Chanho Lim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chanho Lim has a total of 90 co-authors. Here are the top co-authors by number of shared publications:
- Nassir F. Marrouche
Tulane University
20 shared publications - Charbel Noujaim
Tulane Research Innovation for Arrhythmia Discovery, Tulane University School of Medicine, New Orleans, Louisiana, USA
12 shared publications - Mario Mekhael
Tulane Research Innovation for Arrhythmia Discovery, Tulane University, 1430 Tulane Avenue, New Orleans, LA, 70112, United States, 1 504-988-3072
10 shared publications - Nour Chouman
Tulane University School of Medicine New Orleans, LA United States
9 shared publications - Ala Assaf
Tulane Research Innovation for Arrhythmia Discovery, Tulane University School of Medicine , 1430 Tulane Ave, New Orleans, LA 70112
8 shared publications - Hadi Younes
Tulane Research Innovation for Arrhythmia Discovery, Tulane University School of Medicine New Orleans Louisiana USA
7 shared publications
Latest Publications
- 1 November 2026
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 19 (11)
Reclassifying Single Lead Sinus Rhythm ECGs for Improved AF Recurrence Detection With Deep Learning
BACKGROUND: Atrial fibrillation (AF) remains a common outcome after catheter ablation, with recurrence observed in up to 50% of patients within 5 years. Despite extensive research, challenges remain in optimizing observation and prediction windows for AF recurrence assessment. Therefore, we developed and validated a novel deep learning model that reclassifies sinus rhythm based on past and future AF events using single-lead ECG strips from handheld devices. METHODS: Of the 558 participants, 308 with no documented recurrence during study follow-up contributed Benign Sinus strips, while 250 with documented recurrence contributed sinus rhythm strips recorded within ±3 days of an AF event, defined as Severe Sinus strips. Both clinical feature-based models and a deep learning model were used to classify these ECGs according to their proximity to AF recurrence events. Performance was evaluated using area under the receiver operating characteristic curve, accuracy, sensitivity, specificity, and F1-score. RESULTS: The strip-level pretrained deep learning model achieved an area under the receiver operating characteristic curve of 0.86, with sensitivity of 0.79, and specificity of 0.76. The complementary participant-level clinical feature-based Random Forest benchmark achieved an area under the receiver operating characteristic curve of 0.71, sensitivity of 0.58, and specificity of 0.69. Feature-based analyses identified associations involving heart-rate variability, mean R–R interval, female sex, left atrial volume, and mean P-wave duration. CONCLUSIONS: Our dynamic deep learning model reclassifies 30-second single-lead sinus rhythm ECGs based on AF events within ±3 days, transforming a brief ECG snapshot into a summarized indicator of short-term AF risk.
- 1 November 2026
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 19 (11)
Reclassifying Single Lead Sinus Rhythm ECGs for Improved AF Recurrence Detection With Deep Learning
BACKGROUND: Atrial fibrillation (AF) remains a common outcome after catheter ablation, with recurrence observed in up to 50% of patients within 5 years. Despite extensive research, challenges remain in optimizing observation and prediction windows for AF recurrence assessment. Therefore, we developed and validated a novel deep learning model that reclassifies sinus rhythm based on past and future AF events using single-lead ECG strips from handheld devices. METHODS: Of the 558 participants, 308 with no documented recurrence during study follow-up contributed Benign Sinus strips, while 250 with documented recurrence contributed sinus rhythm strips recorded within ±3 days of an AF event, defined as Severe Sinus strips. Both clinical feature-based models and a deep learning model were used to classify these ECGs according to their proximity to AF recurrence events. Performance was evaluated using area under the receiver operating characteristic curve, accuracy, sensitivity, specificity, and F1-score. RESULTS: The strip-level pretrained deep learning model achieved an area under the receiver operating characteristic curve of 0.86, with sensitivity of 0.79, and specificity of 0.76. The complementary participant-level clinical feature-based Random Forest benchmark achieved an area under the receiver operating characteristic curve of 0.71, sensitivity of 0.58, and specificity of 0.69. Feature-based analyses identified associations involving heart-rate variability, mean R–R interval, female sex, left atrial volume, and mean P-wave duration. CONCLUSIONS: Our dynamic deep learning model reclassifies 30-second single-lead sinus rhythm ECGs based on AF events within ±3 days, transforming a brief ECG snapshot into a summarized indicator of short-term AF risk.
