Ahmed H. Nadim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ahmed H. Nadim has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Mahmoud G. Hagag
Postgraduate Program, in Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Cairo University, Giza, Egypt
4 shared publications - Nesma Mahmoud Fahmy
Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Ahram Canadian University, Giza, Egypt
4 shared publications - Ahmed Hemdan
Department of Pharmaceutical Chemistry, College of Pharmacy, Health Science Center, Kuwait University, Jabriya, P.O. Box 24923, Safat 13110, Kuwait
2 shared publications Ali M. Yehia
Analytical Chemistry Department, FacultyofPharmacy, Cairo University, Cairo, Egypt
2 shared publicationsAmal M. Hassan
Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Modern University for Technology and Information, El-Hadaba El-Wosta, Mokatam, 5th district, Cairo, Egypt
2 shared publicationsAya A. Mouhamed
Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Cairo University, Cairo, Egypt
2 shared publications
Latest Publications
- Open Access
- 20 September 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1) , 29180
Integrated sustainability and risk assessment of spectrophotometric methods for determining a veterinary drug combination
Effective, sustainable, and white spectrophotometric methods were developed for the analytical assessment of both rafoxanide (RAF) and Levamisole HCl (LEV). Both components were resolved by constant multiplication coupled with spectrum subtraction (CM-SS), ratio subtraction coupled with spectrum subtraction (RS-SS), LEV was additionally determined by derivative ratio (DD 1 ), or progressively by absorbance subtraction (AS), amplitude modulation (AM), and concentration value (CNV) methods based on isosbestic point and a normalized divisor. For RAF and LEV, the linearity range was set to be either 3.0–40.0 µg/mL or 1.0–15.0 µg/mL and 1.0–13.0 µg/mL, respectively. All proposed methods were validated in accordance with ICH guidelines. No significant differences were found compared to the reported methods. The developed spectrophotometric procedures adhered to the principles of green analytical chemistry (GAC) and were evaluated using the Green Analytical Procedure Index (GAPI) and Analytical Greenness Metric (AGREE). The blueness assessment was conducted using the Blue Applicability Grade Index (BAGI). Whiteness was additionally assessed using the RGB 12 tool. Furthermore, a recent approach to risk assessment was conducted using the Cumulative Validation Score (CVS) to evaluate the methodological risk of the methods. The proposed approaches provide practical and sustainable options for routine QC.
- 20 September 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1) , 29180
Open AccessIntegrated sustainability and risk assessment of spectrophotometric methods for determining a veterinary drug combination
Effective, sustainable, and white spectrophotometric methods were developed for the analytical assessment of both rafoxanide (RAF) and Levamisole HCl (LEV). Both components were resolved by constant multiplication coupled with spectrum subtraction (CM-SS), ratio subtraction coupled with spectrum subtraction (RS-SS), LEV was additionally determined by derivative ratio (DD 1 ), or progressively by absorbance subtraction (AS), amplitude modulation (AM), and concentration value (CNV) methods based on isosbestic point and a normalized divisor. For RAF and LEV, the linearity range was set to be either 3.0–40.0 µg/mL or 1.0–15.0 µg/mL and 1.0–13.0 µg/mL, respectively. All proposed methods were validated in accordance with ICH guidelines. No significant differences were found compared to the reported methods. The developed spectrophotometric procedures adhered to the principles of green analytical chemistry (GAC) and were evaluated using the Green Analytical Procedure Index (GAPI) and Analytical Greenness Metric (AGREE). The blueness assessment was conducted using the Blue Applicability Grade Index (BAGI). Whiteness was additionally assessed using the RGB 12 tool. Furthermore, a recent approach to risk assessment was conducted using the Cumulative Validation Score (CVS) to evaluate the methodological risk of the methods. The proposed approaches provide practical and sustainable options for routine QC.
