Yazdan Salimi

Yazdan Salimi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yazdan Salimi has a total of 67 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Reconstruction-informed and multidomain deep learning for generalizable CT-free attenuation correction in SPECT myocardial perfusion imaging

    by Ghasem Hajianfar, Yazdan Salimi, Mehdi Amini, Xiaotong Hong, René Nkoulou, Elnaz Jenabi, Zahra Mansouri, Atena Aghaee, Soroush Bagheri, Amirhossein Sanaat, et al.


  • Open Access

    Image reconstruction and elongation artifact reduction for a dual‐panel dedicated prostate PET scanner

    by Abdollah Saberi Manesh, Mehdi Amini, Yazdan Salimi, Katayoun Doroud, Crispin Williams, Themistoklis Williams, Hossein Arabi, Habib Zaidi

    Background: The development of PET scanners dedicated to high temporal and spatial resolution organ‐specific imaging is an active research area, motivated by the need for cost reduction, improved lesion detectability and quantification in specific clinical scenarios, as well as by ongoing hardware and software innovations. Purpose: This study investigates and compares various image reconstruction strategies for a dual‐panel prostate‐dedicated PET scanner (ProVision), which features four‐layered dual‐readout time‐of‐flight depth‐of‐interaction detectors and a 22‐position acquisition protocol to improve angular coverage. Materials and methods: A list‐mode MLEM algorithm with multi‐ray modeling was developed and optimized using a scaled NEMA image quality phantom to determine optimal number of rays and iterations. These parameters were then used to reconstruct data from both simulation and experimental acquisitions, including an anthropomorphic pelvis phantom, named Adam‐PETer. Four reconstruction approaches were evaluated: classical MLEM; MLEM with embedded shift‐variant point spread function (PSF) modeling; a hybrid list‐mode reconstruction; and a Swin‐UNETR‐based deep learning model applied as a post‐reconstruction enhancement to MLEM images. Performance was assessed using contrast recovery coefficient (CRC), contrast‐to‐noise ratio (CNR), and contrast‐to‐noise consistency (CNC), on both a scaled NEMA phantom and an experimental anthropomorphic phantom. Results: In the scaled NEMA phantom simulation, the Swin‐based method yielded the highest CNR and CNC, especially for the smallest spheres, thereby outperforming both standard MLEM and the hybrid algorithm. In the Adam‐PETer experimental prostate phantom, the CNR was 10.43 for MLEM, 14.48 for Hybrid, and 13.85 for Swin for the larger lesion (10 mm). The CNR values were 2.28, 3.03, and 4.35, respectively, for the smaller lesion (8 mm). CNC values also varied across methods, with Swin achieving the best result for the smaller lesion. These findings indicate that model‐based and learned methods offer complementary strengths depending on lesion contrast and size. Conclusion: The PET scanner‐adapted reconstruction combined with deep learning refinement improves image quality in dedicated, limited‐angle PET systems.


  • Open Access

    Effective dose and risk assessment in 18F-FDG PET/CT examinations of lymphoma patients using updated dose coefficients

    by Forough Jafarian-Dehkordi, Yazdan Salimi, Esmail Jafari, Majid Assadi, Christoph Hoeschen

