Ênio Costa Resende
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ênio Costa Resende has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Luiz Carlos Gomes Freitas
Faculty of Electrical Engineering, Federal University of Uberlandia, Uberlandia, Brazil
5 shared publications - Gustavo Brito de Lima
Universidade Federal de Uberlândia
2 shared publications - Arthur Gomes de Souza
Laboratory of Alternative Energies and Power System Protection Faculty of Electrical Engineering Federal University of Uberlândia Uberlândia Minas Gerais Brazil
1 shared publication - Beatriz Cristina Moura
Universidade Estadual de Campinas
1 shared publication - Danillo Borges Rodrigues
Universidade Federal do Triângulo Mineiro
1 shared publication - Gabriel M. Bernardes
Universidade Federal de Uberlândia
1 shared publication
Latest Publications
- Open Access
- 22 January 2026
- Published by Associacao Brasileira de Eletronica de Potencia SOBRAEP in Eletrônica de Potência
- Vol. 31, e202608
Automatic Power Flow Control Strategy in Hybrid Microgrids: Development and Validation using Controller Hardware-in-the-Loop
Research on hybrid microgrids has attracted significant interest mainly due to the advantages that this topology offers compared to a solely direct current (DC) or alternating current (AC) microgrid. Among these advantages, one of the most frequently mentioned is the increased system reliability, due to the possibility of operating in either islanded mode or grid-connected mode, depending on the need. Additionally, the ability to export power to the AC grid is a valuable application of this type of system. In this context, this paper proposes a new control and management strategy for a hybrid microgrid. The analyzed microgrid consists of a photovoltaic system, energy storage systems, and an emergency power source, as well as DC and AC loads. The interface with the AC side is achieved through an inverter, and the microgrid may or may not be connected to the external grid. The proposed strategy emphasizes the management of all subsystems, as well as the control of operations in both grid-connected and islanded modes. The system was implemented using Controller Hardware-in-the-Loop (C-HIL). The results demonstrated that the proposed strategy enabled effective microgrid management, particularly regarding the proper coordination of the batteries through SOC equalization and the maintenance of each operational state of the microgrid.
- 22 January 2026
- Published by Associacao Brasileira de Eletronica de Potencia SOBRAEP in Eletrônica de Potência
- Vol. 31, e202608
Open AccessAutomatic Power Flow Control Strategy in Hybrid Microgrids: Development and Validation using Controller Hardware-in-the-Loop
Research on hybrid microgrids has attracted significant interest mainly due to the advantages that this topology offers compared to a solely direct current (DC) or alternating current (AC) microgrid. Among these advantages, one of the most frequently mentioned is the increased system reliability, due to the possibility of operating in either islanded mode or grid-connected mode, depending on the need. Additionally, the ability to export power to the AC grid is a valuable application of this type of system. In this context, this paper proposes a new control and management strategy for a hybrid microgrid. The analyzed microgrid consists of a photovoltaic system, energy storage systems, and an emergency power source, as well as DC and AC loads. The interface with the AC side is achieved through an inverter, and the microgrid may or may not be connected to the external grid. The proposed strategy emphasizes the management of all subsystems, as well as the control of operations in both grid-connected and islanded modes. The system was implemented using Controller Hardware-in-the-Loop (C-HIL). The results demonstrated that the proposed strategy enabled effective microgrid management, particularly regarding the proper coordination of the batteries through SOC equalization and the maintenance of each operational state of the microgrid.
- Open Access
- 7 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (2) , 2377-2391
Attribution of Responsibility for Short-Duration Voltage Variations in Power Distribution Systems via QGIS, OpenDSS, and Python Language
Short-Duration Voltage Variations (SDVVs) are phenomena that significantly impact power quality. Although they typically last no longer than three minutes, such events can disrupt load operations and cause substantial production losses. This study presents an enhanced methodology for determining whether an SDVV event originates upstream or downstream of the point of common coupling between two agents interconnected through a transformer. Building upon the work of Ferreira et al., whose original approach was applied to a circuit using MATLAB/Simulink, this research advances the methodology by applying it to both real and benchmark distribution systems using open-source tools, namely QGIS, OpenDSS, and Python™. The well-known IEEE 34-Bus Test System has been used to verify the methodology’s generalizability. The method was also further validated through tests conducted on two actual Brazilian distribution feeders in Uberlândia, Minas Gerais: one supplying large industrial consumers such as a rice mill and a carbonated beverages factory, and the other serving a municipal wastewater treatment plant and a large photovoltaic plant. By using real, detailed and georeferenced data, the approach ensures an accurate representation of both the network topology and the installed equipment. The results confirm that the proposed methodology reliably identifies the origin of SDVV events. A key contribution of this study is that the attribution of responsibility remains robust regardless of variations in transformer winding configurations, fault resistance, circuit topology, load characteristics, or the presence of distributed generation. These findings demonstrate the accessibility, robustness and practical applicability, offering a valuable tool for utilities and researchers aiming to enhance power quality and accountability in distribution networks.
