CWChunyan Wang

Chunyan Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chunyan Wang has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Novel Hybrid Brain-Computer Interface Combining Motor Imagery and Intermodulation Steady-State Visual Evoked Potential

    by Xinyi Chi, Chunxiao Wan, Chunyan Wang, Yong Zhang, Xiaogang Chen, Hongyan Cui

    The hybrid brain-computer interface (hBCI) combining motor imagery (MI) and steady-state visual evoked potential (SSVEP) has been proven to have better performance than a pure MI- or SSVEP-based brain-computer interface (BCI). In most studies on hBCIs, subjects have been required to focus their attention on flickering light-emitting diodes (LEDs) or blocks while imagining body movements. However, these two classical tasks performed concurrently have a poor correlation. Therefore, it is necessary to reduce the task complexity of such a system and improve its user-friendliness. Aiming to achieve this goal, this study proposes a novel hybrid BCI that combines MI and intermodulation SSVEPs. In the proposed system, images of both hands flicker at the same frequency (i.e., 30 Hz) but at different grasp frequencies (i.e., 1 Hz for the left hand, and 1.5 Hz for the right hand), resulting in different intermodulation frequencies for encoding targets. Additionally, movement observation for subjects can help to perform the MI task better. In this study, two types of brain signals are classified independently and then fused by a scoring mechanism based on the probability distribution of relevant parameters. The online verification results showed that the average accuracies of 12 healthy subjects and 11 stroke patients were 92.40 ± 7.45% and 73.07 ± 9.07%, respectively. The average accuracies of 10 healthy subjects in the MI, SSVEP, and hybrid tasks were 84.00 ± 12.81%, 80.75 ± 8.08%, and 89.00 ± 9.94%, respectively. The high recognition accuracy verifies the feasibility and robustness of the proposed system. This study provides a novel and natural paradigm for a hybrid BCI based on MI and SSVEP.


  • Open Access

    A Performance-Consistent and Computation-Efficient CNN System for High-Quality Automated Brain Tumor Segmentation

    by Juncheng Tong, Chunyan Wang

    The research on developing CNN-based fully-automated Brain-Tumor-Segmentation systems has been progressed rapidly. For the systems to be applicable in practice, a good The research on developing CNN-based fully-automated Brain-Tumor-Segmentation systems has been progressed rapidly. For the systems to be applicable in practice, a good processing quality and reliability are the must. Moreover, for wide applications of such systems, a minimization of computation complexity is desirable, which can also result in a minimization of randomness in computation and, consequently, a better performance consistency. To this end, the CNN in the proposed system has a unique structure with 2 distinguished characters. Firstly, the three paths of its feature extraction block are designed to extract, from the multi-modality input, comprehensive feature information of mono-modality, paired-modality and cross-modality data, respectively. Also, it has a particular three-branch classification block to identify the pixels of 4 classes. Each branch is trained separately so that the parameters are updated specifically with the corresponding ground truth data of a target tumor areas. The convolution layers of the system are custom-designed with specific purposes, resulting in a very simple config of 61,843 parameters in total. The proposed system is tested extensively with BraTS2018 and BraTS2019 datasets. The mean Dice scores, obtained from the ten experiments on BraTS2018 validation samples, are 0.787+0.003, 0.886+0.002, 0.801+0.007, for enhancing tumor, whole tumor and tumor core, respectively, and 0.751+0.007, 0.885+0.002, 0.776+0.004 on BraTS2019. The test results demonstrate that the proposed system is able to perform high-quality segmentation in a consistent manner. Furthermore, its extremely low computation complexity will facilitate its implementation/application in various environments.