- Open Access
- 29 July 2026
- Published by Oxford University Press (OUP) in European Heart Journal - Digital Health
- Vol. 7 (7)
Health Electronic Assessment of Risks and Trends using Biometric Equipment and Technology (HEARTBEAT): study design and rationale
Aims: Cardiovascular disease remains the leading driver of morbidity and mortality worldwide. As consumer smartwatches become ubiquitous, they offer a practical platform for continuous, real-world phenotyping, capturing passive and active biometrics that may detect occult disease and anticipate adverse cardiovascular events. Scaled deployment of these devices could enable remote screening, longitudinal monitoring, and earlier risk mitigation beyond traditional episodic care. Methods and results: The Health Electronic Assessment of Risks and Trends using Biometric Equipment and Technology (HEARTBEAT) study is a prospective, single-arm wearable study that has enrolled 897 participants since 10 October 2024. The primary objectives are to: (1) define associations between smartwatch-derived biometrics and incident cardiovascular events; (2) derive biometric profiles that support identification of underlying cardiometabolic and cardiovascular conditions; and (3) apply artificial intelligence to improve prediction of cardiovascular events. Participants are screened, consented, and enrolled in person or remotely. Data are captured through electronic medical record (EMR) extraction and a companion smartphone application. Participants are followed for 12 months, with outcomes adjudicated on an ongoing basis using EMR review and app-based surveys. Conclusion: The HEARTBEAT study will test whether scalable, consumer-grade wearables can move from wellness tracking to clinically meaningful signal, identifying comorbidities and predicting adverse cardiovascular outcomes in routine care settings. If successful, the study will help establish an evidence base for smartwatches as validated digital health tools for remote screening and continuous cardiovascular monitoring.
- 29 July 2026
- Published by Oxford University Press (OUP) in European Heart Journal - Digital Health
- Vol. 7 (7)
Open AccessHealth Electronic Assessment of Risks and Trends using Biometric Equipment and Technology (HEARTBEAT): study design and rationale
Aims: Cardiovascular disease remains the leading driver of morbidity and mortality worldwide. As consumer smartwatches become ubiquitous, they offer a practical platform for continuous, real-world phenotyping, capturing passive and active biometrics that may detect occult disease and anticipate adverse cardiovascular events. Scaled deployment of these devices could enable remote screening, longitudinal monitoring, and earlier risk mitigation beyond traditional episodic care. Methods and results: The Health Electronic Assessment of Risks and Trends using Biometric Equipment and Technology (HEARTBEAT) study is a prospective, single-arm wearable study that has enrolled 897 participants since 10 October 2024. The primary objectives are to: (1) define associations between smartwatch-derived biometrics and incident cardiovascular events; (2) derive biometric profiles that support identification of underlying cardiometabolic and cardiovascular conditions; and (3) apply artificial intelligence to improve prediction of cardiovascular events. Participants are screened, consented, and enrolled in person or remotely. Data are captured through electronic medical record (EMR) extraction and a companion smartphone application. Participants are followed for 12 months, with outcomes adjudicated on an ongoing basis using EMR review and app-based surveys. Conclusion: The HEARTBEAT study will test whether scalable, consumer-grade wearables can move from wellness tracking to clinically meaningful signal, identifying comorbidities and predicting adverse cardiovascular outcomes in routine care settings. If successful, the study will help establish an evidence base for smartwatches as validated digital health tools for remote screening and continuous cardiovascular monitoring.
