YCYun Hyeok Choi

Yun Hyeok Choi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yun Hyeok Choi has a total of 56 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparison of Clinical and Radiological Outcomes Between Suction Aspiration and Combination Methods of Mechanical Thrombectomy in Patients With Acute Cerebral Infarction: The COMPETE Trial

    by Joonwon Lee, Seung Hun Sheen, Sung-Chul Jin, Yunhyeok Choi, Dongkeun Hyun, Yu Shik Shim, Taehyung Kim, Jinwoo Bae, Chang-Hyun Kim, Min-Yong Kwon, et al.

    Lee J, et al. J Korean Med Sci. 2026 Apr;41:e164. https://doi.org/10.3346/jkms.2026.41.e164


  • Open Access

    Non‐Surgical, In‐Stent Membrane Bioelectronics for Long‐Term Intracranial Pressure Monitoring

    by Jimin Lee, Allison Bateman, Mi Hyeon Kim, Bruno Rigo, Hodam Kim, Jaeho Lee, Yun Hyeok Choi, Robert Herbert, Deok Hee Lee, Woon‐Hong Yeo

    Traditional intracranial pressure (ICP) monitoring methods, using intraventricular catheters, face significant limitations, including high invasiveness, discrete data, calibration complexities, and drift issues, which hinder long‐term and stable monitoring. Here, a non‐surgical, in‐stent membrane bioelectronic system is presented for continuous and reliable ICP monitoring. This platform integrates a capacitive thin‐film sensor with a stent, enabling precise real‐time detection of pressure fluctuations directly within the dural venous sinus without requiring skull penetration or frequent recalibration. The sensor demonstrates a high sensitivity of 0.052%/mmHg and a broad, readable pressure range of 3–30 mmHg while maintaining calibration‐free and drift‐free performance. A series of in vivo studies highlight the system's superior sensitivity, rapid sampling rate, and long‐term stability compared to conventional microcatheters. Statistical analyses reveal a strong agreement between the device and clinical reference, underscoring its potential to revolutionize ICP monitoring. These advancements pave the way for broader clinical applications, minimizing complications and improving patient outcomes in neurocritical care.


  • Safety and Effectiveness of a Novel Integrated Angiography System for Continuous Guidance and Flushing in Diagnostic Cerebral Catheter Angiography: A Randomized Controlled Trial

    by Boseong Kwon, Jong-Tae Yoon, Yun Hyeok Choi, Soo Jeong, Byung Jun Kim, Joon Ho Choi, Sun Moon Hwang, Deok Hee Lee, Yunsun Song

    BACKGROUND AND PURPOSE: The guided angiography system, an integrated angiography system, enables continuous guidance and flushing during diagnostic procedures. A guidewire provides guidance by remaining inside the catheter during contrast injection into tortuous vessels. While its feasibility was demonstrated in a retrospective study, this randomized controlled trial aims to evaluate its safety and effectiveness. MATERIALS AND METHODS: This single-center, single-blind, randomized controlled trial was conducted from September 2021 to June 2022. Patients with unruptured intracranial aneurysms were enrolled and randomly assigned to either the guided or the conventional group. Primary outcomes were procedural time and serious adverse events. Secondary outcomes included catheterization success, adverse events, fluoroscopy time, fluoroscopy dose, and image quality. RESULTS: A total of 200 participants (mean age, 59 [SD, 10 years], 71% women) were randomized into the guided (n = 100) and the conventional (n = 100) groups. The guided group demonstrated shorter procedural times compared with the conventional group (18.3 [SD, 9.2] versus 21.3 [SD, 8.1] minutes, P < .001). There were no serious adverse events in either group, and adverse events were similar. Catheterization success rates were similar between the guided and conventional groups (93.9% versus 96.8%, P = .226). However, the guided angiography system backed up more catheterization failures from the conventional angiography system, but not vice versa (57.1% versus 11.1%, P = .003). Among catheterization successes, the guided group achieved shorter fluoroscopy time (7.0 versus 7.7 minutes, P = .033) and lower fluoroscopy dose (466.8 versus 566.5 μGy·m2, P = .015). Regarding imaging quality, clinical acceptability was comparable between the guided and conventional groups (95.3% versus 95.5%, P = .781). CONCLUSIONS: The guided angiography system offers a simple and effective alternative for diagnostic cerebral conventional angiography, with reduced radiation exposure and a favorable safety profile. Graphical Abstract

  • Open Access

    Endovascular Treatment of Arterial Steno-Occlusive Lesions in Symptomatic Moyamoya Disease

    by Jae-Chan Ryu, Yun Hyeok Choi, Mi Hyeon Kim, Eun Ji Moon, Youngjin Kim, Boseong Kwon, Yunsun Song, Deok Hee Lee

