OBOumayma Bouhamama
Oumayma Bouhamama
*This is an algorithmically generated author record based on publicly available information.
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Oumayma Bouhamama has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Laura Bear
IHU-Liryc, Heart Rhythm Disease Institute, Foundation Bordeaux Université, Bordeaux, France
1 shared publication - Lisl Weynans
Institut de Mathématiques de Bordeaux
1 shared publication - Mark Potse
Department of Biomedical Engineering, Cardiovascular Research Institute Maastricht, Maastricht University, Maastricht, The Netherlands
1 shared publication
Latest Publications
- Open Access
- 20 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (1) , 55-66
A Patchwork Method to Improve the Performance of Current Methods for Solving the Inverse Problem of Electrocardiography
Objective: Noninvasive electrocardiographic imaging (ECGI) reconstructs cardiac electrical activity from body surface potential measurements. However, current methods have demonstrated inaccuracies in reconstructing sinus rhythm, and in particular breakthrough sites. This study aims to combine existing inverse algorithms, making the most of their advantages while minimizing their limitations. Method: The “patchwork method” (PM) combines two classical numerical methods for ECGI: the method of fundamental solutions (MFS) and the finite-element method (FEM). We assume that the method with the smallest residual in the predicted torso potentials, computed using the boundary element method (BEM), provides the most accurate solution. The PM selects for each heart node and time step the method whose estimated reconstruction error is smallest. The performance of the PM was evaluated using simulated ectopic and normal ventricular beats. Results: Cardiac potentials and activation maps obtained with the PM (CC=0.63$\pm$ 0.01 and 0.61$\pm$ 0.05 respectively) were more accurate than MFS (CC=0.61$\pm$ 0.01 and 0.48$\pm$ 0.05 respectively), FEM (CC=0.58$\pm$ 0.01 and 0.51$\pm$ 0.02 respectively) or BEM (CC=0.57$\pm$ 0.02 and 0.49$\pm$ 0.02 respectively). The PM also located all epicardial breakthrough sites, whereas the traditional numerical methods usually missed one. Furthermore, the PM showed its robustness and stability in the presence of Gaussian noise added to the torso potentials. Conclusion: The PM overcomes some of the limitations of classical numerical methods, improving the accuracy of mapping important features of activation during sinus rhythm and paced beats. Significance: This novel method for optimizing ECGI solutions opens a new avenue for improving not only ECGI but also other inverse problems.- 20 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (1) , 55-66
Open AccessA Patchwork Method to Improve the Performance of Current Methods for Solving the Inverse Problem of Electrocardiography
Objective: Noninvasive electrocardiographic imaging (ECGI) reconstructs cardiac electrical activity from body surface potential measurements. However, current methods have demonstrated inaccuracies in reconstructing sinus rhythm, and in particular breakthrough sites. This study aims to combine existing inverse algorithms, making the most of their advantages while minimizing their limitations. Method: The “patchwork method” (PM) combines two classical numerical methods for ECGI: the method of fundamental solutions (MFS) and the finite-element method (FEM). We assume that the method with the smallest residual in the predicted torso potentials, computed using the boundary element method (BEM), provides the most accurate solution. The PM selects for each heart node and time step the method whose estimated reconstruction error is smallest. The performance of the PM was evaluated using simulated ectopic and normal ventricular beats. Results: Cardiac potentials and activation maps obtained with the PM (CC=0.63$\pm$ 0.01 and 0.61$\pm$ 0.05 respectively) were more accurate than MFS (CC=0.61$\pm$ 0.01 and 0.48$\pm$ 0.05 respectively), FEM (CC=0.58$\pm$ 0.01 and 0.51$\pm$ 0.02 respectively) or BEM (CC=0.57$\pm$ 0.02 and 0.49$\pm$ 0.02 respectively). The PM also located all epicardial breakthrough sites, whereas the traditional numerical methods usually missed one. Furthermore, the PM showed its robustness and stability in the presence of Gaussian noise added to the torso potentials. Conclusion: The PM overcomes some of the limitations of classical numerical methods, improving the accuracy of mapping important features of activation during sinus rhythm and paced beats. Significance: This novel method for optimizing ECGI solutions opens a new avenue for improving not only ECGI but also other inverse problems.