Yue Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yue Wang has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
Ruijie Sun
Department of Medical Ultrasound, Peking University Shenzhen Hospital, Shenzhen Peking University - The Hong Kong University of Science and Technology Medical Center, Shenzhen, 518036, P.R. China
2 shared publicationsDesheng Sun
Department of Ultrasonography, Peking University Shenzhen hospital, Shenzhen, Guangdong Province, China
1 shared publication- Desheng Sun
Department of Ultrasound, Peking University Shenzhen Hospital, Shenzhen Peking University-The Hong Kong University of Science and Technology Medical Center, Shenzhen 518036, China
1 shared publication Fengbei Kong
Department of Medical Ultrasound, Peking University Shenzhen Hospital, Shenzhen Peking University - The Hong Kong University of Science and Technology Medical Center, Shenzhen, 518036, P.R. China
1 shared publication- Fengbei Kong
Department of Ultrasonography, Peking University Shenzhen hospital, Shenzhen, Guangdong Province, China
1 shared publication - Guoru Wu
Department of Ultrasonography, Peking University Shenzhen hospital, Shenzhen, Guangdong Province, China
1 shared publication
Latest Publications
- Open Access
- 6 September 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (17) , 2864
Transrectal Biplane Ultrasound Combined with Cotton Swab Marking of the External Urethral Orifice for Evaluating the Postoperative Position of Transobturator Mid-Urethral Sling: A Study on Standardized Ultrasound Measurement and Inter-Observer Reliability
Objectives: To assess the technical feasibility and interobserver reliability of transrectal biplane ultrasound with external cotton-swab marking of the urethral orifice after transobturator mid-urethral sling surgery, and secondarily to describe dynamic measurements and exploratory associations with chart-derived postoperative leakage. Methods: In this single-center retrospective cross-sectional imaging study, 112 consecutive women examined between January 2024 and February 2026 underwent a standardized protocol. The swab tip was placed lightly against, but not inserted into, the external urethral orifice. Sling width (W), distance from the sling upper edge to the internal urethral orifice (D-I), and distance from the sling lower edge to the external urethral orifice at rest (D-O) and during Valsalva (V-D-O) were measured. Forty randomly selected examinations were independently measured by two blinded readers. Agreement was evaluated using ICC(2,1), Bland–Altman bias and 95% limits of agreement (LoA), standard error of measurement (SEM), and minimal detectable change (MDC95). Missingness patterns and age-adjusted exploratory logistic models were examined. Results: W, D-I and D-O were measurable in all 112 women; V-D-O was available in 95 (84.8%). Postoperative leakage status was available in 101 women (62 without and 39 with leakage). V-D-O was shorter than D-O in paired examinations (median difference, −3.00 mm; 95% CI, −4.90 to −1.00; p < 0.001). ICCs were 0.845 for W, 0.942 for D-I, 0.936 for D-O and 0.970 for V-D-O. Bland–Altman biases (reader A minus reader B) were −0.18, −0.93, 0.70 and −0.23 mm, respectively; corresponding MDC95 values were 1.53, 2.96, 3.72 and 2.33 mm. Missing V-D-O was associated with a shorter postoperative interval after Holm correction. None of six age-adjusted ultrasound models was associated with chart-derived leakage after Holm correction. Conclusions: The protocol permitted highly available static measurements and good-to-excellent interobserver reliability. Because the study lacked an unmarked comparator, intraobserver repeats and a standardized clinical endpoint, it supports technical feasibility and measurement reliability, not superiority, diagnostic validity or prognostic utility.
- 6 September 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (17) , 2864
Open AccessTransrectal Biplane Ultrasound Combined with Cotton Swab Marking of the External Urethral Orifice for Evaluating the Postoperative Position of Transobturator Mid-Urethral Sling: A Study on Standardized Ultrasound Measurement and Inter-Observer Reliability
Objectives: To assess the technical feasibility and interobserver reliability of transrectal biplane ultrasound with external cotton-swab marking of the urethral orifice after transobturator mid-urethral sling surgery, and secondarily to describe dynamic measurements and exploratory associations with chart-derived postoperative leakage. Methods: In this single-center retrospective cross-sectional imaging study, 112 consecutive women examined between January 2024 and February 2026 underwent a standardized protocol. The swab tip was placed lightly against, but not inserted into, the external urethral orifice. Sling width (W), distance from the sling upper edge to the internal urethral orifice (D-I), and distance from the sling lower edge to the external urethral orifice at rest (D-O) and during Valsalva (V-D-O) were measured. Forty randomly selected examinations were independently measured by two blinded readers. Agreement was evaluated using ICC(2,1), Bland–Altman bias and 95% limits of agreement (LoA), standard error of measurement (SEM), and minimal detectable change (MDC95). Missingness patterns and age-adjusted exploratory logistic models were examined. Results: W, D-I and D-O were measurable in all 112 women; V-D-O was available in 95 (84.8%). Postoperative leakage status was available in 101 women (62 without and 39 with leakage). V-D-O was shorter than D-O in paired examinations (median difference, −3.00 mm; 95% CI, −4.90 to −1.00; p < 0.001). ICCs were 0.845 for W, 0.942 for D-I, 0.936 for D-O and 0.970 for V-D-O. Bland–Altman biases (reader A minus reader B) were −0.18, −0.93, 0.70 and −0.23 mm, respectively; corresponding MDC95 values were 1.53, 2.96, 3.72 and 2.33 mm. Missing V-D-O was associated with a shorter postoperative interval after Holm correction. None of six age-adjusted ultrasound models was associated with chart-derived leakage after Holm correction. Conclusions: The protocol permitted highly available static measurements and good-to-excellent interobserver reliability. Because the study lacked an unmarked comparator, intraobserver repeats and a standardized clinical endpoint, it supports technical feasibility and measurement reliability, not superiority, diagnostic validity or prognostic utility.