- Open Access
- 19 July 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1) , 22559
Sustainable miniaturized smartphone-coupled TLC platform for innovative cleaning validation: application to tizanidine combinations under challenging concentration ratios
Cross-contamination in pharmaceutical industry is a critical threat to patient safety, potentially reducing therapeutic efficacy and causing adverse effects and addiction. Drugs with narrow therapeutic index and high abuse potential are high-risk candidates, such as tizanidine (TZN). Its carryover may trigger harmful effects, withdrawal symptoms, and unintended dependence. Although cleaning validation minimizes these risks, rapid and reliable tools are still needed to support routine monitoring. To address this need, a portable at-line analytical platform was developed for TZN determination in combination with aceclofenac (ACF), ibuprofen (IBF), and paracetamol (PRC). It employs FDA-recommended swabbing approach, followed by smartphone-based TLC coupled with Color Analyzer and ImageJ for image processing. It provides a rapid, simple, and eco-friendly on-site tool for cleaning validation, enabling both quantitative analysis and qualitative screening via color density charts; a combination not achieved by reported methods. The mobile phase was optimized as toluene-acetone-ethanol (2.3:2.7:0.6 v/v/v), and smartphone-based analysis parameters were optimized. Validation according to ICH guidelines demonstrated good linearity and high sensitivity for the investigated drugs, with quantitation limits below established acceptance limits. Multidimensional sustainability was confirmed using moGAPI, CACI, VIGI, and RGB-12 assessments, highlighting the method as a novel sustainable tool for reliable cleaning validation of TZN combinations.
- 19 July 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1) , 22559
Open AccessSustainable miniaturized smartphone-coupled TLC platform for innovative cleaning validation: application to tizanidine combinations under challenging concentration ratios
Cross-contamination in pharmaceutical industry is a critical threat to patient safety, potentially reducing therapeutic efficacy and causing adverse effects and addiction. Drugs with narrow therapeutic index and high abuse potential are high-risk candidates, such as tizanidine (TZN). Its carryover may trigger harmful effects, withdrawal symptoms, and unintended dependence. Although cleaning validation minimizes these risks, rapid and reliable tools are still needed to support routine monitoring. To address this need, a portable at-line analytical platform was developed for TZN determination in combination with aceclofenac (ACF), ibuprofen (IBF), and paracetamol (PRC). It employs FDA-recommended swabbing approach, followed by smartphone-based TLC coupled with Color Analyzer and ImageJ for image processing. It provides a rapid, simple, and eco-friendly on-site tool for cleaning validation, enabling both quantitative analysis and qualitative screening via color density charts; a combination not achieved by reported methods. The mobile phase was optimized as toluene-acetone-ethanol (2.3:2.7:0.6 v/v/v), and smartphone-based analysis parameters were optimized. Validation according to ICH guidelines demonstrated good linearity and high sensitivity for the investigated drugs, with quantitation limits below established acceptance limits. Multidimensional sustainability was confirmed using moGAPI, CACI, VIGI, and RGB-12 assessments, highlighting the method as a novel sustainable tool for reliable cleaning validation of TZN combinations.
- 12 February 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 18 (11) , 2331-2342
Rational design of a chitosan-coated cobalt ferrite nanozyme coupled with a molecularly imprinted polymer for trace analysis of buspirone in complex matrices: application in spiked human plasma and environmental water samples
A colorimetric sensor for sensitive and selective determination of buspirone in spiked human plasma and environmental water samples based on a chitosan-coated cobalt ferrite nanozyme with a polydopamine MIP.
- 12 February 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 18 (11) , 2331-2342
Rational design of a chitosan-coated cobalt ferrite nanozyme coupled with a molecularly imprinted polymer for trace analysis of buspirone in complex matrices: application in spiked human plasma and environmental water samples
A colorimetric sensor for sensitive and selective determination of buspirone in spiked human plasma and environmental water samples based on a chitosan-coated cobalt ferrite nanozyme with a polydopamine MIP.
- Open Access
- 8 August 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 29039
Carbon dot based molecularly imprinted polymer for selective fluorometric determination of tetracycline and metronidazole in pharmaceuticals and human plasma
A highly sensitive, selective, and rapid spectrofluorometric method has been developed using fluorescence sensors. This method is based on the highly fluorescent graphene quantum dots coated with silica molecularly imprinted polymers (GQDs-SMIPs) for the determination of tetracycline HCl (TET) and metronidazole (MET). Upon excitation of the GQDs-SMIPs at 260.0 nm for TET and 245.0 nm for MET, strong fluorescence emissions at 292.0 nm were produced for both sensors. Such fluorescence was quenched by the addition of their corresponding molecularly imprinted polymer (MIPs) templates. The quenching effect was linear over the concentration ranges of 15.0–120.0 µM and 15.0–140.0 µM for TET and MET, respectively. Limits of detection (LOD) were 3.55 µM, and 4.48 µM while limits of quantification (LOQ) were 10.75 µM and 13.57 µM for TET and MET, respectively. The fabricated GQDs-SMIPs were characterized using scanning electronic microscopy, Fourier-transform IR spectroscopy, and X-ray diffraction. Selectivity of the method was investigated against potentially interfering substances, including two official impurities of TET and MET. Additionally, this fluorescent technique was successfully applied for the determination of these drugs in pharmaceutical dosage forms and spiked human plasma samples. This approach provides a selective and sensitive fluorometric platform for the determination of the studied drugs in complex matrices and quality control laboratories.
