QJQingxi Jin

Qingxi Jin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Qingxi Jin has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effect of Adding Al on the Phase Structure and Gettering Performance of TiZrV Non-Evaporable Getter Materials

    by Lulu Wang, Yang Li, Deyu Guo, Qingxi Jin, Zhenbin Zhang, Zhimin Yang

    Titanium zirconium vanadium (TiZrV) is a widely used non-evaporable getter (NEG) material with the characteristics of a low activation temperature and a large gas absorption capacity. At present, the research on TiZrV getters mainly focuses on the thin-film state, with little research on the bulk state. In this paper, a TiZrV getter was optimized by adding Al, and the phase structure, activation properties, and gettering performance were studied. With the addition of Al, the α-Zr phase and Ti2Zr phase changed into the Ti-Zr phase and Al-Zr, Al-Ti phase. The newly generated phase promoted the diffusion of hydrogen and oxygen atoms. The activation temperature decreased significantly, as shown in the in situ XPS results. The H2 and CO gettering performance of TiZrVAl samples was promoted to 2073 cm3·s−1 and 1912.8 cm3·s−1, increased by 40.7% and 40.3%. This paper provides valuable ideas for optimizing the properties of bulk TiZrV getters.


  • Open Access

    An All-Dielectric Metamaterial Terahertz Biosensor for Cytokine Detection

    by Kuo Men, Ziwei Lian, Hailing Tu, Hongbin Zhao, Qianhui Wei, Qingxi Jin, Changhui Mao, Feng Wei

    In this paper, we report an all-dielectric metamaterial terahertz biosensor, which exhibits a high Q factor of 35 at an 0.82 resonance peak. A structure with an electromagnetically induced transparency effect was designed and fabricated to perform a Mie resonance for the terahertz response. The biosensor exhibits a limit of detection of 100 pg/mL for cytokine interleukin 2 (IL-2) and a linear response for the logarithm of the concentration of IL-2 in the range of 100 pg/mL to 1 μg/mL. This study implicates an important potential for the detection of cytokines in serum and has potential application in the clinical detection of cytokine release syndrome.


  • Open Access

    Polyethylene Glycol Functionalized Silicon Nanowire Field-Effect Transistor Biosensor for Glucose Detection

    by Yan Zhu, Qianhui Wei, Qingxi Jin, Gangrong Li, Qingzhu Zhang, Han Xiao, Tengfei Li, Feng Wei, Yingchun Luo

    Accurate monitoring of blood glucose levels is crucial for the diagnosis of diabetes patients. In this paper, we proposed a simple “mixed-catalyzer layer” modified silicon nanowire field-effect transistor biosensor that enabled direct detection of glucose with low-charge in high ionic strength solutions. A stable screening system was established to overcome Debye screening effect by forming a porous biopolymer layer with polyethylene glycol (PEG) modified on the surface of SiNW. The experimental results show that when the optimal ratio (APTMS:silane-PEG = 2:1) modified the surface of silicon nanowires, glucose oxidase can detect glucose in the concentration range of 10 nM to 10 mM. The sensitivity of the biosensor is calculated to be 0.47 μAcm−2mM−1, its fast response time not exceeding 8 s, and the detection limit is up to 10 nM. This glucose sensor has the advantages of high sensitivity, strong specificity and fast real-time response. Therefore, it has a potential clinical application prospect in disease diagnosis.


  • Open Access

    Acrylamide Hydrogel-Modified Silicon Nanowire Field-Effect Transistors for pH Sensing

    by Gangrong Li, Qianhui Wei, Shuhua Wei, Jing Zhang, Qingxi Jin, Guozhi Wang, Jiawei Hu, Yan Zhu, Yun Kong, Qingzhu Zhang, et al.

    In this study, we report a pH-responsive hydrogel-modified silicon nanowire field-effect transistor for pH sensing, whose modification is operated by spin coating, and whose performance is characterized by the electrical curve of field-effect transistors. The results show that the hydrogel sensor can measure buffer pH in a repeatable and stable manner in the pH range of 3–13, with a high pH sensitivity of 100 mV/pH. It is considered that the swelling of hydrogel occurring in an aqueous solution varies the dielectric properties of acrylamide hydrogels, causing the abrupt increase in the source-drain current. It is believed that the design of the sensor can provide a promising direction for future biosensing applications utilizing the excellent biocompatibility of hydrogels.