- 7 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (2) , 2377-2391
Open AccessAttribution of Responsibility for Short-Duration Voltage Variations in Power Distribution Systems via QGIS, OpenDSS, and Python Language
Short-Duration Voltage Variations (SDVVs) are phenomena that significantly impact power quality. Although they typically last no longer than three minutes, such events can disrupt load operations and cause substantial production losses. This study presents an enhanced methodology for determining whether an SDVV event originates upstream or downstream of the point of common coupling between two agents interconnected through a transformer. Building upon the work of Ferreira et al., whose original approach was applied to a circuit using MATLAB/Simulink, this research advances the methodology by applying it to both real and benchmark distribution systems using open-source tools, namely QGIS, OpenDSS, and Python™. The well-known IEEE 34-Bus Test System has been used to verify the methodology’s generalizability. The method was also further validated through tests conducted on two actual Brazilian distribution feeders in Uberlândia, Minas Gerais: one supplying large industrial consumers such as a rice mill and a carbonated beverages factory, and the other serving a municipal wastewater treatment plant and a large photovoltaic plant. By using real, detailed and georeferenced data, the approach ensures an accurate representation of both the network topology and the installed equipment. The results confirm that the proposed methodology reliably identifies the origin of SDVV events. A key contribution of this study is that the attribution of responsibility remains robust regardless of variations in transformer winding configurations, fault resistance, circuit topology, load characteristics, or the presence of distributed generation. These findings demonstrate the accessibility, robustness and practical applicability, offering a valuable tool for utilities and researchers aiming to enhance power quality and accountability in distribution networks.
- Open Access
- 21 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 43495-43505
New Global Maximum Power Point Tracking Technique Based on Indirect PV Array Voltage Control for Photovoltaic String Inverters With Reduced Number of Sensors
This paper presents a study regarding the development of a single-stage single-phase grid-tied photovoltaic (PV) inverter with a new Global Maximum Power Point Tracking (GMPPT) technique. The proposed strategy is based on the indirect PV array voltage control and allows for the development of PV inverter with reduced number of sensors, therefore, increasing the system reliability and reducing costs. The proposed strategy was denominated Sensorless PV Array Voltage Control for Global Maximum Power Point Tracking (SPVAVC-GMPPT). The static and dynamic accuracy of the GMPPT algorithm has been demonstrated to be over 99% under different operating conditions of irradiance and temperature and also under shading conditions, where multiple false Maximum Power Points (MPPs) occur. Simulation and experimental results are shown, compared, and discussed, with a 99,45% TF for standard-test conditions (STC – 25 °C and 1000 W/m²) and even higher (99,96%) under different irradiance and temperature proving the effectiveness of the proposed technique.
- 21 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 43495-43505
Open AccessNew Global Maximum Power Point Tracking Technique Based on Indirect PV Array Voltage Control for Photovoltaic String Inverters With Reduced Number of Sensors
This paper presents a study regarding the development of a single-stage single-phase grid-tied photovoltaic (PV) inverter with a new Global Maximum Power Point Tracking (GMPPT) technique. The proposed strategy is based on the indirect PV array voltage control and allows for the development of PV inverter with reduced number of sensors, therefore, increasing the system reliability and reducing costs. The proposed strategy was denominated Sensorless PV Array Voltage Control for Global Maximum Power Point Tracking (SPVAVC-GMPPT). The static and dynamic accuracy of the GMPPT algorithm has been demonstrated to be over 99% under different operating conditions of irradiance and temperature and also under shading conditions, where multiple false Maximum Power Points (MPPs) occur. Simulation and experimental results are shown, compared, and discussed, with a 99,45% TF for standard-test conditions (STC – 25 °C and 1000 W/m²) and even higher (99,96%) under different irradiance and temperature proving the effectiveness of the proposed technique.