- Open Access
- 11 February 2026
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 28, e93347
Gastrointestinal Bleeding Risk Associated With Pulse Pressure in Patients With Atrial Fibrillation: A Retrospective Cohort Study (Preprint)
Background: Patients with atrial fibrillation (AF) face significant bleeding risks, particularly those receiving oral anticoagulation; however, existing risk scores such as HAS-BLED and ORBIT demonstrate limited predictive accuracy. Pulse pressure (PP), calculated as the difference between systolic blood pressure (SBP) and diastolic blood pressure, is a noninvasive marker of arterial stiffness that has been associated with cardiovascular outcomes. However, PP has not been evaluated as a predictor of bleeding in this population. Objective: This study evaluated whether elevated PP independently predicts major bleeding events, overall and by subtype, in patients with AF after adjusting for established clinical risk factors. Methods: We conducted a retrospective cohort study using electronic health records from REACHnet, a PCORnet-affiliated clinical data network in Louisiana. A total of 4935 adults (mean age 63.7, SD 11.0 y; n=1606, 32.5% female) with AF between 2010 and 2019 were included via consecutive sampling of all eligible patients. PP was derived from outpatient blood pressure measurements closest to AF diagnosis and analyzed in tertiles (low: 62 mm Hg) and continuously per 10 mm Hg. The primary outcome was time to the first bleeding event, a composite of gastrointestinal bleeding, intracranial hemorrhage, and other clinically significant bleeding, identified using ICD-9 / ICD-10 codes. Kaplan-Meier survival curves with log-rank testing were used for univariable analysis. Multivariable Cox proportional hazards regression was adjusted for age, sex, race, comorbidities, medications, and the ORBIT score. A sensitivity analysis applied multivariable logistic regression additionally incorporating SBP. Statistical significance was set at P <.05. Results: Over a 5-year follow-up, 677 out of 4935 (13.7%) patients experienced a bleeding event (intracranial hemorrhage: n=60, 1.2%; gastrointestinal bleeding: n=195, 4.0%; and other bleeding: n=149, 3.0%). Gastrointestinal bleeding differed significantly across PP tertiles ( P= .007). Kaplan-Meier analysis confirmed lower gastrointestinal bleeding-free survival in the highest tertile (log-rank P= .004). No significant differences were observed for intracranial ( P= .08), other ( P =.58), or composite bleeding ( P =.22). In multivariable Cox regression, each 1 mm Hg increase in PP was independently associated with a 1.4% higher gastrointestinal bleeding risk (hazard ratio 1.014, 95% CI 1.001‐1.028; P= .04), approximately 15% per 10 mm Hg. This remained significant after adjusting for SBP and ORBIT score (odds ratio 1.013/mm Hg, 95% CI 1.001‐1.025; P =.03), while SBP was not independently significant ( P =.13). Conclusions: PP independently predicts gastrointestinal bleeding risk in patients with AF beyond established clinical risk factors and validated bleeding risk scores. Unlike prior investigations that examined SBP or diastolic blood pressure components in isolation, this is the first study to identify PP as a predictor of gastrointestinal bleeding in this population. As a readily available, low-cost hemodynamic parameter derived from routine clinical measurements, PP could enhance existing risk stratification tools and inform more personalized bleeding risk management strategies in patients with AF.
- 11 February 2026
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 28, e93347
Open AccessGastrointestinal Bleeding Risk Associated With Pulse Pressure in Patients With Atrial Fibrillation: A Retrospective Cohort Study (Preprint)
Background: Patients with atrial fibrillation (AF) face significant bleeding risks, particularly those receiving oral anticoagulation; however, existing risk scores such as HAS-BLED and ORBIT demonstrate limited predictive accuracy. Pulse pressure (PP), calculated as the difference between systolic blood pressure (SBP) and diastolic blood pressure, is a noninvasive marker of arterial stiffness that has been associated with cardiovascular outcomes. However, PP has not been evaluated as a predictor of bleeding in this population. Objective: This study evaluated whether elevated PP independently predicts major bleeding events, overall and by subtype, in patients with AF after adjusting for established clinical risk factors. Methods: We conducted a retrospective cohort study using electronic health records from REACHnet, a PCORnet-affiliated clinical data network in Louisiana. A total of 4935 adults (mean age 63.7, SD 11.0 y; n=1606, 32.5% female) with AF between 2010 and 2019 were included via consecutive sampling of all eligible patients. PP was derived from outpatient blood