- Open Access
- 3 July 2026
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 26 (1)
Uterine cystic adenomyoma arising from cesarean scar diverticulum: a case report and literature review
With the rising rate of cesarean section delivery worldwide, the development of cesarean scar diverticulum (CSD) is increasingly observed, with a prevenance ranging from 24% to 70%. CSD is associated with abnormal uterine bleeding, chronic pelvic pain, cesarean scar pregnancy, and infertility. Furthermore, a CSD can present as a pelvic mass that causes diagnostic dilemma. Herein, we report a rare case of uterine cystic adenomyoma (UCA) arising from CSD and review a series of similar diseases to improve the understanding of CSD-associated mass. A 37-year-old woman presented with menorrhagia after her two cesarean deliveries. Transvaginal sonography (TVS) revealed a huge, thick-wall, heterogeneously hypoechoic mass at the anterior lower uterine segment, which was connected to uterine cavity and protruded outside of the uterus. No specific ultrasound diagnosis was made although it was in favor of benign lesion from prior cesarean scar. Hysteroscopic and laparoscopic exploration was decided. The operation verified a CSD at previous cesarean scar. Postoperative pathology revealed a CSD, uterine cystic adenomyoma (UCA), and diffuse smooth muscular hyperplasia, in favor of the diagnosis of CSD accompanied by UCA. The patient's menstrual condition improved after surgery. CSD-associated mass is very rare. In patients with a prior cesarean section, a mass in the lower uterine segment, especially with a cavity connection, should raise suspicion for a CSD-associated lesion. When TVS is inclusive, pelvic MRI serves as a diagnostic adjunct. For management, the combined hysteroscopic-laparoscopic approach allows for precise excision of the mass and concurrent repair of the CSD in a single procedure. Future efforts should focus on refining the classification of these masses and standardizing management procedures to optimize symptomatic and reproductive outcomes.
- 3 July 2026
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 26 (1)
Open AccessUterine cystic adenomyoma arising from cesarean scar diverticulum: a case report and literature review
With the rising rate of cesarean section delivery worldwide, the development of cesarean scar diverticulum (CSD) is increasingly observed, with a prevenance ranging from 24% to 70%. CSD is associated with abnormal uterine bleeding, chronic pelvic pain, cesarean scar pregnancy, and infertility. Furthermore, a CSD can present as a pelvic mass that causes diagnostic dilemma. Herein, we report a rare case of uterine cystic adenomyoma (UCA) arising from CSD and review a series of similar diseases to improve the understanding of CSD-associated mass. A 37-year-old woman presented with menorrhagia after her two cesarean deliveries. Transvaginal sonography (TVS) revealed a huge, thick-wall, heterogeneously hypoechoic mass at the anterior lower uterine segment, which was connected to uterine cavity and protruded outside of the uterus. No specific ultrasound diagnosis was made although it was in favor of benign lesion from prior cesarean scar. Hysteroscopic and laparoscopic exploration was decided. The operation verified a CSD at previous cesarean scar. Postoperative pathology revealed a CSD, uterine cystic adenomyoma (UCA), and diffuse smooth muscular hyperplasia, in favor of the diagnosis of CSD accompanied by UCA. The patient's menstrual condition improved after surgery. CSD-associated mass is very rare. In patients with a prior cesarean section, a mass in the lower uterine segment, especially with a cavity connection, should raise suspicion for a CSD-associated lesion. When TVS is inclusive, pelvic MRI serves as a diagnostic adjunct. For management, the combined hysteroscopic-laparoscopic approach allows for precise excision of the mass and concurrent repair of the CSD in a single procedure. Future efforts should focus on refining the classification of these masses and standardizing management procedures to optimize symptomatic and reproductive outcomes.
