Jing Fu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jing Fu has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- Juang Huang
Institute of Plasma Physics, Hefei Institutes of Physical Science Chinese Academy of Sciences, Hefei 230031, China
3 shared publications - Bo Lyu
Institute of Plasma Physics, Chinese Academy of Sciences
2 shared publications - Hai-Qing Liu
Institute of Plasma Physics, Hefei Institutes of Physical Science, Chinese Academy of Sciences 1 , Hefei 230031
2 shared publications - Xihui Wang
Institute of Plasma Physics, Hefei Institutes of Physical Science Chinese Academy of Sciences, Hefei 230031, China
2 shared publications the EAST Team
2 shared publicationsBaolong Hao
Institute of Plasma Physics, HFIPS, Chinese Academy of Sciences, Hefei 230031, People’s Republic of China
1 shared publication
Latest Publications
- Open Access
- 26 November 2024
- Published by IOP Publishing in Nuclear Fusion
- Vol. 65 (1) , 016026
Beam-ion losses velocity-space distribution under neutral-beam injection on EAST
The velocity-space distribution of the fast-ion loss in EAST neutral-beam injection (NBI) heating discharge is obtained both from Scintillator-based fast-ion loss detector (FILD) signals and by ASCOT5 and FILDSIM simulations. The results of simulations are in good agreement with the distribution of beam-ion losses measured with FILD of EAST and the correctness of the fast-ion loss distribution has been demonstrated. Simulations indicate that the beam-ion losses observed by the FILD probe are attributed to the fast ions from both the high-field side (HFS) and the low-field side (LFS). However, the beam-ion losses from the HFS (associated with NBI1L) have not been observed experimentally due to the limited detecting range of the FILD probe. Therefore, an upgrade and modification of the FILD probe was carried out in 2022 to enable the detection of fast-ion loss with smaller pitch angles. Comparative analysis is conducted in neutral-beam injection (NBI2R) discharges after the upgrade, which indicates that the velocity-space distribution of beam-ion losses from the HFS has strong agreement between experimental measurements and simulation results. However, the experimental and simulated results of the velocity-space distribution of beam-ion losses from the LFS shows inconsistencies, primarily because the BBNBI module in the simulation does not consider the contributions of boundary neutral particles to neutral-beam deposition (ionization reactions). These conclusions not only provide valuable references for improving the neutral-beam deposition model but also establish a fundamental basis for further exploring the mechanisms of fast-ion loss under various conditions on the EAST tokamak.
- 26 November 2024
- Published by IOP Publishing in Nuclear Fusion
- Vol. 65 (1) , 016026
Open AccessBeam-ion losses velocity-space distribution under neutral-beam injection on EAST
The velocity-space distribution of the fast-ion loss in EAST neutral-beam injection (NBI) heating discharge is obtained both from Scintillator-based fast-ion loss detector (FILD) signals and by ASCOT5 and FILDSIM simulations. The results of simulations are in good agreement with the distribution of beam-ion losses measured with FILD of EAST and the correctness of the fast-ion loss distribution has been demonstrated. Simulations indicate that the beam-ion losses observed by the FILD probe are attributed to the fast ions from both the high-field side (HFS) and the low-field side (LFS). However, the beam-ion losses from the HFS (associated with NBI1L) have not been observed experimentally due to the limited detecting range of the FILD probe. Therefore, an upgrade and modification of the FILD probe was carried out in 2022 to enable the detection of fast-ion loss with smaller pitch angles. Comparative analysis is conducted in neutral-beam injection (NBI2R) discharges after the upgrade, which indicates that the velocity-space distribution of beam-ion losses from the HFS has strong agreement between experimental measurements and simulation results. However, the experimental and simulated results of the velocity-space distribution of beam-ion losses from the LFS shows inconsistencies, primarily because the BBNBI module in the simulation does not consider the contributions of boundary neutral particles to neutral-beam deposition (ionization reactions). These conclusions not only provide valuable references for improving the neutral-beam deposition model but also establish a fundamental basis for further exploring the mechanisms of fast-ion loss under various conditions on the EAST tokamak.
