Ruiying Liao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ruiying Liao has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Jigui Zhu
State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin, China
3 shared publications - Linghui Yang
Tianjin Univ, State Key Lab Precis Measurement Technol & Instrum, Tianjin 300072, Peoples R China
3 shared publications - Haihan Yu
Multidisciplinary Research Center, Institute of High Energy Physics of the Chinese Academy of Sciences, Beijing, People's Republic of China
2 shared publications - Luyao Ma
Tianjin Univ, State Key Lab Precis Measuring Technol & Instrumen, Tianjin 300072, Peoples R China
2 shared publications - Ming Li
Multidisciplinary Research Center, Institute of High Energy Physics of the Chinese Academy of Sciences, Beijing, People's Republic of China
2 shared publications - Shanzhi Tang
Institute of High Energy Physics, Chinese Academy of Sciences
2 shared publications
Latest Publications
- Open Access
- 5 August 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (5) , 1346-1355
Structure design and implementation of a water cooling sub-20 nm multilayer Kirkpatrick–Baez mirror system in the Structural Dynamics beamline ID23 at HEPS
The first water-cooling nano multilayer Kirkpatrick–Baez mirror system in the Structural Dynamics beamline (ID23) at High Energy Photon Source (HEPS) has been implemented. An Invar gantry is engineered to achieve a balance between light weight and stability. The cooling system, including eutectic gallium–indium (eGaIn), copper braids and a cooling water circuit with a multi-bend copper pipe in a compact space, decouples movement and mitigates vibration. The mirror cooling holders introduce less than 0.5 nm RMS height error and 0.1 µrad RMS slope error in the mirror surface shapes. A series of stability tests is applied to verify the mechanism structure. In a 1 h test assessment using a water-cooling flow of 4.5 L min −1 , the system demonstrated a positional stability of 5.96 nm and an angular stability of 86.76 nrad from 1 Hz to 500 Hz. The focal spot size of 13.39 nm × 15.15 nm (H × V) at a photon energy of 21.8 keV demonstrates the system's performance.
- 5 August 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (5) , 1346-1355
Open AccessStructure design and implementation of a water cooling sub-20 nm multilayer Kirkpatrick–Baez mirror system in the Structural Dynamics beamline ID23 at HEPS
The first water-cooling nano multilayer Kirkpatrick–Baez mirror system in the Structural Dynamics beamline (ID23) at High Energy Photon Source (HEPS) has been implemented. An Invar gantry is engineered to achieve a balance between light weight and stability. The cooling system, including eutectic gallium–indium (eGaIn), copper braids and a cooling water circuit with a multi-bend copper pipe in a compact space, decouples movement and mitigates vibration. The mirror cooling holders introduce less than 0.5 nm RMS height error and 0.1 µrad RMS slope error in the mirror surface shapes. A series of stability tests is applied to verify the mechanism structure. In a 1 h test assessment using a water-cooling flow of 4.5 L min −1 , the system demonstrated a positional stability of 5.96 nm and an angular stability of 86.76 nrad from 1 Hz to 500 Hz. The focal spot size of 13.39 nm × 15.15 nm (H × V) at a photon energy of 21.8 keV demonstrates the system's performance.
- Open Access
- 16 July 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (5) , 1289-1302
A beam-direction cross-vessel metrology method and error analysis for the ptychography setup at HEPS ID09
A metrology method dedicated to position monitoring and correction for the ptychography setup at the High Energy Photon Source (HEPS, Beijing, China) beamline ID09 is proposed. The sophisticated design of the Invar interferometer metrology frame ensures optimal performance within the compact environment between the focal spot and the sample setup. The measurement method and error analysis are described in detail. The sample setup achieves a positional stability of less than 2 nm RMS from 1 Hz to 500 Hz. The 12.3 nm reconstruction resolution of 2D ptychography at 12.4 keV demonstrates that the interferometer metrology strategy is available.
- 16 July 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (5) , 1289-1302
Open AccessA beam-direction cross-vessel metrology method and error analysis for the ptychography setup at HEPS ID09
A metrology method dedicated to position monitoring and correction for the ptychography setup at the High Energy Photon Source (HEPS, Beijing, China) beamline ID09 is proposed. The sophisticated design of the Invar interferometer metrology frame ensures optimal performance within the compact environment between the focal spot and the sample setup. The measurement method and error analysis are described in detail. The sample setup achieves a positional stability of less than 2 nm RMS from 1 Hz to 500 Hz. The 12.3 nm reconstruction resolution of 2D ptychography at 12.4 keV demonstrates that the interferometer metrology strategy is available.