pressure measurements closest to AF diagnosis and analyzed in tertiles (low: 62 mm Hg) and continuously per 10 mm Hg. The primary outcome was time to the first bleeding event, a composite of gastrointestinal bleeding, intracranial hemorrhage, and other clinically significant bleeding, identified using ICD-9 / ICD-10 codes. Kaplan-Meier survival curves with log-rank testing were used for univariable analysis. Multivariable Cox proportional hazards regression was adjusted for age, sex, race, comorbidities, medications, and the ORBIT score. A sensitivity analysis applied multivariable logistic regression additionally incorporating SBP. Statistical significance was set at P <.05. Results: Over a 5-year follow-up, 677 out of 4935 (13.7%) patients experienced a bleeding event (intracranial hemorrhage: n=60, 1.2%; gastrointestinal bleeding: n=195, 4.0%; and other bleeding: n=149, 3.0%). Gastrointestinal bleeding differed significantly across PP tertiles ( P= .007). Kaplan-Meier analysis confirmed lower gastrointestinal bleeding-free survival in the highest tertile (log-rank P= .004). No significant differences were observed for intracranial ( P= .08), other ( P =.58), or composite bleeding ( P =.22). In multivariable Cox regression, each 1 mm Hg increase in PP was independently associated with a 1.4% higher gastrointestinal bleeding risk (hazard ratio 1.014, 95% CI 1.001‐1.028; P= .04), approximately 15% per 10 mm Hg. This remained significant after adjusting for SBP and ORBIT score (odds ratio 1.013/mm Hg, 95% CI 1.001‐1.025; P =.03), while SBP was not independently significant ( P =.13). Conclusions: PP independently predicts gastrointestinal bleeding risk in patients with AF beyond established clinical risk factors and validated bleeding risk scores. Unlike prior investigations that examined SBP or diastolic blood pressure components in isolation, this is the first study to identify PP as a predictor of gastrointestinal bleeding in this population. As a readily available, low-cost hemodynamic parameter derived from routine clinical measurements, PP could enhance existing risk stratification tools and inform more personalized bleeding risk management strategies in patients with AF.
- Open Access
Prediction of Stroke Risk in Patients with Atrial Fibrillation: Comorbidities vs Temporal AF Behavior
Background: There are controversies about whether atrial fibrillation (AF) type, paroxysmal (PaAF) vs persistent (PeAF), affects stroke risk. The type of AF is still not included in most risk stratification tools. Objective: We aim to assess differences in stroke outcomes between PaAF and PeAF patients in both low- and high-CHA 2 DS 2 -VASc groups. Methods: We conducted an epidemiological study of all patients admitted to Tulane Medical Center with the diagnosis of AF from January 2010 to March 2020. Data were extracted from the regional US electronic medical records database, Research Action for Health Network (REACHnet), for all patients aged 18 years or older with a diagnosis of AF. Patients were divided into four groups: a low CHA 2 DS 2 -VASc score was defined as CHA 2 DS 2 -VASc < 2 in women and CHA 2 DS 2 -VASc < 1 in men. PeAF was defined as a patient with at least one episode of AF lasting 7 days or more. PaAF was defined as a patient with AF with no episode lasting more than 7 days. The outcome of the study was an ischemic stroke event or a transient ischemic attack that occurred after the diagnosis of AF. Kaplan-Meier curves and the log-rank test were used to compare the study outcomes across all four groups. Multivariable Cox regression was performed to adjust for the use of anticoagulants. Results: A total of 1,079 patients were included in the study. 576 patients had PaAF and high CHA 2 DS 2 -VASc, 215 had PaAF and low CHA 2 DS 2 -VASc, 214 had PeAF and high CHA 2 DS 2 -VASc, and 74 patients were PeAF, and low CHA 2 DS 2 -VASc. Patients were followed up over 5 years. Based on the Log-rank test, there were significant differences among the four groups (p < 0.001). After adjusting for anticoagulants, patients with high CHA 2 DS 2 -VASc appeared to have more strokes on follow-up than patients with low CHA 2 DS 2 -VASc, independent of AF type and anticoagulation prescription. For the Cox model, when the PaAF High CHA 2 DS 2 -VASc group was used as the reference, both low CHA 2 DS 2 -VASc groups, PaAF (0.032 [0.012–0.081], p < 0.001) and PeAF (0.032 [0.008–0.135], p < 0.001), had a lower risk of stroke. However, there was no difference in stroke when the reference group was compared to high CHA 2 DS 2 -VASc, PeAF (1.169 [0.866 – 1.576], p=0.308). Conclusion: In our database, the CHA 2 DS 2 -VASc score remained superior to the type of AF when predicting stroke outcome. Type of AF did not affect stroke outcome even after adjusting for CHA 2 DS 2 -VASc and for anticoagulation prescription.
