Sameera Pathirana
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sameera Pathirana has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Delwar Hossain
School of Engineering, Design and Built Environment, Western Sydney University, Penrith, NSW 2751, Australia
3 shared publications - Grahame Douglas
School of Engineering, Design and Built Environment, Western Sydney University, Penrith, NSW 2751, Australia
3 shared publications - Kamrul Hassan
School of Engineering, Design and Built Environment, Western Sydney University, Penrith, NSW 2751, Australia
3 shared publications - Payam Rahnamayiezekavat
School of Engineering, Design & Built Environment, Western Sydney University, Locked Bag 1797, Kingswood, NSW 2751, Australia
3 shared publications - Swapan Saha
Western Sydney University
3 shared publications - Fidelis Rutendo Mashiri
Western Sydney University
1 shared publication
Latest Publications
- Open Access
- 7 October 2024
- Published by Taylor & Francis in Australian Journal of Structural Engineering
- Vol. 26 (3) , 175-188
Systematic review of the use of phase change material (PCM) in concrete and the fire performance of PCM in concrete
- 7 October 2024
- Published by Taylor & Francis in Australian Journal of Structural Engineering
- Vol. 26 (3) , 175-188
Open AccessSystematic review of the use of phase change material (PCM) in concrete and the fire performance of PCM in concrete
- Open Access
Fire Incidents, Trends, and Risk Mitigation Framework of Electrical Vehicle Cars in Australia
Electric Vehicles (EVs) offer a promising solution to reduce the environmental impact compared to internal combustion engine vehicles. However, EV adoption in Australia has been hindered by concerns over fire safety. This study aims to comprehensively analyse EV fire risks and trends in Australia, including those related to charging stations and lithium-ion batteries. The research utilises secondary data from various reputable sources to develop statistical forecasting models, which estimate that Australia will have approximately 1.73 million EVs by 2030 and 15.8 million by 2050. The study reveals an average EV fire frequency of six fires per million EVs in Australia, aligning with the global average. Consequently, Australia is expected to experience 9 to 10 EV fire incidents annually in 2030, 37 to 42 EV fire incidents annually in 2040, and 84 to 95 EV fire incidents annually in 2050. To address these risks, an EV fire risk control framework is considered to identify and recommend appropriate measures for life safety, lithium-ion batteries, charging, EV handling, and EV locations. This research provides vital evidence for regulators, policymakers, and the fire industry to effectively manage EV fire risks and enhance preparedness for the growing EV market in Australia.
Open AccessFire Incidents, Trends, and Risk Mitigation Framework of Electrical Vehicle Cars in Australia
Electric Vehicles (EVs) offer a promising solution to reduce the environmental impact compared to internal combustion engine vehicles. However, EV adoption in Australia has been hindered by concerns over fire safety. This study aims to comprehensively analyse EV fire risks and trends in Australia, including those related to charging stations and lithium-ion batteries. The research utilises secondary data from various reputable sources to develop statistical forecasting models, which estimate that Australia will have approximately 1.73 million EVs by 2030 and 15.8 million by 2050. The study reveals an average EV fire frequency of six fires per million EVs in Australia, aligning with the global average. Consequently, Australia is expected to experience 9 to 10 EV fire incidents annually in 2030, 37 to 42 EV fire incidents annually in 2040, and 84 to 95 EV fire incidents annually in 2050. To address these risks, an EV fire risk control framework is considered to identify and recommend appropriate measures for life safety, lithium-ion batteries, charging, EV handling, and EV locations. This research provides vital evidence for regulators, policymakers, and the fire industry to effectively manage EV fire risks and enhance preparedness for the growing EV market in Australia.
