Dorian Dominguez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Dorian Dominguez has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Alberto Gino Lorenzoni
Department of Animal Science, The Pennsylvania State University, University Park, PA 16802, USA
1 shared publication Daniel W Hofstetter
1 shared publicationEileen E Fabian
1 shared publicationLorenzoni Gino
1 shared publicationMark Jenkins
Animal Parasitic Diseases Laboratory, Agricultural Research Service, United States Department of Agriculture, Beltsville, MD 20705-2359, USA
1 shared publication- Surinder Chopra
Department of Plant Science, The Pennsylvania State University, University Park, PA 16802, USA
1 shared publication
Latest Publications
- Open Access
- 23 February 2022
- Published by Elsevier in Poultry Science
- Vol. 101 (5) , 101796
Inclusion of high-flavonoid corn in the diet of broiler chickens as a potential approach for the control of necrotic enteritis
- 23 February 2022
- Published by Elsevier in Poultry Science
- Vol. 101 (5) , 101796
Open AccessInclusion of high-flavonoid corn in the diet of broiler chickens as a potential approach for the control of necrotic enteritis
- 1 January 2021
- Published by American Society of Agricultural and Biological Engineers (ASABE)
- p. 1
Update on ammonia generator for maintaining a set indoor gas concentration for poultry health research
Ammonia gas (NH3) generators were operated continuously for six weeks to maintain a concentration of 50.5 parts per million (ppm) of ammonia gas in two controlled environmental chambers to study poultry physiological response to sustained elevated levels of ammonia gas. The controlled environmental chambers had dimensions of 3.7 x 4.3 x 2.4m (12 x 14 x 8 ft) and were equipped with a 1.5 m3/s (3,060 cfm) recirculation system that regulated indoor temperature levels and a 0.06 m3/s (130 cfm) exhaust fan that exchanged indoor air for fresh outdoor air. The ammonia generators released ammonia gas and water vapor using ultrasonic humidifiers filled with commonly available ammonia cleaning liquid with output controlled by a metallic oxide MQ-137 ammonia gas sensor connected to an Arduino-based control system. Relative humidity regulation was not functional in the chambers, which presented challenges for the gas sensors used to control NH3 concentration, and frequent calibration adjustments of the gas sensors was necessary. Previous results demonstrated two ammonia generators operating together in one chamber filled with 3.8L (1 gallon) each of 2% ammonia cleaning liquid produced 49.45 ± 0.79 ppm of ammonia gas for a duration of 30 hours before running empty. Results from this six-week experiment show that 3.8L (1 gallon) of 10% ammonia cleaning liquid in a single ammonia generator in each chamber could maintain the target gas level of 51.24 ± 1.53 ppm for a duration of 195 hours before refilling was required. The higher strength ammonia solution required fine tuning of the control system to achieve the same accuracy, but it could respond to environmental changes more rapidly and resulted in less run time to maintain the same gas levels.
- 1 January 2021
- Published by American Society of Agricultural and Biological Engineers (ASABE)
- p. 1
Update on ammonia generator for maintaining a set indoor gas concentration for poultry health research
Ammonia gas (NH3) generators were operated continuously for six weeks to maintain a concentration of 50.5 parts per million (ppm) of ammonia gas in two controlled environmental chambers to study poultry physiological response to sustained elevated levels of ammonia gas. The controlled environmental chambers had dimensions of 3.7 x 4.3 x 2.4m (12 x 14 x 8 ft) and were equipped with a 1.5 m3/s (3,060 cfm) recirculation system that regulated indoor temperature levels and a 0.06 m3/s (130 cfm) exhaust fan that exchanged indoor air for fresh outdoor air. The ammonia generators released ammonia gas and water vapor using ultrasonic humidifiers filled with commonly available ammonia cleaning liquid with output controlled by a metallic oxide MQ-137 ammonia gas sensor connected to an Arduino-based control system. Relative humidity regulation was not functional in the chambers, which presented challenges for the gas sensors used to control NH3 concentration, and frequent calibration adjustments of the gas sensors was necessary. Previous results demonstrated two ammonia generators operating together in one chamber filled with 3.8L (1 gallon) each of 2% ammonia cleaning liquid produced 49.45 ± 0.79 ppm of ammonia gas for a duration of 30 hours before running empty. Results from this six-week experiment show that 3.8L (1 gallon) of 10% ammonia cleaning liquid in a single ammonia generator in each chamber could maintain the target gas level of 51.24 ± 1.53 ppm for a duration of 195 hours before refilling was required. The higher strength ammonia solution required fine tuning of the control system to achieve the same accuracy, but it could respond to environmental changes more rapidly and resulted in less run time to maintain the same gas levels.