- Open Access
- 9 June 2026
- Published by Springer Nature in Middle East Fertility Society Journal
- Vol. 31 (1) , 53
Comparison of two ultrasound-based scoring systems for predicting pregnancy outcomes in IVF-embryo transfer patients
Objective: Endometrial receptivity is a critical determinant of embryo implantation and successful pregnancy in in vitro fertilization–embryo transfer (IVF-ET). Although ultrasound-based scoring systems have been proposed to improve its assessment, their predictive performance remains unclear. This study aimed to evaluate the diagnostic value of the Applebaum scoring system and its modified version in predicting clinical pregnancy outcomes. Methods: This retrospective study included 341 patients undergoing IVF-ET. Transvaginal ultrasound was performed on the day of embryo transfer, and endometrial receptivity was assessed using the Applebaum scoring system (A) and a modified version (B). Clinical pregnancy, defined as the presence of a gestational sac with fetal cardiac activity, was evaluated 35 days after embryo transfer. Receiver operating characteristic (ROC) curve analysis was used to assess predictive performance. Results: No statistically significant differences were observed in scores between the pregnancy and non-pregnancy groups for either scoring system ( P > 0.05). ROC analysis demonstrated poor discriminatory performance, with area under the curve (AUC) values of 0.54 (95% CI: 0.47–0.60) for system A and 0.56 (95% CI: 0.50–0.63) for system B. Conclusions: Both scoring systems showed poor predictive performance, with AUC values close to 0.5. These findings suggest limited clinical utility, and ultrasound-based scoring systems should not be used as standalone predictors of IVF outcomes.
- 9 June 2026
- Published by Springer Nature in Middle East Fertility Society Journal
- Vol. 31 (1) , 53
Open AccessComparison of two ultrasound-based scoring systems for predicting pregnancy outcomes in IVF-embryo transfer patients
Objective: Endometrial receptivity is a critical determinant of embryo implantation and successful pregnancy in in vitro fertilization–embryo transfer (IVF-ET). Although ultrasound-based scoring systems have been proposed to improve its assessment, their predictive performance remains unclear. This study aimed to evaluate the diagnostic value of the Applebaum scoring system and its modified version in predicting clinical pregnancy outcomes. Methods: This retrospective study included 341 patients undergoing IVF-ET. Transvaginal ultrasound was performed on the day of embryo transfer, and endometrial receptivity was assessed using the Applebaum scoring system (A) and a modified version (B). Clinical pregnancy, defined as the presence of a gestational sac with fetal cardiac activity, was evaluated 35 days after embryo transfer. Receiver operating characteristic (ROC) curve analysis was used to assess predictive performance. Results: No statistically significant differences were observed in scores between the pregnancy and non-pregnancy groups for either scoring system ( P > 0.05). ROC analysis demonstrated poor discriminatory performance, with area under the curve (AUC) values of 0.54 (95% CI: 0.47–0.60) for system A and 0.56 (95% CI: 0.50–0.63) for system B. Conclusions: Both scoring systems showed poor predictive performance, with AUC values close to 0.5. These findings suggest limited clinical utility, and ultrasound-based scoring systems should not be used as standalone predictors of IVF outcomes.
- 19 March 2026
- Published by Springer Nature in Journal of Ultrasound
- Vol. 29 (2) , 337-345
Feasibility study of transvaginal biplanar convex ultrasound for evaluating levator ani muscle
Objective To investigate the clinical feasibility and value of transvaginal biplanar convex ultrasound for evaluating the levator ani muscle (LAM). Methods This prospective cross-sectional study enrolled 130 Chinese women undergoing pelvic floor ultrasound examinations. One doctor (operator 1) performed transperineal three-dimensional ultrasound for tomographic ultrasound imaging (TUI) of the LAM. Concurrently, transvaginal biplanar convex ultrasound was used to assess LAM continuity and thickness, measuring the thickness of the attachment and middle portions and the anal canal level. Seven days later, the same doctor (operator 1) and another doctor (operator 2) repeated the LAM thickness measurements. Cohen’s kappa coefficient and intraclass correlation coefficients (ICCs) were calculated to analyze the results. Results Transvaginal biplanar convex ultrasound demonstrated excellent consistency with TUI for diagnosing LAM avulsion (Cohen’s kappa = 0.74, 95% CI 0.50–0.98). Thickness measurements of each specified segment exhibited excellent intraobserver and good interobserver repeatability (ICC = 0.82–0.86 and 0.74–0.77, respectively). Bland–Altman analysis indicated good consistency between the two operators’ measurements. Conclusions Transvaginal biplanar convex ultrasound is a simple, reliable imaging screening method for LAM evaluation.