Open AccessPrediction of Stroke Risk in Patients with Atrial Fibrillation: Comorbidities vs Temporal AF Behavior
Background: There are controversies about whether atrial fibrillation (AF) type, paroxysmal (PaAF) vs persistent (PeAF), affects stroke risk. The type of AF is still not included in most risk stratification tools. Objective: We aim to assess differences in stroke outcomes between PaAF and PeAF patients in both low- and high-CHA 2 DS 2 -VASc groups. Methods: We conducted an epidemiological study of all patients admitted to Tulane Medical Center with the diagnosis of AF from January 2010 to March 2020. Data were extracted from the regional US electronic medical records database, Research Action for Health Network (REACHnet), for all patients aged 18 years or older with a diagnosis of AF. Patients were divided into four groups: a low CHA 2 DS 2 -VASc score was defined as CHA 2 DS 2 -VASc < 2 in women and CHA 2 DS 2 -VASc < 1 in men. PeAF was defined as a patient with at least one episode of AF lasting 7 days or more. PaAF was defined as a patient with AF with no episode lasting more than 7 days. The outcome of the study was an ischemic stroke event or a transient ischemic attack that occurred after the diagnosis of AF. Kaplan-Meier curves and the log-rank test were used to compare the study outcomes across all four groups. Multivariable Cox regression was performed to adjust for the use of anticoagulants. Results: A total of 1,079 patients were included in the study. 576 patients had PaAF and high CHA 2 DS 2 -VASc, 215 had PaAF and low CHA 2 DS 2 -VASc, 214 had PeAF and high CHA 2 DS 2 -VASc, and 74 patients were PeAF, and low CHA 2 DS 2 -VASc. Patients were followed up over 5 years. Based on the Log-rank test, there were significant differences among the four groups (p < 0.001). After adjusting for anticoagulants, patients with high CHA 2 DS 2 -VASc appeared to have more strokes on follow-up than patients with low CHA 2 DS 2 -VASc, independent of AF type and anticoagulation prescription. For the Cox model, when the PaAF High CHA 2 DS 2 -VASc group was used as the reference, both low CHA 2 DS 2 -VASc groups, PaAF (0.032 [0.012–0.081], p < 0.001) and PeAF (0.032 [0.008–0.135], p < 0.001), had a lower risk of stroke. However, there was no difference in stroke when the reference group was compared to high CHA 2 DS 2 -VASc, PeAF (1.169 [0.866 – 1.576], p=0.308). Conclusion: In our database, the CHA 2 DS 2 -VASc score remained superior to the type of AF when predicting stroke outcome. Type of AF did not affect stroke outcome even after adjusting for CHA 2 DS 2 -VASc and for anticoagulation prescription.
- 19 September 2025
- Published by Springer Nature
- p. 500-509
SOFA: Deep Learning Framework for Simulating and Optimizing Atrial Fibrillation Ablation
- 19 September 2025
- Published by Springer Nature
- p. 500-509
SOFA: Deep Learning Framework for Simulating and Optimizing Atrial Fibrillation Ablation
- Open Access
SOFA: Deep Learning Framework for Simulating and Optimizing Atrial Fibrillation Ablation
Atrial fibrillation (AF) is a prevalent cardiac arrhythmia often treated with catheter ablation procedures, but procedural outcomes are highly variable. Evaluating and improving ablation efficacy is challenging due to the complex interaction between patient-specific tissue and procedural factors. This paper asks two questions: Can AF recurrence be predicted by simulating the effects of procedural parameters? How should we ablate to reduce AF recurrence? We propose SOFA (Simulating and Optimizing Atrial Fibrillation Ablation), a novel deep-learning framework that addresses these questions. SOFA first simulates the outcome of an ablation strategy by generating a post-ablation image depicting scar formation, conditioned on a patient's pre-ablation LGE-MRI and the specific procedural parameters used (e.g., ablation locations, duration, temperature, power, and force). During this simulation, it predicts AF recurrence risk. Critically, SOFA then introduces an optimization scheme that refines these procedural parameters to minimize the predicted risk. Our method leverages a multi-modal, multi-view generator that processes 2.5D representations of the atrium. Quantitative evaluations show that SOFA accurately synthesizes post-ablation images and that our optimization scheme leads to a 22.18\% reduction in the model-predicted recurrence risk. To the best of our knowledge, SOFA is the first framework to integrate the simulation of procedural effects, recurrence prediction, and parameter optimization, offering a novel tool for personalizing AF ablation.