- 8 August 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 29039
Open AccessCarbon dot based molecularly imprinted polymer for selective fluorometric determination of tetracycline and metronidazole in pharmaceuticals and human plasma
A highly sensitive, selective, and rapid spectrofluorometric method has been developed using fluorescence sensors. This method is based on the highly fluorescent graphene quantum dots coated with silica molecularly imprinted polymers (GQDs-SMIPs) for the determination of tetracycline HCl (TET) and metronidazole (MET). Upon excitation of the GQDs-SMIPs at 260.0 nm for TET and 245.0 nm for MET, strong fluorescence emissions at 292.0 nm were produced for both sensors. Such fluorescence was quenched by the addition of their corresponding molecularly imprinted polymer (MIPs) templates. The quenching effect was linear over the concentration ranges of 15.0–120.0 µM and 15.0–140.0 µM for TET and MET, respectively. Limits of detection (LOD) were 3.55 µM, and 4.48 µM while limits of quantification (LOQ) were 10.75 µM and 13.57 µM for TET and MET, respectively. The fabricated GQDs-SMIPs were characterized using scanning electronic microscopy, Fourier-transform IR spectroscopy, and X-ray diffraction. Selectivity of the method was investigated against potentially interfering substances, including two official impurities of TET and MET. Additionally, this fluorescent technique was successfully applied for the determination of these drugs in pharmaceutical dosage forms and spiked human plasma samples. This approach provides a selective and sensitive fluorometric platform for the determination of the studied drugs in complex matrices and quality control laboratories.
- Open Access
- 24 December 2024
- Published by Springer Nature in BMC Chemistry
- Vol. 18 (1) , 1-14
Ecological multivariate assisted spectrophotometric methods for determination of antipyrine and benzocaine HCl in presence of antipyrine official impurity and benzocaine HCl degradant: toward greenness and whiteness
A simple and green chemometrics-assisted spectrophotometric technique has beendeveloped and validated for the determination of antipyrine (ANT) and benzocaine HCl (BEN) along with the official impurity of ANT, antipyrine impurity A (ANT imp-A), and the degradation product of BEN, p-amino benzoic acid (PABA), in their quaternary mixture. Three models were developed and compared: partial least squares (PLS), artificial neural networks (ANN), and multivariate curve resolution-alternating least squares (MCR-ALS) where the four studied drugs were successfully quantified. The quantitative determination of the studied drugs was assessed using percentage recoveries, standard errors of prediction, and root mean square errors of prediction. The ANN model demonstrated the lowest error and the best correlation making it the most accurate method for analysis. The models were constructed in the ranges of 5.0–9.0 µg mL−1 for ANT, 1.0–5.0 µg mL−1 for BEN, 0.5–2.5 µg mL−1 for ANT imp-A, and 0.25–1.25 µg mL−1 for PABA. The established models successfully determined ANT, BEN, ANT imp-A, and PABA with detection limits of 0.312, 0.178, 0.093, and 0.042 µg mL−1 for PLS, 0.185, 0.085, 0.001, and 0.034 µg mL−1 for ANN; and 0.473, 0.240, 0.073, and 0.069 µg mL−1 for MCR-ALS, respectively. The greenness and the whiteness of the proposed method were assessed using two green evaluating approaches: analytical Eco-scale, and AGREE, along with one white analytical chemistry evaluating tool, RGB. The three proposed models were successfully applied for determination of ANT and BEN in their pharmaceutically co-formulated dosage forms. They are also recommended for stability assays and purity testing of these drugs in quality control laboratories.