    The efficacy and safety of endovascular treatment (EVT) for moyamoya disease (MMD) have rarely been investigated. The objective of this study was to summarize the clinical outcomes of EVT for MMD and determine the potential role of EVT in treating symptomatic steno-occlusive lesions in MMD. Reports from January 2000 to December 2021 describing EVT in MMD were collected through a literature search. The search terms included “moyamoya”, “stent”, “angioplasty”, and “endovascular”. Data regarding baseline demographics, previous medical history, treated vessel, periprocedural complications, and angiographical recurrence were retrieved. This review included 10 studies with details of 19 patients undergoing a total of 31 EVT procedures. Twenty-one EVTs were performed as initial treatments for MMD, and 10 were performed as additional treatments for angiographical recurrence. The mean follow-up period of the initial EVTs was 9.0±11.9 months, with angiographical recurrence in 11 (68.8%) cases. The mean follow-up period of additional EVTs was 4.3±3.9 months, and seven (70.0%) EVTs showed restenosis of the re-treated vessel. Across all initial and additional EVTs, there were no differences in characteristics between the recurrence and non-recurrence groups. Overall, two periprocedural complications (9.5%) occurred, one vessel rupture and one massive intracerebral hemorrhage with subarachnoid hemorrhage. EVT plays a limited role in the management of symptomatic intracranial arterial steno-occlusive lesions of MMD. Recent advances in understanding the pathomechanism of MMD may urge neuro-interventionists to find a new endovascular approach with better balloon angioplasty or stenting mechanisms.


  • Open Access

    Physiologic Flow Diversion Coiling Technique for Wide-Necked Aneurysms with an Asymmetric Bidirectional Flow at the Aneurysm Neck

    by Boseong Kwon, Yunsun Song, Yun Hyeok Choi, Dae Chul Suh

    Purpose: Wide-necked aneurysms in the circle of Willis (CoW) are prone to recur due to reciprocal bidirectional flow. We present a novel concept of coil embolization to prevent recurrence that uses physiologic flow diversion at the CoW.Materials and Methods: We enrolled 14 patients (15 aneurysms) who underwent aneurysm coiling for wide-necked aneurysms with asymmetric bidirectional inflow into the aneurysm. Four patients had recurrent aneurysms after coiling. The concept of physiologic flow diversion included obliterating antegrade flow into the aneurysm sac as well as opposite CoW flow by performing compact coil packing with intentional protrusion out of the aneurysm neck to the communicating part.Results: Fifteen aneurysms, including 4 recurrent aneurysms, in an anterior communicating artery (n=7), posterior communicating artery (n=5), and tip of the basilar artery (n=3) were treated with coil embolization (n=10) and stent-assisted coiling (n=5). All aneurysms had a wide neck, and the mean largest diameter was 9.0 mm. The mean packing density was 45.1%. Twelve aneurysms were completely occluded, and 3 aneurysms had tiny residual neck remnants. There was neither a neurological event nor recurrence during the mean 12.5 months of follow-up.Conclusion: Wide-necked aneurysms at the CoW tend to recur. As a strategy to prevent a recurrence, physiologic flow diversion can be an option in treating wide-necked aneurysms in the CoW.


  • Open Access

    Reversible Symptom Aggravation by Intake of Taurine-Rich Foods in Patients with Venous Congestive Myelopathy: Controlled Case Series Study

    by Dae Chul Suh, Soo Jeong, Yun Hyeok Choi, Su Min Cho, Su Young Yun, A Yeun Son, Young Min Lim, Boseong Kwon, Yunsun Song

    Purpose: Reversible aggravation of myelopathy symptoms was observed after the intake of taurine-rich foods in patients with venous congestive myelopathy (VCM) caused by a spinal arteriovenous shunt (SAVS), and the taurine-challenge test was applied to demonstrate an association between taurine and VCM.Materials and Methods: The current study reviewed any aggravation history of myelopathy symptoms, including walking difficulty, after consuming taurine-rich foods among 133 consecutive patients with a SAVS from a prospective institutional database from June 2013 to February 2021. The type of taurine-rich foods, demographic data, arteriovenous shunt level, and follow-up periods were obtained. For the controlled taurine challenge test, Bacchus® (Dong-A Pharmaceutical, Seoul, Korea), a taurine-rich drink, was given to patients who fulfilled test criteria of recovered VCM (pain-sensory-motor-sphincter scale ≥2, improvement of spinal cord signal intensity on magnetic resonance imaging, and follow-up >6 months after SAVS treatment) to confirm the disappearance of such aggravation.Results: Ten patients had an aggravation history related to food. Webfoot octopus, small octopus, squid, crab, scallop, and taurine-rich energy drink (Bacchus®) were related to such aggravation in patients with VCM. Aggravation appeared about 30 minutes after food intake followed by expressions such as ‘I could not walk and collapsed to the ground’ and usually lasted for about 3 hours, followed by a slow recovery after taking rest. Four patients who met the test criteria underwent the taurine challenge with Bacchus® and revealed no further symptom aggravation, suggesting that taurine did not affect patients after recovery from VCM.Conclusion: The association between taurine-rich food and reversible symptom aggravation can appear in patients with VCM and disappear after VCM treatment. Aggravation of venous hypertension in the spinal cord is suggested as a mechanism but further elucidation is needed.


  • Open Access

    Outpatient Day-Care Management of Unruptured Intracranial Aneurysm: A Retrospective Cohort Study

    by Dae Chul Suh, Yun Hyeok Choi, Sang Ik Park, Suyoung Yun, So Yeong Jeong, Soo Jeong, Boseong Kwon, Yunsun Song

    Suh DC, et al. Korean J Radiol. 2022 Aug;23(8):828-834. https://doi.org/10.3348/kjr.2021.0940