  • Open Access

    MetaPredictomics

    by Mehdi Amini, Ghasem Hajianfar, Yazdan Salimi, Zahra Mansouri, Habib Zaidi

    Background: Non–small cell lung cancer (NSCLC) is a complex disease characterized by diverse clinical, genetic, and histopathologic traits, necessitating personalized treatment approaches. While numerous biomarkers have been introduced for NSCLC prognostication, no single source of information can provide a comprehensive understanding of the disease. However, integrating biomarkers from multiple sources may offer a holistic view of the disease, enabling more accurate predictions. In this study, we present MetaPredictomics, a framework that integrates clinicopathologic data with PET/CT radiomics from the primary tumor and presumed healthy organs (referred to as “organomics”) to predict postsurgical recurrence. Patients and Methods: A fully automated deep learning-based segmentation model was employed to delineate 19 affected (whole lung and the affected lobe) and presumed healthy organs from CT images of the presurgical PET/CT scans of 145 NSCLC patients sourced from a publicly available data set. Using PyRadiomics, 214 features (107 from CT, 107 from PET) were extracted from the gross tumor volume (GTV) and each segmented organ. In addition, a clinicopathologic feature set was constructed, incorporating clinical characteristics, histopathologic data, gene mutation status, conventional PET imaging biomarkers, and patients’ treatment history. GTV Radiomics, each of the organomics, and the clinicopathologic feature sets were each fed to a time-to-event prediction machine, based on glmboost, to establish first-level models. The risk scores obtained from the first-level models were then used as inputs for meta models developed using a stacked ensemble approach. Questing optimized performance, we assessed meta models established upon all combinations of first-level models with concordance index (C-index) ≥0.6. The performance of all the models was evaluated using the average C-index across a unique 3-fold cross-validation scheme for fair comparison. Results: The clinicopathologic model outperformed other first-level models with a C-index of 0.67, followed closely by GTV radiomics model with C-index of 0.65. Among the organomics models, whole-lung and aorta models achieved top performance with a C-index of 0.65, while 12 organomics models achieved C-indices of ≥0.6. Meta models significantly outperformed the first-level models with the top 100 achieving C-indices between 0.703 and 0.731. The clinicopathologic, whole lung, esophagus, pancreas, and GTV models were the most frequently present models in the top 100 meta models with frequencies of 98, 71, 69, 62, and 61, respectively. Conclusions: In this study, we highlighted the value of maximizing the use of medical imaging for NSCLC recurrence prognostication by incorporating data from various organs, rather than focusing solely on the tumor and its immediate surroundings. This multisource integration proved particularly beneficial in the meta models, where combining clinicopathologic data with tumor radiomics and organomics models significantly enhanced recurrence prediction.


  • Open Access

    Deep Learning–Powered CT-Less Multitracer Organ Segmentation From PET Images

    by Yazdan Msc Salimi, Zahra Msc Mansouri, Isaac Shiri, Ismini Mainta, Habib Zaidi

    Purpose: The common approach for organ segmentation in hybrid imaging relies on coregistered CT (CTAC) images. This method, however, presents several limitations in real clinical workflows where mismatch between PET and CT images are very common. Moreover, low-dose CTAC images have poor quality, thus challenging the segmentation task. Recent advances in CT-less PET imaging further highlight the necessity for an effective PET organ segmentation pipeline that does not rely on CT images. Therefore, the goal of this study was to develop a CT-less multitracer PET segmentation framework. Patients and Methods: We collected 2062 PET/CT images from multiple scanners. The patients were injected with either 18F-FDG (1487) or 68Ga-PSMA (575). PET/CT images with any kind of mismatch between PET and CT images were detected through visual assessment and excluded from our study. Multiple organs were delineated on CT components using previously trained in-house developed nnU-Net models. The segmentation masks were resampled to coregistered PET images and used to train 4 different deep learning models using different images as input, including noncorrected PET (PET-NC) and attenuation and scatter-corrected PET (PET-ASC) for 18F-FDG (tasks 1 and 2, respectively using 22 organs) and PET-NC and PET-ASC for 68Ga tracers (tasks 3 and 4, respectively, using 15 organs). The models’ performance was evaluated in terms of Dice coefficient, Jaccard index, and segment volume difference. Results: The average Dice coefficient over all organs was 0.81 ± 0.15, 0.82 ± 0.14, 0.77 ± 0.17, and 0.79 ± 0.16 for tasks 1, 2, 3, and 4, respectively. PET-ASC models outperformed PET-NC models (P < 0.05) for most of organs. The highest Dice values were achieved for the brain (0.93 to 0.96 in all 4 tasks), whereas the lowest values were achieved for small organs, such as the adrenal glands. The trained models showed robust performance on dynamic noisy images as well. Conclusions: Deep learning models allow high-performance multiorgan segmentation for 2 popular PET tracers without the use of CT information. These models may tackle the limitations of using CT segmentation in PET/CT image quantification, kinetic modeling, radiomics analysis, dosimetry, or any other tasks that require organ segmentation masks.