- 24 December 2024
- Published by Springer Nature in BMC Chemistry
- Vol. 18 (1) , 1-14
Open AccessEcological multivariate assisted spectrophotometric methods for determination of antipyrine and benzocaine HCl in presence of antipyrine official impurity and benzocaine HCl degradant: toward greenness and whiteness
A simple and green chemometrics-assisted spectrophotometric technique has beendeveloped and validated for the determination of antipyrine (ANT) and benzocaine HCl (BEN) along with the official impurity of ANT, antipyrine impurity A (ANT imp-A), and the degradation product of BEN, p-amino benzoic acid (PABA), in their quaternary mixture. Three models were developed and compared: partial least squares (PLS), artificial neural networks (ANN), and multivariate curve resolution-alternating least squares (MCR-ALS) where the four studied drugs were successfully quantified. The quantitative determination of the studied drugs was assessed using percentage recoveries, standard errors of prediction, and root mean square errors of prediction. The ANN model demonstrated the lowest error and the best correlation making it the most accurate method for analysis. The models were constructed in the ranges of 5.0–9.0 µg mL−1 for ANT, 1.0–5.0 µg mL−1 for BEN, 0.5–2.5 µg mL−1 for ANT imp-A, and 0.25–1.25 µg mL−1 for PABA. The established models successfully determined ANT, BEN, ANT imp-A, and PABA with detection limits of 0.312, 0.178, 0.093, and 0.042 µg mL−1 for PLS, 0.185, 0.085, 0.001, and 0.034 µg mL−1 for ANN; and 0.473, 0.240, 0.073, and 0.069 µg mL−1 for MCR-ALS, respectively. The greenness and the whiteness of the proposed method were assessed using two green evaluating approaches: analytical Eco-scale, and AGREE, along with one white analytical chemistry evaluating tool, RGB. The three proposed models were successfully applied for determination of ANT and BEN in their pharmaceutically co-formulated dosage forms. They are also recommended for stability assays and purity testing of these drugs in quality control laboratories.
- 4 May 2024
- Published by Oxford University Press (OUP) in Journal of Chromatographic Science
- Vol. 62 (7) , 627-634
Development of Response Surface Approach for Determination of Paracetamol, Chlorpheniramine Maleate, Caffeine and Ascorbic Acid by Green HPLC Method: A Desirability-Based Optimization
Design of experiment is an efficient and cost-effective tool to optimize the chromatographic separation of a multicomponent mixture. The central composite design was conducted to develop and optimize a green high performance liquid chromatography (HPLC) method for simultaneous quantitation of a quaternary mixture of paracetamol, chlorpheniramine maleate, caffeine and ascorbic acid in their pharmaceutical dosage form as well as the determination of their dissolution profile. A five-level three-factor model was performed to investigate the effect of mobile phase composition, pH and flow rate on enhanced resolution and short run time. Analysis was performed using a Kinitex EVO C18 column and a mobile phase composed of methanol: 0.02 M phosphate buffer pH 3.3 (34:66, v/v) at 1.0 mL/min using photodiode array detection. Optimum chromatographic separation was achieved in <6 min with a desirability of 0.999. Linearity was achieved over a range of 1.00–300.00, 1.00–50.00, 2.00–50.00 and 2.00–100.00 μg/mL for paracetamol, chlorpheniramine maleate, caffeine and ascorbic acid, respectively, with a limit of detection (<0.1 μg/mL). The greenness profile was evaluated using the analytical eco-scale and Analytical GREEnness Metric Approach with values of 81 and 0.77, respectively.
- 4 May 2024
- Published by Oxford University Press (OUP) in Journal of Chromatographic Science
- Vol. 62 (7) , 627-634
Development of Response Surface Approach for Determination of Paracetamol, Chlorpheniramine Maleate, Caffeine and Ascorbic Acid by Green HPLC Method: A Desirability-Based Optimization
Design of experiment is an efficient and cost-effective tool to optimize the chromatographic separation of a multicomponent mixture. The central composite design was conducted to develop and optimize a green high performance liquid chromatography (HPLC) method for simultaneous quantitation of a quaternary mixture of paracetamol, chlorpheniramine maleate, caffeine and ascorbic acid in their pharmaceutical dosage form as well as the determination of their dissolution profile. A five-level three-factor model was performed to investigate the effect of mobile phase composition, pH and flow rate on enhanced resolution and short run time. Analysis was performed using a Kinitex EVO C18 column and a mobile phase composed of methanol: 0.02 M phosphate buffer pH 3.3 (34:66, v/v) at 1.0 mL/min using photodiode array detection. Optimum chromatographic separation was achieved in <6 min with a desirability of 0.999. Linearity was achieved over a range of 1.00–300.00, 1.00–50.00, 2.00–50.00 and 2.00–100.00 μg/mL for paracetamol, chlorpheniramine maleate, caffeine and ascorbic acid, respectively, with a limit of detection (<0.1 μg/mL). The greenness profile was evaluated using the analytical eco-scale and Analytical GREEnness Metric Approach with values of 81 and 0.77, respectively.
