Mervi Somervuori
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mervi Somervuori has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Elisa Isotahdon
Materials in Extreme Environments, VTT Technical Research Centre of Finland Ltd., 02150 Espoo, Finland
2 shared publications - Leena Carpén
Materials in Extreme Environments, VTT Technical Research Centre of Finland Ltd., 02150 Espoo, Finland
2 shared publications - Maija Nuppunen-Puputti
VTT Technical Research Centre of Finland Ltd., Espoo, Finland
2 shared publications - Malin Bomberg
VTT Technical Research Centre of Finland Ltd., Espoo, Finland
2 shared publications - Pauliina Rajala
Materials Performance, VTT Technical Research Centre of Finland Espoo, Finland
2 shared publications Maria Oksa
Carbon neutral solutions, VTT Technical Research Centre of Finland, Espoo, Finland
1 shared publication
Latest Publications
- Open Access
- 14 April 2022
- Published by Springer Nature in Journal of Thermal Spray Technology
- Vol. 31 (5) , 1581-1597
Comparative Study on the Corrosion Performance of APS-, HVOF-, and HVAF-Sprayed NiCr and NiCrBSi Coatings in NaCl Solutions
Corrosion performance of NiCr and NiCrBSi coatings produced by APS, HVOF, and HVAF was studied by electrochemical measurements and immersion tests in 0.5 and 3.5 wt.% NaCl solutions. In the electrochemical measurements, the NiCr coatings performed better than the NiCrBSi coatings. The effect of the coating process on the corrosion resistance of the material was significantly lower than that of the selected materials, NiCr or NiCrBSi. All the coatings showed a tendency to passivate but suffered from localized corrosion. During immersion exposure for ten weeks, localized corrosion appeared at heterogeneous areas of the coatings, including voids, defects, or powder particles that had not melted during the spraying process.
- 14 April 2022
- Published by Springer Nature in Journal of Thermal Spray Technology
- Vol. 31 (5) , 1581-1597
Open AccessComparative Study on the Corrosion Performance of APS-, HVOF-, and HVAF-Sprayed NiCr and NiCrBSi Coatings in NaCl Solutions
Corrosion performance of NiCr and NiCrBSi coatings produced by APS, HVOF, and HVAF was studied by electrochemical measurements and immersion tests in 0.5 and 3.5 wt.% NaCl solutions. In the electrochemical measurements, the NiCr coatings performed better than the NiCrBSi coatings. The effect of the coating process on the corrosion resistance of the material was significantly lower than that of the selected materials, NiCr or NiCrBSi. All the coatings showed a tendency to passivate but suffered from localized corrosion. During immersion exposure for ten weeks, localized corrosion appeared at heterogeneous areas of the coatings, including voids, defects, or powder particles that had not melted during the spraying process.
- Open Access
- 21 October 2021
- Published by MDPI AG in Corrosion and Materials Degradation
- Vol. 2 (4) , 603-624
A Comparison of Different Natural Groundwaters from Repository Sites—Corrosivity, Chemistry and Microbial Community
In Finland, the repositories for low and intermediate-level radioactive waste (LLW and ILW) will be situated at three different geographical locations in about 60 to 100 m deep granite bedrock where the waste and waste containers can be subjected to anoxic groundwater containing microbes. The composition of groundwater varies in terms of chemistry and microbial activity in different locations. In this study, groundwater from the three repository areas was analyzed in respect to chemistry and microbial community. Corrosion tendency of three steel grades, carbon steel AISI/SAE 1005 and stainless steels AISI 304 and 316L, was studied in these groundwater environments using electrochemical methods. As a reference, measurements were also performed in simulated groundwater without microbes. The measurements show that corrosivity of the water and thus the steels’ performance differs depending on water origin. In addition, the groundwater differed remarkably in their chemical composition as well as abundance and diversity of microbial community between the sites. Consequently, the local environment has to be considered when evaluating the long-term evolution of disposal concepts.
- 21 October 2021
- Published by MDPI AG in Corrosion and Materials Degradation
- Vol. 2 (4) , 603-624
Open AccessA Comparison of Different Natural Groundwaters from Repository Sites—Corrosivity, Chemistry and Microbial Community
In Finland, the repositories for low and intermediate-level radioactive waste (LLW and ILW) will be situated at three different geographical locations in about 60 to 100 m deep granite bedrock where the waste and waste containers can be subjected to anoxic groundwater containing microbes. The composition of groundwater varies in terms of chemistry and microbial activity in different locations. In this study, groundwater from the three repository areas was analyzed in respect to chemistry and microbial community. Corrosion tendency of three steel grades, carbon steel AISI/SAE 1005 and stainless steels AISI 304 and 316L, was studied in these groundwater environments using electrochemical methods. As a reference, measurements were also performed in simulated groundwater without microbes. The measurements show that corrosivity of the water and thus the steels’ performance differs depending on water origin. In addition, the groundwater differed remarkably in their chemical composition as well as abundance and diversity of microbial community between the sites. Consequently, the local environment has to be considered when evaluating the long-term evolution of disposal concepts.
- Open Access
- 17 May 2021
- Published by MDPI AG in Materials Proceedings
- Vol. 6 (1) , 33
Corrosivity of Different Natural Groundwaters from Repository Sites
In Finland, the repositories for low- and intermediate-level waste (LLW and ILW) are situated in three different geographical locations in deep granite bedrock, where waste containers can be subjected to anoxic groundwater containing microbes. The composition of groundwater varies in terms of chemistry and microbial activity in different locations. In this study, groundwater from three repository areas was analyzed with regard to chemistry and microbial community. The corrosion tendency of three steel grades, carbon steel AISI/SAE 1005 and stainless steels AISI 304 and 316L, was studied in these groundwater environments using electrochemical methods. As a reference, measurements were also performed in simulated groundwater that did not contain microbes. The measurements show that the corrosivity of the water, and thus, the steels’ performance, differed depending on its location of origin. Additionally, the groundwater differed remarkably in their chemical composition as well as the abundance and diversity of the microbial community within them. Consequently, the local environment has to be considered when evaluating the long-term safety of the disposal of nuclear waste.
- 17 May 2021
- Published by MDPI AG in Materials Proceedings
- Vol. 6 (1) , 33
Open AccessCorrosivity of Different Natural Groundwaters from Repository Sites
In Finland, the repositories for low- and intermediate-level waste (LLW and ILW) are situated in three different geographical locations in deep granite bedrock, where waste containers can be subjected to anoxic groundwater containing microbes. The composition of groundwater varies in terms of chemistry and microbial activity in different locations. In this study, groundwater from three repository areas was analyzed with regard to chemistry and microbial community. The corrosion tendency of three steel grades, carbon steel AISI/SAE 1005 and stainless steels AISI 304 and 316L, was studied in these groundwater environments using electrochemical methods. As a reference, measurements were also performed in simulated groundwater that did not contain microbes. The measurements show that the corrosivity of the water, and thus, the steels’ performance, differed depending on its location of origin. Additionally, the groundwater differed remarkably in their chemical composition as well as the abundance and diversity of the microbial community within them. Consequently, the local environment has to be considered when evaluating the long-term safety of the disposal of nuclear waste.