Ziliang Wei
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ziliang Wei has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Mang I. Vai
University of Macau
4 shared publications - Sio Hang Pun
State Key Laboratory of Analog and Mixed Signal VLSI, Institute of Microelectronics University of Macau Macau China
4 shared publications - Yueming Gao
College of Physics and Information Engineering, Fuzhou University, Fuzhou 350108, China
3 shared publications - Jiejie Yang
Fuzhou University
2 shared publications - Min Du
College of Physics and Information Engineering, Fuzhou University, Fuzhou, China
2 shared publications - Zhizhang Chen
Dalhousie University
2 shared publications
Latest Publications
- 8 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Antennas and Propagation
- Vol. 72 (12) , 9437-9450
A Reconfigurable Impedance Matching Method for Magnetic Coupling-Based Near-Field Human Body Communication
The interactions of medical devices within the body area network (BAN) have significantly alleviated the pressure on healthcare resources attributed to an aging society. However, the low-power, high-reliability wireless communications among these devices are susceptible to the influence of the human body. This paper exploits the capacitive effects of human tissues to achieve precise and reconfigurable impedance matching in magnetic resonance coupling (MRC) human body communication to minimize the adverse effects of the human body. First, the impact mechanism of the human body on MRC port impedance is analyzed in this paper under the inductive near-field based on the dielectric dispersion of human tissues. This mechanism helps identify the quasistatic magnetic field within MRC, from which the resonance conditions of MRC are derived. A reconfigurable impedance matching method within a broad bandwidth is proposed using these conditions, and experiments on port impedance and transmission characteristics are conducted using an optimized variable parameter coil as the implementation medium. Results demonstrate that the proposed method can precisely tune within a range of 10 MHz under inductive near-field, confirming the reliability of the resonance conditions and matching methodology. After matching, the MRC exhibits only 12.5 dB @13.56 MHz path loss over a 90 cm transmission distance, surpassing other methods by more than 52.8%. The optimized MRC provides an effective technical foundation for narrowband communication schemes of medical devices in the BAN.
- 8 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Antennas and Propagation
- Vol. 72 (12) , 9437-9450
A Reconfigurable Impedance Matching Method for Magnetic Coupling-Based Near-Field Human Body Communication
The interactions of medical devices within the body area network (BAN) have significantly alleviated the pressure on healthcare resources attributed to an aging society. However, the low-power, high-reliability wireless communications among these devices are susceptible to the influence of the human body. This paper exploits the capacitive effects of human tissues to achieve precise and reconfigurable impedance matching in magnetic resonance coupling (MRC) human body communication to minimize the adverse effects of the human body. First, the impact mechanism of the human body on MRC port impedance is analyzed in this paper under the inductive near-field based on the dielectric dispersion of human tissues. This mechanism helps identify the quasistatic magnetic field within MRC, from which the resonance conditions of MRC are derived. A reconfigurable impedance matching method within a broad bandwidth is proposed using these conditions, and experiments on port impedance and transmission characteristics are conducted using an optimized variable parameter coil as the implementation medium. Results demonstrate that the proposed method can precisely tune within a range of 10 MHz under inductive near-field, confirming the reliability of the resonance conditions and matching methodology. After matching, the MRC exhibits only 12.5 dB @13.56 MHz path loss over a 90 cm transmission distance, surpassing other methods by more than 52.8%. The optimized MRC provides an effective technical foundation for narrowband communication schemes of medical devices in the BAN.
- 27 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 8 (2) , 94-101
Field-Circuit Combination Method for Solving the Detuning Problem of Magnetic Resonance Human Body Communication
The technological challenge to realize wearable medical devices is to ensure low power consumption and reliable transmission of communication. Magnetic resonance human body communication (MR HBC) provides ideas to improve the transmission effect. Although the coil's resonance properties have been proposed for MR HBC, the modeling and impedance matching for this method are still in the exploratory stage. However, different human impedances affect the coil resonance frequency to varying extents, leading to individual variability in the degree of magnetic coupling. This paper analyzes the influence of human tissues on the coil through finite element method (FEM) simulation modeling. This effect can be eliminated by employing a dual tunable capacitor matching method based on the field-circuit combination. By dynamically adjusting the values of the dual tunable capacitors in real-time, the human body and the coil can be tuned to a resonant state, effectively improving the degree of magnetic coupling. The results reveal that the proposed method enhances the communication gain by 38.91–42.02 dB at the preset frequency for different human tissues. In vivo experiments verify that the method eliminates the effect of different human impedances on the coil, which is of great significance for further improving the performance of MR HBC.
- 27 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 8 (2) , 94-101
Field-Circuit Combination Method for Solving the Detuning Problem of Magnetic Resonance Human Body Communication
The technological challenge to realize wearable medical devices is to ensure low power consumption and reliable transmission of communication. Magnetic resonance human body communication (MR HBC) provides ideas to improve the transmission effect. Although the coil's resonance properties have been proposed for MR HBC, the modeling and impedance matching for this method are still in the exploratory stage. However, different human impedances affect the coil resonance frequency to varying extents, leading to individual variability in the degree of magnetic coupling. This paper analyzes the influence of human tissues on the coil through finite element method (FEM) simulation modeling. This effect can be eliminated by employing a dual tunable capacitor matching method based on the field-circuit combination. By dynamically adjusting the values of the dual tunable capacitors in real-time, the human body and the coil can be tuned to a resonant state, effectively improving the degree of magnetic coupling. The results reveal that the proposed method enhances the communication gain by 38.91–42.02 dB at the preset frequency for different human tissues. In vivo experiments verify that the method eliminates the effect of different human impedances on the coil, which is of great significance for further improving the performance of MR HBC.