- Open Access
- 2 March 2024
- Published by Springer Nature in BMC Chemistry
- Vol. 18 (1) , 1-13
Application of smart chemometric models for spectra resolution and determination of challenging multi-action quaternary mixture: statistical comparison with greenness assessment
A multivariate spectrophotometric method is a potential approach that enables discrimination of spectra of components in complex matrices (e.g., pharmaceutical formulation) serving as a substitution method for chromatography. Four green smart multivariate spectrophotometric models were proposed and validated, including principal component regression (PCR), partial least-squares (PLS), multivariate curve resolution-alternating least squares (MCR-ALS), and artificial neural networks (ANN). The developed chemometric models were compared to resolve highly overlapping spectra of Paracetamol (PARA), Chlorpheniramine maleate (CPM), Caffeine (CAF), and Ascorbic acid (ASC). The four multivariate calibration models were assessed via recoveries percent, and root mean square error of prediction. Hence, the proposed models were efficiently applied with no need for any preliminary separation step. The models were utilized to analyze the studied components in their combined pharmaceutical formulation (Grippostad® C capsules). Analytical GREEnness Metric Approach (AGREE) and eco-scale tools were applied to assess the greenness of the established models and found to be 0.77 and 85, respectively. Moreover, the proposed models have been compared to official ones showing no considerable variations in accuracy and precision. Therefore, these models can be highly advantageous for conducting standard pharmaceutical analysis of the substances researched within product testing laboratories.
- 2 March 2024
- Published by Springer Nature in BMC Chemistry
- Vol. 18 (1) , 1-13
Open AccessApplication of smart chemometric models for spectra resolution and determination of challenging multi-action quaternary mixture: statistical comparison with greenness assessment
A multivariate spectrophotometric method is a potential approach that enables discrimination of spectra of components in complex matrices (e.g., pharmaceutical formulation) serving as a substitution method for chromatography. Four green smart multivariate spectrophotometric models were proposed and validated, including principal component regression (PCR), partial least-squares (PLS), multivariate curve resolution-alternating least squares (MCR-ALS), and artificial neural networks (ANN). The developed chemometric models were compared to resolve highly overlapping spectra of Paracetamol (PARA), Chlorpheniramine maleate (CPM), Caffeine (CAF), and Ascorbic acid (ASC). The four multivariate calibration models were assessed via recoveries percent, and root mean square error of prediction. Hence, the proposed models were efficiently applied with no need for any preliminary separation step. The models were utilized to analyze the studied components in their combined pharmaceutical formulation (Grippostad® C capsules). Analytical GREEnness Metric Approach (AGREE) and eco-scale tools were applied to assess the greenness of the established models and found to be 0.77 and 85, respectively. Moreover, the proposed models have been compared to official ones showing no considerable variations in accuracy and precision. Therefore, these models can be highly advantageous for conducting standard pharmaceutical analysis of the substances researched within product testing laboratories.
