LZLie Zhao

Lie Zhao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lie Zhao has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Accurate Extraction of Body-Diode-Conduction for Synchronous Rectification of CLLC Resonant Converters in High-Voltage Application

    by Long Pei, Lixin Jia, Laili Wang, Lie Zhao, Wei Cao, Lei Zhu, Yunqing Pei

    Mainstream adaptive drain–source voltage-sensing-based synchronous rectification (ADVS-SR) has rarely been used for CLLC converters in higher output-voltage applications (HOVA) due to the issue of sensing accuracy and high dv/dt. This letter proposes a novel body-diode-conduction (BDC) extraction circuit consisting of an accurate drain–source voltage sensing circuit and a customized valley-conduction-detection (VCD) circuit for ADVS-SR in HOVA. The compensation diodes packaged together with blocking diodes can eliminate the sensing error accurately with a single PNP transistor instead of complex current mirror. Absorption diodes and series combination of blocking diode effectively solve the high-dv/dt issue. The traditional external negative threshold voltage for the voltage comparison in VCD circuit can be omitted. Thus, the proposed BDC extraction circuit is accurate, high-dv/dt immune and easy-to-implement, and the performance of which have been validated from the experimental results in a 1 kW-500 V CLLC prototype.


  • Analysis and Design of LCL Resonant Tank With Reduced Reactive Power for Bidirectional On-Board Charger Applications Utilizing Time-Domain Model

    by Lie Zhao, Yunqing Pei, Laili Wang, Long Pei, Zhixiang Li, Wei Cao

    To address the wide voltage conversion requirements in the field of battery charging, the LCL resonant tank adopting pulse frequency modulation (PFM) is investigated utilizing time domain model (TDM) in this paper. LCL exhibits similar soft switching characteristics and enhanced voltage gain regulation capability with simpler resonant tank than existing classic CLLC. The operating principles, mode distribution and power transfer properties of LCL during bidirectional operations are presented and analyzed in detail utilizing TDM. By incorporating TDM, the low accuracy deficiency of first harmonic approximation (FHA) for wide voltage applications is completely eliminated, and the implementation of full-range ZVS with time-domain accuracy becomes feasible. An LCL resonant parameters optimization method that is capable of providing the required voltage gain and guaranteeing the achievement of ZVS with reduced reactive power under desired load conditions during bidirectional operations is proposed. Finally, the revealed experimental results from a 1-kW prototype validated the correctness of the TDM theoretical analysis and the effectiveness of the proposed optimization method. The optimized prototype achieves the designed 1.8X voltage gain within a narrow switching frequency range of 88.7kHz to 120kHz and a peak efficiency of 97.306%.


  • A Comprehensive Closed-Loop Voltage Ripple Control Scheme for Modular Multilevel Converter-Based Power Electronic Transformers

    by Zhixiang Li, Yunqing Pei, Laili Wang, Lie Zhao, Long Pei, Wei Cao

    The power electronic transformer (PET) based on a cascade connection of modular multilevel converter (MMC) submodules with dual active bridges (DAB) is a promising topology for future hybrid ac/dc distribution grids. The voltage ripple suppression is of great importance for the power density improvement of this topology. However, traditional voltage ripple control strategies suffer from steady-state errors, couplings among different control loops, and considerable extra power loss. This article presents a comprehensive closed-loop voltage ripple control scheme for the MMC-based PET based on ripple power transfer (RPT). First, a decoupled closed-loop voltage ripple control structure in dual rotating reference frames is derived, offering advantages including high steady-state accuracy and no coupling among different control loops. In addition, to minimize the extra power loss of DABs caused by RPT, an optimal operation strategy based on partial RPT and the corresponding control diagram that is convenient for real-time implementation are presented. Experimental results obtained from a scaled-down PET prototype demonstrate that the proposed voltage ripple control scheme can effectively reduce the steady-state error of the voltage ripple control, eliminate the couplings among different control loops, and improve the overall efficiency.