Open AccessSOFA: Deep Learning Framework for Simulating and Optimizing Atrial Fibrillation Ablation
Atrial fibrillation (AF) is a prevalent cardiac arrhythmia often treated with catheter ablation procedures, but procedural outcomes are highly variable. Evaluating and improving ablation efficacy is challenging due to the complex interaction between patient-specific tissue and procedural factors. This paper asks two questions: Can AF recurrence be predicted by simulating the effects of procedural parameters? How should we ablate to reduce AF recurrence? We propose SOFA (Simulating and Optimizing Atrial Fibrillation Ablation), a novel deep-learning framework that addresses these questions. SOFA first simulates the outcome of an ablation strategy by generating a post-ablation image depicting scar formation, conditioned on a patient's pre-ablation LGE-MRI and the specific procedural parameters used (e.g., ablation locations, duration, temperature, power, and force). During this simulation, it predicts AF recurrence risk. Critically, SOFA then introduces an optimization scheme that refines these procedural parameters to minimize the predicted risk. Our method leverages a multi-modal, multi-view generator that processes 2.5D representations of the atrium. Quantitative evaluations show that SOFA accurately synthesizes post-ablation images and that our optimization scheme leads to a 22.18\% reduction in the model-predicted recurrence risk. To the best of our knowledge, SOFA is the first framework to integrate the simulation of procedural effects, recurrence prediction, and parameter optimization, offering a novel tool for personalizing AF ablation.
- Open Access
- 22 April 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (5)
Comprehensive atrial fibrillation burden and symptom reduction post-ablation: insights from DECAAF II
Traditional atrial fibrillation (AF) recurrence after catheter ablation is reported as a binary outcome. However, a paradigm shift towards a more granular definition, considering arrhythmic or symptomatic burden, is emerging. We hypothesize that ablation reduces AF burden independently of conventional recurrence status in patients with persistent AF, correlating with symptom burden reduction. Ninety-eight patients with persistent AF from the DECAAF II trial with pre-ablation follow-up were included. Patients recorded daily single-lead electrocardiogram (ECG) strips, defining AF burden as the proportion of AF days among total submitted ECG days. The primary outcome was atrial arrhythmia recurrence. The AF severity scale was administered pre-ablation and at 12 months post-ablation. At follow-up, 69 patients had atrial arrhythmia recurrence and 29 remained in sinus rhythm. These patients were categorized into a recurrence (n = 69) and a no-recurrence group (n = 29). Both groups had similar baseline characteristics, but recurrence patients were older (P = 0.005), had a higher prevalence of hyperlipidaemia (P = 0.007), and had a larger left atrial (LA) volume (P = 0.01). There was a reduction in AF burden in the recurrence group when compared with their pre-ablation burden (65 vs. 15%, P < 0.0001). Utah Stage 4 fibrosis and diabetes predicted less improvement in AF burden. The symptom severity score at 12 months post-ablation was significantly reduced compared with the pre-ablation score in the recurrence group, and there was a significant correlation between the reduction in symptom severity score and the reduction in AF burden (R = 0.39, P = 0.001). Catheter ablation reduces AF burden, irrespective of arrhythmia recurrence post-procedure. There is a strong correlation between AF burden reduction and symptom improvement post-ablation. Notably, elevated LA fibrosis impedes AF burden decrease following catheter ablation.