- Open Access
- 13 November 2023
- Published by Springer Nature in Sustainable Environment Research
- Vol. 33 (1) , 1-16
Optimization of metal dopant effect on ZnO nanoparticles for enhanced visible LED photocatalytic degradation of citalopram: comparative study and application to pharmaceutical cleaning validation
Metal doping is an effective method to tune the optical and chemical properties of nanoparticles. Herein, a comparative study was conducted to assess the effect of metal dopant (Mg, Cu and Sn) on ZnO nanoparticles for visible LED photocatalysis. The photocatalysts were synthesized via a facile co-precipitation method. Doped ZnO nanoparticles were employed for photodegradation of citalopram; a commonly used antidepressant drug. The structural, morphological and optical properties of the nanoparticles were analyzed using high resolution transmission electron microscopy, X-ray diffraction, Brunauer-Emmett-Teller measurements and diffuse reflectance spectroscopy. A decrease in band gap energy was obtained for Mg (3.21 eV), Cu (3.15 eV) and Sn (3.05 eV) compared to undoped ZnO (3.34 eV). Results showed that the photocatalytic activity of ZnO nanoparticles towards citalopram degradation under visible light was enhanced by doping with Sn which showed superior photocatalytic performance compared to Cu. Whereas, Mg doped ZnO demonstrated the lowest photocatalytic activity. Full factorial design (24) was conducted to investigate the effect of dopant, pH, catalyst loading and initial citalopram concentration on the efficiency of the treatment process. The interaction between the metal dopant and pH had significant impact on photodegradation efficiency. At optimum conditions, 80% degradation of 25 µg mL−1 citalopram was obtained in 2 h using commercially available LED light using 0.5 mg mL−1 Sn doped ZnO. Kinetics of citalopram degradation was also investigated and was found to follow pseudo-first order kinetics. The optimized photocatalytic protocol was successfully applied for treatment of water samples obtained from production lines during the cleaning validation cycles of citalopram. Sn and Cu doped ZnO nanoparticles had great sustainability for wastewater treatment as it kept its catalytic behavior up to three cycles without significant decrease in photocatalytic activity. The integration of such an approach into the currently employed cleaning validation protocols would offer an economical advantage for pharmaceutical wastewater treatment. Graphical Abstract
- 13 November 2023
- Published by Springer Nature in Sustainable Environment Research
- Vol. 33 (1) , 1-16
Open AccessOptimization of metal dopant effect on ZnO nanoparticles for enhanced visible LED photocatalytic degradation of citalopram: comparative study and application to pharmaceutical cleaning validation
Metal doping is an effective method to tune the optical and chemical properties of nanoparticles. Herein, a comparative study was conducted to assess the effect of metal dopant (Mg, Cu and Sn) on ZnO nanoparticles for visible LED photocatalysis. The photocatalysts were synthesized via a facile co-precipitation method. Doped ZnO nanoparticles were employed for photodegradation of citalopram; a commonly used antidepressant drug. The structural, morphological and optical properties of the nanoparticles were analyzed using high resolution transmission electron microscopy, X-ray diffraction, Brunauer-Emmett-Teller measurements and diffuse reflectance spectroscopy. A decrease in band gap energy was obtained for Mg (3.21 eV), Cu (3.15 eV) and Sn (3.05 eV) compared to undoped ZnO (3.34 eV). Results showed that the photocatalytic activity of ZnO nanoparticles towards citalopram degradation under visible light was enhanced by doping with Sn which showed superior photocatalytic performance compared to Cu. Whereas, Mg doped ZnO demonstrated the lowest photocatalytic activity. Full factorial design (24) was conducted to investigate the effect of dopant, pH, catalyst loading and initial citalopram concentration on the efficiency of the treatment process. The interaction between the metal dopant and pH had significant impact on photodegradation efficiency. At optimum conditions, 80% degradation of 25 µg mL−1 citalopram was obtained in 2 h using commercially available LED light using 0.5 mg mL−1 Sn doped ZnO. Kinetics of citalopram degradation was also investigated and was found to follow pseudo-first order kinetics. The optimized photocatalytic protocol was successfully applied for treatment of water samples obtained from production lines during the cleaning validation cycles of citalopram. Sn and Cu doped ZnO nanoparticles had great sustainability for wastewater treatment as it kept its catalytic behavior up to three cycles without significant decrease in photocatalytic activity. The integration of such an approach into the currently employed cleaning validation protocols would offer an economical advantage for pharmaceutical wastewater treatment. Graphical Abstract
- 30 October 2023
- Published by Elsevier in Analytical Biochemistry
- Vol. 683, 115367
Development of potentiometric immunosensor for determination of live attenuated Varicella Vaccine: Potency and stability studies
- 30 October 2023
- Published by Elsevier in Analytical Biochemistry
- Vol. 683, 115367
Development of potentiometric immunosensor for determination of live attenuated Varicella Vaccine: Potency and stability studies