- 19 March 2026
- Published by Springer Nature in Journal of Ultrasound
- Vol. 29 (2) , 337-345
Feasibility study of transvaginal biplanar convex ultrasound for evaluating levator ani muscle
Objective To investigate the clinical feasibility and value of transvaginal biplanar convex ultrasound for evaluating the levator ani muscle (LAM). Methods This prospective cross-sectional study enrolled 130 Chinese women undergoing pelvic floor ultrasound examinations. One doctor (operator 1) performed transperineal three-dimensional ultrasound for tomographic ultrasound imaging (TUI) of the LAM. Concurrently, transvaginal biplanar convex ultrasound was used to assess LAM continuity and thickness, measuring the thickness of the attachment and middle portions and the anal canal level. Seven days later, the same doctor (operator 1) and another doctor (operator 2) repeated the LAM thickness measurements. Cohen’s kappa coefficient and intraclass correlation coefficients (ICCs) were calculated to analyze the results. Results Transvaginal biplanar convex ultrasound demonstrated excellent consistency with TUI for diagnosing LAM avulsion (Cohen’s kappa = 0.74, 95% CI 0.50–0.98). Thickness measurements of each specified segment exhibited excellent intraobserver and good interobserver repeatability (ICC = 0.82–0.86 and 0.74–0.77, respectively). Bland–Altman analysis indicated good consistency between the two operators’ measurements. Conclusions Transvaginal biplanar convex ultrasound is a simple, reliable imaging screening method for LAM evaluation.
- Open Access
- 12 December 2025
- Published by Wolters Kluwer Health in Medicine
- Vol. 104 (50) , e46533
Prenatal sonographic diagnosis of pseudomonoamniotic twins: Two-case series
Rationale: Pseudomonoamniotic twins (PMA), a rare and high-risk complication of diamniotic twins, result from the rupture of the dividing membrane. This condition is associated with fetal malformations and demise. Current prenatal ultrasound detection rates remain suboptimal, with most cases diagnosed only after umbilical cord entanglement or intrauterine fetal death. Here, we present 2 cases of PMA diagnosed prenatally via ultrasound and focus on discussing their sonographic features. Patient concerns: Case 1: No first-trimester ultrasound was performed in this case. The patient visited our hospital for the first ultrasound examination at 12weeks’ gestation. Case 2: Follow-up ultrasound was performed 1 day after amniocentesis at 26 weeks’ gestation. Diagnoses: Case 1: PMA with amniotic band syndrome. Case 2: PMA with cord entanglement and fetal distress. Interventions: Case 1: The twins did not receive any specific treatment. Case 2: Emergency cesarean delivery was performed. Outcomes: Case 1: Induction of labor at 13 weeks’ gestation. Case 2: Preterm twins admitted to neonatal intensive care unit, discharged after 50 days with favorable outcomes. Lessons: Targeted evaluation of the dividing membrane at the umbilical cord insertion sites may improve the detection of spontaneous PMA. Sonographic manifestations of dividing-membrane rupture include the multilayer folding sign, absence of the dividing membrane, 1 fetus entering the amniotic sac of the co-twin, and umbilical cord entanglement. The multilayer folding sign may be an early indicator of the rupture dividing membrane. Complications resulting from dividing-membrane rupture warrant heightened vigilance, especially amniotic band syndrome and cord entanglement, both of which are associated with adverse perinatal outcomes.
- 12 December 2025
- Published by Wolters Kluwer Health in Medicine
- Vol. 104 (50) , e46533
Open AccessPrenatal sonographic diagnosis of pseudomonoamniotic twins: Two-case series
Rationale: Pseudomonoamniotic twins (PMA), a rare and high-risk complication of diamniotic twins, result from the rupture of the dividing membrane. This condition is associated with fetal malformations and demise. Current prenatal ultrasound detection rates remain suboptimal, with most cases diagnosed only after umbilical cord entanglement or intrauterine fetal death. Here, we present 2 cases of PMA diagnosed prenatally via ultrasound and focus on discussing their sonographic features. Patient concerns: Case 1: No first-trimester ultrasound was performed in this case. The patient visited our hospital for the first ultrasound examination at 12weeks’ gestation. Case 2: Follow-up ultrasound was performed 1 day after amniocentesis at 26 weeks’ gestation. Diagnoses: Case 1: PMA with amniotic band syndrome. Case 2: PMA with cord entanglement and fetal distress. Interventions: Case 1: The twins did not receive any specific treatment. Case 2: Emergency cesarean delivery was performed. Outcomes: Case 1: Induction of labor at 13 weeks’ gestation. Case 2: Preterm twins admitted to neonatal intensive care unit, discharged after 50 days with favorable outcomes. Lessons: Targeted evaluation of the dividing membrane at the umbilical cord insertion sites may improve the detection of spontaneous PMA. Sonographic manifestations of dividing-membrane rupture include the multilayer folding sign, absence of the dividing membrane, 1 fetus entering the amniotic sac of the co-twin, and umbilical cord entanglement. The multilayer folding sign may be an early indicator of the rupture dividing membrane. Complications resulting from dividing-membrane rupture warrant heightened vigilance, especially amniotic band syndrome and cord entanglement, both of which are associated with adverse perinatal outcomes.