- 1 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 18 (4) , 872-884
A Time-Varying Equivalent Circuit Modeling and Measuring Approach for Intracardiac Communication in Leadless Pacemakers
Intracardiac wireless communication is crucial for the development of multi-chamber leadless cardiac pacemakers (LCP). However, the time-varying characteristics of intracardiac channel pose major challenges. As such, mastering the dynamic conduction properties of the intracardiac channel and modeling the equivalent time-varying channel are imperative for realizing LCP multi-chamber pacing. In this paper, we present a limiting volume variational approach based on the electrical properties of cardiac tissues and trends in chamber volume variation. This approach was used to establish a quasi-static and a continuous time-varying equivalent circuit model of an intracardiac channel. An equivalence analysis was conducted on the model, and a discrete time-varying equivalent circuit phantom grounded on the cardiac cycle was subsequently established. Moreover, an ex vivo cardiac experimental platform was developed for verification. Results indicate that in the frequency domain, the congruence between phantom and ex vivo experimental outcomes is as high as 94.3%, affirming the reliability of the equivalent circuit model. In the time domain, the correlation is up to 75.3%, corroborating its effectiveness. The proposed time-varying equivalent circuit model exhibits stable and standardized dynamic attributes, serving as a powerful tool for addressing time-varying challenges and simplifying in vivo or ex vivo experiments.
- 1 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 18 (4) , 872-884
A Time-Varying Equivalent Circuit Modeling and Measuring Approach for Intracardiac Communication in Leadless Pacemakers
Intracardiac wireless communication is crucial for the development of multi-chamber leadless cardiac pacemakers (LCP). However, the time-varying characteristics of intracardiac channel pose major challenges. As such, mastering the dynamic conduction properties of the intracardiac channel and modeling the equivalent time-varying channel are imperative for realizing LCP multi-chamber pacing. In this paper, we present a limiting volume variational approach based on the electrical properties of cardiac tissues and trends in chamber volume variation. This approach was used to establish a quasi-static and a continuous time-varying equivalent circuit model of an intracardiac channel. An equivalence analysis was conducted on the model, and a discrete time-varying equivalent circuit phantom grounded on the cardiac cycle was subsequently established. Moreover, an ex vivo cardiac experimental platform was developed for verification. Results indicate that in the frequency domain, the congruence between phantom and ex vivo experimental outcomes is as high as 94.3%, affirming the reliability of the equivalent circuit model. In the time domain, the correlation is up to 75.3%, corroborating its effectiveness. The proposed time-varying equivalent circuit model exhibits stable and standardized dynamic attributes, serving as a powerful tool for addressing time-varying challenges and simplifying in vivo or ex vivo experiments.
- 22 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 70 (8) , 3827-3837
A Visible Human Data-Based Whole-Body Model for Investigating the Transmission Attenuation of Intrabody Communication
Intrabody communication (IBC) is a promising approach for realizing information transmission among various wearable or implantable devices within bodyNET. The existing IBC studies are limited to the local or abstract geometric channel model, which is limited to providing efficient channel characteristics for the various transmitting scenarios. The aim of this article is to reconstruct a whole-body model with anatomical features and combine the field-circuit model for investigating the human channel characteristics. A visible human data (VHD) is established by segmentation and 3-D reconstruction of layered tissues. The transmission attenuation was simulated and analyzed through the finite element method. In vivo experiments and phantom experiments were implemented to validate the simulation results. For the on-body communication, the transmission attenuation of the short distance was similar to the low-pass filter’s amplitude-frequency characteristics. For the implantable communication, the consistency coefficient of the attenuation between in-body to on-body and on-body to in-body was higher than 98%, indicating that the body channel is bidirectional. This work provides a repeatable and verified VHD-based whole-body model for the human channel attenuation investigation. It is an essential step for the further development of IBC, such as the transceiver design and the multinodes’ protocol for bodyNET.
- 22 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 70 (8) , 3827-3837
A Visible Human Data-Based Whole-Body Model for Investigating the Transmission Attenuation of Intrabody Communication
Intrabody communication (IBC) is a promising approach for realizing information transmission among various wearable or implantable devices within bodyNET. The existing IBC studies are limited to the local or abstract geometric channel model, which is limited to providing efficient channel characteristics for the various transmitting scenarios. The aim of this article is to reconstruct a whole-body model with anatomical features and combine the field-circuit model for investigating the human channel characteristics. A visible human data (VHD) is established by segmentation and 3-D reconstruction of layered tissues. The transmission attenuation was simulated and analyzed through the finite element method. In vivo experiments and phantom experiments were implemented to validate the simulation results. For the on-body communication, the transmission attenuation of the short distance was similar to the low-pass filter’s amplitude-frequency characteristics. For the implantable communication, the consistency coefficient of the attenuation between in-body to on-body and on-body to in-body was higher than 98%, indicating that the body channel is bidirectional. This work provides a repeatable and verified VHD-based whole-body model for the human channel attenuation investigation. It is an essential step for the further development of IBC, such as the transceiver design and the multinodes’ protocol for bodyNET.