Zuliang Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zuliang Huang has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Zhao Yang Dong
City University of Hong Kong
5 shared publications - Shuying Lai
City University of Macau
4 shared publications - Yan Li
School of Automation, Central South University, Changsha, China
4 shared publications - Yuechuan Tao
City University of Hong Kong
4 shared publications - Tong Li
City University of Hong Kong
3 shared publications Zuqing Zheng
Department of Electrical Engineering, City University of Hong Kong, Hong Kong, China
3 shared publications
Latest Publications
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Consumer Electronics
- Vol. 72 (4) , 10831-10843
Meteorology-Driven Self-Correcting LLM Priors for Smart Grid Outage Prediction and Bayesian Fault-Chain Risk Analysis
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Consumer Electronics
- Vol. 72 (4) , 10831-10843
Meteorology-Driven Self-Correcting LLM Priors for Smart Grid Outage Prediction and Bayesian Fault-Chain Risk Analysis
- 2 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Consumer Electronics
- Vol. 72 (2) , 4018-4028
Risk-Aware AIoT-Based Fault Detection for Power Line Monitoring in Consumer Energy Systems
Reliable power line monitoring is critical for consumer energy systems that increasingly depend on distributed sensors, smart terminals, and IoT-enabled edge devices. In practical deployments, fault detection performance is often affected by changing operating conditions, noisy measurements, and unreliable prediction confidence. This paper proposes a risk-aware AIoT-based fault detection framework that integrates multi-domain signal representation, uncertainty-aware inference, and confidence-adaptive decision making. High-frequency waveform signals are analyzed across time, frequency, and wavelet domains to capture complementary fault characteristics, and are adaptively fused to preserve localized and nonstationary patterns. Instead of producing deterministic outputs, a Dirichlet-based Prior Network is employed to jointly estimate fault probability and predictive uncertainty. These quantities are combined into a scalar risk score that enables a three-outcome decision strategy, allowing the system to issue alarms, defer uncertain cases, or identify normal operation. Experiments on a real-world power line dataset show that the proposed approach maintains stable detection performance and well-calibrated confidence under distribution shift. The results demonstrate that incorporating uncertainty-aware inference and risk-adaptive decision logic improves the reliability of AI-enabled monitoring systems, making the framework suitable for IoT-driven consumer energy applications.
- 2 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Consumer Electronics
- Vol. 72 (2) , 4018-4028
Risk-Aware AIoT-Based Fault Detection for Power Line Monitoring in Consumer Energy Systems
Reliable power line monitoring is critical for consumer energy systems that increasingly depend on distributed sensors, smart terminals, and IoT-enabled edge devices. In practical deployments, fault detection performance is often affected by changing operating conditions, noisy measurements, and unreliable prediction confidence. This paper proposes a risk-aware AIoT-based fault detection framework that integrates multi-domain signal representation, uncertainty-aware inference, and confidence-adaptive decision making. High-frequency waveform signals are analyzed across time, frequency, and wavelet domains to capture complementary fault characteristics, and are adaptively fused to preserve localized and nonstationary patterns. Instead of producing deterministic outputs, a Dirichlet-based Prior Network is employed to jointly estimate fault probability and predictive uncertainty. These quantities are combined into a scalar risk score that enables a three-outcome decision strategy, allowing the system to issue alarms, defer uncertain cases, or identify normal operation. Experiments on a real-world power line dataset show that the proposed approach maintains stable detection performance and well-calibrated confidence under distribution shift. The results demonstrate that incorporating uncertainty-aware inference and risk-adaptive decision logic improves the reliability of AI-enabled monitoring systems, making the framework suitable for IoT-driven consumer energy applications.
- 1 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1-12
Robust Energy Management and Workload Allocation in Islanded Data Center Microgrids with Data-Driven Risk-Tunable Approach
The rapid development of cloud computing, Big Data, and artificial intelligence has driven a surge in data center energy demand, while traditional power grids struggle to meet their high reliability and low-carbon requirements. To address this challenge, this paper proposes a co-optimization framework for islanded data center microgrids and develops a two-stage robust optimization model. The model leverages a coordinated control layer to centralize decision-making for the energy supply and computing resource layers, enabling joint optimization of energy management and workload allocation while minimizing total costs. For computing resources optimization, a cross-regional communication network is established to facilitate coordinated workload spatial allocation among geographically distributed data centers, enhancing server resource utilization and optimizing energy consumption. A quality of service constraint mechanism using dynamic voltage and frequency scaling technology is developed, alongside an average response time analysis based on queuing theory. To address uncertainties in wind power generation, load demand, and outdoor temperature, a data-driven risk-tunable modeling approach is proposed. The method constructs distributionally robust chance-constrained programming using Wasserstein distance, transforms it into a risk-bound optimization problem, and designs a polyhedral uncertainty set that adaptively adjusts to risk levels and sample sizes. Finally, case studies demonstrate the effectiveness of the proposed model in improving data center resource utilization, reducing energy consumption, and optimizing robustness adjustment capabilities.