- 7 January 2024
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 43 (4) , 671-681
Study on the Consistency Between Automatic Measurement Based on Convolutional Neural Network Technology and Manual Visual Evaluation in Intracavitary Ultrasonic Cine of Anterior Pelvic
Objectives: This study was to evaluate the application of automatic measurement based on convolutional neural network (CNN) technology in intracavitary ultrasound cine of anterior pelvic.Methods: A total of 500 patients who underwent pelvic floor ultrasound examination at Peking University Shenzhen Hospital from July 2021 to February 2022 were retrospectively retrieved by the picture archiving and communication system (PACS) system, and 300 cases were used as a training set. The training set was labeled by three experienced ultrasound physicians to train CNN models and develop an automatic measurement software. The remaining 200 cases were used as a test set. Automatic measurement software identified relevant anatomical structures frame by frame and determined the two frames with the greatest difference, calculated the bladder neck descent (BND), urethral rotation angle (URA), and retrovesical angle (RA). Meanwhile, two experienced ultrasound physicians evaluated the resting frame and the maximum Valsalva frame on the cines by manual visual evaluation, labeled the anatomical structures in the corresponding frame, such as the inferoposterior margin of pubic symphysis, the mid‐axis of pubic symphysis, bladder contour, and urethra in the front, and calculated BND, URA, and RA. Considering that the residual urine volume (RUV) in the bladder may affect the results, enrolled patients were grouped according to the RUV (10–50 mL, 50–100 mL, and >100 mL). The consistency of the results by automatic measurement and manual visual evaluation was evaluated using the intraclass correlation coefficient (ICC) and the Bland–Altman graph.Results: Of the 200 cases in the test set, 120 cases were successfully identified by the CNN automatic software with a 60% recognition rate. In the case of successful identification, the ICC of manual visual evaluation measurement and automatic measurement was 0.936 (BND), 0.911 (URA), 0.756 (RA in rest), and 0.877 (RA at maximum Valsalva), respectively. In addition, the RUV had a negligible effect on the consistency. The Bland–Altman plot shows the proportion of samples outside the limit was below 5%.Conclusions: CNN‐based automatic measurement software exhibited high reliability in anterior pelvic measurement, which results in a significantly enhanced measurement efficiency.
- 7 January 2024
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 43 (4) , 671-681
Study on the Consistency Between Automatic Measurement Based on Convolutional Neural Network Technology and Manual Visual Evaluation in Intracavitary Ultrasonic Cine of Anterior Pelvic
Objectives: This study was to evaluate the application of automatic measurement based on convolutional neural network (CNN) technology in intracavitary ultrasound cine of anterior pelvic.Methods: A total of 500 patients who underwent pelvic floor ultrasound examination at Peking University Shenzhen Hospital from July 2021 to February 2022 were retrospectively retrieved by the picture archiving and communication system (PACS) system, and 300 cases were used as a training set. The training set was labeled by three experienced ultrasound physicians to train CNN models and develop an automatic measurement software. The remaining 200 cases were used as a test set. Automatic measurement software identified relevant anatomical structures frame by frame and determined the two frames with the greatest difference, calculated the bladder neck descent (BND), urethral rotation angle (URA), and retrovesical angle (RA). Meanwhile, two experienced ultrasound physicians evaluated the resting frame and the maximum Valsalva frame on the cines by manual visual evaluation, labeled the anatomical structures in the corresponding frame, such as the inferoposterior margin of pubic symphysis, the mid‐axis of pubic symphysis, bladder contour, and urethra in the front, and calculated BND, URA, and RA. Considering that the residual urine volume (RUV) in the bladder may affect the results, enrolled patients were grouped according to the RUV (10–50 mL, 50–100 mL, and >100 mL). The consistency of the results by automatic measurement and manual visual evaluation was evaluated using the intraclass correlation coefficient (ICC) and the Bland–Altman graph.Results: Of the 200 cases in the test set, 120 cases were successfully identified by the CNN automatic software with a 60% recognition rate. In the case of successful identification, the ICC of manual visual evaluation measurement and automatic measurement was 0.936 (BND), 0.911 (URA), 0.756 (RA in rest), and 0.877 (RA at maximum Valsalva), respectively. In addition, the RUV had a negligible effect on the consistency. The Bland–Altman plot shows the proportion of samples outside the limit was below 5%.Conclusions: CNN‐based automatic measurement software exhibited high reliability in anterior pelvic measurement, which results in a significantly enhanced measurement efficiency.
