline in the system’s real power losses. Additionally, the results have been compared with those obtained by other known algorithms.
- 1 January 2022
- Published by International Journal of Renewable Energy Research in International Journal of Renewable Energy Research
- Vol. 12 (Vol12No1) , 208-217
Highly Efficient MPP Tracker based on Adaptive Neuro-fuzzy Inference System for Stand-Alone Photovoltaic Generator System
Recently, AI-based maximum power point tracking (MPPT) controllers for photovoltaic (PV) generator systems have become widespread. Compared to traditional maximum power point (MPP) trackers, the AI-based trackers have lower oscillations around the MPP, high tracking speed, and the least calculation time. Among the various AI methods, the Adaptive Neural Fuzzy Inference System (ANFIS) is widely used for PV systems. Nevertheless, obtaining precise training data and tuning the ANFIS model presents significant difficulties for developing an effective ANFIS-MPPT technique. This article proposes a highly efficient MPP tracker based on adaptive ANFIS with direct control for stand-alone PV generators. The proposed ANFIS-MPPT technique can trace the MPP under rapidly changing solar radiation and cell temperatures. The duty cycle of the boost converter is directly adjusted; hence the PI control loop is eliminated in this technique. The training data for the suggested technique are extracted with the aid of a multi-variable step perturbation and observation (MV-P&O-MPPT) algorithm for avoiding the errors that are usually included in an experimental dataset. The proposed ANFIS-MPPT technique is simulated and compared to other AI-based MPPT techniques such as Artificial Neural Networks (ANN) and Fuzzy Logic Controller (FLC). Simulation results confirm that the presented technique precisely tracks the MPP and achieves higher efficiency under different climatic conditions.
- 1 January 2022
- Published by International Journal of Renewable Energy Research in International Journal of Renewable Energy Research
- Vol. 12 (Vol12No1) , 208-217
Highly Efficient MPP Tracker based on Adaptive Neuro-fuzzy Inference System for Stand-Alone Photovoltaic Generator System
Recently, AI-based maximum power point tracking (MPPT) controllers for photovoltaic (PV) generator systems have become widespread. Compared to traditional maximum power point (MPP) trackers, the AI-based trackers have lower oscillations around the MPP, high tracking speed, and the least calculation time. Among the various AI methods, the Adaptive Neural Fuzzy Inference System (ANFIS) is widely used for PV systems. Nevertheless, obtaining precise training data and tuning the ANFIS model presents significant difficulties for developing an effective ANFIS-MPPT technique. This article proposes a highly efficient MPP tracker based on adaptive ANFIS with direct control for stand-alone PV generators. The proposed ANFIS-MPPT technique can trace the MPP under rapidly changing solar radiation and cell temperatures. The duty cycle of the boost converter is directly adjusted; hence the PI control loop is eliminated in this technique. The training data for the suggested technique are extracted with the aid of a multi-variable step perturbation and observation (MV-P&O-MPPT) algorithm for avoiding the errors that are usually included in an experimental dataset. The proposed ANFIS-MPPT technique is simulated and compared to other AI-based MPPT techniques such as Artificial Neural Networks (ANN) and Fuzzy Logic Controller (FLC). Simulation results confirm that the presented technique precisely tracks the MPP and achieves higher efficiency under different climatic conditions.