  • Open Access

    Tracer-Separator

    by Amirhossein Sanaat, Yiyi Msc Hu, Cecilia Boccalini, Yazdan Msc Salimi, Zahra Msc Mansouri, Eliluane Pirazzo Andrade Teixeira, Gregory Mathoux, Valentina Garibotto, Habib Zaidi

    Introduction: Multiplexed PET imaging revolutionized clinical decision-making by simultaneously capturing various radiotracer data in a single scan, enhancing diagnostic accuracy and patient comfort. Through a transformer-based deep learning, this study underscores the potential of advanced imaging techniques to streamline diagnosis and improve patient outcomes. Patients and Methods: The research cohort consisted of 120 patients spanning from cognitively unimpaired individuals to those with mild cognitive impairment, dementia, and other mental disorders. Patients underwent various imaging assessments, including 3D T1-weighted MRI, amyloid PET scans using either 18F-florbetapir (FBP) or 18F-flutemetamol (FMM), and 18F-FDG PET. Summed images of FMM/FBP and FDG were used as proxy for simultaneous scanning of 2 different tracers. A SwinUNETR model, a convolution-free transformer architecture, was trained for image translation. The model was trained using mean square error loss function and 5-fold cross-validation. Visual evaluation involved assessing image similarity and amyloid status, comparing synthesized images with actual ones. Statistical analysis was conducted to determine the significance of differences. Results: Visual inspection of synthesized images revealed remarkable similarity to reference images across various clinical statuses. The mean centiloid bias for dementia, mild cognitive impairment, and healthy control subjects and for FBP tracers is 15.70 ± 29.78, 0.35 ± 33.68, and 6.52 ± 25.19, respectively, whereas for FMM, it is −6.85 ± 25.02, 4.23 ± 23.78, and 5.71 ± 21.72, respectively. Clinical evaluation by 2 readers further confirmed the model's efficiency, with 97 FBP/FMM and 63 FDG synthesized images (from 120 subjects) found similar to ground truth diagnoses (rank 3), whereas 3 FBP/FMM and 15 FDG synthesized images were considered nonsimilar (rank 1). Promising sensitivity, specificity, and accuracy were achieved in amyloid status assessment based on synthesized images, with an average sensitivity of 95 ± 2.5, specificity of 72.5 ± 12.5, and accuracy of 87.5 ± 2.5. Error distribution analyses provided valuable insights into error levels across brain regions, with most falling between −0.1 and +0.2 SUV ratio. Correlation analyses demonstrated strong associations between actual and synthesized images, particularly for FMM images (FBP: Y = 0.72X + 20.95, R 2 = 0.54; FMM: Y = 0.65X + 22.77, R 2 = 0.77). Conclusions: This study demonstrated the potential of a novel convolution-free transformer architecture, SwinUNETR, for synthesizing realistic FDG and FBP/FMM images from summation scans mimicking simultaneous dual-tracer imaging.


