Yani Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yani Wang has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Chun Liu
College of Electrical Engineering, Shanghai University of Electric Power, Shanghai, China
2 shared publications - Xingwu Yang
Engineering Research Center of Offshore Wind Technology Ministry of Education, Shanghai University of Electric Power, Shanghai, China
2 shared publications - Feng Liu
College of Electrical Engineering and Control Science, Nanjing Tech University, Nanjing, China
1 shared publication - Kiruba Sivasubramaniam Haran
Department of Electrical and Computer Engineering, University of Illinois Urbana-Champaign, Urbana, IL, USA
1 shared publication - Shuai Zhang
College of Electrical Engineering, Shanghai University of Electric Power, Shanghai 200090, China
1 shared publication - Tao Han
Shanghai Jiao Tong University
1 shared publication
Latest Publications
- 10 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 12 (6) , 5839-5851
Online Harmonic Injection for MMC Over a Wide Frequency Range in DC Offshore Wind Farms
Modular multilevel converter (MMC) based wind power converter exhibit large sub-module (SM) capacitor voltage fluctuation due to the low-frequency output characteristics of wind turbines. Harmonic injection (HI) can effectively suppress the SM capacitor voltage fluctuation, but its injection value should be adjusted according to the change in MMC operating conditions. This implies that it is challenging to determine the optimal injection value. To address these challenges, we propose an online harmonic injection (OHI) strategy for the MMC operating in a wide frequency range. The strategy comprises second-order harmonic current injection (SHCI) and third-order harmonic voltage injection (THVI), where the amplitude of the second-order harmonic current is calculated automatically to dynamically change with wind speed changes in offshore wind farms. The fluctuation characteristics of the SM capacitor voltage over a wide frequency range are evaluated. The mathematical model of the proposed OHI strategy is then established as a unified calculation principle. The proposed strategy can suppress SM capacitor voltage fluctuations and reduce the MMC power loss over a wide range of wind speeds. The SM capacitance can also be reduced by 27% using the proposed method. The effectiveness of the proposed OHI strategy is validated by Simulink simulations and hardware experiments.
- 10 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 12 (6) , 5839-5851
Online Harmonic Injection for MMC Over a Wide Frequency Range in DC Offshore Wind Farms
Modular multilevel converter (MMC) based wind power converter exhibit large sub-module (SM) capacitor voltage fluctuation due to the low-frequency output characteristics of wind turbines. Harmonic injection (HI) can effectively suppress the SM capacitor voltage fluctuation, but its injection value should be adjusted according to the change in MMC operating conditions. This implies that it is challenging to determine the optimal injection value. To address these challenges, we propose an online harmonic injection (OHI) strategy for the MMC operating in a wide frequency range. The strategy comprises second-order harmonic current injection (SHCI) and third-order harmonic voltage injection (THVI), where the amplitude of the second-order harmonic current is calculated automatically to dynamically change with wind speed changes in offshore wind farms. The fluctuation characteristics of the SM capacitor voltage over a wide frequency range are evaluated. The mathematical model of the proposed OHI strategy is then established as a unified calculation principle. The proposed strategy can suppress SM capacitor voltage fluctuations and reduce the MMC power loss over a wide range of wind speeds. The SM capacitance can also be reduced by 27% using the proposed method. The effectiveness of the proposed OHI strategy is validated by Simulink simulations and hardware experiments.
- Open Access
Effect of Nano-MgO Doping in XLPE on Charge Transport and Electric Field Distribution in Composite Insulation of HVDC Cable Joint
The space charge characteristics of cross-linked polyethylene (XLPE) can be improved to some extent by doping the appropriate amount of nano-MgO. In this study, in order to explore the influence of nano-MgO on the space charge and electric field distributions of the composite insulation of high voltage direct current (HVDC) cable joints, the effect of nano-MgO concentration on the depth and density of the deep traps in MgO/XLPE was first analyzed. On this basis, the charge transport simulation model of a 320 kV HVDC cable joint was established with MgO/XLPE as the cable insulation, and the space charge and electric field distributions of the cable joint under different temperature conditions were simulated. It was found that the radial charge distribution in the joint shows different trends with the change of nano-MgO concentration. There is a significant difference in the charge density on both sides of the (MgO/XLPE)/EPDM interface, and the difference first decreased and then increased with the increase of concentration. When the nano-MgO concentration was 0.5 wt%, the number of charges in the radial direction is the fewest, and the maximum value is only 0.42 C/m−3. The radial electric field changed abruptly at the (MgO/XLPE)/EPDM interface, and it was homogenized to a certain extent with time. It was found that the highest electric field of the interface is at the root of the stress cone, which is the weakest point of the joint insulation. When the nano-MgO concentration was 0.5 wt%, the electric field at the root of the stress cone was found to be the lowest, with a value of 13.38 kV/mm. A comprehensive comparison shows that the joint can maintain better insulation when the concentration is 0.5 wt% compared to other concentrations. The results can provide a basis for further improving the insulation properties of HVDC cable joints through nano doping technology.
