CVCüneyt Vatansever

Cüneyt Vatansever

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Cüneyt Vatansever has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Influence of gravity frames with partial-strength flush end-plate connections on the collapse fragility of steel frames

    by Cüneyt Vatansever, Alper Demir

    This study investigates the influence of gravity frames equipped with partial-strength flush end-plate beam-to-column connections on the seismic behavior of steel structures featuring special moment-resisting frames. For the connections, a two-bolted and a four-bolted flush end-plate configuration is considered where both are designed to be semi-rigid and partial-strength, to achieve ductile plasticity through end-plate yielding, thereby dissipating seismic energy and contributing to the seismic collapse capacity of the overall structural system without changing the collapse mechanism. In order to accurately implement the nonlinear behavior of the connections into the building models, finite element models of the connections are developed and cyclic loading procedure was applied to obtain the moment-rotation relationships of the connections. The numerical modelling methodology was validated against experimental data from the literature. The moment-rotation curves of the designed connections are then implemented into the structural model, with perimeter moment-resisting frames as its primary lateral force-resisting system. Three different structural models were investigated; a reference frame with conventional pinned beam-to-column connections and two frames utilizing two-bolted and four-bolted flush end-plate beam-to-column connections each. The structural models were analyzed through nonlinear static pushover analysis and incremental dynamic analysis. Seismic performance factors including static overstrength factor and period-based ductility were determined for comparison against the reference frame with pinned gravity connections. The base shear capacities and collapse fragility curves are investigated to further quantify system’s collapse safety margin. It was observed that the buildings utilizing flush end-plate beam-to-column connections achieve up to 30% increase in median collapse capacity, as well as significant increase in post yielding stiffness and base-shear strength.

  • Open Access

    Dışmerkez Çaprazlı Çelik Çerçevelerde Kapasite Tasarımı Yaklaşımının ve Deprem Performansının Zaman Tanım Alanında Doğrusal Olmayan Hesap Yöntemi ile Değerlendirilmesi

    by Alpay Işın, Cüneyt Vatansever

    Bu çalışma kapsamında, Türkiye Bina Deprem Yönetmeliği-2018 (TBDY-2018)’de belirtilen boyutlandırma esaslarına uygun olarak tasarımı yapılan, her iki asal doğrultusunda yatay yüklerin süneklik düzeyi yüksek dışmerkez çaprazlı çelik çerçeveler tarafından karşılandığı yedi katlı bir ofis binasının deprem performansı, zaman tanım alanında doğrusal olmayan hesap yöntemi kullanılarak değerlendirilmiştir. Taşıyıcı sistemi oluşturan elemanların doğrusal olmayan davranışları için yığılı plastik davranış (plastik mafsal) modeli esas alınmıştır. Çalışmada, on bir farklı deprem yer hareketi kullanılarak toplam yirmi iki adet zaman tanım alanında doğrusal olmayan analiz gerçekleştirilmiştir. Değerlendirmede taban ve kat kesme kuvvetleri, göreli kat ötelenmeleri, çapraz ve kolonlarda oluşan iç kuvvet talepleri, bağ kirişlerindeki kesme kuvveti – yer değiştirme ve moment – dönme talepleri dikkate alınmıştır. Zaman tanım alanında doğrusal olmayan yirmi iki adet analiz sonucu elde edilen taleplerin ortalama değerleri esas alınarak, TBDY 2018’de dış merkez çaprazlı çelik çerçeveler için öngörülen kapasite tasarımı yaklaşımının yeterliliği araştırılmış ve bina taşıyıcı sisteminin deprem performansı değerlendirilmiştir.


  • H- ve I- enkesitli Avrupa profillerinden teşkil edilen bağ kirişlerinde pekleşme katsayısının incelenmesi

    by Haluk Emre Alçi̇çEk, Cüneyt Vatansever

    Dışmerkez çaprazlı çelik çerçeveler (DMÇÇÇ), deprem etkisinde plastik şekildeğiştirmelerin sadece bağ kirişlerinde oluştuğu ve yapı sistemine etkiyen deprem enerjisinin akmaya ulaşan bağ kirişlerinin dönme deformasyonları ile sönümlendiği yatay yük taşıyıcı sistemlerdir. DMÇÇÇ sistemlerde birleşimler, kolonlar, çaprazlar ve bağ kirişi dışında kalan kiriş bölümleri pekleşme etkilerinin de dikkate alındığı, bağ kirişinin plastikleşmesine neden olan yükleme durumu altında hesaplanan tasarım kuvvetlerini karşılayacak şekilde boyutlandırılmaktadır. Bağ kirişi dışındaki elemanların tamamen elastik kalmasının sağlanması amacıyla tasarım dayanımlarının; deprem etkileri altında hesaplanan iç kuvvetlerin tasarım büyütme katsayısı ile büyütülerek yük birleşimlerinde kullanılması ile elde edilmesi gerekmektedir. Tasarım büyütme katsayılarının hesabında esas alınan pekleşme etkileri, TBDY 2018’de tanımlanan pekleşme katsayıları ile dikkate alınmaktadır. Çalışma kapsamında Avrupa tipi I-enkesitli (dar başlıklı / IPE) ve H-enkesitli (geniş başlıklı / HEB) çelik profiller ile teşkil edilen bağ kirişleri için pekleşme katsayısının incelenmesi amaçlanmıştır. Bu kapsamda 280 adet bağ kirişinin doğrusal olmayan sonlu eleman modeli tekrarlı tersinir (çevrimsel) yükleme altında analiz edilerek, kısa, orta ve uzun bağ kirişleri için pekleşme katsayıları elde edilmiştir. Bu katsayılar değerlendirildiğinde, TBDY 2018 kapsamında 1,25 olarak belirtilen pekleşme katsayısının orta ve uzun bağ kirişleri için uygun bir değer olduğu, ancak kısa bağ kirişleri için bu değerin; IPE profil kullanılması halinde ortalama olarak 1,68, HEB profil kullanılması halinde ise, ortalama olarak 1,65 olması gerektiği sonucuna varılmıştır, ayrıca normalleştirilmiş bağ kirişi uzunluğuna bağlı olarak pekleşme katsayısı formülü geliştirilmiştir.


