MSMariëlle J. Stam

Mariëlle J. Stam

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mariëlle J. Stam has a total of 43 co-authors. Here are the top co-authors by number of shared publications:

  • Rob M. A. de Bie

    Department of Neurology Amsterdam University Medical Centers, University of Amsterdam, Amsterdam Neuroscience Amsterdam Netherlands

    4 shared publications
  • Deborah Hubers

    Department of Neurology, Amsterdam University Medical Center, Amsterdam Neuroscience, University of Amsterdam, Amsterdam, The Netherlands

    3 shared publications
  • Martijn Beudel

    Department of Neurology, Amsterdam University Medical Center, Amsterdam Neuroscience, University of Amsterdam, Amsterdam, The Netherlands

    3 shared publications
  • Martijn Beudel

    Department of Neurology, Amsterdam University Medical Centres, Amsterdam, The Netherlands

    3 shared publications
  • Rick Schuurman

    Department of Neurosurgery, Amsterdam University Medical Center, Amsterdam Neuroscience, University of Amsterdam, Amsterdam, The Netherlands

    3 shared publications
  • Arthur W G Buijink

    Department of Neurology, Amsterdam University Medical Centres, Amsterdam, Noord-Holland, The Netherlands

    2 shared publications

Latest Publications

  • Open Access

    On the degree of overlap between 7-Tesla MRI tractography-based and local field potential-based electrode contact selection in STN-DBS for Parkinson's disease

    by Y. Wiggerts, P.R. Schuurman, M.J. Stam, D. Hubers, B.J. Keulen, M.G.J. de Neeling, B.C.M. van Wijk, P. van Den Munckhof, R.M.A. de Bie, M. Beudel, et al.

  • Open Access

    Shared and symptom-specific local field potential spectral signatures of motor symptoms in Parkinson's disease

    by Mariëlle J. Stam, Bernadette C.M. van Wijk, Martijn G.J. de Neeling, Bart J. Keulen, Deborah Hubers, Tessa F.C. Floris, Arthur W.G. Buijink, Rick Schuurman, Rob M.A. de Bie, Martijn Beudel


  • Open Access

    Long-term consistency of aperiodic and periodic physiomarkers in subthalamic local field potentials in Parkinson’s disease

    by Mariëlle J. Stam, Bernadette C. M. van Wijk, Arthur W. G. Buijink, Dan Piña-Fuentes, Rob M. A. de Bie, Rick Schuurman, Martijn Beudel

    Beta oscillations (±13–35 Hz) and aperiodic spectral features extracted from local field potential (LFP) recordings have been identified as promising physiomarkers for adaptive deep brain stimulation (aDBS) in Parkinson’s disease. However, the long-term consistency of these signal features across behavioural and clinical conditions remains unclear. Bilateral subthalamic nucleus LFPs were recorded from twelve patients with an average inter-recording interval of 137 days, during rest, a finger-to-nose task and speech, with stimulation switched off and on. Intra-class correlation coefficients indicated moderate between-visit consistency for aperiodic offset and exponent but good to excellent consistency of beta peak power. Most aperiodic and power changes induced by task execution and stimulation were statistically comparable across visits. Results remained inconclusive regarding the properties of beta peaks exhibiting the strongest power suppression post-stimulation. Our findings support the potential of beta peak power as primary physiomarker for aDBS, with aperiodic components as possibly suitable supplementary markers.


  • Open Access

    AI-DBS study: protocol for a longitudinal prospective observational cohort study of patients with Parkinson’s disease for the development of neuronal fingerprints using artificial intelligence

    by Mariëlle J Stam, Martijn G J de Neeling, Bart J Keulen, Deborah Hubers, Rob M A de Bie, Rick Schuurman, Arthur W G Buijink, Bernadette C M van Wijk, Martijn Beudel

    Introduction Deep brain stimulation (DBS) is a proven effective treatment for Parkinson’s disease (PD). However, titrating DBS stimulation parameters is a labourious process and requires frequent hospital visits. Additionally, its current application uses continuous high-frequency stimulation at a constant intensity, which may reduce efficacy and cause side effects. The objective of the AI-DBS study is to identify patient-specific patterns of neuronal activity that are associated with the severity of motor symptoms of PD. This information is essential for the development of advanced responsive stimulation algorithms, which may improve the efficacy of DBS. Methods and analysis This longitudinal prospective observational cohort study will enrol 100 patients with PD who are bilaterally implanted with a sensing-enabled DBS system (Percept PC, Medtronic) in the subthalamic nucleus as part of standard clinical care. Local neuronal activity, specifically local field potential (LFP) signals, will be recorded during the first 6 months after DBS implantation. Correlations will be tested between spectral features of LFP data and symptom severity, which will be assessed using (1) inertial sensor data from a wearable smartwatch, (2) clinical rating scales and (3) patient diaries and analysed using conventional descriptive statistics and artificial intelligence algorithms. The primary objective is to identify patient-specific profiles of neuronal activity that are associated with the presence and severity of motor symptoms, forming a ‘neuronal fingerprint’. Ethics and dissemination Ethical approval was granted by the local ethics committee of the Amsterdam UMC (registration number 2022.0368). Study findings will be disseminated through scientific journals and presented at national and international conferences.