- 1 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1-12
Robust Energy Management and Workload Allocation in Islanded Data Center Microgrids with Data-Driven Risk-Tunable Approach
The rapid development of cloud computing, Big Data, and artificial intelligence has driven a surge in data center energy demand, while traditional power grids struggle to meet their high reliability and low-carbon requirements. To address this challenge, this paper proposes a co-optimization framework for islanded data center microgrids and develops a two-stage robust optimization model. The model leverages a coordinated control layer to centralize decision-making for the energy supply and computing resource layers, enabling joint optimization of energy management and workload allocation while minimizing total costs. For computing resources optimization, a cross-regional communication network is established to facilitate coordinated workload spatial allocation among geographically distributed data centers, enhancing server resource utilization and optimizing energy consumption. A quality of service constraint mechanism using dynamic voltage and frequency scaling technology is developed, alongside an average response time analysis based on queuing theory. To address uncertainties in wind power generation, load demand, and outdoor temperature, a data-driven risk-tunable modeling approach is proposed. The method constructs distributionally robust chance-constrained programming using Wasserstein distance, transforms it into a risk-bound optimization problem, and designs a polyhedral uncertainty set that adaptively adjusts to risk levels and sample sizes. Finally, case studies demonstrate the effectiveness of the proposed model in improving data center resource utilization, reducing energy consumption, and optimizing robustness adjustment capabilities.
- 3 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 15 (2) , 1167-1179
Distributed Secondary Control With an Event-Triggered Consensus-Based Observer for Energy Storage Systems in Islanded DC Microgrids
This paper proposes a distributed secondary control strategy with an event-triggered consensus-based observer. Firstly, a voltage-shifting term is introduced in the proposed control strategy to ensure accurate current sharing, faster state-of-charge (SOC) balancing and bus voltage restoration. Since the SOC balancing speed becomes very slow when the difference in SOC between battery energy units (BEUs) is small, and SOC balancing of BEUs with low power is difficult. Therefore, an adaptive SOC balancing factor to improve the balancing speed is proposed in this control strategy. In addition, communication delay can lead to large errors in traditional consensus-based observers, and continuous communication can bring a significant burden. Considering these issues, the event-triggered consensus-based observer is proposed. This observer can achieve accurate average consensus under communication delay and greatly reduce communication burden. The convergence of the proposed observer under communication delay is theoretically proven, and the Zeno behavior is excluded. At last, the effectiveness of the proposed control strategy has been verified in MATLAB/Simulink and RT-LAB experiments.
- 3 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 15 (2) , 1167-1179
Distributed Secondary Control With an Event-Triggered Consensus-Based Observer for Energy Storage Systems in Islanded DC Microgrids
This paper proposes a distributed secondary control strategy with an event-triggered consensus-based observer. Firstly, a voltage-shifting term is introduced in the proposed control strategy to ensure accurate current sharing, faster state-of-charge (SOC) balancing and bus voltage restoration. Since the SOC balancing speed becomes very slow when the difference in SOC between battery energy units (BEUs) is small, and SOC balancing of BEUs with low power is difficult. Therefore, an adaptive SOC balancing factor to improve the balancing speed is proposed in this control strategy. In addition, communication delay can lead to large errors in traditional consensus-based observers, and continuous communication can bring a significant burden. Considering these issues, the event-triggered consensus-based observer is proposed. This observer can achieve accurate average consensus under communication delay and greatly reduce communication burden. The convergence of the proposed observer under communication delay is theoretically proven, and the Zeno behavior is excluded. At last, the effectiveness of the proposed control strategy has been verified in MATLAB/Simulink and RT-LAB experiments.
- Open Access
- 15 June 2022
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 19 (1)
Hybrid voltage and current control strategy for virtual synchronous generator under unbalanced voltage conditions
The traditional VSG strategy does not consider the negative sequence component, which will lead to current imbalance and power oscillation under unbalanced voltage. Several improved control strategies of VSG are usable for operating under unbalanced voltage nowadays. These control strategies usually require a complex PLL (phase‐locked loop) to detect sequence components, and a current reference generator to convert voltage references to current references. This paper proposes an improved control strategy for VSG. The main contributions are in threefold: (1) A hybrid voltage and current control strategy by simultaneously controlling the positive sequence output voltage and negative sequence output current is proposed, which can achieve different operation demands under unbalanced voltage conditions without changing the original characteristics of VSG. (2) A positive and negative sequence decoupling method is designed to acquire the synchronization phase information directly from the positive sequence voltage control branch, thereby avoiding the use of complex PLL (phase locked loop). (3) A general formulation for the negative sequence current references is presented to control the power oscillations or the current balance flexibly. The correctness and effectiveness of the control strategy are verified by simulation and experimental results.
- 15 June 2022
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 19 (1)
Open AccessHybrid voltage and current control strategy for virtual synchronous generator under unbalanced voltage conditions
The traditional VSG strategy does not consider the negative sequence component, which will lead to current imbalance and power oscillation under unbalanced voltage. Several improved control strategies of VSG are usable for operating under unbalanced voltage nowadays. These control strategies usually require a complex PLL (phase‐locked loop) to detect sequence components, and a current reference generator to convert voltage references to current references. This paper proposes an improved control strategy for VSG. The main contributions are in threefold: (1) A hybrid voltage and current control strategy by simultaneously controlling the positive sequence output voltage and negative sequence output current is proposed, which can achieve different operation demands under unbalanced voltage conditions without changing the original characteristics of VSG. (2) A positive and negative sequence decoupling method is designed to acquire the synchronization phase information directly from the positive sequence voltage control branch, thereby avoiding the use of complex PLL (phase locked loop). (3) A general formulation for the negative sequence current references is presented to control the power oscillations or the current balance flexibly. The correctness and effectiveness of the control strategy are verified by simulation and experimental results.