Open AccessEffect of Nano-MgO Doping in XLPE on Charge Transport and Electric Field Distribution in Composite Insulation of HVDC Cable Joint
The space charge characteristics of cross-linked polyethylene (XLPE) can be improved to some extent by doping the appropriate amount of nano-MgO. In this study, in order to explore the influence of nano-MgO on the space charge and electric field distributions of the composite insulation of high voltage direct current (HVDC) cable joints, the effect of nano-MgO concentration on the depth and density of the deep traps in MgO/XLPE was first analyzed. On this basis, the charge transport simulation model of a 320 kV HVDC cable joint was established with MgO/XLPE as the cable insulation, and the space charge and electric field distributions of the cable joint under different temperature conditions were simulated. It was found that the radial charge distribution in the joint shows different trends with the change of nano-MgO concentration. There is a significant difference in the charge density on both sides of the (MgO/XLPE)/EPDM interface, and the difference first decreased and then increased with the increase of concentration. When the nano-MgO concentration was 0.5 wt%, the number of charges in the radial direction is the fewest, and the maximum value is only 0.42 C/m−3. The radial electric field changed abruptly at the (MgO/XLPE)/EPDM interface, and it was homogenized to a certain extent with time. It was found that the highest electric field of the interface is at the root of the stress cone, which is the weakest point of the joint insulation. When the nano-MgO concentration was 0.5 wt%, the electric field at the root of the stress cone was found to be the lowest, with a value of 13.38 kV/mm. A comprehensive comparison shows that the joint can maintain better insulation when the concentration is 0.5 wt% compared to other concentrations. The results can provide a basis for further improving the insulation properties of HVDC cable joints through nano doping technology.
- Open Access
Design and Management of High Voltage Power Systems and Insulation Materials
To satisfy the fast-growing electricity demand, high-voltage power systems with higher performance and better stability are required, which raises challenges including the design of power systems, the control of high-power electronics, the synthesis and preparation of high-performance insulation materials, evaluation of the insulation conditions, dielectric insulation tests, material modification, environment protection, etc
Open AccessDesign and Management of High Voltage Power Systems and Insulation Materials
To satisfy the fast-growing electricity demand, high-voltage power systems with higher performance and better stability are required, which raises challenges including the design of power systems, the control of high-power electronics, the synthesis and preparation of high-performance insulation materials, evaluation of the insulation conditions, dielectric insulation tests, material modification, environment protection, etc
- 30 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 7 (4) , 2951
Corrections to “Partial Discharge Investigation of Form-Wound Electric Machine Winding for Electric Aircraft Propulsion” [Mar 21 78-90]
In the above article [1] , the original title “Partial Discharge Investigation of Form-Wound Electric Machine Winding for Electric Aircraft Propulsion” is wrong and should be “Partial-Discharge-Free Insulation Design of Air-Core Permanent Magnet Synchronous Machine for Aircraft Propulsion.”
- 30 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 7 (4) , 2951
Corrections to “Partial Discharge Investigation of Form-Wound Electric Machine Winding for Electric Aircraft Propulsion” [Mar 21 78-90]
In the above article [1] , the original title “Partial Discharge Investigation of Form-Wound Electric Machine Winding for Electric Aircraft Propulsion” is wrong and should be “Partial-Discharge-Free Insulation Design of Air-Core Permanent Magnet Synchronous Machine for Aircraft Propulsion.”