  • Open Access

    Pitfalls and practical suggestions for using local field potential recordings in DBS clinical practice and research

    by Bart E K S Swinnen, Arthur W G Buijink, Mariëlle J Stam, Deborah Hubers, Martijn de Neeling, Bart J Keulen, Francesca Morgante, Bernadette C M van Wijk, Rob M A de Bie, Lucia Ricciardi, et al.

    Objective. Local field potential (LFP) recordings using chronically implanted sensing-enabled stimulators are a powerful tool for indexing symptom presence and severity in neurological and neuropsychiatric disorders, and for enhancing our neurophysiological understanding of brain processes. LFPs have gained interest as input signals for closed-loop deep brain stimulation (DBS) and can be used to inform DBS parameter selection. LFP recordings using chronically implanted sensing-enabled stimulators have various implementational challenges. Approach. Here we describe our collective experience using BrainSense (Medtronic®) for clinical and research work. We aim to provide insightful tips and practical advice to empower readers with the knowledge needed to navigate the intricacies of the device and make the most out of its features. Main results. The central issues that apply to several BrainSense features encompass restricted compatibility of stimulation configuration with sensing, differences in electrophysiological signal properties between ‘stimulation OFF’ and ‘stimulation ON at 0.0 mA’, and challenges associated with the internal clock of the neurostimulator. In addition, since recordings are obtained from bipolar and not monopolar channels, spatial certainty regarding the distribution of LFPs around the DBS electrode is limited. Several options exist to synchronize LFP time series with external data streams, but standardization and generalization are lacking. The use of at-home chronic LFP recording is limited by a low temporal and spectral resolution. Regarding at-home LFP snapshots, LFP time series are not stored, parts of the power spectrum are censored when stimulating at high or low frequencies, and the stimulation amplitude is not readily available. Significance. We discussed practical applications, implementation, system limitations, and pitfalls with the aim that sensing can be better applied for clinical practice and research.


  • Open Access

    Strong Correlation between Clinical Improvement and Low‐Frequency Oscillations in Pediatric Dystonia

    by Deborah Hubers, Larissa R. Heideman, Mariëlle J. Stam, Joke M. Dijk, P. Rick Schuurman, Rob M.A. de Bie, Laura A. van de Pol, Martijn Beudel


  • Open Access

    A comparison of methods to suppress electrocardiographic artifacts in local field potential recordings

    by M.J. Stam, B.C.M. van Wijk, P. Sharma, M. Beudel, D.A. Piña-Fuentes, R.M.A. de Bie, P.R. Schuurman, W.-J. Neumann, A.W.G. Buijink

    Objective: Sensing-enabled neurostimulators for deep brain stimulation (DBS) therapy record neural activity directly from the stimulating electrodes in the form of local field potentials (LFPs). However, these LFPs are often contaminated with electrocardiographic (ECG) artifacts that impede the detection of physiomarkers for adaptive DBS research. This study systematically compared the ability of different ECG suppression methods to recover disease-specific electrical brain activity from ECG-contaminated LFPs. Approach: Three ECG suppression methods were evaluated: (1) QRS interpolation of the Perceive toolbox, (2) four variants of a template subtraction method, and (3) sixteen variants of a singular value decomposition (SVD) method. The performance of these methods was examined using LFPs recorded with the Medtronic PerceptTM PC system from the subthalamic nucleus in nine patients with Parkinson’s disease while stimulation was turned off (“OFF-DBS”; anode disconnected) and while stimulation was turned on at 0 mA (“ON-DBS 0 mA”; anode connected). In addition, ECG-contaminated LFPs were simulated by scaling a co-recorded external ECG signal and adding it to the OFF-DBS LFPs. Main Results: ECG artifacts were present in 10 out of 18 ON-DBS 0 mA recordings. All ECG suppression methods were able to drastically reduce the percent difference of beta band (13 – 35 Hz) spectral power and at least partly recover the beta peak and beta burst dynamics. Using predetermined R-peaks improved the performance of the ECG suppression methods. Lengthening the time window around the R-peaks resulted in stronger reduction in artifact-induced beta band power but at an increased risk of flattening the beta peak and loss of beta burst dynamics. Significance: The SVD method formed the preferred trade-off between artifact cleaning and signal loss, as long as its parameter settings (time window around the R-peaks; number of components) are adequately chosen.