  • Open Access

    Explainable AI for automated respiratory misalignment detection in PET/CT imaging

    by Yazdan Salimi, Zahra Mansouri, Mehdi Amini, Ismini Mainta, Habib Zaidi

    Purpose. Positron emission tomography (PET) image quality can be affected by artifacts emanating from PET, computed tomography (CT), or artifacts due to misalignment between PET and CT images. Automated detection of misalignment artifacts can be helpful both in data curation and in facilitating clinical workflow. This study aimed to develop an explainable machine learning approach to detect misalignment artifacts in PET/CT imaging. Approach. This study included 1216 PET/CT images. All images were visualized and images with respiratory misalignment artifact (RMA) detected. Using previously trained models, four organs including the lungs, liver, spleen, and heart were delineated on PET and CT images separately. Data were randomly split into cross-validation (80%) and test set (20%), then two segmentations performed on PET and CT images were compared and the comparison metrics used as predictors for a random forest framework in a 10-fold scheme on cross-validation data. The trained models were tested on 20% test set data. The model’s performance was calculated in terms of specificity, sensitivity, F1-Score and area under the curve (AUC). Main results. Sensitivity, specificity, and AUC of 0.82, 0.85, and 0.91 were achieved in ten-fold data split. F1_score, sensitivity, specificity, and AUC of 84.5 vs 82.3, 83.9 vs 83.8, 87.7 vs 83.5, and 93.2 vs 90.1 were achieved for cross-validation vs test set, respectively. The liver and lung were the most important organs selected after feature selection. Significance. We developed an automated pipeline to segment four organs from PET and CT images separately and used the match between these segmentations to decide about the presence of misalignment artifact. This methodology may follow the same logic as a reader detecting misalignment through comparing the contours of organs on PET and CT images. The proposed method can be used to clean large datasets or integrated into a clinical scanner to indicate artifactual cases.


  • Open Access

    Deep Learning-powered CT-less Multi-tracer Organ Segmentation from PET Images: A solution for unreliable CT segmentation in PET/CT Imaging

    by Yazdan Salimi, Zahra Mansouri, Isaac Shiri, Ismini Mainta, Habib Zaidi

    Introduction: The common approach for organ segmentation in hybrid imaging relies on co-registered CT (CTAC) images. This method, however, presents several limitations in real clinical workflows where mismatch between PET and CT images are very common. Moreover, low-dose CTAC images have poor quality, thus challenging the segmentation task. Recent advances in CT-less PET imaging further highlight the necessity for an effective PET organ segmentation pipeline that does not rely on CT images. Therefore, the goal of this study was to develop a CT-less multi-tracer PET segmentation framework. Methods: We collected 2062 PET/CT images from multiple scanners. The patients were injected with either 18 F-FDG (1487) or 68 Ga-PSMA (575). PET/CT images with any kind of mismatch between PET and CT images were detected through visual assessment and excluded from our study. Multiple organs were delineated on CT components using previously trained in-house developed nnU-Net models. The segmentation masks were resampled to co-registered PET images and used to train four different deep-learning models using different images as input, including non-corrected PET (PET-NC) and attenuation and scatter-corrected PET (PET-ASC) for 18 F-FDG (tasks #1 and #2, respectively using 22 organs) and PET-NC and PET-ASC for 68 Ga tracers (tasks #3 and #4, respectively, using 15 organs). The models’ performance was evaluated in terms of Dice coefficient, Jaccard index, and segment volume difference. Results: The average Dice coefficient over all organs was 0.81±0.15, 0.82±0.14, 0.77±0.17, and 0.79±0.16 for tasks #1, #2, #3, and #4, respectively. PET-ASC models outperformed PET-NC models (P-value < 0.05). The highest Dice values were achieved for the brain (0.93 to 0.96 in all four tasks), whereas the lowest values were achieved for small organs, such as the adrenal glands. The trained models showed robust performance on dynamic noisy images as well. Conclusion: Deep learning models allow high performance multi-organ segmentation for two popular PET tracers without the use of CT information. These models may tackle the limitations of using CT segmentation in PET/CT image quantification, kinetic modeling, radiomics analysis, dosimetry, or any other tasks that require organ segmentation masks.


  • Open Access

    An efficient dual-domain deep learning network for sparse-view CT reconstruction

    by Chang Sun, Yazdan Salimi, Neroladaki Angeliki, Sana Boudabbous, Habib Zaidi