SNSeonghyeon Nam

Seonghyeon Nam

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Seonghyeon Nam has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A wearable-to-implant wireless power transfer technology with variation tolerance

    by Seonghyeon Nam, Taewon Seo, Seungwon Yoo, Chanhui Park, Taein Kim, Min Yu, Yesol Kim, Hyejeong Kang, Dahae Yeom, Yeseul Cho, et al.


  • Open Access

    Liquid metal-based stretchable bioelectronic fiber for electrical stimulation and drug delivery in minimally invasive cardiac therapy

    by Chanhui Park, Yesol Kim, Seonghyeon Nam, Hyejeong Kang, Joonho Moon, Ji Hoon Kim, Gi Doo Cha, Seung-Pyo Lee, Sung-Hyuk Sunwoo, Dae-Hyeong Kim

    Cardiovascular diseases, such as ventricular arrhythmias and heart failure, require timely and effective treatment to prevent disease progression and improve patient outcomes. Current therapeutics, including electrical shock and emergent cardiovascular medications, have significantly contributed to managing these conditions. However, due to their systemic side effects, there are ongoing demands for highly effective localized therapies. In this regard, a soft implantable device has been considered for cardiac applications, but invasiveness in their implantation procedure and difficulty in compact integration of multiple functions are unmet challenges. To address these issues, we develop a stretchable, multi-functional fiber designed for emergent cardiac intervention, offering electrogram recording, electrical modulation, and drug therapy directly at the epicardial surface. With temperature-dependent phase shifting properties of the liquid metal inside the fiber, the stiffened fiber can be implanted into the thoracic cavity without invasive surgery. Once implanted, the softened fiber provides multimodal therapies (e.g., chemotherapy and electrical therapy) tailored to the patient's condition. By tuning the delivery parameters based on continuous electrogram recording, effective and urgent cardiac interventions for severe arrhythmias are demonstrated in an in vivo rat model.


  • Open Access

    Stretchable and Shape-Transformable Organohydrogel with Gallium Mesh Frame

    by Mincheol Lee, Youngjin Choi, Young Min Bae, Seonghyeon Nam, Kiyoung Shin

    Shape-memory materials are widely utilized in biomedical devices and tissue engineering, particularly for their ability to undergo predefined shape changes in response to external stimuli. In this study, a shape-transformable organohydrogel was developed by incorporating a gallium mesh into a polyacrylamide/alginate/glycerol matrix. The gallium mesh, which transitions between solid and liquid states at moderate temperatures (~29.8 °C), enhanced the hydrogel’s mechanical properties and enabled shape-memory functionality. The composite organohydrogel exhibited a high elastic modulus of ~900 kPa in the solid gallium state and ~30 kPa in the liquid gallium state, enabling reversible deformation and structural stability. Glycerol improved the hydrogel’s moisture retention, maintaining stretchability and repeated heating and cooling cycles. After multiple cycles of the shape-changing process, the organohydrogel retained its mechanical integrity, achieving shape-fixation and recovery ratios of ~96% and 95%, respectively. This combination of shape-memory functionality, stretchability, and mechanical stability makes this organohydrogel highly suitable for applications in flexible electronics, soft robotics, and biomedical devices, where adaptability and shape retention are essential.


  • Open Access

    Needle‐Like Multifunctional Biphasic Microfiber for Minimally Invasive Implantable Bioelectronics

    by Seonghyeon Nam, Gi Doo Cha, Sung‐Hyuk Sunwoo, Jae Hwan Jeong, Hyejeong Kang, Ok Kyu Park, Kyeong‐Yeon Lee, Seil Oh, Taeghwan Hyeon, Seung Hong Choi, et al.

    Implantable bioelectronics has attracted significant attention in electroceuticals and clinical medicine for precise diagnosis and efficient treatment of target diseases. However, conventional rigid implantable devices face challenges such as poor tissue‐device interface and unavoidable tissue damage during surgical implantation. Despite continuous efforts to utilize various soft materials to address such issues, their practical applications remain limited. Here, a needle‐like stretchable microfiber composed of a phase‐convertible liquid metal (LM) core and a multifunctional nanocomposite shell for minimally invasive soft bioelectronics is reported. The sharp tapered microfiber can be stiffened by freezing akin to a conventional needle to penetrate soft tissue with minimal incision. Once implanted in vivo where the LM melts, unlike conventional stiff needles, it regains soft mechanical properties, which facilitate a seamless tissue‐device interface. The nanocomposite incorporating with functional nanomaterials exhibits both low impedance and the ability to detect physiological pH, providing biosensing and stimulation capabilities. The fluidic LM embedded in the nanocomposite shell enables high stretchability and strain‐insensitive electrical properties. This multifunctional biphasic microfiber conforms to the surfaces of the stomach, muscle, and heart, offering a promising approach for electrophysiological recording, pH sensing, electrical stimulation, and radiofrequency ablation in vivo.


  • Open Access

    Wide-range robust wireless power transfer using heterogeneously coupled and flippable neutrals in parity-time symmetry

    by Hyunwoo Kim, Seungwon Yoo, Hyunwoo Joo, Jongheon Lee, Donggeun An, Seonghyeon Nam, Hyungu Han, Dae-Hyeong Kim, Sanghoek Kim

    Recently, stationary wireless power transfer (WPT) has been widely adopted in commercial devices. However, the current WPT configuration is limited in its operational area and susceptible to operating condition changes, impeding its applications for dynamic environments. To overcome the limitations, we propose a WPT system with laterally aligned neutral elements in parity-time (PT) symmetry, which can widen the operational area with the number of neutrals N . Compared to the conventional multiple-input–single-output WPT, the dimension of system complexity is substantially reduced from R × C N to R N+ 1 because the neutral amplitudes are simply controlled by coupling capacitors. The operational frequency is automatically adjusted to a real eigenvalue of the PT-symmetric system to achieve high voltage gain and efficiency, making the system robust. The performance of the system calculated by the coupled-mode theory was experimentally verified with rigid and flexible types of receivers, confirming its potential in both industrial and biomedical electronics.