Elizaveta R. Orlova
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Elizaveta R. Orlova has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Aleksandr V. Gorobets
South Ural State University (National Research University), Chelyabinsk, Russia
2 shared publications - Dmitry A. Dorofeev
Krasnov Research Institute of Eye Diseases
2 shared publications - Elena V. Kirilik
Chelyabinsk Public Clinical Hospital No. 2, Chelyabinsk, Russia
2 shared publications - Alexey A. Antonov
Krasnov Research Institute of Eye Diseases
1 shared publication - Artem Z. Tsyganov
S.N. Fyodorov National Medical Research Center for Eye Microsurgery, Moscow, Russia
1 shared publication D. Yu. Vasilenko
LTD Aplit
1 shared publication
Latest Publications
- Open Access
- 30 July 2025
- Published by Springer Nature in Vegetation History and Archaeobotany
- Vol. 35 (2) , 287-312
Archaeobotanical and isotope studies evidence crop cultivation already during the Early Iron Age in the boreal forests of the cis-Urals (Kama river basin)
The boreal forests represented a climatic and ecological challenge for early farmers. While in the boreal zone of Scandinavia evidence of agriculture dates back to the Neolithic, in Western Siberia cereal cultivation started not before the Middle Ages. Here we present the first comprehensive archaeobotanical investigation of archaeological sites from the mid-Kama region of easternmost Europe from the Early Iron Age and Medieval period. The results show that the emergence of agriculture occurred during the Late Ananyino period of the Early Iron Age, the latest in the 4th century bce . Most probably slash-and-burn agriculture was practiced, which very likely included manuring with dung. At that time, 58°N represented the northern border of crop cultivation in Eastern Europe. The main types of cultivated cereals were emmer and barley, which were diversified in the 3rd–5th centuries ce with bread wheat, broomcorn millet and hemp. Wild plants contributed to a diverse diet and indicate strongly altered landscapes around the study sites. The Early Iron Age dominance of emmer connects the origin of agriculture in the mid-Kama region to the Pontic steppe and Caucasus area. Overall, agriculture might have contributed to the increase in Glyadenovo population and occupation of new territories to the north and to the south.
- 30 July 2025
- Published by Springer Nature in Vegetation History and Archaeobotany
- Vol. 35 (2) , 287-312
Open AccessArchaeobotanical and isotope studies evidence crop cultivation already during the Early Iron Age in the boreal forests of the cis-Urals (Kama river basin)
The boreal forests represented a climatic and ecological challenge for early farmers. While in the boreal zone of Scandinavia evidence of agriculture dates back to the Neolithic, in Western Siberia cereal cultivation started not before the Middle Ages. Here we present the first comprehensive archaeobotanical investigation of archaeological sites from the mid-Kama region of easternmost Europe from the Early Iron Age and Medieval period. The results show that the emergence of agriculture occurred during the Late Ananyino period of the Early Iron Age, the latest in the 4th century bce . Most probably slash-and-burn agriculture was practiced, which very likely included manuring with dung. At that time, 58°N represented the northern border of crop cultivation in Eastern Europe. The main types of cultivated cereals were emmer and barley, which were diversified in the 3rd–5th centuries ce with bread wheat, broomcorn millet and hemp. Wild plants contributed to a diverse diet and indicate strongly altered landscapes around the study sites. The Early Iron Age dominance of emmer connects the origin of agriculture in the mid-Kama region to the Pontic steppe and Caucasus area. Overall, agriculture might have contributed to the increase in Glyadenovo population and occupation of new territories to the north and to the south.
- 25 June 2022
- Published by LLC Science and Innovations in Russian Open Medical Journal
- Vol. 11 (2)
Intravitreal Systems For Targeted Drug Delivery To The Posterior Eye Segment: A Systematic Review
Background — Intravitreal implants solve a number of serious problems arising in diseases of the posterior segment of the eyeball. Unlike intravitreal injections, the implant provides a prolonged release of a pharmaceutical drug over time. The review presents the characteristics of existing systems for intravitreal drug delivery: nanosystems, non-biodegradable and biodegradable implants. The review also highlights the main advantages and disadvantages of various implants. Based on the conducted literature review, the following conclusion is formulated: the most promising means of targeted drug delivery of drugs to the posterior segment of the eyeball are biodegradable implants. However, currently existing biodegradable implants do not provide entirely controlled release of the drug (uncontrollable extraction episodes occur at times), which constitutes a serious issue requiring improvement. Objective — to summarize the published data on existing systems for the targeted drug delivery into the vitreous chamber, identifying their major advantages and disadvantages. Material and Methods — Information was searched in such databases as PubMed, Google Scholar and ClinicalTrials.gov, using the keywords in both Russian and English languages: intravitreal implants, intraocular implants, biodegradable implants, non-biodegradable implants, nanosystems, nanoparticles, liposomes, targeted drug delivery, posterior segment of the eye, etc.