- 11 March 2024
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 66 (4) , 045020
A neoclassical validation of balanced and unbalanced rotations on EAST H-mode discharges
Predicting residual stress (RS) contribution to intrinsic rotation is one of the major challenges in the study of momentum transport in tokamaks. One efficient experimental means of quantifying RS torque magnitude is to generate radially-flat and near-zero rotation profiles, termed ‘balanced rotations’ in this work, using counter-Ip Neutral Beam Injections (NBIs) to effectively cancel the torques from co-Ip NBIs. One remaining question, however, is on whether or not the attained velocity profile is well zeroed and flat enough so that the predicted RS torques based on perfect balance assumption can be used for further studies such as fitting of diffusive and convective coefficients to match with experiments. This article presents a neoclassical means of validating the attained balanced and unbalanced rotations at EAST to consequently validate the predicted RS torque profiles, using TRANSP/NUBEAM and a recently-developed neoclassical rotation/transport code TransROTA (Bae et al 2024 Comput. Phys. Commun. 296 108992). Both balanced and unbalanced EAST H-mode discharges are analyzed to find that the suggested neoclassical validation methodology successfully validates attained balanced rotations. It also finds that neoclassical gyroviscous (NGV) torque serves as the balance-breaking mechanism for axisymmetric plasmas and the balance-breakings start from the core and propagate towards the edge. This work also suggests the possibility of using the neoclassical methodology to find locally-balanced rotations at an elevated velocity range near ∼20 km s−1, which implies possible scaling of RS torques up to a certain elevated velocity range.
- 11 March 2024
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 66 (4) , 045020
A neoclassical validation of balanced and unbalanced rotations on EAST H-mode discharges
Predicting residual stress (RS) contribution to intrinsic rotation is one of the major challenges in the study of momentum transport in tokamaks. One efficient experimental means of quantifying RS torque magnitude is to generate radially-flat and near-zero rotation profiles, termed ‘balanced rotations’ in this work, using counter-Ip Neutral Beam Injections (NBIs) to effectively cancel the torques from co-Ip NBIs. One remaining question, however, is on whether or not the attained velocity profile is well zeroed and flat enough so that the predicted RS torques based on perfect balance assumption can be used for further studies such as fitting of diffusive and convective coefficients to match with experiments. This article presents a neoclassical means of validating the attained balanced and unbalanced rotations at EAST to consequently validate the predicted RS torque profiles, using TRANSP/NUBEAM and a recently-developed neoclassical rotation/transport code TransROTA (Bae et al 2024 Comput. Phys. Commun. 296 108992). Both balanced and unbalanced EAST H-mode discharges are analyzed to find that the suggested neoclassical validation methodology successfully validates attained balanced rotations. It also finds that neoclassical gyroviscous (NGV) torque serves as the balance-breaking mechanism for axisymmetric plasmas and the balance-breakings start from the core and propagate towards the edge. This work also suggests the possibility of using the neoclassical methodology to find locally-balanced rotations at an elevated velocity range near ∼20 km s−1, which implies possible scaling of RS torques up to a certain elevated velocity range.
- Open Access
- 1 December 2023
- Published by IOP Publishing in Nuclear Fusion
- Vol. 64 (1) , 016028
Analysis of beam ion driven Alfvén eigenmode stability induced by Tungsten contamination in EAST
Alfvén eigenmodes (AE) activity is observed in the EAST high β N and low BT discharge 93910, operation scenario dedicated to explore the ITER baseline scenario. AEs are triggered after the plasma is contaminated by Tungsten that causes an abrupt variation of the thermal plasma and energetic particles (EPs) profiles. The aim of the present study is to analyze the AE stability in the 93910 discharge using the gyro-fluid code FAR3d, identifying the AE stability trends by comparing the plasma before and after the Tungsten contamination. Tungsten contamination causes the destabilization of Toroidal AEs (TAE) and Energetic particle modes (EPMs) in the same frequency range and radial location with respect to the experimental observation and M3D-K/GTAW code results. Next, a set of parametric studies are performed to analyze the effect of the thermal plasma and EP parameters on the AE stability. The analysis indicates a lower EP β threshold for the AEs destabilization if the EP energy increases, an improved AE stability of on-axis NBI configurations due to the stronger continuum damping in the inner plasma region as well as a large enhancement of the EP drive as the thermal ion density increases due to a higher ratio of the EP and Alfven velocities. Consequently, the simulations indicate the increment of the thermal ion density after the Tungsten contamination could be the main cause of the AE/EPM destabilization.
- 1 December 2023
- Published by IOP Publishing in Nuclear Fusion
- Vol. 64 (1) , 016028
Open AccessAnalysis of beam ion driven Alfvén eigenmode stability induced by Tungsten contamination in EAST
Alfvén eigenmodes (AE) activity is observed in the EAST high β N and low BT discharge 93910, operation scenario dedicated to explore the ITER baseline scenario. AEs are triggered after the plasma is contaminated by Tungsten that causes an abrupt variation of the thermal plasma and energetic particles (EPs) profiles. The aim of the present study is to analyze the AE stability in the 93910 discharge using the gyro-fluid code FAR3d, identifying the AE stability trends by comparing the plasma before and after the Tungsten contamination. Tungsten contamination causes the destabilization of Toroidal AEs (TAE) and Energetic particle modes (EPMs) in the same frequency range and radial location with respect to the experimental observation and M3D-K/GTAW code results. Next, a set of parametric studies are performed to analyze the effect of the thermal plasma and EP parameters on the AE stability. The analysis indicates a lower EP β threshold for the AEs destabilization if the EP energy increases, an improved AE stability of on-axis NBI configurations due to the stronger continuum damping in the inner plasma region as well as a large enhancement of the EP drive as the thermal ion density increases due to a higher ratio of the EP and Alfven velocities. Consequently, the simulations indicate the increment of the thermal ion density after the Tungsten contamination could be the main cause of the AE/EPM destabilization.