- Open Access
- 15 February 2023
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 13 (2) , 332
Successful Ultrasound-Guided Methotrexate Intervention in the Treatment of Heterotopic Interstitial Pregnancy: A Case Report and Literature Review
Purpose: This study aims to share the experience of minimally invasive ultrasound-guided methotrexate intervention in the treatment of heterotopic interstitial pregnancy (HIP) with good pregnancy outcomes, and to review the treatment, pregnancy outcomes, and impact on the future fertility of HIP patients. Methods: The paper describes the medical history, clinical manifestations, treatment history, and clinical prognosis of a 31-year-old woman with HIP, and reviews cases of HIP from 1992 to 2021 published in the PubMed database. Results: The patient was diagnosed with HIP by transvaginal ultrasound (TVUS) at 8 weeks after assisted reproductive technology. The interstitial gestational sac was inactivated by ultrasound-guided methotrexate injection. The intrauterine pregnancy was successfully delivered at 38 weeks of gestation. Twenty-five HIP cases in 24 studies published on PubMed from 1992 to 2021 were reviewed. Combined with our case, there were 26 cases in total. According to these studies, 84.6% (22/26) of these cases were conceived by in vitro fertilization embryo transfer, 57.7% (15/26) had tubal disorders, and 23.1% (6/26) had a history of ectopic pregnancy; 53.8% (14/26) of the patients presented with abdominal pain and 19.2% (5/26) had vaginal bleeding. All cases were confirmed by TVUS. In total, 76.9% (20/26) of intrauterine pregnancies had a good prognosis (surgery vs. ultrasound interventional therapy 1:1). All fetuses were born without abnormalities. Conclusions: The diagnosis and treatment of HIP remain challenging. Diagnosis mainly relies on TVUS. Interventional ultrasound therapy and surgery are equally safe and effective. Early treatment of concomitant heterotopic pregnancy is associated with high survival of the intrauterine pregnancy.
- 15 February 2023
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 13 (2) , 332
Open AccessSuccessful Ultrasound-Guided Methotrexate Intervention in the Treatment of Heterotopic Interstitial Pregnancy: A Case Report and Literature Review
Purpose: This study aims to share the experience of minimally invasive ultrasound-guided methotrexate intervention in the treatment of heterotopic interstitial pregnancy (HIP) with good pregnancy outcomes, and to review the treatment, pregnancy outcomes, and impact on the future fertility of HIP patients. Methods: The paper describes the medical history, clinical manifestations, treatment history, and clinical prognosis of a 31-year-old woman with HIP, and reviews cases of HIP from 1992 to 2021 published in the PubMed database. Results: The patient was diagnosed with HIP by transvaginal ultrasound (TVUS) at 8 weeks after assisted reproductive technology. The interstitial gestational sac was inactivated by ultrasound-guided methotrexate injection. The intrauterine pregnancy was successfully delivered at 38 weeks of gestation. Twenty-five HIP cases in 24 studies published on PubMed from 1992 to 2021 were reviewed. Combined with our case, there were 26 cases in total. According to these studies, 84.6% (22/26) of these cases were conceived by in vitro fertilization embryo transfer, 57.7% (15/26) had tubal disorders, and 23.1% (6/26) had a history of ectopic pregnancy; 53.8% (14/26) of the patients presented with abdominal pain and 19.2% (5/26) had vaginal bleeding. All cases were confirmed by TVUS. In total, 76.9% (20/26) of intrauterine pregnancies had a good prognosis (surgery vs. ultrasound interventional therapy 1:1). All fetuses were born without abnormalities. Conclusions: The diagnosis and treatment of HIP remain challenging. Diagnosis mainly relies on TVUS. Interventional ultrasound therapy and surgery are equally safe and effective. Early treatment of concomitant heterotopic pregnancy is associated with high survival of the intrauterine pregnancy.