- 25 June 2022
- Published by LLC Science and Innovations in Russian Open Medical Journal
- Vol. 11 (2)
Intravitreal Systems For Targeted Drug Delivery To The Posterior Eye Segment: A Systematic Review
Background — Intravitreal implants solve a number of serious problems arising in diseases of the posterior segment of the eyeball. Unlike intravitreal injections, the implant provides a prolonged release of a pharmaceutical drug over time. The review presents the characteristics of existing systems for intravitreal drug delivery: nanosystems, non-biodegradable and biodegradable implants. The review also highlights the main advantages and disadvantages of various implants. Based on the conducted literature review, the following conclusion is formulated: the most promising means of targeted drug delivery of drugs to the posterior segment of the eyeball are biodegradable implants. However, currently existing biodegradable implants do not provide entirely controlled release of the drug (uncontrollable extraction episodes occur at times), which constitutes a serious issue requiring improvement. Objective — to summarize the published data on existing systems for the targeted drug delivery into the vitreous chamber, identifying their major advantages and disadvantages. Material and Methods — Information was searched in such databases as PubMed, Google Scholar and ClinicalTrials.gov, using the keywords in both Russian and English languages: intravitreal implants, intraocular implants, biodegradable implants, non-biodegradable implants, nanosystems, nanoparticles, liposomes, targeted drug delivery, posterior segment of the eye, etc.
- Open Access
- 16 June 2022
- Published by Real Time, Ltd. in Russian Ophthalmological Journal
- Vol. 15 (2 (Прил)) , 49-56
A method for measuring intraocular pressure using artificial intelligence technology and fixed-force applanation tonometry
Purpose. To estimate the accuracy of IOP measurement using artificial intelligence (AI) technologies and applanation tonometry with fixed strength. Material and methods. 290 patients (576 eyes) underwent applanation tonometry according to Maklakov with tonometer weights of 5, 10, and 15 g using a modified elastotonometry technique followed by an analysis of impression quality and diameter measurements by three independent ophthalmologist experts. The prints were then fed into a neural network to check the repeatability and reproducibility of the measurements. Results. The comparison of the diameters of the Maklakov tonometer prints determined by AI based on the neural network with the measurements data provided by three experts showed that neural network underestimates the measurement results by an average of 0.27 (-3.81; 4.35) mm Hg. At the same time, the intraclass correlation coefficient for all prints was 98.3%. The accuracy of diameter measurements of prints by neural network differs for tonometers of different weights, e.g. for a 5 g tonometer the difference was 0.06 (-3.38; 3.49) mm Hg, for 10 g and 15 g tonometers was 0.14 (-3.8; 3.51) and 0.95 (-3.84; 5.74) mm Hg, respectively. Conclusion. High accuracy and reproducibility of the measurements by the neural network, was shown to surpass the reproducibility of human-implemented measurements.
- 16 June 2022
- Published by Real Time, Ltd. in Russian Ophthalmological Journal
- Vol. 15 (2 (Прил)) , 49-56
Open AccessA method for measuring intraocular pressure using artificial intelligence technology and fixed-force applanation tonometry
Purpose. To estimate the accuracy of IOP measurement using artificial intelligence (AI) technologies and applanation tonometry with fixed strength. Material and methods. 290 patients (576 eyes) underwent applanation tonometry according to Maklakov with tonometer weights of 5, 10, and 15 g using a modified elastotonometry technique followed by an analysis of impression quality and diameter measurements by three independent ophthalmologist experts. The prints were then fed into a neural network to check the repeatability and reproducibility of the measurements. Results. The comparison of the diameters of the Maklakov tonometer prints determined by AI based on the neural network with the measurements data provided by three experts showed that neural network underestimates the measurement results by an average of 0.27 (-3.81; 4.35) mm Hg. At the same time, the intraclass correlation coefficient for all prints was 98.3%. The accuracy of diameter measurements of prints by neural network differs for tonometers of different weights, e.g. for a 5 g tonometer the difference was 0.06 (-3.38; 3.49) mm Hg, for 10 g and 15 g tonometers was 0.14 (-3.8; 3.51) and 0.95 (-3.84; 5.74) mm Hg, respectively. Conclusion. High accuracy and reproducibility of the measurements by the neural network, was shown to surpass the reproducibility of human-implemented measurements.