  • An Enhanced Adaptive Synchronous Rectification With Turn-ON Optimization for LLC Converters Based on Stepwise-Plus-Feedforward Control

    by Long Pei, Lixin Jia, Laili Wang, Lie Zhao, Zhixiang Li, Wei Cao, Yunqing Pei

    Synchronous rectification (SR) is an essential aspect for LLC resonant converters to achieve high-efficiency design, and mainstream SR methods is the adaptive directly-voltage-sensing-based method (ADVS-SR), where the drain-source voltage of SR switch is sensed. However, due to the present of parasitic capacitor of transformer and output capacitors of SR switches, undeserved bode-diode conduction (BDC) caused by intricate voltage ringing across SR switch will invalidate the conventional ADVS-SR turn- on time tuning process under light-load condition, resulting in the dissipation of power efficiency. To solve this problem, in this paper, the capacitive current spike, which is the main root of the voltage ringing in terms of turn- on , are modeled and analyzed, and then different SR turn- on candidates are compared. Based on that, this paper proposes an enhanced adaptive SR strategy based on a novel stepwise-plus-feedforward (SPF) control to optimize SR turn- on . The SPF-SR strategy can eliminate not only large reverse current caused by premature turn- on but also large BDC interval caused by belated turn- on over the whole operating range. On the basis of ADVS, the SPF-SR only need to sense extra Vin , Vo , and Io , which are easily sensed DC signals, and can be easily implemented in a cost-effective digital controller. Finally, a 300W LLC prototype is built where experimental results show that the SR turn- on issue is optimized by the SPF-SR strategy, and compared with commercial SR IC and conventional ADVS-SR, the SPF-SR strategy improves power efficiency up to 6.99% and 5.52%, respectively.


  • Analysis and Design of LCCL Resonant Converter Based on Time-Domain Model for Bidirectional Onboard Charger Applications

    by Lie Zhao, Yunqing Pei, Laili Wang, Long Pei, Wei Cao, Yongmei Gan

    A novel bidirectional LCCL resonant dc–dc converter is proposed in this article. By substituting the magnetizing inductance of CLLC with a parallel resonant capacitor, the LCCL resonant converter obtains enhanced voltage gain regulation capability compared to CLLC while maintaining zero-voltage switching (ZVS) for the inverting side and zero-current switching for the rectifier side during bidirectional power flow. The state of the isolated bidirectional dc–dc converters is thoroughly reviewed in this article. The operating principle and gain characteristic of LCCL under bidirectional power flow are explored in detail adopting time-domain model, which effectively overcomes the drawback of the lower accuracy of the first harmonic approximation in wide voltage range applications and guarantees the achievement of ZVS in time-domain accuracy. A parameters optimization method of LCCL is provided to address the wide voltage range of battery applications, which is capable of achieving the required bidirectional voltage gain and ZVS operation over the designed frequency range under the desired load conditions while minimizing reactive power. Finally, a laboratory prototype rated at 1 kW is developed to convert between 400 and 250–450 V bidirectional. The experimental results confirm the feasibility of the proposed LCCL topology and the validity of the corresponding parameters optimization method.


  • Design Methodology of Bidirectional Resonant CLLC Charger for Wide Voltage Range Based on Parameter Equivalent and Time Domain Model

    by Lie Zhao, Yunqing Pei, Laili Wang, Long Pei, Wei Cao, Yongmei Gan

    The bidirectional CLLC resonant converter has distinguished potential in battery chargers and energy storage systems for its advantages in soft switching and bidirectional power flow capability. However, traditional CLLC converters generally adopt symmetrical design to maintain bidirectional symmetrical characteristics, which means the secondary LC network is designed to be equal to the primary LC network after reflection. The symmetrical design is only suitable for voltage grade matching scenarios where a wide voltage range is not required, such as CLLC-type dc transformers. Whereas in the field of bidirectional chargers, due to the wide voltage range of battery, there are significant differences in the characteristics required between charging and discharging mode, which makes symmetrical design no longer applicable. To cope with this issue, this paper proposes a novel design methodology of CLLC based on parameter equivalent and time domain model. With the parameter equivalent principle, the CLLC resonant tank with arbitrary parameters is investigated to satisfy the requirements of wide voltage range for bidirectional charger application. Compared with the symmetrical design, the proposed method can meet the requirements of bidirectional gain within preset frequency range and guarantee the achievement of zero-voltage switching under required load conditions with the minimum reactive power. In addition, the area product capacity of the magnetic part of the CLLC resonant tank is minimized based on the parameter equivalent principle. Finally, experiments have been performed on a 1 kW prototype to confirm the validity and feasibility of the proposed design methodology.