- 7 June 2022
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 42 (1) , 161-169
Transvaginal Two‐Dimensional Ultrasound Evaluation as a Screening Tool for Levator ani Muscle Avulsion in Postpartum Women
Objectives: To evaluate the agreement between two‐dimensional transvaginal ultrasound (2D‐TVUS) and transperineal tomographic ultrasound imaging on three‐dimensional (3D) volume in diagnosing levator ani muscle (LAM) avulsion of postpartum women. Furthermore, we tested the repeatability of the 2D‐TVUS in measuring the LAM thickness.Methods: A retrospective study was performed using the data sets from postpartum women. One doctor measured the thickness of the LAM on the images at the attachment to the arcus tendinous levator ani and the middle part using the 2D‐TVUS ultrasound data sets of postpartum women. These women were examined twice, at 42–56 days and 3–6 months postpartum. Intra‐observer repeatability was expressed using intraclass correlation coefficients (ICCs). The other doctor judged whether there was avulsion in the LAM on the 2D‐TVUS and transperineal tomography imaging on the 3D volume. The inter‐method agreement was determined using Cohen's kappa coefficient (k).Results: Thickness measurements of the middle part and attachment of the LAM by 2D‐TVUS showed excellent and good intra‐observer repeatability (ICC 0.84; 95% CI, 0.76–0.88, and ICC 0.74; 95% CI, 0.67–0.84, respectively). The overall agreement was 92% (Cohen's kappa was 0.79) between 2D‐TVUS and transperineal tomographic imaging. Compared to transperineal tomographic imaging in the diagnosis of LAM avulsion, the diagnostic sensitivity of 2D‐TVUS was 91.7%, the specificity was 92.1%.Conclusions: The 2D‐TVUS technique, a simple and reproducible method for assessing LAM avulsion, may be helpful as a screening tool for LAM avulsion of postpartum women.
- 7 June 2022
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 42 (1) , 161-169
Transvaginal Two‐Dimensional Ultrasound Evaluation as a Screening Tool for Levator ani Muscle Avulsion in Postpartum Women
Objectives: To evaluate the agreement between two‐dimensional transvaginal ultrasound (2D‐TVUS) and transperineal tomographic ultrasound imaging on three‐dimensional (3D) volume in diagnosing levator ani muscle (LAM) avulsion of postpartum women. Furthermore, we tested the repeatability of the 2D‐TVUS in measuring the LAM thickness.Methods: A retrospective study was performed using the data sets from postpartum women. One doctor measured the thickness of the LAM on the images at the attachment to the arcus tendinous levator ani and the middle part using the 2D‐TVUS ultrasound data sets of postpartum women. These women were examined twice, at 42–56 days and 3–6 months postpartum. Intra‐observer repeatability was expressed using intraclass correlation coefficients (ICCs). The other doctor judged whether there was avulsion in the LAM on the 2D‐TVUS and transperineal tomography imaging on the 3D volume. The inter‐method agreement was determined using Cohen's kappa coefficient (k).Results: Thickness measurements of the middle part and attachment of the LAM by 2D‐TVUS showed excellent and good intra‐observer repeatability (ICC 0.84; 95% CI, 0.76–0.88, and ICC 0.74; 95% CI, 0.67–0.84, respectively). The overall agreement was 92% (Cohen's kappa was 0.79) between 2D‐TVUS and transperineal tomographic imaging. Compared to transperineal tomographic imaging in the diagnosis of LAM avulsion, the diagnostic sensitivity of 2D‐TVUS was 91.7%, the specificity was 92.1%.Conclusions: The 2D‐TVUS technique, a simple and reproducible method for assessing LAM avulsion, may be helpful as a screening tool for LAM avulsion of postpartum women.
- Open Access
- 30 December 2021
- Published by Wolters Kluwer Health in Medicine
- Vol. 100 (52) , e28477
Multimodal ultrasound imaging of persistent urogenital sinus with uterus didelphys and double vagina malformation
Rationale: Persistent urogenital sinus (PUG) with uterus didelphys and double vagina is a rare urogenital anomaly. The diagnosis is based on magnetic resonance examination and cystoscopy. To the best of our knowledge, there is no literature report of PUG diagnosed by ultrasound alone. Patient concern: A 23-year-old woman presented with atypical menstruation and recurrent hematuria for 13 years and recurrent lower abdominal pain for 12 years. Diagnosis: PUG was diagnosed through multiple ultrasound modalities, including transabdominal 2-dimensional ultrasound, transrectal bi-plane high-frequency ultrasound, and contrast-enhanced ultrasound. We diagnosed this malformation preoperatively by accurately measuring the length of urethra and common channel through multimodal ultrasound imaging. Interventions: Urethra separation and reconstruction, vaginal pull-through and artificial vaginoplasty, and bilateral hysterosalpingectomy were performed. Outcomes: The postoperative course was uneventful. She was urinating normally after half a year and used continuous vaginal dilatation to avoid stenosis. Lessons: PUG associated with uterus didelphys and double vagina is an extremely rare malformation of the reproductive system. Multimodal ultrasound imaging can be used to diagnose this malformation preoperatively clearly and to accurately measure the length of urethra and common channel, providing an imaging basis for preparing an operative plan.