- Open Access
- 23 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 17195-17230
Anti-Islanding Techniques for Integration of Inverter-Based Distributed Energy Resources to the Electric Power System
The emergence of microgrids and the increasing adoption of Distributed Generation Systems (DGS) have created an opportunity to replace traditional fossil fuels with renewable resources. Such a shift poses security and power quality challenges that must be addressed by academics and industrial research paradigms. Unintentional islanding is an important security concern, as it can result in power quality degradation, electrical hazards, and equipment damage. To address this problem and find efficient solutions, many anti-islanding techniques to detect and eliminate the phenomenon can be found in the specialized literature. These solutions can be classified as passive, active, remote, hybrid, or based on machine learning and signal processing techniques. In this context, this paper provides a comprehensive review of existing anti-islanding methods, highlighting their importance in preventing dangerous situations. The review includes a detailed analysis of advantages and limitations found for each method, as well as its suitability for practical applications. The goal is to provide a valuable resource for researchers and practitioners in the field of distributed power systems, enabling them to choose the most appropriate anti-islanding method for their specific needs. Overall, this paper aims to address the challenges posed by unintentional islanding and promote the adoption of renewable energy resources for a more sustainable future.
- 23 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 17195-17230
Open AccessAnti-Islanding Techniques for Integration of Inverter-Based Distributed Energy Resources to the Electric Power System
The emergence of microgrids and the increasing adoption of Distributed Generation Systems (DGS) have created an opportunity to replace traditional fossil fuels with renewable resources. Such a shift poses security and power quality challenges that must be addressed by academics and industrial research paradigms. Unintentional islanding is an important security concern, as it can result in power quality degradation, electrical hazards, and equipment damage. To address this problem and find efficient solutions, many anti-islanding techniques to detect and eliminate the phenomenon can be found in the specialized literature. These solutions can be classified as passive, active, remote, hybrid, or based on machine learning and signal processing techniques. In this context, this paper provides a comprehensive review of existing anti-islanding methods, highlighting their importance in preventing dangerous situations. The review includes a detailed analysis of advantages and limitations found for each method, as well as its suitability for practical applications. The goal is to provide a valuable resource for researchers and practitioners in the field of distributed power systems, enabling them to choose the most appropriate anti-islanding method for their specific needs. Overall, this paper aims to address the challenges posed by unintentional islanding and promote the adoption of renewable energy resources for a more sustainable future.
- Open Access
Implementation and Critical Analysis of the Active Phase Jump with Positive Feedback Anti-Islanding Algorithm
The protection against the unintentional islanding of Grid-Tied inverters is an important electrical security issue addressed by the main Standards. This concern is justified in face of the fact that unintentional islanding can lead to abrupt variations of voltage and frequency, electrical damages, professional accidents, power quality degradation, and out-of-phase reclosure. In response to the islanding concern, the literature has proposed several Anti-Islanding Protection (AIP) schemes that can be divided in passive and active methods. Many of the active AIP is based on the insertion of some disturbance in the inverter current in order to deviate the frequency out of the allowed thresholds, tripping the inverter internal disconnection system. Thus, the main objective of this paper is to analyze the performance of the Active Phase Jump with Positive Feedback (APJPF) algorithm compared to other well-known frequency drift-based solutions. More than that, this work covers the Non-Detection Zone (NDZ) problem, analyzing its main mapping methodologies and the normative requirements, exposing the minimum normative recommendations a given AIP must reach to be considered functional. The last contributions of this paper are the proposal of a parametrization criterion for the Active Frequency Drift with Pulsating Chopping Factor (AFDPCF) and for the APJPF.
Open AccessImplementation and Critical Analysis of the Active Phase Jump with Positive Feedback Anti-Islanding Algorithm
The protection against the unintentional islanding of Grid-Tied inverters is an important electrical security issue addressed by the main Standards. This concern is justified in face of the fact that unintentional islanding can lead to abrupt variations of voltage and frequency, electrical damages, professional accidents, power quality degradation, and out-of-phase reclosure. In response to the islanding concern, the literature has proposed several Anti-Islanding Protection (AIP) schemes that can be divided in passive and active methods. Many of the active AIP is based on the insertion of some disturbance in the inverter current in order to deviate the frequency out of the allowed thresholds, tripping the inverter internal disconnection system. Thus, the main objective of this paper is to analyze the performance of the Active Phase Jump with Positive Feedback (APJPF) algorithm compared to other well-known frequency drift-based solutions. More than that, this work covers the Non-Detection Zone (NDZ) problem, analyzing its main mapping methodologies and the normative requirements, exposing the minimum normative recommendations a given AIP must reach to be considered functional. The last contributions of this paper are the proposal of a parametrization criterion for the Active Frequency Drift with Pulsating Chopping Factor (AFDPCF) and for the APJPF.