- 22 April 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (5)
Open AccessComprehensive atrial fibrillation burden and symptom reduction post-ablation: insights from DECAAF II
Traditional atrial fibrillation (AF) recurrence after catheter ablation is reported as a binary outcome. However, a paradigm shift towards a more granular definition, considering arrhythmic or symptomatic burden, is emerging. We hypothesize that ablation reduces AF burden independently of conventional recurrence status in patients with persistent AF, correlating with symptom burden reduction. Ninety-eight patients with persistent AF from the DECAAF II trial with pre-ablation follow-up were included. Patients recorded daily single-lead electrocardiogram (ECG) strips, defining AF burden as the proportion of AF days among total submitted ECG days. The primary outcome was atrial arrhythmia recurrence. The AF severity scale was administered pre-ablation and at 12 months post-ablation. At follow-up, 69 patients had atrial arrhythmia recurrence and 29 remained in sinus rhythm. These patients were categorized into a recurrence (n = 69) and a no-recurrence group (n = 29). Both groups had similar baseline characteristics, but recurrence patients were older (P = 0.005), had a higher prevalence of hyperlipidaemia (P = 0.007), and had a larger left atrial (LA) volume (P = 0.01). There was a reduction in AF burden in the recurrence group when compared with their pre-ablation burden (65 vs. 15%, P < 0.0001). Utah Stage 4 fibrosis and diabetes predicted less improvement in AF burden. The symptom severity score at 12 months post-ablation was significantly reduced compared with the pre-ablation score in the recurrence group, and there was a significant correlation between the reduction in symptom severity score and the reduction in AF burden (R = 0.39, P = 0.001). Catheter ablation reduces AF burden, irrespective of arrhythmia recurrence post-procedure. There is a strong correlation between AF burden reduction and symptom improvement post-ablation. Notably, elevated LA fibrosis impedes AF burden decrease following catheter ablation.
- 8 October 2023
- Published by Springer Nature
- p. 106-116
FBA-Net: Foreground and Background Aware Contrastive Learning for Semi-Supervised Atrium Segmentation
- 8 October 2023
- Published by Springer Nature
- p. 106-116
FBA-Net: Foreground and Background Aware Contrastive Learning for Semi-Supervised Atrium Segmentation
- 1 October 2023
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 16 (10) , e011975
Comparison of Ablation Strategies for Persistent Atrial Fibrillation: A Post Hoc Analysis of the DECAAF II Study
- 1 October 2023
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 16 (10) , e011975
Comparison of Ablation Strategies for Persistent Atrial Fibrillation: A Post Hoc Analysis of the DECAAF II Study
- Open Access
FBA-Net: Foreground and Background Aware Contrastive Learning for Semi-Supervised Atrium Segmentation
Medical image segmentation of gadolinium enhancement magnetic resonance imaging (GE MRI) is an important task in clinical applications. However, manual annotation is time-consuming and requires specialized expertise. Semi-supervised segmentation methods that leverage both labeled and unlabeled data have shown promise, with contrastive learning emerging as a particularly effective approach. In this paper, we propose a contrastive learning strategy of foreground and background representations for semi-supervised 3D medical image segmentation (FBA-Net). Specifically, we leverage the contrastive loss to learn representations of both the foreground and background regions in the images. By training the network to distinguish between foreground-background pairs, we aim to learn a representation that can effectively capture the anatomical structures of interest. Experiments on three medical segmentation datasets demonstrate state-of-the-art performance. Notably, our method achieves a Dice score of 91.31% with only 20% labeled data, which is remarkably close to the 91.62% score of the fully supervised method that uses 100% labeled data on the left atrium dataset. Our framework has the potential to advance the field of semi-supervised 3D medical image segmentation and enable more efficient and accurate analysis of medical images with a limited amount of annotated labels.
Open AccessFBA-Net: Foreground and Background Aware Contrastive Learning for Semi-Supervised Atrium Segmentation
Medical image segmentation of gadolinium enhancement magnetic resonance imaging (GE MRI) is an important task in clinical applications. However, manual annotation is time-consuming and requires specialized expertise. Semi-supervised segmentation methods that leverage both labeled and unlabeled data have shown promise, with contrastive learning emerging as a particularly effective approach. In this paper, we propose a contrastive learning strategy of foreground and background representations for semi-supervised 3D medical image segmentation (FBA-Net). Specifically, we leverage the contrastive loss to learn representations of both the foreground and background regions in the images. By training the network to distinguish between foreground-background pairs, we aim to learn a representation that can effectively capture the anatomical structures of interest. Experiments on three medical segmentation datasets demonstrate state-of-the-art performance. Notably, our method achieves a Dice score of 91.31% with only 20% labeled data, which is remarkably close to the 91.62% score of the fully supervised method that uses 100% labeled data on the left atrium dataset. Our framework has the potential to advance the field of semi-supervised 3D medical image segmentation and enable more efficient and accurate analysis of medical images with a limited amount of annotated labels.