- 30 December 2021
- Published by Wolters Kluwer Health in Medicine
- Vol. 100 (52) , e28477
Open AccessMultimodal ultrasound imaging of persistent urogenital sinus with uterus didelphys and double vagina malformation
Rationale: Persistent urogenital sinus (PUG) with uterus didelphys and double vagina is a rare urogenital anomaly. The diagnosis is based on magnetic resonance examination and cystoscopy. To the best of our knowledge, there is no literature report of PUG diagnosed by ultrasound alone. Patient concern: A 23-year-old woman presented with atypical menstruation and recurrent hematuria for 13 years and recurrent lower abdominal pain for 12 years. Diagnosis: PUG was diagnosed through multiple ultrasound modalities, including transabdominal 2-dimensional ultrasound, transrectal bi-plane high-frequency ultrasound, and contrast-enhanced ultrasound. We diagnosed this malformation preoperatively by accurately measuring the length of urethra and common channel through multimodal ultrasound imaging. Interventions: Urethra separation and reconstruction, vaginal pull-through and artificial vaginoplasty, and bilateral hysterosalpingectomy were performed. Outcomes: The postoperative course was uneventful. She was urinating normally after half a year and used continuous vaginal dilatation to avoid stenosis. Lessons: PUG associated with uterus didelphys and double vagina is an extremely rare malformation of the reproductive system. Multimodal ultrasound imaging can be used to diagnose this malformation preoperatively clearly and to accurately measure the length of urethra and common channel, providing an imaging basis for preparing an operative plan.
- Open Access
- 1 December 2018
- Published by Oxford University Press (OUP) in Burns & Trauma
- Vol. 6 (1) , 34
Human acellular amniotic membrane implantation for lower third nasal reconstruction: a promising therapy to promote wound healing
Background: The lower third of the nose is one of the most important cosmetic units of the face, and its reconstructive techniques remain a big challenge. As an alternative approach to repair or regenerate the nasal tissue, the biomaterial-based strategy has been extensively investigated. The aim of this study is to determine the safety and efficacy of human acellular amniotic membrane (HAAM) to repair the full-thickness defects in the lower third of the nose in humans. Methods: In this study, 180 patients who underwent excision of skin lesions of the lower third of the nose from 2012 to 2016 were included; of the patients, 92 received HAAM and Vaseline gauze treatments, and the other 88 patients received Vaseline gauze treatment only. The haemostasis time and the duration of operation were recorded during surgery; after surgery, the time to pain disappearance, scab formation and wound healing, and the wound healing rate were measured. Results: Immediately after the HAAM implantation, a reduction of the haemostasis time and an accelerated disappearance of pain were observed. Compared with the control group, the formation and detachment of scab in patients who received the HAAM implantation were notably accelerated, postoperatively. When the diameter of the lesion exceeded 5 mm, the HAAM implantation was found to enhance the wound healing, although this enhancement was not seen when the diameter was less than 5 mm. Additionally, the HAAM implantation significantly reduced bleeding, wound infection and scar formation, postoperatively. Conclusions: HAAM-assisted healing is a promising therapy for lower third nasal reconstruction leading to rapid wound healing and fewer complications and thus has considerable potential for extensive clinical application in repairing skin wounds. Trial registration: ChiCTR1800017618, retrospectively registered on July 08, 2018.
- 1 December 2018
- Published by Oxford University Press (OUP) in Burns & Trauma
- Vol. 6 (1) , 34
Open AccessHuman acellular amniotic membrane implantation for lower third nasal reconstruction: a promising therapy to promote wound healing
Background: The lower third of the nose is one of the most important cosmetic units of the face, and its reconstructive techniques remain a big challenge. As an alternative approach to repair or regenerate the nasal tissue, the biomaterial-based strategy has been extensively investigated. The aim of this study is to determine the safety and efficacy of human acellular amniotic membrane (HAAM) to repair the full-thickness defects in the lower third of the nose in humans. Methods: In this study, 180 patients who underwent excision of skin lesions of the lower third of the nose from 2012 to 2016 were included; of the patients, 92 received HAAM and Vaseline gauze treatments, and the other 88 patients received Vaseline gauze treatment only. The haemostasis time and the duration of operation were recorded during surgery; after surgery, the time to pain disappearance, scab formation and wound healing, and the wound healing rate were measured. Results: Immediately after the HAAM implantation, a reduction of the haemostasis time and an accelerated disappearance of pain were observed. Compared with the control group, the formation and detachment of scab in patients who received the HAAM implantation were notably accelerated, postoperatively. When the diameter of the lesion exceeded 5 mm, the HAAM implantation was found to enhance the wound healing, although this enhancement was not seen when the diameter was less than 5 mm. Additionally, the HAAM implantation significantly reduced bleeding, wound infection and scar formation, postoperatively. Conclusions: HAAM-assisted healing is a promising therapy for lower third nasal reconstruction leading to rapid wound healing and fewer complications and thus has considerable potential for extensive clinical application in repairing skin wounds. Trial registration: ChiCTR1800017618, retrospectively registered on July 08, 2018.