- 20 July 2022
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 64 (9) , 095006
Characterization of beam ion loss in high poloidal beta regime on EAST
A critical issue for achieving the integrated operation of steady-state long-pulse high-confinement (H-mode) plasmas on experimental advanced superconducting tokamak (EAST) is to improve beam ion population confinement during neutral beam injection (NBI). To study the characterization of beam ion loss and improve beam ion confinement, the steady-state long pulse scenario discharges were conducted on EAST (β p ⩾ 2.0, β N ⩾ 1.7, q 95 ⩾ 6.7 and H 98y2 ⩾ 1.1) with NBI heating. Based on neutron yield, the beam voltage and line-averaged electron density were adjusted from 50 kV to 60 kV and 4.4 × 1019 m−3 to 5.0 × 1019 m−3, respectively. The results show that the dominant mechanisms of beam ion loss are shine-through loss, prompt loss, and stochastic ripple loss. The shine-through loss fraction is determined by initial velocity, flight time and entire beam path. The change in prompt loss fraction is caused by the change in the deposition of beam ions. The change in stochastic ripple loss fraction is caused by the change in the initial fraction of trapped-confined ions. Detailed physics shows that the prompt loss fraction during counter-Ip injections (∼45%) is far larger than during co-Ip injections (∼5%) due to the finite orbit width. The lost ions are mainly deposited on the lower divertor or below the midplane since the direction of magnetic drift is vertical down. The orbit types of prompt loss during counter-Ip injections are mainly trapped-lost and ctr-passing lost. To minimize the prompt loss fraction during counter-Ip injections, a reversed Ip configuration (rev-Ip) discharge #94758 was conducted. The result suggests that the beam ion wall load fraction during counter-Ip tangential injection (∼3%) is far lower than that in normal Ip configuration (nor-Ip) discharge #94820. It is also found that the confinement of beam ion population in the counter-Ip injection #94758 was greatly improved when compared to #94820. This study can provide unique support for the improvement of beam ion population confinement and for the performance evaluation of the NBI system on EAST and future tokamaks.
- 20 July 2022
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 64 (9) , 095006
Characterization of beam ion loss in high poloidal beta regime on EAST
A critical issue for achieving the integrated operation of steady-state long-pulse high-confinement (H-mode) plasmas on experimental advanced superconducting tokamak (EAST) is to improve beam ion population confinement during neutral beam injection (NBI). To study the characterization of beam ion loss and improve beam ion confinement, the steady-state long pulse scenario discharges were conducted on EAST (β p ⩾ 2.0, β N ⩾ 1.7, q 95 ⩾ 6.7 and H 98y2 ⩾ 1.1) with NBI heating. Based on neutron yield, the beam voltage and line-averaged electron density were adjusted from 50 kV to 60 kV and 4.4 × 1019 m−3 to 5.0 × 1019 m−3, respectively. The results show that the dominant mechanisms of beam ion loss are shine-through loss, prompt loss, and stochastic ripple loss. The shine-through loss fraction is determined by initial velocity, flight time and entire beam path. The change in prompt loss fraction is caused by the change in the deposition of beam ions. The change in stochastic ripple loss fraction is caused by the change in the initial fraction of trapped-confined ions. Detailed physics shows that the prompt loss fraction during counter-Ip injections (∼45%) is far larger than during co-Ip injections (∼5%) due to the finite orbit width. The lost ions are mainly deposited on the lower divertor or below the midplane since the direction of magnetic drift is vertical down. The orbit types of prompt loss during counter-Ip injections are mainly trapped-lost and ctr-passing lost. To minimize the prompt loss fraction during counter-Ip injections, a reversed Ip configuration (rev-Ip) discharge #94758 was conducted. The result suggests that the beam ion wall load fraction during counter-Ip tangential injection (∼3%) is far lower than that in normal Ip configuration (nor-Ip) discharge #94820. It is also found that the confinement of beam ion population in the counter-Ip injection #94758 was greatly improved when compared to #94820. This study can provide unique support for the improvement of beam ion population confinement and for the performance evaluation of the NBI system on EAST and future tokamaks.