Iryna Romanenko
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Iryna Romanenko has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Elena Tomšík
Institute of Macromolecular Chemistry CAS, Heyrovského nám. 2, 162 00 Prague, Czech Republic
1 shared publication - Ivana Šeděnková
Department of Structural Analysis, Institute of Macromolecular Chemistry CAS, Heyrovského Náměstí 1888/2, 162 00 Praha 6, Czech Republic
1 shared publication - Martin Hrubý
Institute of Macromolecular Chemistry CAS, Heyrovského náměstí 2, 162 00 Prague 6, Czech Republic
1 shared publication - Ognen Pop-Georgievski
Institute of Macromolecular Chemistry Czech Academy of Sciences Prague Czech Republic
1 shared publication - Rimeh Ismail
Institute of Macromolecular Chemistry AS CR, Heyrovského nám. 2, 162 06 Prague, Czech Republic
1 shared publication - Zulfiya Černochová
Institute of Macromolecular Chemistry CAS Heyrovského nám. 2 Prague 16206 Czech Republic
1 shared publication
Latest Publications
- Open Access
- 23 June 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (7) , 446
Potentiometric Performance of Ion-Selective Electrodes Based on Polyaniline and Chelating Agents: Detection of Fe2+ or Fe3+ Ions
We constructed a sensor for the determination of Fe2+ and/or Fe3+ ions that consists of a polyaniline layer as an ion-to-electron transducer; on top of it, chelating molecules are deposited (which can selectively chelate specific ions) and protected with a non-biofouling poly(2-methyl-2-oxazoline)s layer. We have shown that our potentiometric sensing layers show a rapid response to the presence of Fe2+ or Fe3+ ions, do not experience interference with other ions (such as Cu2+), and work in a biological environment in the presence of bovine serum albumin (as a model serum protein). The sensing layers detect iron ions in the concentration range from 5 nM to 50 µM.
- 23 June 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (7) , 446
Open AccessPotentiometric Performance of Ion-Selective Electrodes Based on Polyaniline and Chelating Agents: Detection of Fe2+ or Fe3+ Ions
We constructed a sensor for the determination of Fe2+ and/or Fe3+ ions that consists of a polyaniline layer as an ion-to-electron transducer; on top of it, chelating molecules are deposited (which can selectively chelate specific ions) and protected with a non-biofouling poly(2-methyl-2-oxazoline)s layer. We have shown that our potentiometric sensing layers show a rapid response to the presence of Fe2+ or Fe3+ ions, do not experience interference with other ions (such as Cu2+), and work in a biological environment in the presence of bovine serum albumin (as a model serum protein). The sensing layers detect iron ions in the concentration range from 5 nM to 50 µM.