- Open Access
Numerical Investigations on the Influencing Factors of Rapid Fire Spread of Flammable Cladding in a High-Rise Building
This paper investigates aluminium composite panels (ACPs) to understand the fire behaviour of combustible cladding systems under different fire scenarios. A fire dynamics simulator (FDS) is used to develop the numerical model of full-scale fire tests of combustible cladding systems using the procedures of the British BS 8414.1 standards. The results obtained from the FDS models are verified with test data. Seven test scenarios are investigated with four distinct parameters, i.e., cavity barrier, air-cavity gap, panel mounting (with and without joining gaps between the panels), and material combustibility qualities. A critical air-cavity gap (50–100 mm) is established at which maximum fire spread is noticed. Furthermore, variations in the cavity barrier, panel mounting, and material combustibility significantly impact the rapid fire spread of ACP cladding systems and the internal failure criterion. The results from the present study can serve as a basis for future research on the full-scale fire-test development of combustible ACPs.
Open AccessNumerical Investigations on the Influencing Factors of Rapid Fire Spread of Flammable Cladding in a High-Rise Building
This paper investigates aluminium composite panels (ACPs) to understand the fire behaviour of combustible cladding systems under different fire scenarios. A fire dynamics simulator (FDS) is used to develop the numerical model of full-scale fire tests of combustible cladding systems using the procedures of the British BS 8414.1 standards. The results obtained from the FDS models are verified with test data. Seven test scenarios are investigated with four distinct parameters, i.e., cavity barrier, air-cavity gap, panel mounting (with and without joining gaps between the panels), and material combustibility qualities. A critical air-cavity gap (50–100 mm) is established at which maximum fire spread is noticed. Furthermore, variations in the cavity barrier, panel mounting, and material combustibility significantly impact the rapid fire spread of ACP cladding systems and the internal failure criterion. The results from the present study can serve as a basis for future research on the full-scale fire-test development of combustible ACPs.
- Open Access
Fire Behaviour of Insulation Panels Commonly Used in High-Rise Buildings
The energy efficiency of buildings drives the replacement of traditional construction materials with lightweight insulating materials. However, energy-efficient but combustible insulation might contribute to the building’s fire load. Therefore, it is necessary to analyse the reaction-to-fire properties of various insulating materials to provide a better understanding of designing a fire-safe structure. In this study, reaction-to-fire tests were carried out to assess the fire behaviour of lightweight polystyrene insulating panels commonly employed in high-rise buildings. The flammability characteristics of expanded polystyrene (EPS) and extruded polystyrene (XPS) were determined using a cone calorimeter under two distinct external irradiance regimes, 35 kW/m2 and 50 kW/m2, to approximate small to medium fire exposure situations. To investigate the effect of a fire-rated (FR) foil layer on a sandwich panel, three distinct test configurations were used: (i) sample without FR layer (standard sample), (ii) sample with FR layer (FR foil), and (iii) damaged layer (foil and vent) for EPS. Except for the smoke toxicity index (STI), the overall fire performance of EPS is superior to that of XPS. The findings of this study are useful in analysing fire performance and fire safety design for lightweight insulation panels.
Open AccessFire Behaviour of Insulation Panels Commonly Used in High-Rise Buildings
The energy efficiency of buildings drives the replacement of traditional construction materials with lightweight insulating materials. However, energy-efficient but combustible insulation might contribute to the building’s fire load. Therefore, it is necessary to analyse the reaction-to-fire properties of various insulating materials to provide a better understanding of designing a fire-safe structure. In this study, reaction-to-fire tests were carried out to assess the fire behaviour of lightweight polystyrene insulating panels commonly employed in high-rise buildings. The flammability characteristics of expanded polystyrene (EPS) and extruded polystyrene (XPS) were determined using a cone calorimeter under two distinct external irradiance regimes, 35 kW/m2 and 50 kW/m2, to approximate small to medium fire exposure situations. To investigate the effect of a fire-rated (FR) foil layer on a sandwich panel, three distinct test configurations were used: (i) sample without FR layer (standard sample), (ii) sample with FR layer (FR foil), and (iii) damaged layer (foil and vent) for EPS. Except for the smoke toxicity index (STI), the overall fire performance of EPS is superior to that of XPS. The findings of this study are useful in analysing fire performance and fire safety design for lightweight insulation panels.