  • Influence of Gravity Framing on the Collapse Probability of Steel Buildings with Special Moment Frames

    by Adem Karasu, Cüneyt Vatansever

    En tr This paper presents the influence of gravity framing on the collapse risk of steel frame buildings with perimeter special moment frames (SMFs) designed in Turkey. For this, four- and eight-story buildings have been designed considering the related current specifications and codes. Header end-plate connections are used for the beam-to-column joints of the gravity frame system. A nonlinear analytical model that simulates the hysteretic behavior of header end-plate connections is calibrated with past experimental data. Nonlinear static pushover analysis (NSPA) and nonlinear response history analyses (NRHAs) were implemented for both four-story and eight-story SMFs with and without the gravity framing to quantify their collapse performance and monitor the system-level seismic response of the building through collapse. The advantage of presence of the gravity framing is investigated and differences in structural responses between the models are also examined. When the models were excited by different ground motions, median responses of the detailed models showed an increase in lateral force carrying capacity and a decrease in first-story drift demand, compared to the nonlinear static pushover analyses results. Furthermore, the results demonstrate that gravity frames in a structure profoundly decrease the possibility of collapse. This paper presents the influence of gravity framing on the collapse risk of steel frame buildings with perimeter special moment frames (SMFs) designed in Turkey. For this, four- and eight-story buildings have been designed considering the related current specifications and codes. Header end-plate connections are used for the beam-to-column joints of the gravity frame system. A nonlinear analytical model that simulates the hysteretic behavior of header end-plate connections is calibrated with past experimental data. Nonlinear static pushover analysis (NSPA) and nonlinear response history analyses (NRHAs) were implemented for both four-story and eight-story SMFs with and without the gravity framing to quantify their collapse performance and monitor the system-level seismic response of the building through collapse. The advantage of presence of the gravity framing is investigated and differences in structural responses between the models are also examined. When the models were excited by different ground motions, median responses of the detailed models showed an increase in lateral force carrying capacity and a decrease in first-story drift demand, compared to the nonlinear static pushover analyses results. Furthermore, the results demonstrate that gravity frames in a structure profoundly decrease the possibility of collapse.


  • Experimental and Numerical Investigation of Unreinforced Masonry Walls with and without Opening

    by Bilge Doran, Metin Karslioglu, Zeynep Unsal Aslan, Cuneyt Vatansever

    This paper comparatively addresses the numerical modeling techniques for simulating the nonlinear behavior of unreinforced masonry (URM) walls. An experimental test program including two specimens with and without opening was conducted to document the behavior of the specimens. Both specimens were subjected to constant axial load and monotonically increasing in-plane lateral load during the tests. Two different modeling approaches, macro and detailed micro modeling, were considered to develop the finite element models (FEMs) of URM walls. The numerical simulation was performed using ABAQUS finite element software. The results of both modeling strategies were compared with experimental results in terms of the lateral load–displacement response and crack pattern of URM walls. Based on the comparison, the approaches implemented for numerical analyses are found reasonably applicable for simulating the in-plane response of URM walls with and without opening under lateral load.


  • Experimental Study on the Behavior of Header End - Plate Connections under Cyclic Loading

    by Adem Karasu, Cüneyt Vatansever

    This paper presents the results from experimental study on the actual behavior of header end-plate connections. To better understand the hysteretic behavior of these connections in terms of the stiffness and the strength, sixteen specimens were considered and subjected to cyclic loads. The effect of some parameters such as thickness of the header end-plate, depth of the connection and the number of bolt rows on the behavior of header end-plate connections has been investigated by the help of experimental tests and finite element (FE) analyses. The moment-rotation relations of the connections governed by three parameters such as, initial stiffness, moment capacity and rotation capacity were obtained. Results revealed that the moment capacity increases with the increase in end-plate thickness and depth of connection. However, for the equal connection depth, increasing the number of bolt rows has not influenced the connection behavior remarkably.


  • Snow induced collapse of hail protection canopies

    by Cüneyt Vatansever, Edip Seçkin, Gökhan Yazıcı