- Open Access
- 9 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-16
Flexible High-Resolution Continuous 3-D Scanning for Large-Scale Industrial Components
Generating a large-scale high-density point cloud is crucial for 3-D shape measurements. Both area-scan and line-scan camera systems have advantages and limitations for large-scale structured light measurement. Consequently, we propose a method that achieves complementary advantages of both the camera systems through flexible continuous scanning with high resolution and frequency. For point cloud generation, efficient scanning in continuous motion with high resolution, large field of view, and high frequency is realized using line-scan cameras. A flexible registration strategy without mechanical positioning is proposed for point cloud registration after referring to the registration methods in area-scan camera systems. To realize the above functions, system structure and calibration are designed. Techniques for point cloud generation with high dynamic performance and interference resistance are introduced. The point cloud registration strategy includes methods for high-frequency pose acquisition and processing. Moreover, an optimization method is designed for the point cloud after registration, and the texture is attached. The proposed system has excellent prospects for large-scale industrial component measurements.
- 9 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-16
Open AccessFlexible High-Resolution Continuous 3-D Scanning for Large-Scale Industrial Components
Generating a large-scale high-density point cloud is crucial for 3-D shape measurements. Both area-scan and line-scan camera systems have advantages and limitations for large-scale structured light measurement. Consequently, we propose a method that achieves complementary advantages of both the camera systems through flexible continuous scanning with high resolution and frequency. For point cloud generation, efficient scanning in continuous motion with high resolution, large field of view, and high frequency is realized using line-scan cameras. A flexible registration strategy without mechanical positioning is proposed for point cloud registration after referring to the registration methods in area-scan camera systems. To realize the above functions, system structure and calibration are designed. Techniques for point cloud generation with high dynamic performance and interference resistance are introduced. The point cloud registration strategy includes methods for high-frequency pose acquisition and processing. Moreover, an optimization method is designed for the point cloud after registration, and the texture is attached. The proposed system has excellent prospects for large-scale industrial component measurements.
- Open Access
- 6 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-12
A Dense 3-D Point Cloud Measurement Based on 1-D Background-Normalized Fourier Transform
The 3D surface measurement plays a significant role in the industrial area. With the advantages of high resolution and acquisition rate, dual line-scan cameras system have been gradually studied for dynamic 3D measurement. However, the partial overexposure and the limited measurement depth range of dual line-scan cameras are the two main elements affecting the quality of the point cloud. Both of these problems are caused by incorrect pixel matching. Therefore, this paper present a matching strategy for dual line-scan cameras based on the one-dimensional background-normalized Fourier transform (1DBNFT) to expands the depth range of measurement and deal with the partial overexposure. The wrapped phases extracted by 1DBNFT, the unwrapped phase extracted by projection distance minimization (PDM), and the matching principle are described in detail. We also analyze the possible errors in the system from three aspects, that are noncoplanar error, installation error, and motion error. Finally, the comparative experiments and accuracy verification experiments demonstrate the effectiveness of our algorithm.
- 6 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-12
Open AccessA Dense 3-D Point Cloud Measurement Based on 1-D Background-Normalized Fourier Transform
The 3D surface measurement plays a significant role in the industrial area. With the advantages of high resolution and acquisition rate, dual line-scan cameras system have been gradually studied for dynamic 3D measurement. However, the partial overexposure and the limited measurement depth range of dual line-scan cameras are the two main elements affecting the quality of the point cloud. Both of these problems are caused by incorrect pixel matching. Therefore, this paper present a matching strategy for dual line-scan cameras based on the one-dimensional background-normalized Fourier transform (1DBNFT) to expands the depth range of measurement and deal with the partial overexposure. The wrapped phases extracted by 1DBNFT, the unwrapped phase extracted by projection distance minimization (PDM), and the matching principle are described in detail. We also analyze the possible errors in the system from three aspects, that are noncoplanar error, installation error, and motion error. Finally, the comparative experiments and accuracy verification experiments demonstrate the effectiveness of our algorithm.
- 12 January 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10621, 106210A-3
A stereo line-scan system for 3D shape measurement of fast-moving objects
With outstanding features of high resolution and high acquisition rate, line-scan imaging holds great potentials for high-speed applications. This paper presents a stereo line-scan system for 3D shape measurement of fast moving objects. The principle and key technologies are addressed. The system setup and 3D imaging model are introduced first and the stereo matching scheme and calibration approach are described subsequently. The system is verified by experiments. The results demonstrate the validity and accuracy of the proposed system.
- 12 January 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10621, 106210A-3
A stereo line-scan system for 3D shape measurement of fast-moving objects
With outstanding features of high resolution and high acquisition rate, line-scan imaging holds great potentials for high-speed applications. This paper presents a stereo line-scan system for 3D shape measurement of fast moving objects. The principle and key technologies are addressed. The system setup and 3D imaging model are introduced first and the stereo matching scheme and calibration approach are described subsequently. The system is verified by experiments. The results demonstrate the validity and accuracy of the proposed system.